Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENERGY RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Soft X-ray photoemission with the SSX-100 spectrometer

Photoemission and SEXAFS experiments were conducted using a double crystal monochromator at the Stanford Synchrotron Radiation Laboratory. Photoelectrons were detected using a Surface Science Laboratories SSX-100 electron analyzer, which employs a magnetic/electrostatic lens, hemispherical geometry, and a two-dimensional position-sensitive detector. In the kinetic energy range of interest (1000-2000 eV), a significant improvement in count rate was observed over a single channel cylindrical mirror analyzer system. Ten second scans of the KLL silicon Auger peak manifold were recorded at a large number of photon energies for subsequent determination of SEXAFS spectra.

Hecht, M. H.↗

Direct measurement of the composition and spectra of cosmic rays above 1 TeV/amu from JACEE

Direct measurements on cosmic ray protons through iron above about 1 TeV/amu have been performed in a series of balloon-borne experiments with emulsion chambers. The measured energy spectra of protons and helium are power laws with exponents of 2.77 + or - 0.09 and 2.72 + or - 0.11 in the energy range 5 to 500 TeV and 2 to 50 TeV/amu, respectively. The proton spectrum shows no evidence of the steepening near 2 TeV which was reported by other experiments. Helium has a slightly higher intensity compared to extrapolations from lower energy measurements. The heavier elements, carbon to sulfur, show a small tendency for intensity enhancement in the relative abundance obove 10 TeV/amu.

Parnell, T. A.↗

The simulated features of heliospheric cosmic-ray modulation with a time-dependent drift model. III - General energy dependence

The time-dependent cosmic-ray transport equation is solved numerically in an axially symmetric heliosphere. Gradient and curvature drifts are incorporated, together with an emulated wavy neutral sheet. This model is used to simulate heliospheric cosmic-ray modulation for the period 1985-1989 during which drifts are considered to be important. The general energy dependence of the modulation of Galactic protons is studied as predicted by the model for the energy range 1 MeV to 10 GeV. The corresponding instantaneous radial and latitudinal gradients are calculated, and it is found that, whereas the latitudinal gradients follow the trends in the waviness of the neutral sheet to a large extent for all energies, the radial gradients below about 200 MeV deviate from this general pattern. In particular, these gradients increase when the waviness decreases for the simulated period 1985-1987.3, after which they again follow the neutral sheet by increasing rapidly.

Potgieter, M. S.↗

Thermal and Nonthermal Contributions to the Solar Flare X-Ray Flux

The relative thermal and nonthermal contributions to the total energy budget of a solar flare are being determined through analysis of RHESSI X-ray imaging and spectral observations in the energy range from approx. 5 to approx. 50 keV. The classic ways of differentiating between the thermal and nonthermal components - exponential vs. sources - can now be combined for individual flares. In addition, RHESSI's sensitivity down to approx. 4 keV and energy resolution of approx. 1 keV FWHM allow the intensities and equivalent widths of the complex of highly ionized iron lines at approx. 6.7 keV and the complex of highly ionized iron and nickel lines at approx. 8 keV to be measured as a function of time. Using the spectral line and continuum intensities from the Chianti (version 4.2) atomic code, the thermal component of the total flare emission can be more reliably separated from the nonthermal component in the measured X-ray spectrum. The abundance of iron can also be determined from RHESSI line-to-continuum measurements as a function of time during larger flares. Results will be shown of the intensity and equivalent widths of these line complexes for several flares and the temperatures, emission measures, and iron abundances derived from them. Comparisons will be made with 6.7-keV Fe-line fluxes measured with the RESIK bent crystal spectrometer on the Coronas-F spacecraft operating in third order during the peak times of three flares (2002 May 31 at 00:12 UT, 2002 December 2 at 19:26 UT, and 2003 April 26 at 03:OO UT). During the rise and decay of these flares, RESIK was operating in first order allowing the continuum flux to be measured between 2.9 and 3.7 keV for comparison with RHESSI fluxes at its low-energy end.

