Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Application of Synthetic Jets to Reduce Stator Flow Separation in a Low Speed Axial Compressor

Flow control using synthetic jet injection has been applied in a low speed axial compressor. The synthetic jets were applied from the suction surface of a stator vane via a span-wise row of slots pitched in the streamwise direction. Actuation was provided externally from acoustic drivers coupled to the vane tip via flexible tubing. The acoustic resonance characteristics of the system, and the resultant jet velocities were obtained. The effects on the separated flow field for various jet velocities and frequencies were explored. Total pressure loss reductions across the vane passage were measured. The effect of synthetic jet injection was shown to be comparable to that of pulsatory injection with mass addition for stator vanes which had separated flow. While only a weak dependence of the beneficial effect was noted based on the excitation frequency, a strong dependence on the amplitude was observed at all frequencies.

Braunscheidel, Edward P.↗

Performance of 15-Stage Experimental J71 Axial-Flow Compressor: II - Individual Stage Performance Characteristics

The first four stages were found to cause a major part of the poor low-speed efficiency of this compressor. The low design-speed over-all pressure ratio at surge was caused by the first and the twelfth to fifteenth stages. The multiple over-all performance curves in the intermediate-speed range were at least partly the result of double-branched characteristic curves for the third and seventh stages.

Lucas, James G.↗

Matching Characteristics of J35-A-23 Compressor and Two-stage Turbine

Component data on the J35-A-23 compressor and two-stage turbine were used to determine the problems in matching the two units for operatio n in a turbojet engine. Possible operating regions were determined an d an equilibrium operating line was also determined for the assumed c onditions of zero flight speed and a jet nozzle area approximately 5. 5 percent greater than the wide-open nozzle area.

Dugan, James F., Jr.↗

Vibration Survey of Blades in 19XB Axial-Flow Compressor: Preliminary Engine Investigation - 3

Strain gages were used to measure blade vibrations possibly causing failure in the 10-stage compressor of the 19XB jet-propulsion engine. The seventh and tenth stages were of great concern as a result of failures experienced by the manufacturer. Strain-gage records were obtained from all stages during acceleration, deceleration, and constant speed runs. Curves are presented herein showing the maximum allowable vibratory stress for a given speed, the change of the damping coefficient with the mounting of a strain gage at the base of the blade, the effect of rotor speed, on blade natural frequency, and the effect of the order of first bending-mode vibration on stress. It was found that for all stages the lower the order of vibration the higher the stress but no destructive vibrations were detected.

Meyer, Andre J., Jr.↗

Miniature high speed compressor having embedded permanent magnet motor

A high speed centrifugal compressor for compressing fluids includes a permanent magnet synchronous motor (PMSM) having a hollow shaft, the being supported on its ends by ball bearing supports. A permanent magnet core is embedded inside the shaft. A stator with a winding is located radially outward of the shaft. The PMSM includes a rotor including at least one impeller secured to the shaft or integrated with the shaft as a single piece. The rotor is a high rigidity rotor providing a bending mode speed of at least 100,000 RPM which advantageously permits implementation of relatively low-cost ball bearing supports.

Zhou, Lei↗

Orifice Mass Flow Calculation in NASA's W-8 Single Stage Axial Compressor Facility

Updates to the orifice mass flow calculation for the W-8 Single Stage Axial Compressor Facility at NASA Glenn Research Center are provided to include the effect of humidity and incorporate ISO 5167. A methodology for including the effect of humidity into the inlet orifice mass flow calculation is provided. Orifice mass flow calculations provided by ASME PTC-19.5-2004, ASME MFC-3M-2004, ASME Fluid Meters, and ISO 5167 are compared for W-8's atmospheric inlet orifice plate. Differences in expansion factor and discharge coefficient given by these standards give a variation of about +/- 75% mass flow except for a few cases. A comparison of the calculations with an inlet static pressure mass flow correlation and a fan exit mass flow integration using test data from a 2017 turbofan rotor test in W-8 show good agreement between the inlet static pressure mass flow correlation, ISO 5167, and ASME Fluid Meters. While W-8's atmospheric inlet orifice plate violates the pipe diameter limit defined by each of the standards, the ISO 5167 is chosen to be the primary orifice mass flow calculation to use in the W-8 facility.

