Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DATA CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Time Series of Magnetic Field Parameters Extracted from Merged Space-Weather MDI/HMI Active Region Patches as Potential Tool for Solar Flare Forecasting

Space-Weather MDI Active Region Patches (SMARPs) and Space-Weather HMI Active Region Patches (SHARPs) are two recently developed data products, which have been used for solar flare prediction studies. The present work is an effort to expand the application of SMARP and SHARP summary heliomagnetic parameters to the forecasting of solar flares. A new data product was derived by filtering, rescaling, and merging the SMARP and SHARP summary parameter data series, which were further converted into two-dimensional arrays by selecting time slices corresponding to R-value maxima, where R-value is a measure of the unsigned magnetic flux near polarity inversion lines. The resulting combined MDI-HMI time series currently span the period between April 4, 1996 and December 13, 2022, and can be extended to a more recent date, providing an opportunity to correlate and compare them with other solar activity parameters, such as the daily solar flare index, which is computed as a sum of the product of GOES X-ray flare magnitude and flare duration, for all M- and X-class flares during a day. Preliminary results demonstrate a significant overall correlation, with Pearson coefficients between 0.339 and 0.627. In addition, an oscillating pattern is seen in the daily-averaged sliding-window correlation coefficient. Time-lagged cross-correlation indicates that a leader-follower dynamic exists in some parameters, especially R-value, where they lead the flare index by at least several days, which may have potential for further application in space weather forecasting.

Heliophysics↗

Implant for in-vivo parameter monitoring, processing and transmitting

The present invention relates to a completely implantable intracranial pressure monitor, which can couple to existing fluid shunting systems as well as other internal monitoring probes. The implant sensor produces an analog data signal which is then converted electronically to a digital pulse by generation of a spreading code signal and then transmitted to a location outside the patient by a radio-frequency transmitter to an external receiver. The implanted device can receive power from an internal source as well as an inductive external source. Remote control of the implant is also provided by a control receiver which passes commands from an external source to the implant system logic. Alarm parameters can be programmed into the device which are capable of producing an audible or visual alarm signal. The utility of the monitor can be greatly expanded by using multiple pressure sensors simultaneously or by combining sensors of various physiological types.

60 APPLIED LIFE SCIENCES↗

General Nuclear Date

Provides python rountines to convert ENDF-6 formatted nuclear data (4) into the new GND structure. Includes sample published ENDF-6 formatted data as well as published ENSL (5) and HDF5 file.

Source record↗

SU-E-J-72: Geant4 Simulations of Spot-Scanned Proton Beam Treatment Plans

Purpose: To evaluate density inhomogeneities which can effect dose distributions for real-time image gated spot-scanning proton therapy (RGPT), a dose calculation system, using treatment planning system VQA (Hitachi Ltd., Tokyo) spot position data, was developed based on Geant4. Methods: A Geant4 application was developed to simulate spot-scanned proton beams at Hokkaido University Hospital. A CT scan (0.98 × 0.98 × 1.25 mm) was performed for prostate cancer treatment with three or four inserted gold markers (diameter 1.5 mm, volume 1.77 mm3) in or near the target tumor. The CT data was read into VQA. A spot scanning plan was generated and exported to text files, specifying the beam energy and position of each spot. The text files were converted and read into our Geant4-based software. The spot position was converted into steering magnet field strength (in Tesla) for our beam nozzle. Individual protons were tracked from the vacuum chamber, through the helium chamber, steering magnets, dose monitors, etc., in a straight, horizontal line. The patient CT data was converted into materials with variable density and placed in a parametrized volume at the isocenter. Gold fiducial markers were represented in the CT data by two adjacent voxels (volume 2.38 mm3). 600,000 proton histories were tracked for each target spot. As one beam contained about 1,000 spots, approximately 600 million histories were recorded for each beam on a blade server. Two plans were considered: two beam horizontal opposed (90 and 270 degree) and three beam (0, 90 and 270 degree). Results: We are able to convert spot scanning plans from VQA and simulate them with our Geant4-based code. Our system can be used to evaluate the effect of dose reduction caused by gold markers used for RGPT. Conclusion: Our Geant4 application is able to calculate dose distributions for spot scanned proton therapy.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental Setup and Learning-Based AI Model for Developing Accurate PV Inverter Models

The integration of power electronics-based interfaces presents challenges due to the absence of detailed models and the high computational complexity. Generic models used in system studies lack accuracy in capturing converter dynamics. This paper proposes a data-driven approach developed from experimental setup data. This approach enhances accuracy in photovoltaic inverter modeling. We used two types of PV inverters in the experiment. The recorded experimental data undergo processing through a machine learning model. Results from the model trained through machine learning is also presented.

