At least 937 records · Page 52

Signal-Conditioning Amplifier Recorders

Signal-conditioning amplifier recorders (SCAmpRs) have been proposed as a means of simplifying and upgrading the Kennedy Space Center (KSC) Ground Measurement System (GMS), which is a versatile data-acquisition system that gathers and records a variety of measurement data before and during the launch of a space shuttle. In the present version of the GMS system, signal conditioning amplifiers digitize and transmit data to a VME chassis that multiplexes up to 416 channels. The data is transmitted via a high-speed data bus to a second VME chassis where it is available for snapshots. The data is passed from the second VME chassis to a high-speed data recorder. This process is duplicated for installations at two launch pads and the Vehicle Assembly Building (VAB). Since any failure of equipment in the data path results in loss of data, much of the system is redundant. The architecture of the existing GMS limits expansion or any modification to the system to meet changing requirements because of the cost and time required. A SCAmpR-based system is much more flexible. The basis of the simplification, flexibility, and reliability is the shifting of the recording function to the individual amplifier channels. Each SCAmpR is a self-contained single channel data acquisition system, which in its current implementation, has a data storage capacity of up to 30 minutes when operating at the fastest data sampling rates. The SCAmpR channels are self-configuring and self-calibrating. Multiple SCAmpR channels are ganged on printed circuit boards and mounted in a chassis that provides power, a network hub, and Inter-Range Instrument Group (IRIG) time signals. The SCAmpR channels share nothing except physical mounting on a circuit board. All circuitry is electrically separate for each channel. All that is necessary to complete the data acquisition system is a single master computer tied to the SCAmpR channels by standard network equipment. The size of the data acquisition system dictates the requirements for the specific network equipment.

Medelius, Pedro J.↗

Catalysts for use in electrochemical applications and electrodes and devices using same

An electrode for reduction of an oxidant including a phosphorus-doped carbon-containing catalyst represented by the chemical formula CN.sub.xP.sub.y, where x is from 0 to about 10 wt. % and y is from about 1 ppm to about 10 wt. %. A device for producing electricity by facilitating an electrochemical reaction between a fuel and an oxidant. The device including a first electrode for oxidizing the fuel to produce protons and electrons. The device further includes a second electrode in electrical communication with the first electrode when electrically connected to the external circuit. The second electrode includes a phosphorus-doped carbon-containing catalyst for reducing the oxidant and is represented by the chemical formula CN.sub.xP.sub.y, where x is from 0 to about 10 wt. % and y is from about 1 ppm to about 10 wt. %. The device further includes an electrolyte, such as, a membrane, separating the first electrode from the second electrode.

30 DIRECT ENERGY CONVERSION↗

Self-healing liquid/solid state battery

A battery system that exchanges energy with an external device is provided. The battery system includes a positive electrode having a first metal or alloy, a negative electrode having a second metal or alloy, and an electrolyte including a salt of the second metal or alloy. The positive electrode, the negative electrode, and the electrolyte are in a liquid phase at an operating temperature during at least one portion of operation. The positive electrode is entirely in a liquid phase in one charged state and includes a solid phase in another charged state. The solid phase of the positive electrode includes a solid intermetallic formed by the first and the second metals or alloys. Methods of storing electrical energy from an external circuit using such a battery system are also provided.

25 ENERGY STORAGE↗

Ga2O3 Packaging and Thermal Management Challenges and Opportunities

This project addresses the early-stage research and development to design and build packages that enable practical utilization of Ga2O3 semiconductor devices in power electronic circuits. The project will encompass electrical, thermal, thermomechanical and reliability aspects in the package design. As compared to silicon (Si), SiC or GaN-based packaging, using a Ga2O3 device will require significant research and innovations in the attachment of the oxide device to substrates, attachment of the substrate to the baseplate/heat exchanger, appropriate electrical interconnections, as well as the type and location of the thermal management solutions. A thorough understanding and characterization of the thermal transport properties of the Ga2O3 device layer is also essential to understand and quantify the package performance. Addressing all these aspects will result in a high-performance, low-cost and reliable package.

