Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Chamber For Testing Polymers In Oxygen Plasma

Apparatus holds polymer specimen at constant temperature while exposing it to oxygen plasma. Copper tube (part of cooling coil) extends into plasma chamber, supporting copper block and thermoelectric module on which specimen mounted. Copper block made small - 4.4 by 3.8 by 1.6 cm - having little effect on plasma. Used to evaluate resistances of polymer materials to plasma environments, and for analysis of gases produced by attack of plasma on polymer specimen.

Whitaker, Ann F.↗

Piezoelectric Pushers Suppress Vibrations

Vibration-suppressing control systems including piezoelectric actuators undergoing development. Small, lightweight, and rugged. Requires simpler electronic control subsystems and does not require large electromagnet coils. Continues to provide support and some passive damping even when electronic control subsystems or power supplies fail. Intended primarily to enhance safety and prevent damage in rotating machinery by sensing and counteracting vibrations. Useful in suppressing unpredictable vibrations caused by changes in loads, losses of rotating components and consequent imbalances in rotors, and ingestion of foreign objects into turbines.

Kascak, Albert F.↗

A fiber-optic current sensor for aerospace applications

A robust, accurate, broad-band, alternating current sensor using fiber optics is being developed for space applications at power frequencies as high as 20 kHz. It can also be used in low and high voltage 60 Hz terrestrial power systems and in 400 Hz aircraft systems. It is intrinsically electromagnetic interference (EMI) immune and has the added benefit of excellent isolation. The sensor uses the Faraday effect in optical fiber and standard polarimetric measurements to sense electrical current. The primary component of the sensor is a specially treated coil of single-mode optical fiber, through which the current carrying conductor passes. Improved precision is accomplished by temperature compensation by means of signals from a novel fiber-optic temperature sensor embedded in the sensing head. The technology contained in the sensor is examined and the results of precision tests conducted at various temperatures within the wide operating range are given. The results of early EMI tests are also given.

Patterson, Richard L.↗

A YBCO RF-SQUID magnetometer and its applications

An applicable RF-superconducting quantum interference detector (SQUID) magnetometer was made using a bulk sintered yttrium barium copper oxide (YBCO). The temperature range of the magnetometer is 77 to 300 K and the field range 0 to 0.1T. At 77 K, the equivalent flux noise of the SQUID is 5 x 10 to minus 4 power theta sub o/square root of Hz at the frequency range of 20 to 200 Hz. The experiments show that the SQUID noise at low-frequency end is mainly from 1/f noise. A coil test shows that the magnetic moment sensitivity delta m is 10 to the minus 6th power emu. The RF-SQUID is shielded in a YBCO cylinder with a shielding ability B sub in/B sub ex of about 10 to the minus 6th power when external dc magnetic field is about a few Oe. The magnetometer is successfully used in characterizing superconducting thin films.

Luwei, Zhou↗

Ionospheric signatures of cusp latitude Pc 3 pulsations

Search coil magnetometer, riometer, photometer, and ELF-VLF receiver data obtained at South Pole Station and McMurdo, Antarctica during selected days in March and April 1986 are compared. Narrow-band magnetic pulsations in the Pc 3 period range are observed simultaneously at both stations in the dayside sector during times of low IMF cone angle, but are considerably stronger at South Pole, which is located at a latitude near the nominal foot point of the dayside cusp/cleft region. Pulsations in auroral light at 427.8 nm wavelength are often observed with magnetic pulsations at South Pole, but such optical pulsations are not observed at McMurdo. The observations suggest that precipitating magnetosheathlike electrons at nominal dayside cleft latitudes are at times modulated with frequencies similar to those of upstream waves. These particles may play an important role, via modification of ionospheric currents and conductivities, in the transmission of upstream wave signals into the magnetosphere and in the generation of dayside high-latitude Pc 3 pulsations.

Engebretson, M. J.↗

Comparative thermal analysis of the Space Station Freedom photovoltaic deployable boom structure using TRASYS, NEVADA, and SINDA programs

The proposed Space Station Photovoltaic Deployable Boom was analyzed for operating temperatures. The boom glass/epoxy structure design needs protective shielding from environmental degradation. The protective shielding optical properties (solar absorptivity and emissivity) dictate the operating temperatures of the boom components. The Space Station Boom protective shielding must also withstand the effects of the extendible/retractable coiling acting within the mast canister. A thermal analysis method was developed for the Space Station Deployable Boom to predict transient temperatures for a variety of surface properties. The modeling procedures used to evaluate temperatures within the boom structure incorporated the TRASYS, NEVADA, and SINDA thermal analysis programs. Use of these programs led to a comparison between TRASYS and NEVADA analysis methods. Comparing TRASYS and NEVADA results exposed differences in the environmental solar flux predictions.

