Operation Fishbowl

Fishbowl’s primary objective was to generate data on electromagnetic pulses (EMP), the creation and behavior of auroras, and the impact of a high altitude nuclear burst on radio communications. Previous high altitude tests (Teak, Orange, and Yucca) were not instrumented to provide such data, which was deemed critical to countering any Soviet high altitude bursts. The first test of Fishbowl, Starfish Prime, exploded on July 9th with a yield of 1.4 megatons. Standing on Christmas Island, Austin McGuire witnessed the effects of the event.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The interpretation of spectral data

The characteristics and extent of data which is obtainable by electromagnetic spectrum sensing and the application to earth resources survey are discussed. The wavelength and frequency ranges of operation for various remote sensors are tabulated. The spectral sensitivities of various sensing instruments are diagrammed. Examples of aerial photography to show the effects of lighting and seasonal variations on earth resources data are provided. Specific examples of multiband photography and multispectral imagery to crop analysis are included.

Holter, M. R.↗

Electromagnetic bias of 36-GHz radar altimeter measurements of MSL

The data reduction techniques used to determine the magnitude of electromagnetic (EM) bias in radar altimeter measurements of mean sea level (MSL) area described. Particular attention is given to the bias reduction scheme developed specifically for the Surface Contour Radar (SCR) instrument of the Ocean Topography Experiment (TOPEX). The SCR makes it possible to determine the amount of the backscattered power due to EM reflectance per unit area by measuring both the return power and elevation. Variations of backscattered power for different sea states are determined as a function of displacement of the MSL. On the basis of the recent SCR observations from aircraft, a standard error due to EM bias is predicted for MSL measurements performed with a satellite altimeter radar operating at a frequency of 36 GHz. The obtained standard error was 1 percent for regions with waves 1.9-5.5 meters in height.

Walsh, E. J.↗

Magnetospheric Image Unfolding

The Grant was a three year grant funded under the Space Physics Supporting Research and Technology and Suborbital Program. Our objective was to develop automated techniques needed to unfold or "invert" global images of the magnetospheric ion populations obtained by the new magnetospheric imaging techniques (ENA, EUV) in anticipation of future missions such as the Magnetospheric Imager and, now, IMAGE. Our focus on the present three year grant is to determine the degree to which such images can quantitatively constrain the global electromagnetic properties of the magnetosphere. In a previous three year grant period we successfully automated a forward modeling inversion algorithm, demonstrated that these inversions are robust in the face of realistic instrumental considerations such as counting statistics and backgrounds, applied error analysis techniques to the extracted parameters using variational procedures, implemented very realistic magnetospheric test images to test the inversion algorithms using the Rice University Magnetospheric Specification Model, and began the process of generating parametric models with the flexibility to handle the realistic magnetospheric images (e.g. Roelof et al, 1992; 1993). Our plan for the present 3 year grant period was to complete the development of the inversion tools needed to handle realistic magnetospheric images, assess the degree to which global electrodynamics is quantitatively constrained by ENA images of the magnetosphere, and bring the inversion of EUV images up to the maturity that we will have achieved for the ENA imaging. Below the accomplishments of our three year effort are present followed by a list of our presentations and publications. The accomplishments of all three years are presented here, and thus some of these items appeared on interim progress reports.