30 DIRECT ENERGY CONVERSION↗

Method and system for arbitrary optical pulse generation

A system, method, and apparatus for continuous seed laser pulses supplied to a CW pumped pre-amplifier and/or power-amplifier chain comprises an optical modulator configured to impress pulse signals on an optical signal, a waveform generator configured to establish a structure of the optical signal, and a keep-alive circuit that generates a continuous electrical pulse pattern provided to the optical modulator, wherein the system provides a continuous seed laser pulse structure.

Johnson, David↗

Thermoelectric coatings for waste heat recovery and photo-thermal power

An energy harvesting system for collecting energy from sources of thermal energy that exist in the environment and convert the energy to electricity. The system has N-P junctions mounted on the outer surface of a conduit, pipe or flue. A hot medium flows through the conduit, pipe or flue. The p-n junctions operate as thermoelectric power generators. Heat absorbed at the p-n junctions increases the kinetic energy of charge carriers causing migration of the charge carriers. This thermally-driven migration of charge carriers is used to drive an electrical current in an external circuit.

Farmer, Joseph C.↗

Additively manufactured tamper evident container

A tamper evident container includes a container body having walls surrounding a cavity. The walls are composed of a non-electrically conductive material and at least one integrity sensor that is embedded in the non-electrically conductive material. A monitoring circuit is configured to monitor the tamper evident container using the at least one integrity sensor and determine a state-of-health of the tamper evident container.

Bernardin, John D.↗

An Analytic Model Of Thermal Drift In Piezoresistive Microcantilever Sensors

A closed form semi-empirical model has been developed to understand the physical origins of thermal drift in piezoresistive microcantilever sensors. The two-component model describes both the effects of temperature-related bending and heat dissipation on the piezoresistance. The temperature-related bending component is based on the Euler-Bernoulli theory of elastic deformation applied to a multilayer cantilever. The heat dissipation component is based on energy conservation per unit time for a piezoresistive cantilever in a Wheatstone bridge circuit, representing a balance between electrical power input and heat dissipation into the environment. Conduction and convection are found to be the primary mechanisms of heat transfer, and the dependence of these effects on the thermal conductivity, temperature, and flow rate of the gaseous environment is described. The thermal boundary layer value which defines the length scale of the heat dissipation phenomenon is treated as an empirical fitting parameter. Using the model, it is found that the cantilever heat dissipation is unaffected by the presence of a thin polymer coating, therefore the residual thermal drift in the differential response of a coated and uncoated cantilever is the result of non-identical temperature-related bending. Differential response data shows that residual drift is eliminated under isothermal laboratory conditions but not the unregulated and variable conditions that exist in the outdoor environment (i.e., the field). The two-component model is then validated by simulating the thermal drifts of an uncoated and a coated piezoresistive cantilever under field conditions over a 24 hour period using only meteorological data as input.

47 OTHER INSTRUMENTATION↗

Substation-Level Grid Topology Optimization Using Bus Splitting

Operations of substation circuit breakers are important for maintenance needs and topology reconfiguration in power systems. Bus splitting is one type of topology change where the two bus bars at a substation can become electrically disconnected under certain actions of circuit breakers. Because these events involve detailed substation modeling, they are typically not considered in routine power system operation and control. In this paper, an improved substation-level topology optimization framework is developed by expanding traditional line switching decisions by breaker-level bus splitting, which can further reduce grid congestion and generation costs. A tight McCormick relaxation is proposed to reformulate the bilinear terms in the resultant optimization problem to linear inequality constraints. Thus, a tractable mixed-integer linear program reformulation is attained that allows for efficient solutions in real-time operations. Numerical studies on the IEEE 14-bus and 118-bus systems demonstrate the computational performance and economic benefits of the proposed topology optimization approach.

