Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Fabrication and performance of AC-coupled LGADs

Detectors that can simultaneously provide fine time and spatial resolution have attracted wide-spread interest for applications in several fields such as high-energy and nuclear physics as well as in low-energy electron detection, photon science, photonics and imaging. Low-Gain Avalanche Diodes (LGADs), being fabricated on thin silicon substrates and featuring a charge gain of up to 100, exhibit excellent timing performance. Since pads much larger than the substrate thickness are necessary to achieve a spatially uniform multiplication, a fine pad pixelation is difficult. To overcome this limitation, the AC-coupled LGAD approach was introduced. In this type of device, metal electrodes are placed over an insulator at a fine pitch, and signals are capacitively induced on these electrodes. At Brookhaven National Laboratory, we have designed and fabricated prototypes of AC-coupled LGAD sensors. The performance of small test structures with different particle beams from radioactive sources are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-C-18A-11: Investigating the Minimum Scan Parameters Required to Generate Free-Breathing Fast-Helical CT Scans Without Motion-Artifacts

Purpose: A recently proposed 4D-CT protocol uses deformable registration of free-breathing fast-helical CT scans to generate a breathing motion model. In order to allow accurate registration, free-breathing images are required to be free of doubling-artifacts, which arise when tissue motion is greater than scan speed. This work identifies the minimum scanner parameters required to successfully generate free-breathing fast-helical scans without doubling-artifacts. Methods: 10 patients were imaged under free breathing conditions 25 times in alternating directions with a 64-slice CT scanner using a low dose fast helical protocol. A high temporal resolution (0.1s) 4D-CT was generated using a patient specific motion model and patient breathing waveforms, and used as the input for a scanner simulation. Forward projections were calculated using helical cone-beam geometry (800 projections per rotation) and a GPU accelerated reconstruction algorithm was implemented. Various CT scanner detector widths and rotation times were simulated, and verified using a motion phantom. Doubling-artifacts were quantified in patient images using structural similarity maps to determine the similarity between axial slices. Results: Increasing amounts of doubling-artifacts were observed with increasing rotation times > 0.2s for 16×1mm slice scan geometry. No significant increase in doubling artifacts was observed for 64×1mm slice scan geometry up to 1.0s rotation time although blurring artifacts were observed >0.6s. Using a 16×1mm slice scan geometry, a rotation time of less than 0.3s (53mm/s scan speed) would be required to produce images of similar quality to a 64×1mm slice scan geometry. Conclusion: The current generation of 16 slice CT scanners, which are present in most Radiation Oncology departments, are not capable of generating free-breathing sorting-artifact-free images in the majority of patients. The next generation of CT scanners should be capable of at least 53mm/s scan speed in order to use a fast-helical 4D-CT protocol to generate a motion-artifact free 4D-CT. NIH R01CA096679.

60 APPLIED LIFE SCIENCES↗

Classification Algorithm for Dark Matter Search using Skipper-CCD

In this project, I used ROOT framework with C++ for data analysis and Geant4 for simulating different particles’ interaction with the detector to study the characteristic of their tracks. I prepared the tagged dataset for machine learning training both the real experiment data taken in MINOS and simulation data from Geant4.

Chen, Meng-Wei↗

Proceedings of RIKEN BNL Research Center Workshop: Jet Observables at the Electron-Ion Collider (Volume 136) [Slides]

As the realization of an Electron Ion Collider (EIC) moves forward, efforts from the nuclear physics community continue to grow. In addition to the ongoing detector R&D efforts, plans for novel analysis topics must be demonstrated to aid in the detector designs, so that we can maximize the physics output of the EIC. This relies on input from both the experimental and theory communities. The aim of this workshop is to gather experts as well as those with a developing interest in the EIC so that theorists and experimentalists with experience measuring jets in a variety of hadronic collision systems can discuss the possible advantages and challenges of making measurements of jets in e+p and for the first time ever jets in e+A collisions at the EIC. In the time since the EIC white paper was written in 2011, there has been a growing recognition that jet observables could be a powerful probe of many of the physics topics which will be addressed by the EIC. Recent years have seen a multitude of both theoretical and experimental papers exploring the utility of jets for topics as diverse as determining the hadronic structure of photons, studying the 3D structure of the nucleon, and characterizing the properties of the matter found in nuclei. The aim of this workshop is to provide a forum for both theorists and experimentalists to discuss the possible advantages and challenges of jet measurements in e+p and e+A collisions at the EIC, learn about the status of necessary simulation tools, consider requirements on detector performance, and propose new ideas for jet observables and measurements. This proceedings report is a compilation of slides from the presentations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector configuration of DECIGO/BBO and identification of cosmological neutron-star binaries