artificial intelligence↗

Recovery and calibration of legacy analog data from the Leo Brady Seismic Network for the Source Physics Experiment

The Leo Brady Seismic Network (LBSN) was established in 1960 by Sandia National Laboratories for monitoring underground nuclear tests (UGTs) at the Nevada Test Site— renamed in 2010 to the Nevada National Security Site (NNSS). The LBSN has been in various configurations throughout its existence, but it has been generally comprised of four to six stations at regional distances from the NNSS with evenly spaced azimuthal coverage. Between 1962 and the early 1980s, the LBSN—and a sister network operated by Lawrence Livermore National Laboratory—were the most comprehensive U.S. source of regional seismic data of UGTs. During the pre-digital era, LBSN data were transmitted as frequency-modulated (FM) audio over telephone lines to the NTS and recorded in analog on hi-fi 8-track AMPEX tapes. These tapes have been stored in temperature-stable buildings or bunkers on the NNSS and Kirtland Air Force Base in Albuquerque, NM for decades and contain the sole record of this irreplaceable data from the analog era; full waveforms of UGTs during this time were never routinely converted to digital form. We have been developing a process over the past few years to recover and calibrate data from these tapes, converting them from FM audio to digital waveforms in ground motion units. The calibration of legacy data from the LBSN is still ongoing. To date, we have digitized tapes from 592 separate UGTs. As a proof-of-concept, we calibrated data from the BOXCAR event.

58 GEOSCIENCES↗

Counter Unmanned Aircraft System Metrics Tool

SAND2023-05387O The Counter Unmanned Aircraft System (CUAS) Metrics Tool consists of three applications: • The Data Collection Tool is designed to be used during testing and captures details that can be imported into the Figure Creator application. • The Unmanned Aircraft System (UAS) Log Converter converts different UAS logs into a standardized hierarchical data format with a timeline of geospatial data. • The Figure Creator develops relevant images for the test event. The application includes logic to ingest and correlate data from the Data Collection Tool and the UAS Log Converter to produce the chosen figures. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Mayle, Ashley↗

Network device interface for digitally interfacing data channels to a controller via a network

The present invention provides a network device interface and method for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is then converted into digital signals and transmitted back to the controller. In one embodiment, the bus controller sends commands and data a defined bit rate, and the network device interface senses this bit rate and sends data back to the bus controller using the defined bit rate.

Ellerbrock, Philip J.↗

Multi-resonant switched capacitor power converter architecture

A switched-capacitor (SC) network in an SC converter is controlled to operate at varying resonant modes to achieve high conversion ratio efficiency, at a low circuit component count. These power converters are suited to numerous application areas including improving energy efficiency of data centers. A family of resonant switched capacitor (SC) converters with multiple operating phases are presented “Multi-Resonant SC Converters”. Described in detail are an 8-to-1 Multi-Resonant-Doubler (MRD) converter and a 6-to-1 Cascaded Series-Parallel (CaSP). The topology of these converters make them amenable to combining like units in parallel toward reaching higher power levels.

Ye, Zichao↗

Quantitative measurements of Jupiter, Saturn, their rings and satellites made from Voyager imaging data

The Voyager spacecraft cameras use selenium-sulfur slow scan vidicons to convert focused optical images into sensible electrical signals. The vidicon-generated data thus obtained are the basis of measurements of much greater precision than was previously possible, in virtue of their superior linearity, geometric fidelity, and the use of in-flight calibration. Attention is given to positional, radiometric, and dynamical measurements conducted on the basis of vidicon data for the Saturn rings, the Saturn satellites, and the Jupiter atmosphere.

Collins, S. A.↗

BSEC flux towers: CSAT3B and TRH

The data were collected as part of the BSEC project, during the period from June 2025 to May 2026. Directory "broadway" contains data collected on a multi-level flux tower (US-BWf) in the Broadway East neighborhood (1808 North Patterson Park Ave., Baltimore City, MD 21213; LAT: 39o18'40.31'' N; LONG: 76o35'12.43'' W). At each of the four measurement heights (8.5 m, 11.1 m, 13.4 m, 15.9 m), a Campbell Scientific CSAT3B sonic anemometer was operated at 50 Hz to measure virtual temperature (tc) and three velocity components (u: 270 degrees; v: 180 degrees; w: vertical), and a RM Young temperature sensor (model 41382VC) was operated at 1 Hz inside a compact aspirated radiation shield (model 43502) to measure absolute temperature (T) and relative humidity (RH). Inside directory "broadway", directory "netcdf" contains data collected each day in 5-minute chunks that have been converted to NetCDF format (before quality checking), while "4hr" contains data arranged into 4-hour chunks (also in NetCDF format) that have been through basic quality checking steps (treating data points with nonzero diagnostic codes as missing data; fixing six or fewer consecutive missing data points using linear interpolation). Users are recommended to start with data in directory "4hr", while data in directory "netcdf" can be used for reference purposes.