bus split↗

Substation-Level Grid Topology Optimization Using Bus Splitting: Preprint

Operations of substation circuit breakers are of high significance for performing system maintenance and topology optimization. Bus splitting is one type of topology changes where the two bus-bars at a substation become electrically disconnected after certain actions of circuit breakers. As these events involve detailed substation modeling, they are not typically considered in power system routine operation and control. In this paper, an improved substation-level topology optimization is developed by expanding traditional line switching with breaker-level bus splitting, which can further reduce grid congestion and generation costs. A tight McCormick relaxation is proposed to reformulate the bi-linear terms in the resultant topology optimization model. Thus, a tractable mixed-integer linear program formulation is presented which can be efficiently solved for real-time control. Numerical studies on the IEEE 14-bus and 118-bus systems demonstrate the performance and economic benefits of the proposed topology optimization approach.

bus split↗

Reference module selection criteria for accurate testing of photovoltaic (PV) panels

It is shown that for accurate testing of PV panels the correct selection of reference modules is important. A detailed description of the test methodology is given. Three different types of reference modules, having different I{sub SC} (short circuit current) and power (in Wp) have been used for this study. These reference modules have been calibrated from NREL. It has been found that for accurate testing, both I{sub SC} and power of the reference module must be either similar or exceed to that of modules under test. In case corresponding values of the test modules are less than a particular limit, the measurements may not be accurate. The experimental results obtained have been modeled by using simple equivalent circuit model and associated I-V equations. (author)

14 SOLAR ENERGY↗

Electro-optical Probing Of Terahertz Integrated Circuits

Electro-optical probe developed to perform noncontact, nondestructive, and relatively noninvasive measurements of electric fields over broad spectrum at millimeter and shorter wavelengths in integrated circuits. Manipulated with conventional intregrated-circuit-wafer-probing equipment and operated without any special preparation of integrated circuits. Tip of probe small electro-optical crystal serving as proximity electric-field sensor.

Bhasin, K. B.↗

Self-pulsing of hollow cathode discharge in various gases

In this paper, we investigate the self-pulsing phenomenon of cavity discharge in a cylindrical hollow cathode in various gases including argon, helium, nitrogen, oxygen, and air. The current-voltage characteristics of the cavity discharge, the waveforms of the self-pulsing current and voltage as well as the repetition frequency were measured. The results show that the pulsing frequency ranges from a few to tens kilohertz and depends on the averaged current and the pressure in all gases. The pulsing frequency will increase with the averaged current and decrease with the pressure. The rising time of the current pulse is nearly constant in a given gas or mixture. The self-pulsing does not depend on the external ballast but is affected significantly by the external capacitor in parallel with the discharge cell. The low-current self-pulsing in hollow cathode discharge is the mode transition between Townsend and glow discharges. It can be described by the charging-discharging process of an equivalent circuit consisting of capacitors and resistors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precise time and time interval applications to electric power systems

There are many applications of precise time and time interval (frequency) in operating modern electric power systems. Many generators and customer loads are operated in parallel. The reliable transfer of electrical power to the consumer partly depends on measuring power system frequency consistently in many locations. The internal oscillators in the widely dispersed frequency measuring units must be syntonized. Elaborate protection and control systems guard the high voltage equipment from short and open circuits. For the highest reliability of electric service, engineers need to study all control system operations. Precise timekeeping networks aid in the analysis of power system operations by synchronizing the clocks on recording instruments. Utility engineers want to reproduce events that caused loss of service to customers. Precise timekeeping networks can synchronize protective relay test-sets. For dependable electrical service, all generators and large motors must remain close to speed synchronism. The stable response of a power system to perturbations is critical to continuity of electrical service. Research shows that measurement of the power system state vector can aid in the monitoring and control of system stability. If power system operators know that a lightning storm is approaching a critical transmission line or transformer, they can modify operating strategies. Knowledge of the location of a short circuit fault can speed the re-energizing of a transmission line. One fault location technique requires clocks synchronized to one microsecond. Current research seeks to find out if one microsecond timekeeping can aid and improve power system control and operation.

Robert E. Wilson↗

Rotary Power Transformer and Inverter Circuit

Noise lower than with sliprings. Rotary transformer transfers electric power across rotary joint. No wearing contacts, no contact noise, and no contamination from lubricants or wear debris. Because additional inductor not required, size and complexity of circuit reduced considerably.