The primary target for the planned space-borne gravitational wave interferometers DECIGO/BBO (Decihertz Interferometer Gravitational Wave Observatory/Big Bang Observer) is a primordial gravitational wave background. However there exist astrophysical foregrounds, and among them, gravitational waves from neutron-star (NS) binaries are the solid and strong component that must be identified and subtracted. In this paper, we discuss the geometry of detector configurations preferable for identifying the NS/NS binary signals. As a first step, we analytically estimate the minimum signal-to-noise ratios of the binaries for several static detector configurations that are characterized by adjustable geometrical parameters, and determine the optimal values for these parameters. Next we perform numerical simulations to take into account the effect of detector motions, and find reasonable agreements with the analytical results. We show that, with the standard network formed by 4 units of triangle detectors, the proposed BBO sensitivity would be sufficient in receiving gravitational waves from all the NS/NS binaries at z{<=}5 with signal-to-noise ratios higher than 25. We also discuss the minimum sensitivity of DECIGO required for the foreground identification.

79 ASTRONOMY AND ASTROPHYSICS↗

Turbulence modelling in neutron star merger simulations

Observations of neutron star mergers have the potential to unveil detailed physics of matter and gravity in regimes inaccessible by other experiments. Quantitative comparisons to theory and parameter estimation require nonlinear numerical simulations. However, the detailed physics of energy and momentum transfer between different scales, and the formation and interaction of small scale structures, which can be probed by detectors, are not captured by current simulations. This is where turbulence enters neutron star modelling. This review will outline the theory and current status of turbulence modelling for relativistic neutron star merger simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-210: The Variable Virtual Source-To-Axis Distance Effect On A Compact Proton Pencil Beam Scanning System

Purpose: We investigate the spot characteristic and dose profiles properties from a compact gantry proton therapy system. This compact design features a dedicated pencil beam scanning nozzle with the scanning magnet located upstream of the final 60 degree bending magnet. Due to the unique beam line design, uncertainty has been raised in the virtual source-to-axis distance (SAD). We investigate its potential clinical impact through measurements and simulation. Methods: A scintillator camera based detector was used to measure spot characteristics and position accuracy. An ion chamber array device was used to measure planar dose profile. Dose profile in-air simulation was performed using in-house built MATLAB program based on additional spot parameters directly from measurements. Spot characteristics such as position and in-air sigma values were used to general simulated 2D elliptical Gaussian spots. The virtual SAD distance changes in the longitudinal direction were also simulated. Planar dose profiles were generated by summation of simulated spots at the isocenter, 15 cm above the isocenter, and 15 cm below the isocenter for evaluation of potential clinical dosimetric impact. Results: We found that the virtual SAD varies depending on the spot location on the longitudinal axis. Measurements have shown that the variable SAD changes from 7 to 12 meters from one end to the other end of the treatment field in the longitudinal direction. The simulation shows that the planer dose profiles differences between the fixed SAD and variable SAD are within 3% from the isocenter profile and the lateral penumbras are within 1 mm difference. Conclusion: Our measurements and simulations show that there are minimum effects on the spot characteristics and dose profiles for this up-stream scanning compact system proton system. Further treatment planning study is needed with the variable virtual SAD accounted for in the planning system to show minimum dosimetric impact.