Source record↗

Application of Aura OMI L2G Products Compared with NASA MERRA-2 Assimilation

The Ozone Monitoring Instrument (OMI) is one of the instruments aboard NASA's Aura satellite. It measures ozone total column and vertical profile, aerosols, clouds, and trace gases including NO2, SO2, HCHO, BrO, and OClO using absorption in the ultraviolet electromagnetic spectrum (280 - 400 nm). OMI Level-2G (L2G) products are based on the pixel-level OMI granule satellite measurements stored within global 0.25 deg. X 0.25 deg. grids, therefore they conserve all the Level 2 (L2) spatial and temporal details for 24 hours of scientific data in one file. The second Modern-Era Retrospective analysis for Research and Applications (MERRA-2) is NASA's atmospheric reanalysis, using an upgraded version of Goddard Earth Observing System Model, version 5 (GEOS-5) data assimilation system. MERRA-2 includes aerosol data reanalysis and improved representations of stratospheric ozone, compared with its predecessor MERRA, in both instantaneous and time-averaged collections. It is found that simply comparing satellite Level-3 products might cause biases, due to lack of detailed temporal and original retrieval information. It is therefore preferable to inter-compare or implement satellite derived physical quantities directly with/to model assimilation with as high temporal and spatial resolutions as possible. This study will demonstrate utilization of OMI L2G daily aerosol and ozone products by comparing them with MERRA-2 hourly aerosol/ozone simulations, matched in both space and time aspects. Both OMI and MERRA-2 products are accessible online through NASA Goddard Earth Sciences Data Information Services Center (GES DISC, https://disc.gsfc.nasa.gov/).

OMI L2G products↗

Single Crystal Diamond Beam Position Monitors with Radiofrequency Electronic Readout

Over the energy range 5{approx}30 keV a suitably contacted, thin ({approx}100 {mu}m) diamond plate can be operated in situ as a continuous monitor of X-ray beam intensity and position as the diamond absorbs only a small percentage of the incident beam. Single crystal diamond is a completely homogeneous material showing fast (ns), spatially uniform signal response and negligible (<pA) leakage currents. Due to its unsurpassed thermal conductivity, it is the only semiconductor material that can be used in intense synchrotron white beams. We report on tests made at ESRF and DESY using diamond beam position monitors of simple quadrant electrode designs with metal contacts, operated using wideband electronic readout corresponding to the RF accelerator frequency. The instrumentation for these monitors must cover a large range of operating conditions: different beam sizes, fluxes, energies and time structure corresponding to the synchrotron fill patterns. Sophisticated new RF sampling electronics can satisfy most requirements: using a modified Libera Brilliance readout system, we measured the center of gravity position of a 25 {mu}m beam at the DORIS III F4 beam line at a rate of 130 Msample/s with narrowband filtering of a few MHz bandwidth. Digitally averaging the signal further provided a spatial resolution {approx}20 nm.

43 PARTICLE ACCELERATORS↗

A compact, multichannel, and low noise arbitrary waveform generator

A new type of high functionality, fast, compact, and easy programmable arbitrary waveform generator for low noise physical measurements is presented. The generator provides 7 fast differential waveform channels with a maximum bandwidth up to 200 MHz frequency. There are 6 fast pulse generators on the generator board with 78 ps time resolution in both duration and delay, 3 of them with amplitude control. The arbitrary waveform generator is additionally equipped with two auxiliary slow 16 bit analog-to-digital converters and four 16 bit digital-to-analog converters for low frequency applications. Electromagnetic shields are introduced to the power supply, digital, and analog compartments and with a proper filter design perform more than 110 dB digital noise isolation to the output signals. All the output channels of the board have 50 Ω SubMiniature version A termination. The generator board is suitable for use as a part of a high sensitive physical equipment, e.g., fast read out and manipulation of nuclear magnetic resonance or superconducting quantum systems and any other application, which requires electromagnetic interference free fast pulse and arbitrary waveform generation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of 95 GHz gyrotron based on continuous operation copper solenoid with water cooling

The design work for 2nd harmonic 95 GHz, 50 kW gyrotron based on continuous operation copper solenoid is presented. Thermionic magnetron injection gun specifications were calculated according to the linear trade off equation, and simulated with CST program. Numerical code is used for cavity design using the non-uniform string equation as well as particle motion in the “cold” cavity field. The mode TE02 with low Ohmic losses in the cavity walls was chosen as the operating mode. The Solenoid is designed to induce magnetic field of 1.8 T over a length of 40 mm in the interaction region with homogeneity of ±0.34%. The solenoid has six concentric cylindrical segments (and two correction segments) of copper foil windings separated by water channels for cooling. The predicted temperature in continuous operation is below 93 °C. The parameters of the design together with simulation results of the electromagnetic cavity field, magnetic field, electron trajectories, and thermal analyses are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Post-assembly magnetization of a 100 kW high speed permanent magnet rotor