Baltimore↗

XML Flight/Ground Data Dictionary Management

A computer program generates Extensible Markup Language (XML) files that effect coupling between the command- and telemetry-handling software running aboard a spacecraft and the corresponding software running in ground support systems. The XML files are produced by use of information from the flight software and from flight-system engineering. The XML files are converted to legacy ground-system data formats for command and telemetry, transformed into Web-based and printed documentation, and used in developing new ground-system data-handling software. Previously, the information about telemetry and command was scattered in various paper documents that were not synchronized. The process of searching and reading the documents was time-consuming and introduced errors. In contrast, the XML files contain all of the information in one place. XML structures can evolve in such a manner as to enable the addition, to the XML files, of the metadata necessary to track the changes and the associated documentation. The use of this software has reduced the extent of manual operations in developing a ground data system, thereby saving considerable time and removing errors that previously arose in the translation and transcription of software information from the flight to the ground system.

Wright, Jesse↗

SU-E-I-27: Establishing Target Exposure Index Values for Computed Radiography

Purpose: To develop a standard set of target exposure index (TEI) values to be applied to Agfa Computed Radiography (CR) readers in accordance with International Electrotechnical Committee 62494-1 (ed. 1.0). Methods: A large data cohort was collected from six USAF Medical Treatment Facilities that exclusively use Agfa CR Readers. Dose monitoring statistics were collected from each reader. The data was analyzed based on anatomic region, view, and processing speed class. The Agfa specific exposure metric, logarithmic mean (LGM), was converted to exposure index (EI) for each data set. The optimum TEI value was determined by minimizing the number of studies that fell outside the acceptable deviation index (DI) range of +/− 2 for phototimed techniques or a range of +/−3 for fixed techniques. An anthropomorphic radiographic phantom was used to corroborate the TEI recommendations. Images were acquired of several anatomic regions and views using standard techniques. The images were then evaluated by two radiologists as either acceptable or unacceptable. The acceptable image with the lowest exposure and EI value was compared to the recommended TEI values using a passing DI range. Results: Target EI values were determined for a comprehensive list of anatomic regions and views. Conclusion: Target EI values must be established on each CR unit in order to provide a positive feedback system for the technologist. This system will serve as a mechanism to prevent under or overexposures of patients. The TEI recommendations are a first attempt at a large scale process improvement with the goal of setting reasonable and standardized TEI values. The implementation and effectiveness of the recommended TEI values should be monitored and adjustments made as necessary.

60 APPLIED LIFE SCIENCES↗

Electrical Resistivity and Seismic Surveys at the Nevada Test Site, Nevada, April 2007

In April 2007, the USGS collected direct-current (DC) electrical resistivity data and shear- (S) and compressional- (P) wave seismic data to provide new detail of previously mapped, overlapping fault splays at two administrative areas in the Nevada Test Site (NTS). In NTS Area 7, we collected two-dimensional DC resistivity data along a transect crossing the Yucca Fault parallel to, and between, two transects along which resistivity data were collected in a previous study in 2006. In addition, we collected three-dimensional DC resistivity data in a grid that overlies part of the 2007 transect. The DC resistivity data show that the fault has a footwall that is more conductive than the hanging wall and an along-strike progression of the fault in a location where overlapping splays are present. Co-located with the northernmost of the two 2006 DC resistivity transects, we acquired S- and P-wave seismic data for both reflection and refraction processing. The S-wave data are corrupted by large amounts of converted (P-wave) energy likely due to the abundance of fractured caliche in the shallow subsurface. The P-wave data show minimal reflected energy, but they show clear refracted first arrivals. We have inverted these first arrival times to determine P-wave seismic velocity models. The seismic model for the transect in Area 7 shows low velocities extending to the base of the model at the location of the Yucca Fault, as well as low velocities at the eastern end of the transect, in the vicinity of the adjacent crater. These new surveys provide further detail about the geometry of the Yucca Fault in this location where it shows two overlapping splays. We collected P- and S-wave seismic data along a transect in the southern part of NTS Area 2, corresponding with the location of a 2006 DC resistivity transect that targeted a set of small faults identified with field mapping. Again, the S-wave data are difficult to interpret. The P-wave data show clear first arrivals that we inverted, yielding a velocity model that shows lateral heterogeneity similar to the 2006 DC resistivity models. Finally, we collected P-wave data along a second transect in Area 2, located north of the first line and in an area of a very minor fault that was targeted by another 2006 DC resistivity survey. The P-wave refraction velocity model shows generally high velocities, with a zone of somewhat lower velocities in the central part of the transect. The position of the low velocity zone corresponds with the location of a minor fault, though it is unclear whether the two are related. Together, these results demonstrate the value of geophysical data for mapping the subsurface extent of faults. The 2007 DC resistivity data complement the 2006 data and provide important new detail of the overlapping fault splays. The seismic data demonstrate the ability of P-wave refraction methods to identify the damage zones at faults, and they show the difficulties associated with S-wave methods in areas with caliche. Combining all of the geophysical data from the Area 7 studies, we are able to develop a coherent interpretation of the relation between the site geology, the fault, and the observations.

