Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

An FPGA-Based Test-Bed for Reliability and Endurance Characterization of Non-Volatile Memory

Memory technologies are divided into two categories. The first category, nonvolatile memories, are traditionally used in read-only or read-mostly applications because of limited write endurance and slow write speed. These memories are derivatives of read only memory (ROM) technology, which includes erasable programmable ROM (EPROM), electrically-erasable programmable ROM (EEPROM), Flash, and more recent ferroelectric non-volatile memory technology. Nonvolatile memories are able to retain data in the absence of power. The second category, volatile memories, are random access memory (RAM) devices including SRAM and DRAM. Writing to these memories is fast and write endurance is unlimited, so they are most often used to store data that change frequently, but they cannot store data in the absence of power. Nonvolatile memory technologies with better future potential are FRAM, Chalcogenide, GMRAM, Tunneling MRAM, and Silicon-Oxide-Nitride-Oxide-Silicon (SONOS) EEPROM.

Rao, Vikram↗

High Voltage TAL Erosion Characterization

Extended operation of a D-80 anode layer thruster at high voltage was investigated. The thruster was operated for 1200 hours at 700 Volts and 4 Amperes. Laser profilometry was employed to quantify the erosion of the thruster's graphite guard rings and electrodes at 0, 300, 600, 900, and 1200 hours. Thruster performance and electrical characteristics were monitored over the duration of the investigation. The guard rings exhibited asymmetric erosion that was greatest in the region of the cathode. Erosion of the guard rings exposed the magnet poles between 600 to 900 hours of operation.

Jacobson, David T.↗

Characterization of HEM silicon for solar cells

The Heat Exchanger Method (HEM) is a promising low-cost ingot casting process for material used for solar cells. This is the only method that is capable of casting single crystal ingots with a square cross section using a directional solidification technique. This paper describes the chemical, mechanical and electrical properties of the HEM silicon material as a function of position within the ingot.

Dumas, K. A.↗

Evaluation program for secondary spacecraft cells. Initial evaluation tests of General Electric Company 4.0 ampere-hour nickel-cadmium spacecraft cells for the AMPTE satellite program

Cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test are addressed. The Active Magnetic Particle Tracer Explorer (AMPTE) cell design was characterized and the effects of specific mission parameters on cell life were demonstrated.

Harkness, J. D.↗

Development of a process for high capacity arc heater production of silicon for solar arrays

A high temperature silicon production process using existing electric arc heater technology is discussed. Silicon tetrachloride and a reductant, liquid sodium, were injected into an arc heated mixture of hydrogen and argon. Under these high temperature conditions, a very rapid reaction occurred, yielding silicon and gaseous sodium chloride. Techniques for high temperature separation and collection of the molten silicon were developed. The desired degree of separation was not achieved. The electrical, control and instrumentation, cooling water, gas, SiCl4, and sodium systems are discussed. The plasma reactor, silicon collection, effluent disposal, the gas burnoff stack, and decontamination and safety are also discussed. Procedure manuals, shakedown testing, data acquisition and analysis, product characterization, disassembly and decontamination, and component evaluation are reviewed.

Meyer, T. N.↗

Analysis of altimeter data jointly with seafloor electric data (vertically integrated velocity) and VCTD-yoyo data (detailed profiles of VCTD)

We propose simultaneous analyses of the TOPEX/POSEIDON altimetry data, in situ data--mainly permanent seafloor electric recordings--and velocity, conductivity, temperature, density (VCTD)-yoyo data at several stations in areas of scientific interest. We are planning experiments in various areas of low and high energy levels. Several complementary and redundant methods will be used to characterize the ocean circulation and its short- and long-term variability. We shall emphasize long-term measurement using permanent stations. Our major initial objectives with the TOPEX/POSEIDON mission are the Confluence area in the Argentine Basin and the Circumpolar Antarctic Current. An early experiment was carried out in the Confluence zone in 1988 and 1990 (Confluence Principal Investigators, 1990) to prepare for an intensive phase later one. This intensive phase will include new types of instrumentation. Preliminary experiments will be carried out in the Mediterranean Sea (in 1991) and in the North Atlantic Ocean (in 1992, north of the Canary Islands) to test the new instrumentation.