A post-assembly magnetizing fixture has been designed and successfully used to magnetize the rotor of a 100 kW high speed permanent magnet synchronous motor. The rotor is a solid cylinder with outer diameter of 80 mm and total length of 515 mm. The permanent magnet material is samarium-cobalt (Sm{sub 2}Co{sub 17}) with saturation magnetizing field of 6 T. The mechanical stability of the magnetizing fixture has been studied as well as the general design methodology. The magnetizing coil is subdivided in order to reduce the electromagnetic force, and the coils are separately reinforced in different ways. The electromagnetic and structural optimization is performed by finite element analysis and verified by experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise cancellation in magnetoencephalography and electroencephalography with isolated reference sensors

An apparatus measures electromagnetic signals from a weak signal source. A plurality of primary sensors is placed in functional proximity to the weak signal source with an electromagnetic field isolation surface arranged adjacent the primary sensors and between the weak signal source and sources of ambient noise. A plurality of reference sensors is placed adjacent the electromagnetic field isolation surface and arranged between the electromagnetic isolation surface and sources of ambient noise.

47 OTHER INSTRUMENTATION↗

Launch Vehicle and Spacecraft Transmitter Electromagnetic Compatibility

The Launch Services Program at NASA’s Kennedy Space Center (KSC) is the primary gate for acquiring commercial vehicles to provide a cost effective ride to space for NASA spacecraft. With the lunar Gateway, more human tended elements are planned for launch. One challenge facing the space industry is the proliferation of communication and science transmitters at frequencies beyond the qualification of space avionics and instruments. Studies have ensued to examine the intricacies of performing radiated susceptibility testing and analysis above 18 GHz. Changes in the launch vehicle communications interface to the range have also lead to new launch vehicle antenna systems and more reliance on GPS and telemetry systems. Finally, research initiated at KSC in the area of predicted electric field distributions in launch vehicle payload fairings have spawned Small Business Technology Transfer initiatives for industry to investigate statistical algorithm and computational improvements in large payload fairing modeling of transmitters at frequencies in the GHz range. These topics, along with electromagnetic compatibility testing for launch vehicles will be discussed.

Electromagnetic Testing Cavity Statistics↗

Half-Cell RF Gun Simulations with the Electromagnetic Particle-in-Cell Code VORPAL

We have simulated Brookhaven National Laboratory's half-cell superconducting RF gun design for a proposed high-current ERL using the three-dimensional, electromagnetic particle-in-cell code VORPAL. VORPAL computes the fully self-consistent electromagnetic fields produced by the electron bunches, meaning that it accurately models space-charge effects as well as bunch-to-bunch beam loading effects and the effects of higher-order cavity modes, though these are beyond the scope of this paper. We compare results from VORPAL to the well-established space-charge code PARMELA, using RF fields produced by SUPERFISH, as a benchmarking exercise in which the two codes should agree well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic Design of a Magnetically-Coupled Spatial Power Combiner

The design of a two-dimensional beam-combining network employing a parallel-plate superconducting waveguide with a mono-crystalline silicon dielectric is presented. This novel beam-combining network structure employs an array of magnetically coupled antenna elements to achieve high coupling efficiency and full sampling of the intensity distribution while avoiding diffractive losses in the multi-mode region defined by the parallel-plate waveguide. These attributes enable the structures use in realizing compact far-infrared spectrometers for astrophysical and instrumentation applications. When configured with a suitable corporate-feed power-combiner, this fully sampled array can be used to realize a low-sidelobe apodized response without incurring a reduction in coupling efficiency. To control undesired reflections over a wide range of angles in the finite-sized parallel-plate waveguide region, a wideband meta-material electromagnetic absorber structure is implemented. This adiabatic structure absorbs greater than 99 of the power over the 1.7:1 operational band at angles ranging from normal (0 degree) to near parallel (180 degree) incidence. Design, simulations, and application of the device will be presented.