Dennis, Brian R.↗

AMEGO-X: MeV Gamma-Ray Astronomy in the Multimessenger Era

Recent detections of gravitational wave signals and neutrinos from gamma-ray sources have ushered in the era of multi-messenger astronomy, while highlighting the importance of gamma-ray observations for this emerging field. AMEGO-X, the All-sky Medium Energy Gamma-Ray Observatory eXplorer, is an MeV gamma-ray instrument that will survey the sky in the energy range from hundreds of keV to one GeV with unprecedented sensitivity. AMEGO-X will detect gamma-ray photons both via Compton interactions and pair production processes, bridging the “sensitivity gap” between hard X-rays and high-energy gamma rays. AMEGO-X will provide important contributions to multi-messenger science and time-domain gamma-ray astronomy, studying e.g. high-redshift blazars, which are probable sources of astrophysical neutrinos, and gamma-ray bursts. I will present an overview of the instrument and science program.

Henrike Fleischhack↗

Comparing X-ray Color Selection in Separating X-ray Binary Classes using Color-Color-Intensity Diagrams

X-ray binaries exhibit a wide range of properties but there are few accepted methods to determine the nature of the compact object. Color-Color-Intensity diagrams have been suggested as a means of distinguishing between systems containing black holes from those containing neutron stars. However, this technique has been verified with data from only one instrument (RXTE/ASM) with a single set of X-ray colors defined using data available only in pre-determined energy bands. We test a selection of X-ray colors with a more sensitive instrument to determine the reliability of this method. We use data from the MAXI/Gas Slit Camera, which allows users to specify energy-bands. We test X-ray colors that have been previously defined in the literature as well as ones that we define specifically in this paper. A representative set of systems are used to construct Color-Color-Intensity diagrams in each set of colors to determine which are best for separating different classes. For studying individual sources certain bands are more effective than others. For a specified energy range, the separation of soft states in black hole binaries was possible only where both soft and hard colors included information from the lowest energy band. We confirm that Color-Color-Intensity diagrams can distinguish between systems containing black holes or neutron stars in all X-ray colors tested; this suggests an universality in the accretion processes governing these different classes. We suggest possible physical processes driving different classes of X-ray binaries to different locations in Color-Color-Intensity diagrams.

N Islam↗

Continuum radiated power density $(P^{\textrm{C}}_{\textrm{rad}})$ and effective charge $(Z_{\textrm{eff}})$ estimates from multi-energy photon-counting measurements

Multi-energy soft x-ray pinhole cameras have been designed, built, calibrated, and operated at Madison symmetric Torus, Alcator C-Mod, and more recently at Tokamak a configuration variable and Tungsten Environment in Steady-State Tokamak (WEST), to measure plasma emission across multiple energy ranges. Here we describe a new methodology to estimate the local continuum radiated power density and the plasma effective charge (Z eff ) directly from photon-counting measurements of the line-free continuum emission (Bremsstrahlung and Radiative Recombination) in several energy bands between 11 and 18 keV. This capability is particularly valuable for confinement systems using metal plasma-facing components, where x-ray losses from interactions with the sputtered wall can represent a significant fraction of the total radiated power (P rad ). The approach leverages a well-characterized detector responsivity, modeled by a complementary error function, and interprets the differential multi-energy measurements between adjacent energy levels through the probability density function of a Gaussian distribution. The implementation of this diagnostic technique is currently under development on the WEST tokamak, aiming at the goal of providing real-time P rad and Z eff measurements during long-pulse operation (up to 1000 s) in the 2026 campaign.