60 APPLIED LIFE SCIENCES↗

Using Cosmic Ray Muons to Assess Geological Characteristics in the Subsurface

Cosmic rays are energetic nuclei and elementary particles that originate from stars and intergalactic events. The interaction of these particles with the upper atmosphere produces a wide range of secondary particles that reach the surface of the earth, of which muons are the most prominent. With enough energy, muons can travel up to a few kilometers beneath the surface of the earth before being stopped completely. The terrestrial muon flux profile and associated zenith angle can be utilized to determine geological characteristics of a location (e.g., rock overburden and density) without having to use conventional methods such as boreholes. This work uses a low-power plastic scintillator-based muon detection system as a prototype for this non-destructive geological assay methodology. Four custom designed 102 cm x 51 cm x 5 cm plastic scintillation panels are used to realize two orthogonal detection planes. Optical photons from each scintillation panel are read using OnSemi J-Series 4x4 silicon photomultiplier (SiPM) arrays in conjunction with preamplifiers. Simultaneous triggers between detectors from two planes indicate a coincidence event which is recorded using the QuarkNet data acquisition system (DAQ) from Fermi National Accelerator Laboratory. A custom detector holder was designed to securely mount the detection system and rotate the panels along the zenith to collect data at variable angles. In order to quantify the systematic uncertainties associated with the detector, such as energy depositions and angular resolution of the detector design, a Monte Carlo (MC) simulation using Geant4 is being developed. Cosmic ray flux prediction will be included in the project by adding the CORSIKA MC code to the simulation toolchain. Simulated and experimental data will drive the development and validation of a reconstruction algorithm that, upon completion, is expected to predict average overburden and rock density. Extended detector exposure to muons can be used as a means to understand changes in the surrounding environment like rock porosity. On the experimental front, muons will initially be measured at the surface, establishing the baseline flux. This is followed by recording the muon flux at variable depths and zenith angles, where the data will be used by the reconstruction algorithm to predict the overburden. The result will be benchmarked against geological surveys. The measured flux data will also be used to benchmark independent and established models. Successful proof-of-concept demonstration of this technology can open doors for long term non-invasive geological monitoring. The detector design, experimental methodology, and the benchmarking efforts are detailed in this work.

Gadey, Harish Reddy↗

A Fluka study of underground cosmogenic neutron production

Neutrons produced by cosmic muon interactions are important contributors to backgrounds in underground detectors when searching for rare events. Typically such neutrons can dominate the background, as they are particularly difficult to shield and detect. Since actual data is sparse and not well documented, simulation studies must be used to design shields and predict background rates. Thus validation of any simulation code is necessary to assure reliable results. This work compares in detail predictions of the FLUKA simulation code to existing data, and uses this code to report a simulation of cosmogenic backgrounds for typical detectors embedded in a water tank with liquid scintillator shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-49: Simulation Study for Removing Scatter Radiation in Cesium-Iodine Based Flat Panel Detector System

Purpose: This study aims to identify the feasibility of a novel cesium-iodine (CsI)-based flat-panel detector (FPD) for removing scatter radiation in diagnostic radiology. Methods: The indirect FPD comprises three layers: a substrate, scintillation, and thin-film-transistor (TFT) layer. The TFT layer has a matrix structure with pixels. There are ineffective dimensions on the TFT layer, such as the voltage and data lines; therefore, we devised a new FPD system having net-like lead in the substrate layer, matching the ineffective area, to block the scatter radiation so that only primary X-rays could reach the effective dimension.To evaluate the performance of this new FPD system, we conducted a Monte Carlo simulation using MCNPX 2.6.0 software. Scatter fractions (SFs) were acquired using no grid, a parallel grid (8:1 grid ratio), and the new system, and the performances were compared.Two systems having different thicknesses of lead in the substrate layer—10 and 20μm—were simulated. Additionally, we examined the effects of different pixel sizes (153×153 and 163×163μm) on the image quality, while keeping the effective area of pixels constant (143×143μm). Results: In case of 10μm lead, the SFs of the new system (∼11%) were lower than those of the other system (∼27% with no grid, ∼16% with parallel grid) at 40kV. However, as the tube voltage increased, the SF of new system (∼19%) was higher than that of parallel grid (∼18%) at 120kV. In the case of 20μm lead, the SFs of the new system were lower than those of the other systems at all ranges of the tube voltage (40–120kV). Conclusion: The novel CsI-based FPD system for removing scatter radiation is feasible for improving the image contrast but must be optimized with respect to the lead thickness, considering the system’s purposes and the ranges of the tube voltage in diagnostic radiology. This study was supported by a grant(K1422651) from Institute of Health Science, Korea University.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposal to Search for Magnetically Charged Particles with Magnetic Charge 1e