Tarits, Pascal D.↗

Component Reliability Testing of Long-Life Sorption Cryocoolers

This paper summarizes ongoing experiments characterizing the ability of critical sorption cryocooler components to achieve highly reliable operation for long-life space missions. Test data obtained over the past several years at JPL are entirely consistent with achieving ten year life for sorption compressors, electrical heaters, container materials, valves, and various sorbent materials suitable for driving 8 to 180 K refrigeration stages. Test results for various compressor systems are reported. Planned future tests necessary to gain a detailed understanding of the sensitivity of cooler performance and component life to operating constraints, design configurations, and fabrication, assembly and handling techniques, are also discussed.

operating constraints fabrication design testing↗

Eroding Potentiometers

Eroding potentiometers have been devised for measuring the time-dependent positions of char fronts advancing through layers of insulating material subject to intense heating from one side. In the original application, the material layers of interest are thermal insulators in rocket motors and the heat comes from firing of the motors, but the principle of operation is equally applicable to other insulating materials subject to intense heating (e.g., ablative fire-retardant materials). Measuring the thickness decrement of propellant (in hybrid motors in particular) is another possible application of this transducer. Telemetry informs mission control of the propellant left after each burn. An eroding potentiometer could be characterized, more precisely, as an eroding two-wire resistor. It includes a twisted pair of thin, insulated wires oriented along the thickness of, and embedded in, the layer of thermal-insulation material to be tested (see figure). The electrical insulation material on the wires should be one for which the charring temperature is about the same as (or perhaps slightly less than) that of the thermal- insulation material to be tested. In the original rocket-motor application, the wires have a diameter of 0.003 in. (.0.08 mm), are made of manganin, and are coated with polyimide for electrical insulation. Outside the thermal insulation on the cold side, the wire leads are connected to a Wheatstone bridge circuit for measurement of electrical resistance change.

Eggett, Mark↗

Current Density Measurements of an Annular-Geometry Ion Engine

The concept of the annular-geometry ion engine, or AGI-Engine, has been shown to have many potential benefits when scaling electric propulsion technologies to higher power. However, the necessary asymmetric location of the discharge cathode away from thruster centerline could potentially lead to non-uniformities in the discharge not present in conventional geometry ion thrusters. In an effort to characterize the degree of this potential non-uniformity, a number of current density measurements were taken on a breadboard AGI-Engine. Fourteen button probes were used to measure the ion current density of the discharge along a perforated electrode that replaced the ion optics during conditions of simulated beam extraction. Three Faraday probes spaced apart in the vertical direction were also used in a separate test to interrogate the plume of the AGI-Engine during true beam extraction. It was determined that both the discharge and the plume of the AGI-Engine are highly uniform, with variations under most conditions limited to +/-10% of the average current density in the discharge and +/-5% of the average current density in the plume. Beam flatness parameter measured 30 mm from the ion optics ranged from 0.85 - 0.95, and overall uniformity was shown to generally increase with increasing discharge and beam currents. These measurements indicate that the plasma is highly uniform despite the asymmetric location of the discharge cathode.