Baumeister, Joseph F.↗

Flow measurements in a model of the mildly curved femoral artery of man

The effects of curvature on the flow rate near the wall in the vicinity of the mildly curved femoral artery of man, and on the pressure distributions along the curved segment, were investigated using glass and tygon flow models constructed to conform to the shape of the femoral angiogram of a human subject. The test fluid was 33 percent aqueous sucrose. Steady flow observations, made using a dye flow visualization system, revealed a flow pattern like that observed in coiled pipes. A double helical type flow was found to develop, with converging streamlines in the wall vicinity from the upper and lower plane of curvature merging asymptotically along the inner curvature in a stable manner. Pressure measurements for steady flow revealed progressively larger pressure drops with distance along the entrance region of the curved segment, relative to that for a straight lumen.

Back, L. H.↗

High temperature skin friction measurement

Skin friction measurement in the NASA Langley hypersonic propulsion facility is described. The sensor configuration utilized an existing balance, modified to provide thermal isolation and an increased standoff distance. For test run times of about 20 sec and ambient-air cooling of the test section and balance, the modified balance performed satisfactorily, even when it was subjected to acoustic and structural vibration. The balance is an inertially balanced closed-loop servo system where the current to a moving-coil motor needed to restore or null the output from the position sensor is a measure of the force or skin friction tending to displace the moving element. The accuracy of the sensor is directly affected by the position sensor in the feedback loop, in this case a linear-variable differential transformer which has proven to be influenced by temperature gradients.

Tcheng, Ping↗

Precision Segmented Reflector figure control system architecture

A control system architecture for an actively controlled segmented reflector is described along with a design realization for achieving precision alignment of reflector panels. Performance requirements are derived in part from the Large Deployable Reflector, which is a representative mission, and error allocations are made which consider mirror panel surface errors, position measurement and figure estimation, and position control of both quasi-static and dynamic disturbances. The design uses multiple wavelength interferometric edge sensors and voice coil actuators in conjunction with a hybrid control strategy to correct panel position errors. A unit cell shown to be central to the concept is analyzed. The cell integrates the sensing, actuation, and mechanical functions of a control module together with a reflector panel to form a unitized assembly.

Mettler, E.↗

Diagnostics and performance of a 1/4-scale MPD thruster

The primary purpose of this study is to evaluate the performance and scaling characteristics of a 1/4-scale magnetoplasmadynamic (MPD) thruster operating with and without applied magnetic nozzle fields. The experiment was carried out with separate pulse forming networks for the thruster and the applied field solenoidal coil. A strong correlation of impact pressure signal with thruster current was noted. Also striking was the larger impact signal when the magnetic nozzle field was applied. Measurements of N(e) and T(e) from Langmuir probes have been made. Compatible interpretation of pressure with N(e), T(e), allow local velocity to be mapped, thus enhancing understanding of the acceleration process.

York, T. M.↗

Nonazeotropic Heat Pump

Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

Ealker, David H.↗

Detecting Filler Spaces Under Tiles

Eddy-current probe nondestructively and indirectly indicates whether screed present under ceramic tile on aluminum substrate. Transducer coil excites eddy currents in aluminum substrate material. Response appears on oscilloscope or meter. Changes in response indicate spatially abrupt changes in substrate. Intended for use on insulating tiles on Space Shuttle, potential terrestrial applications in nondestructive testing.

Mende, Paul↗

Magnetic-Bearing Test Fixture

Microcomputer-controlled magnetic-bearing test fixture used to develop approaches to design of controls for magnetic bearing actuators designed and constructed. Includes load cells connected to bar, in turn, connected through screw positioners to geared drive motors. Position of equivalent suspended element sensed by position sensors and controlled by drive motors. Provides control of gap in magnetic bearing and of current in electromagnet coil. Measurements made include magnetic-bearing gaps, magnetic flux in bearing gaps, and bearing forces. Approaches to linearization and control developed by use of fixture applicable to wide range of small-gap suspension systems.