A model for composite elementary Standard Model (SM) particles based upon magnetically bound vorton pairs, we briefly introduce here, predicts the existence of a complete family of magnetically charged particles, as well as their neutral isotopic partners (all counterparts to the SM elementary particles), in which the lowest mass (charged) particle would be an electrically neutral stable lepton, but which carries a magnetic charge equivalent to 1e. This new particle, which we call a magneticon (a counterpart to the electron) would be pair produced at all e + e - colliders at an E cm above twice its mass. In addition, PP and PPbar colliders should also be able to produce these new particles through the Drell-Yan process. To our knowledge, no monopole search experiment has been sensitive to such a low-charged magnetic monopole above a particle mass of about 5 GeV/c 2 . Hence, we propose that a search for such a stable particle of magnetic charge 1e should be undertaken. We have taken the ATLAS detector at the LHC as an example in which this search might be done. To this end, we modeled the magnetic fields and muon trigger chambers of this detector. We show results from a simple Monte Carlo simulation program to indicate how these particles might look in the detector and describe how one might search for these new particles in the ATLAS data stream.

ATLAS↗

Research and Development Studies for Reactor Neutrino Experiments in Turkey (RNET)

The program of the Reactor Neutrino Experiments of Turkey includes a small portable Water-based liquid scintillator detector to detect neutrinos from the Akkuyu nuclear power plant, planned to begin operating in 2023. The small near-field detector will weigh about 2-3 tons and will be placed less than 100 meters from the reactor cores. The Reactor Neutrino Experiments of Turkey program also includes a medium-size 30-ton Water-based liquid scintillator detector, which will be placed 1-2 km away from the reactor cores and will be used as a far detector. Both detectors and their responses to neutrino interactions were simulated using a GEANT4-based RAT-PAC simulation package. Here, we will share the technical and physical details of both detectors, and discuss the ongoing R&D effort for neutrino studies in Turkey.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Object detection with deep learning for rare event search in the GADGET II TPC

In the pursuit of identifying rare two-particle events within the GADGET II Time Projection Chamber (TPC), this paper presents a comprehensive approach for leveraging Convolutional Neural Networks (CNNs) and various data processing methods. To address the inherent complexities of 3D TPC track reconstructions, the data is expressed in 2D projections and 1D quantities. This approach capitalizes on the diverse data modalities of the TPC, allowing for the efficient representation of the distinct features of the 3D events, with no loss in topology uniqueness. Additionally, it leverages the computational efficiency of 2D CNNs and benefits from the extensive availability of pre-trained models. Given the scarcity of real training data for the rare events of interest, simulated events are used to train the models to detect real events. To account for potential distribution shifts when predominantly depending on simulations, significant perturbations are embedded within the simulations. This produces a broad parameter space that works to account for potential physics parameter and detector response variations and uncertainties. These parameter-varied simulations are used to train sensitive 2D CNN object detectors. When combined with 1D histogram peak detection algorithms, this multi-modal detection framework is highly adept at identifying rare, two-particle events in data taken during experiment 21072 at the Facility for Rare Isotope Beams (FRIB), demonstrating a 100% recall for events of interest. Here, we present the methods and outcomes of our investigation and discuss the potential future applications of these techniques.

Convolutional neural network↗

Gamma-Ray Simulated Spectrum Deconvolution of a LaBr₃ 1-in. x 1-in. Scintillator for Nondestructive ATR Fuel Burnup On-Site Predictions

A deconvolution method for a LaBr₃ 1"x1" detector for nondestructive Advanced Test Reactor (ATR) fuel burnup applications was developed. The method consisted of obtaining the detector response function, applying a deconvolution algorithm to 1”x1” LaBr₃ simulated, data along with evaluating the effects that deconvolution have on nondestructively determining ATR fuel burnup. The simulated response function of the detector was obtained using MCNPX as well with experimental data. The Maximum-Likelihood Expectation Maximization (MLEM) deconvolution algorithm was selected to enhance one-isotope source-simulated and fuel- simulated spectra. The final evaluation of the study consisted of measuring the performance of the fuel burnup calibration curve for the convoluted and deconvoluted cases. The methodology was developed in order to help design a reliable, high resolution, rugged and robust detection system for the ATR fuel canal capable of collecting high performance data for model validation, along with a system that can calculate burnup and using experimental scintillator detector data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interior micro-CT with an offset detector