Aerodynamics↗

Upgrades to the Single Stage Axial Compressor and Fan Facility For Low Pressure Ratio and Boundary Layer Ingesting Fan Research

Next generation aircraft engine efficiency goals will be met through high bypass ratio engines. To achieve these goals, a combination of small core and low pressure ratio fan technologies will be necessary. Additionally, advanced propulsion air-frame integration concepts, such as boundary layer propulsion, and distributed electrically driven fans with short inlets or wing integration strategies, are beginning to be investigated for their potential fuel burn savings. In order to realize the potential fuel savings from these technologies, it is necessary to have testing capabilities for the components. The NASA Glenn Research Center (GRC) Single StageAxial Fan and Compressor Facility (also called the GRC W-8Facility) has recently undergone several significant upgrades in order to effectively test low pressure ratio fans and various inlet distortions. This paper will outline various challenges to testing low pressure ratio fans and the methods implemented to ensure that the W-8 facility is capable of performing these tests and acquiring high quality data. The upgrades include significant pip-ing upgrades to reduce pressure loss and turbulence, capability for inlet total pressure and swirl distortion, increased test section length including a longer shaft, a two component balance, an up-graded rotating data system, and a new temperature characterization to reduce uncertainties in thermocouple measurements

W-8 Facility↗

Upgrades to the Single Stage Axial Compressor and Fan Facility For Low Pressure Ratio and Boundary Layer Ingesting Fan Research

Next generation aircraft engine efficiency goals will be met through high bypass ratio engines. To achieve these goals, a combination of small core and low pressure ratio fan technologies will be necessary. Additionally, advanced propulsion airframe integration concepts, such as boundary layer propulsion, and distributed electrically driven fans with short inlets or wing integration strategies, are beginning to be investigated for their potential fuel burn savings. In order to realize the potential fuel savings from these technologies, it is necessary to have testing capabilities for the components. The NASA Glenn Research Center (GRC) Single Stage Axial Fan and Compressor Facility (also called the GRC W-8 Facility) has recently undergone several significant upgrades in order to effectively test low pressure ratio fans and various inlet distortions. This paper will outline various challenges to testing low pressure ratio fans and the methods implemented to ensure that the W-8 facility is capable of performing these tests and acquiring high quality data. The upgrades include significant piping upgrades to reduce pressure loss and turbulence, capability for inlet total pressure and swirl distortion, increased test section length including a longer shaft, a two component balance, an upgraded rotating data system, and a new temperature characterization to reduce uncertainties in thermocouple measurements.

W-8 facitlity↗

Modeling the Integrated Thermal Amine Scrubber and Air Cooled-Temperature Swing Adsorbent Compressor

As part of a larger CO2 removal architecture study, a model was developed in Aspen Custom Modeler of the Thermal Amine Scrubber (TAS), an ISS flight experiment intended to scrub CO2 from the cabin air. In order to minimize mass losses, it was determined the TAS should work in conjunction with the Air Cooled-Temperature Swing Adsorption Compressor (AC-TSAC) to reduce the CO2 for O2 production. First the TAS removes CO2 from the cabin atmosphere, then the AC-TSAC compresses the CO2 and feeds it in a steady steam to a Sabatier or Bosch process. This document details an effort to add a model of the AC-TSAC to the existing TAS model to determine if the two hardware systems will have deleterious effects on each other’s performance. It was found the AC-TSAC provided sufficient vacuum for the TAS’s desorption to occur, but not the same level of vacuum as space vacuum. This lower quality vacuum led to a reduction in the total cyclical uptake capacity of the TAS and thus a lower CO2 removal under the same conditions. The TAS did not remove enough CO2 to fill the AC-TSAC bed to capacity during the production phase which caused the AC-TSAC to run out of CO2 during production. This renders the addition of the AC-TSAC pointless. It is believed these effects can be overcome with a redesign of one or both systems.

TAS↗

Converter Compressor Building, SWMU 089 Monitoring Well 21 Area Implementation Work Plan Kennedy Space Center, Florida

This Implementation Work Plan (IWP) was prepared by Tetra Tech, Inc., for the National Aeronautics and Space Administration (NASA) under Indefinite Delivery Indefinite Quantity (IDIQ) Contract 80KSC019D0011/80KSC019F0070, for the implementation of a bioremediation Interim Measure (IM) at the Converter Compressor Building (CCB) site located at Kennedy Space Center (KSC), Florida. The location of CCB within KSC is shown on Figure A-1. CCB has been designated as Solid Waste Management Unit (SWMU) 089 under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action Program. The overall Corrective Action Objective (CAO) for CCB is to reduce concentrations of trichloroethene (TCE), cis-1,2-dichloroethene (cDCE), trans-1,2-dichloroethene (tDCE), and vinyl chloride (VC) to less than State of Florida Groundwater Cleanup Target Levels (GCTLs). The objective for the IM associated with this IM is to reduce groundwater concentrations for the contaminants of concern (COCs) to less than their Natural Default Attenuation Concentrations (NADCs) within the Monitoring Well 21 Area (herein referred to as MW21 Area) via bioremediation injections to support transition to long term monitoring (LTM). This IWP describes the activities that will be performed for the treatment of the MW21 Area. The Revision 1 CCB MW21 Area Interim Measure Work Plan (IMWP; NASA, 2024), which was approved by the Florida Department of Environmental Protection (FDEP) on December 26, 2024, was used as the design basis for this IWP.

Mark Jonnet↗