Groom, Nelson J.↗

A combined Eulerian-Lagrangian two-phase analysis of the SSME HPOTP nozzle plug trajectories

As a result of high cycle fatigue, hydrogen embrittlement, and extended engine use, it was observed in testing that the trailing edge on the first stage nozzle plug in the High Pressure Oxygen Turbopump (HPOTP) could detach. The objective was to predict the trajectories followed by particles exiting the turbine. Experiments had shown that the heat exchanger soils, which lie downstream of the turbine, would be ruptured by particles traveling in the order of 360 ft/sec. An axisymmetric solution of the flow was obtained from the work of Lin et. al., who used INS3D to obtain the solution. The particle trajectories were obtained using the method of de Jong et. al., which employs Lagrangian tracking of the particle through the Eulerian flow field. The collision parameters were obtained from experiments conducted by Rocketdyne using problem specific alloys, speeds, and projectile geometries. A complete 3-D analysis using the most likely collision parameters shows maximum particle velocities of 200 ft/sec. in the heat exchanger region. Subsequent to this analysis, an engine level test was conducted in which seven particles passed through the turbine but no damage was observed on the heat exchanger coils.

Garcia, Robert↗

Superconducting six-axis accelerometer

A new superconducting accelerometer, capable of measuring both linear and angular accelerations, is under development at the University of Maryland. A single superconducting proof mass is magnetically levitated against gravity or any other proof force. Its relative positions and orientations with respect to the platform are monitored by six superconducting inductance bridges sharing a single amplifier, called the Superconducting Quantum Interference Device (SQUID). The six degrees of freedom, the three linear acceleration components and the three angular acceleration components, of the platform are measured simultaneously. In order to improve the linearity and the dynamic range of the instrument, the demodulated outputs of the SQUID are fed back to appropriate levitation coils so that the proof mass remains at the null position for all six inductance bridges. The expected intrinsic noise of the instrument is 4 x 10(exp -12)m s(exp -2) Hz(exp -1/2) for linear acceleration and 3 x 10(exp -11) rad s(exp -2) Hz(exp -1/2) for angular acceleration in 1-g environment. In 0-g, the linear acceleration sensitivity of the superconducting accelerometer could be improved by two orders of magnitude. The design and the operating principle of a laboratory prototype of the new instrument is discussed.

Paik, H. J.↗

Method of fabricating composite structures

A method of fabricating structures formed from composite materials by positioning the structure about a high coefficient of thermal expansion material, wrapping a graphite fiber overwrap about the structure, and thereafter heating the assembly to expand the high coefficient of thermal expansion material to forcibly compress the composite structure against the restraint provided by the graphite overwrap. The high coefficient of thermal expansion material is disposed about a mandrel with a release system therebetween, and with a release system between the material having the high coefficient of thermal expansion and the composite material, and between the graphite fibers and the composite structure. The heating may occur by inducing heat into the assembly by a magnetic field created by coils disposed about the assembly through which alternating current flows. The method permits structures to be formed without the use of an autoclave.

Sigur, W. A.↗

Magnetic bearings with zero bias

A magnetic bearing operating without a bias field has supported a shaft rotating at speeds up to 12,000 rpm with the usual four power supplies and with only two. A magnetic bearing is commonly operated with a bias current equal to half of the maximum current allowable in its coils. This linearizes the relation between net force and control current and improves the force slewing rate and hence the band width. The steady bias current dissipates power, even when no force is required from the bearing. The power wasted is equal to two-thirds of the power at maximum force output. Examined here is the zero bias idea. The advantages and disadvantages are noted.

Brown, Gerald V.↗

Magnetic suspension and balance system advanced study, 1989 design

The objectives are to experimentally confirm several advanced design concepts on the Magnetic Suspension and Balance Systems (MSBS). The advanced design concepts were identified as potential improvements by Madison Magnetics, Inc. (MMI) during 1984 and 1985 studies of an MSBS utilizing 14 external superconductive coils and a superconductive solenoid in an airplane test model suspended in a wind tunnel. This study confirmed several advanced design concepts on magnetic suspension and balance systems. The 1989 MSBS redesign is based on the results of these experiments. Savings of up to 30 percent in supporting magnet ampere meters and 50 percent in energy stored over the 1985 design were achieved.

Boom, Roger W.↗