Bulcha, B.↗

Low-noise pulsed pre-polarization magnet system for ultra-low field NMR

A liquid cooled, pulsed electromagnet of solenoid configuration suitable for duty in an ultra-low field nuclear magnetic resonance system has been designed, fabricated and successfully operated. The magnet design minimizes Johnson noise, minimizes the hydrogen signal and incorporates minimal metal and no ferromagnetic materials. In addition, an acoustically quiet cooling system permitting 50% duty cycle operation was achieved by designing for single-phase, laminar flow, forced convection cooling. Winding, conductor splicing and epoxy impregnation techniques were successfully developed to produce a coil winding body with integral cooling passageways and adequate structural integrity. Issues of material compatibility, housing, coolant flow system and heat rejection system design will be discussed. Additionally, this pulsed electromagnet design has been extended to produce a boiling liquid cooled version in a paired solenoid configuration suitable for duty in an ultra-low field nuclear magnetic resonance system. This pair of liquid nitrogen cooled coils is currently being tested and commissioned. Issues of material compatibility, thermal insulation, thermal contraction, housing and coolant flow design are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigations of changes in the rate of beta decay of radioactive elements

Changes in the rate of the beta decay of radioactive elements whose periods are about 24 h and 27 d are detected on the basis of long-term investigations performed with the aid of scintillation and germanium-lithium gamma detectors. The use of the scintillation procedure yields results whose level of significance is much higher than 5%, while the procedure based on germanium-lithium detectors gives a more than 1% deviation from the average value of fluxes of gamma rays accompanying, for example, {sup 60}Co beta decay. With allowance for the rotation of the laboratory frame together with the Earth, deviations of the change in the rate of beta decay of radioactive elements single out three directions in the physical space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Fiber Optic Sensing Arrays with Enhanced Sensitivity in Cryogenic Temperatures

State-of-the-art instrumentation techniques have provided an opportunity to obtain greater insight into the characteristics of cryogenic liquid storage. Optical fiber sensors that utilize fiber Bragg gratings are a viable option for temperature sensing in volatile liquid such as liquid oxygen because there is no risk of electrical sparking and no electromagnetic interference. The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (Edwards, California) has developed a novel, simple-to-fabricate fiber array sensor that has been tested and found to be three times more sensitive than typical fiber sensors under cryogenic condition (traditional fiber sensors can suffer from reduced sensitivity below 100 K). Cryogenic temperature monitoring using the NASA fiber optic sensing system is demonstrated in a simulated cryostatic condition, as well as in an elevated pressure environment under liquid nitrogen. Measurement accuracy is compared with traditional silicon diodes. Instrument installation, sensor characteristics, and experimental results are discussed in detail.

Hon Man Chan↗

End-compensated magnetostatic cavity for polarized {sup 3}He neutron spin filters

We have expanded upon the ''Magic Box'' concept, a coil driven magnetic parallel plate capacitor constructed out of mu-metal, by introducing compensation sections at the ends of the box that are tuned to limit end-effects similar to those of short solenoids. This ability has reduced the length of the magic box design without sacrificing any loss in field homogeneity, making the device far more applicable to the often space limited neutron beam line. The appeal of the design beyond affording longer polarized {sup 3}He lifetimes is that it provides a vertical guide field, which facilitates neutron spin transport for typical polarized beam experiments. We have constructed two end-compensated magic boxes of dimensions 28.4x40x15 cm{sup 3} (lengthxwidthxheight) with measured, normalized volume-averaged transverse field gradients ranging from 3.3x10{sup -4} to 6.3x10{sup -4} cm{sup -1} for cell sizes ranging from 8.1x6.0 to 12.0x7.9 cm{sup 2} (diameterxlength), respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