Shastry, Rohit↗

Current Density Measurements of an Annular-Geometry Ion Engine

The concept of the annular-geometry ion engine, or AGI-Engine, has been shown to have many potential benefits when scaling electric propulsion technologies to higher power. However, the necessary asymmetric location of the discharge cathode away from thruster centerline could potentially lead to non-uniformities in the discharge not present in conventional geometry ion thrusters. In an effort to characterize the degree of this potential nonuniformity, a number of current density measurements were taken on a breadboard AGI-Engine. Fourteen button probes were used to measure the ion current density of the discharge along a perforated electrode that replaced the ion optics during conditions of simulated beam extraction. Three Faraday probes spaced apart in the vertical direction were also used in a separate test to interrogate the plume of the AGI-Engine during true beam extraction. It was determined that both the discharge and the plume of the AGI-Engine are highly uniform, with variations under most conditions limited to 10% of the average current density in the discharge and 5% of the average current density in the plume. Beam flatness parameter measured 30 mm from the ion optics ranged from 0.85 0.95, and overall uniformity was shown to generally increase with increasing discharge and beam currents. These measurements indicate that the plasma is highly uniform despite the asymmetric location of the discharge cathode.

Shastry, Rohit↗

Study of the use of Metal-Oxide-Silicon (MOS) devices for particulate detection and monitoring in the earth's atmosphere

A metal-oxide-silicon (MOS) capacitor-type particulate sensor was evaluated for use in atmospheric measurements. An accelerator system was designed and tested for the purpose of providing the necessary energy to trigger the MOS-type sensor. The accelerator system and the MOS sensor were characterized as a function of particle size and velocity. Diamond particles were used as particulate sources in laboratory tests. Preliminary tests were performed in which the detector was mounted on an aircraft and flown in the vicinity of coal-fired electric generating plants.

Brooks, A. D.↗

Application of an ultrasonic phase insensitive receiver to material measurements

The theory of a phase insensitive receiver based on acousto-electric effect is presented along with experimental characteristics of a CdS acousto-electric converter (AEC). Since the AEC is nearly phase insensitive, it is ideal for measurements in inhomogeneous materials and/or materials with irregular flatness and parallelism. Through transmission ultrasonic C-scan data of phantom flaws demonstrates a significant improvement in flaw characterization with an AEC over that of a conventional transducer. In addition, measurements with conventional transducers in anisotropically stressed metal samples are shown to lead to grossly inaccurate results due to phase sensitivity. Various other measurements are presented with data contrasting conventional transducers with an AEC in specific NDE applications.

Heyman, J. S.↗

Application of an ultrasonic phase insensitive receiver to material measurements

The theory of a phase insensitive receiver based on acousto-electric effect is presented along with experimental characteristics of a CdS acousto-electric converter (AEC). Since the AEC is nearly phase insensitive, it is ideal for measurements in inhomogeneous materials and/or materials with irregular flatness and parallelism. Through transmission ultrasonic C-scan data of phantom flaws demonstrates a significant improvement in flaw characterization with an AEC over that of a conventional transducer. In addition, measurements with conventional transducers in anisotropically stressed metal samples are shown to lead to grossly inaccurate results due to phase sensitivity. Various other measurements are presented with data contrasting conventional transducers with an AEC in specific NDE applications.

Heyman, J. S.↗

Turbulent magnetic reconnection

The results of two-dimensional spectral-method MHD simulations of the effect of turbulence on magnetic-reconnection processes are presented in extensive graphs and tables and characterized in detail. In a periodic sheet-pinch configuration, early-onset, persistent turbulence is found to occur when a low level of broadband fluctuations is introduced into the initial data. Features observed include small-scale unsteady coherent electric-current and vorticity structures, enhanced viscous and resistive dissipation, unsteady and spatially asymmetric fluid flow, large-scale and small-scale magnetic islands, multiple X points, large-amplitude electric-field fluctuations, and spectral characteristics indicating that the turbulence is broadband in both spatial directions and similar to homogeneous MHD turbulence. The importance of reconnection for studies of solar, magnetospheric, and laboratory plasmas in inhomogeneous magnetic fields is indicated.