Purpose: The size of field-of-view (FOV) of a microcomputed tomography (CT) system can be increased by offsetting the detector. The increased FOV is beneficial in many applications. All prior investigations, however, have been focused to the case in which the increased FOV after offset-detector acquisition can cover the transaxial extent of an object fully. Here, the authors studied a new problem where the FOV of a micro-CT system, although increased after offset-detector acquisition, still covers an interior region-of-interest (ROI) within the object. Methods: An interior-ROI-oriented micro-CT scan with an offset detector poses a difficult reconstruction problem, which is caused by both detector offset and projection truncation. Using the projection completion techniques, the authors first extended three previous reconstruction methods from offset-detector micro-CT to offset-detector interior micro-CT. The authors then proposed a novel method which combines two of the extended methods using a frequency split technique. The authors tested the four methods with phantom simulations at 9.4%, 18.8%, 28.2%, and 37.6% detector offset. The authors also applied these methods to physical phantom datasets acquired at the same amounts of detector offset from a customized micro-CT system. Results: When the detector offset was small, all reconstruction methods showed good image quality. At large detector offset, the three extended methods gave either visible shading artifacts or high deviation of pixel value, while the authors’ proposed method demonstrated no visible artifacts and minimal deviation of pixel value in both the numerical simulations and physical experiments. Conclusions: For an interior micro-CT with an offset detector, the three extended reconstruction methods can perform well at a small detector offset but show strong artifacts at a large detector offset. When the detector offset is large, the authors’ proposed reconstruction method can outperform the three extended reconstruction methods by suppressing artifacts and maintaining pixel values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Search for physics beyond the standard model in top quark production with additional leptons in the context of effective field theory

A search for new physics in top quark production with additional final-state leptons is performed using data collected by the CMS experiment in proton-proton collisions at $ \sqrt{s} $ = 13 TeV at the LHC during 2016–2018. The data set corresponds to an integrated luminosity of 138 fb$^{−1}$. Using the framework of effective field theory (EFT), potential new physics effects are parametrized in terms of 26 dimension-six EFT operators. The impacts of EFT operators are incorporated through the event-level reweighting of Monte Carlo simulations, which allows for detector-level predictions. The events are divided into several categories based on lepton multiplicity, total lepton charge, jet multiplicity, and b-tagged jet multiplicity. Kinematic variables corresponding to the transverse momentum (p$_{T}$) of the leading pair of leptons and/or jets as well as the p$_{T}$ of on-shell Z bosons are used to extract the 95% confidence intervals of the 26 Wilson coefficients corresponding to these EFT operators. No significant deviation with respect to the standard model prediction is found.[graphic not available: see fulltext]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of cosmogenic activation above ground for the DarkSide-20k experiment

The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39 Ar. Despite the outstanding capability of discriminating γ / β background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39 Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37 Ar and 3 H are shown not to be relevant due to short half-life and assumed purification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transverse profile of the electron beam for the RHIC electron lenses

To compensate for the beam-beam effects from the proton-proton interactions at the two interaction points IP6 and IP8 in the Relativistic Heavy Ion Collider (RHIC), we are constructing two electron lenses (e-lenses) that we plan to install in the interaction region IR10. Before installing them, the electron gun, collector, instrumentation were tested and the electron beam properties were qualified on an electron lens test bench. We will present the test results and discuss our measurement of the electron beam current and of the electron gun perveance. We achieved a maximum current of 1 A with 5 kV energy for both the pulsed- and the DC-beam (which is a long turn-by-turn pulse beam). We measured beam transverse profiles with an Yttrium Aluminum Garnet (YAG) screen and pinhole detector, and compared those to simulated beam profiles. Measurements of the pulsed electron beam stability were obtained by measuring the modulator voltage.

43 PARTICLE ACCELERATORS↗