WEST↗

An approach to light distribution for the calibration of high energy physics calorimeters

In high energy physics experiments, calorimeters are calibrated to produce precise and accurate results. Laser light can be used for calibration when the detectors are sensitive to photons in that particular energy range, which is often the case. Moreover, it is not unusual that detection systems consist of hundreds of channels that have to be calibrated independently, which produce stringent requirements on the light distribution system in terms of temporal and spatial stability, energy distribution and timing. Furthermore, the economic factor and the ease of production have to be taken into account. Overall, we present a prototype light distribution system, based on a series of optical beamsplitters, developed for the Muon g-2 experiment at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy micrometre-scale pixel direct conversion X-ray detector

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

36 MATERIALS SCIENCE↗

Recent Cross-Section Results from MicroBooNE

MicroBooNE is a liquid argon time projection chamber in the Booster Neutrino Beam at Fermilab. The large event rate and 3 mm wire spacing of the detector provide high-statistics, precise-resolution imaging of neutrino interactions leading to low-threshold, high-efficiency event reconstruction with full angular coverage. As such, this is an ideal place to probe neutrino-argon interactions in the hundreds-of-MeV to few-GeV energy range, and to study the impact of nuclear effects through detailed measurements of hadronic final states. These proceedings present recent measurements of neutrino interactions in MicroBooNE, including inclusive charged-current interactions, neutral-pion production, and measurements of low-energy protons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of a celestial Thomson-scattering X-ray polarimeter.

A general discussion of the scientific importance and status of stellar X-ray polarimetry is presented. A stellar X-ray polarimeter designed to fit into the bottom half of the NASA OSO-1 wheel compartment or other similar spacecraft is described. In this design, the linear polarization is obtained as a function of energy. The sensitivity of the polarimeter in the 4-24 keV energy range was optimized with the aid of a Monte Carlo simulation computer program and is given for several important celestial X-ray sources. Estimates of sensitivity thresholds for a much larger polarimeter, suitable for flight in the NASA High-Energy Astronomy Observatory (HEAO), are also given. The minimum detectable polarization for several X-ray sources is given.

Landecker, P. B.↗

Stopping pions in high-energy nuclear cascades.

Results of Monte Carlo calculations for the number and energy spectra of charged pions from nuclear-electromagnetic cascades developing in rock are presented for primary hadron energies ranging from 3 to 3000 GeV. These spectra are given as functions of the longitudinal depth in the absorber and the lateral distance from the cascade axis. The number of charged pions which stop in the absorber increases with the primary energy of the hadron initiating the cascade.

Jones, W. V.↗

Survey of He(+)/He(2+) abundance ratios in energetic particle events

The helium charge distribution in the energy range 0.4 to 0.62 MeV/nucleon in energetic particle events was studied. An average He+/He2+ ratio of 0.12 + or - 0.04 with ratios exceeding 0.3 for 41 out of 420 days events richest in He+ and no significant differences of the proton energy spectra, and the abundance of helium relative to protons and heavy ions for He+ rich events (He+/He2+ 0.3) and for events with He+/He2+ 0.3, respectively. It is also found that He+ rich events are predominantly low in energetic particle intensity.

Hovestadt, D.↗

A position-sensitive germanium detector for gamma-ray astronomy

The critical problem in high-resolution cosmic gamma-ray spectroscopy in the energy range from 0.02 to 10 MeV is the limited spectral sensitivity of the detectors used. This results from the small effective area of the detectors and the high background noise due to induced radioactivity and scattering in the detectors' high-energy particle environment. The effective area can be increased by increasing the number of detectors, but this becomes prohibitive because of the size and expense of the resulting instrument. We have taken a new approach: a segmented large-volume germanium gamma-ray detector which can effectively discriminate against internal background yet maintain the high spectral resolution and efficiency of conventional coaxial Ge detectors. To verify this concept, a planar detector divided into two segments has been fabricated and laboratory measurements agree well with Monte Carlo calculations. A large coaxial detector which will be divided into five segments is being built using the techniques developed for the planar detector. Monte Carlo calculations show that the sensitivity (minimum detectable flux) of the segmented coaxial detector is a factor of 2-3 better than conventional detectors because of the reduction in the internal background.