58 GEOSCIENCES↗

HERO WEC Belt Test Data

The following submission includes raw and processed data from the 2024 Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC) belt tests conducted using NREL's Large Amplitude Motion Platform (LAMP). A description of the motion profiles run during testing can be found in the run log document. Data was collected using NREL's Modular Ocean Data AcQuisition (MODAQ) system in the form of TDMS files. Data was then processed using Python and MATLAB and converted to MATLAB workspace, parquet, and csv file formats. During Data processing, a low pass filter was applied to each array and the arrays were then resampled to common 10Hz timestamps. A MATLAB data viewer script is provided to quickly visualize these data sets. The following arrays are contained in each test data file: - Time: Unix seconds timestamp - Test_Time: Time in seconds since beginning of test - POS_OS_1001: Encoder position in degrees (the encoder is located on the secondary shaft of the spring return and is driven by the winch after a 4.5:1 gear reduction) - LC_ST_1001: Anchor load cell data in lbf - PRESS_OS_2002: Air spring pressure in psi This data set has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

N2-Cs thermionic converter development

The possibility of using molecular nitrogen gas additive as an energy storage which in turn produces cesium ionization in advanced thermionic converter is first described theoretically. Experimental data confirmed for the first time such cesium ionization by vibrationally excited molecular nitrogen. Based on these experimental observations, the use of this scheme for the verification of validity of the recent Lam's theory and its application for the development of an advanced flowing thermionic converter are discussed.

Shaw, D. T.↗

MO-AB-BRA-07: Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams

Purpose: We developed a pre-clinical prototype system for range verification of proton pencil-beam scanning fields. The system was evaluated using phantom treatment plans delivered with a clinical dose rate. Methods: The absolute range of proton pencil-beams was verified through an optimization procedure, which matches energy- and time-resolved prompt gamma-ray measurements with models, based on cross sections for discrete prompt gamma-ray line excitations. Phantom experiments were performed with a pre-clinical prototype detector, using treatment plans delivered with a clinical pencil-beam scanning system. The detector consisted of an actively shielded lanthanum(III) bromide scintillator. Tungsten was used to collimate the gamma-rays. To support high event rates, the detector readout featured custom amplifiers and an active voltage divider for the photomultiplier. The detector signals were acquired by fast analog-to-digital converters and processed using digital algorithms. The data acquisition was also synchronized with the pencil-beam scanning and dosimetry systems. Results: We successfully acquired prompt gamma-ray spectra during the delivery of proton pencil-beams with a clinical beam current of 2 nA at the exit of the treatment head. The number of events in the primary detector ranged from 1 x 10{sup 6} to 2 x 10{sup 6} per second. In phantom experiments, non-uniform range errors were introduced by placing strips of plastic in the beam path. The magnitudes and positions of these range errors were correctly detected in two-dimensional range maps that were generated from the measurements. With our small scale prototype, a 1.0 mm standard deviation on the absolute range required about 5 x 10{sup 8} protons per delivered pencil-beam. Conclusions: Prompt gamma-ray spectroscopy to verify the absolute range of proton beams was demonstrated under clinical pencil-beam delivery conditions. A 1 mm to 2 mm range verification accuracy for a field delivering 1 Gy, appears feasible with a full scale system. This work was supported by the Federal Share of program income earned on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