Mclyman, C. W. T.↗

Fast-responding short circuit protection system with self-reset for use in circuit supplied by DC power

A short circuit protection system includes an inductor, a switch, a voltage sensing circuit, and a controller. The switch and inductor are electrically coupled to be in series with one another. A voltage sensing circuit is coupled across the switch and the inductor. A controller, coupled to the voltage sensing circuit and the switch, opens the switch when a voltage at the output terminal of the inductor transitions from above a threshold voltage to below the threshold voltage. The controller closes the switch when the voltage at the output terminal of the inductor transitions from below the threshold voltage to above the threshold voltage.

Burns, Bradley M.↗

Influences of impedance matching network on pulse-modulated radio frequency atmospheric pressure glow discharges

Pulse-modulated RF atmospheric pressure glow discharges (APDGs) were investigated in recent years to reduce the thermal accumulation and extend the operation region of the stable alpha glow mode. Different pulse-modulated voltage and current waveforms were acquired in previous experiments, but no attention was paid to the interpretation. We investigated this issue and associated phenomenon via positive and negative feedback effects derived from varying the series capacitor in the inversely L-shaped matching network used in our pulse-modulated RF APGD source. The evolutions of pulse-modulated RF waveforms were found to be associated with the feedback region and the pulsed plasma absorbed RF power. In the positive feedback region, pulse-modulated RF APGDs are relatively stable. In the negative feedback region, wide spikes as well as undershoots occur in RF voltage and current waveforms and the plasma absorbed RF power. In case of a high RF power discharge with a low modulation frequency, the pulse-modulated RF APGD is extinguished and re-ignited due to the enhanced undershoot during the initial pulse phase. The pulse-modulated RF APGD can transit from positive to negative feedback region in a range of series capacitance. Experimental results are discussed by the aid of equivalent circuit, negative and positive feedback effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methods of Using a Magnetic Field Response Sensor Within Closed, Electrically Conductive Containers

Magnetic field response sensors are a class of sensors that are powered via oscillating magnetic fields, and when electrically active, respond with their own magnetic fields with attributes dependent upon the magnitude of the physical quantity being measured. A magnetic field response recorder powers and interrogates the magnetic sensors [see Magnetic-Field-Response Measurement- Acquisition System, NASA Tech Briefs Vol. 30, No, 6 (June 2006, page 28)]. Electrically conductive containers have low transmissivity for radio frequency (RF) energy and thus present problems for magnetic field response sensors. It is necessary in some applications to have a magnetic field response sensor s capacitor placed in these containers. Proximity to conductive surfaces alters the inductance and capacitance of the sensors. As the sensor gets closer to a conductive surface, the electric field and magnetic field energy of the sensor is reduced due to eddy currents being induced in the conductive surface. Therefore, the capacitors and inductors cannot be affixed to a conductive surface or embedded in a conductive material. It is necessary to have a fixed separation away from the conductive material. The minimum distance for separation is determined by the desired sensor response signal to noise ratio. Although the inductance is less than what it would be if it were not in proximity to the conductive surface, the inductance is fixed. As long as the inductance is fixed, all variations of the magnetic field response are due to capacitance changes. Numerous variations of inductor mounting can be utilized, such as providing a housing that provides separation from the conductive material as well as protection from impact damage. The sensor can be on the same flexible substrate with a narrow throat portion of the sensor between the inductor and the capacitor, Figure 1. The throat is of sufficient length to allow the capacitor to be appropriately placed within the container and the inductor placed outside the container. The throat is fed through the orifice in the container wall (e.g., fuel tank opening) and connects to the inductor and capacitor via electrical leads to form a closed circuit, Figure 2. Another embodiment is to have the inductor and capacitor fabricated as separate units. In this embodiment, the inductor is mounted external to the container, and the capacitor is mounted internal to the container, Figure 1. Electrical leads are fed through the orifice to connect the inductor and capacitor, Figure 2. When a container holding multiple sensors is made of a conductive material, an antenna can be placed internal to the container. An internal antenna allows all components of the sensors to reside inside the container. The antenna must be separated from the container wall s conductive surface. Additionally, the inductors must be maintained in a fixed position relative to and separated from the container

Woodward, Stanley E.↗