Matthaeus, W. H.↗

On-board fault management for autonomous spacecraft

The dynamic nature of the Cargo Transfer Vehicle's (CTV) mission and the high level of autonomy required mandate a complete fault management system capable of operating under uncertain conditions. Such a fault management system must take into account the current mission phase and the environment (including the target vehicle), as well as the CTV's state of health. This level of capability is beyond the scope of current on-board fault management systems. This presentation will discuss work in progress at TRW to apply artificial intelligence to the problem of on-board fault management. The goal of this work is to develop fault management systems. This presentation will discuss work in progress at TRW to apply artificial intelligence to the problem of on-board fault management. The goal of this work is to develop fault management systems that can meet the needs of spacecraft that have long-range autonomy requirements. We have implemented a model-based approach to fault detection and isolation that does not require explicit characterization of failures prior to launch. It is thus able to detect failures that were not considered in the failure and effects analysis. We have applied this technique to several different subsystems and tested our approach against both simulations and an electrical power system hardware testbed. We present findings from simulation and hardware tests which demonstrate the ability of our model-based system to detect and isolate failures, and describe our work in porting the Ada version of this system to a flight-qualified processor. We also discuss current research aimed at expanding our system to monitor the entire spacecraft.

Fesq, Lorraine M.↗

SAFT nickel hydrogen cell cycling status

An overview of the NiH2 cell development is given. The NiH2 SAFT system is an electrochemical (single or dual) stack (IPV). The stack is mounted in an hydroformed Inconel 718 vessel operating at high pressure, equipped with 'rabbit ears' ceramic brazed electrical feedthroughs. The cell design is described: positive electrode, negative electrode, and stack configuration. Overviews of low earth orbit and geostationary earth orbit cyclings are provided. DPA results are also provided. The cycling and DPA results demonstrate that SAFT NiH2 is characterized by high reliability and very stable performances.

Borthomieu, Yannick↗

Nanotechnology: Opportunities and Challenges

Nanotechnology seeks to exploit novel physical, chemical, biological, mechanical, electrical, and other properties, which arise primarily due to the nanoscale nature of certain materials. A key example is carbon nanotubes (CNTs) which exhibit unique electrical and extraordinary mechanical properties and offer remarkable potential for revolutionary applications in electronics devices, computing, and data storage technology, sensors, composites, nanoelectromechanical systems (NEMS), and as tip in scanning probe microscopy (SPM) for imaging and nanolithography. Thus the CNT synthesis, characterization, and applications touch upon all disciplines of science and engineering. This presentation will provide an overview and progress report on this and other major research candidates in Nanotechnology and address opportunities and challenges ahead.

Meyyappan, Meyya↗

Muscle fatigue in frog semitendinosus: role of intracellular pH

The purpose of this study was to utilize glass microelectrodes to characterize the intracellular pH (pHi) before and during recovery from fatigue in the frog semitendinosus (ST) muscle. A second objective was to evaluate the relationship between pHi and contractile function. The frog ST muscle (22 degrees C) was fatigued by direct electrical stimulation with 100-ms 150-Hz trains at 1/s for 5 min. Peak tetanic force (Po) was reduced to 8.5% of initial force and recovered in a biphasic manner, returning to the resting value by 40 min. Resting pHi was 7.00 +/- 0.02 (n = 37) and declined with fatigue to an average value of 6.42 at 3 min of recovery. During recovery pHi significantly increased and by 25 min had returned to the prefatigue value. The pHi recovery was highly correlated to the slow phase of Po recovery (r = 0.98, P less than 0.001). The mean resting membrane potential was -78 +/- 1.0 mV (n = 42) and at 3 min of recovery was depolarized to -67 +/- 4 mV. Both the peak rate of twitch force development (+dP/dt) (r = 0.99, P less than 0.001) and decline (-dP/dt) (r = 0.94, P less than 0.014) were highly correlated to pHi during the slow phase of recovery. Contraction time (CT) and one-half relaxation time (1/2RT) increased significantly and recovered exponentially. The recovery of CT and 1/2RT were both significantly correlated to pHi (r = -0.93, P less than 0.001 and r = -0.86, P less than 0.001 for CT and 1/2RT, respectively).(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Musculoskeletal↗