Varnell, L. S.↗

Laboratory electron exposure of TSS-1 thermal control coating

RM400, a conductive thermal control coating, was developed for use on the exterior shell of the tethered satellite. Testing was performed by the Engineering Physics Division to quantify effects of the space environment on this coating and its conductive and optical properties. Included in this testing was exposure of RM400 to electrons with energies ranging from 0.1 to 1 keV, to simulate electrons accelerated from the ambient space plasma when the tethered satellite is fully deployed. During this testing, the coating was found to luminesce, and a prolonged exposure of the coating to high-energy electrons caused the coating to darken. This report describes the tests done to quantify the degradation of the thermal control properties caused by electron exposure and to measure the luminescence as a function of electron energy and current density to the satellite.

Vaughn, J. A.↗

EGRET/COMPTEL Observations of an Unusual, Steep-Spectrum Gamma-Ray Source

During analysis of sources below the threshold of the third EGRET catalog, we have discovered a source, named GRO J1400-3956 based on the best position, with a remarkably steep spectrum. Archival analysis of COMPTEL data shows that the spectrum must have a strong turn-over in the energy range between COMPTEL and EGRET. The EGRET data show some evidence of time variability, suggesting an AGN, but the spectral change of slope is larger than that seen for most gamma-ray blazars. The sharp cutoff resembles the high-energy spectral breaks seen in some gamma-ray pulsars. There have as yet been no OSSE observations of this source.

Thompson, D. J.↗

SIFTER: Scintillating Fiber Telescopes for Energetic Radiation, Gamma-Ray Applications

The research project "SIFTER: Scintillating Fiber Telescopes for Energetic Radiation, Gamma-Ray Applications" approved under the NASA High Energy Astrophysics Research Program. The principal investigator of the proposal was Prof. Geoffrey N. Pendleton, who is currently on extended leave from UAH. Prof. William S. Paciesas administered the grant during Dr. Pendleton's absence. The project was originally funded for one year from 6/8/2000 to 6/7/2001. Due to conflicts with other commitments by the PI, the period of performance was extended at no additional cost until 6/30/2002. The goal of this project was to study scintillating fiber pair-tracking gamma-ray telescope configurations specifically designed to perform imaging and spectroscopy in the 5 - 250 MeV energy range. The main efforts were concentrated in two areas: 1) development of tracking techniques and event reconstruction algorithms, with particular emphasis on angular resolution; and 2) investigation of coded apertures as a means to improve the instrument angular resolution at low energies.

Paciesas, William S.↗

Measurements on the shuttle of the LET spectra of galactic cosmic radiation and comparison with the radiation transport model

A new class of tissue-equivalent proportional counters has been flown on two space shuttle flights. These detectors and their associated electronics cover a lineal energy range from 0.4 to 1250 keV/microns with a multichannel analyzer resolution of 0.1 keV/microns from 0.4 to 20 keV/microns and 5 keV/microns from 20 to 1250 keV/microns. These detectors provide the most complete dynamic range and highest resolution of any technique currently in use. On one mission, one detector was mounted in the Shuttle payload bay and another older model in the mid-deck, thus providing information on the depth dependence of the lineal energy spectrum. A detailed comparison of the observed lineal energy and calculated LET spectra for galactic cosmic radiation shows that, although the radiation transport models provide a rather accurate description of the dose (+/- 15%) and equivalent dose (+/- 15%), the calculations significantly underestimate the frequency of events below about 100 keV/microns. This difference cannot be explained by the inclusion of the contribution of splash protons. The contribution of the secondary pions, kaons and electrons produced in the Shuttle shielding, if included in the radiation transport model, may explain these differences. There are also significant differences between the model predictions and observations above 140 keV/microns, particularly for 28.5 degrees inclination orbit.

NASA Discipline Radiation Health↗