Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CURRENT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column

This passive laser heterodyne radiometer (LHR) instrument simultaneously measures multiple trace gases in the atmospheric column including carbon dioxide (CO2) and methane (CH4), and resolves their concentrations at different altitudes. This instrument has been designed to operate in tandem with the passive aerosol sensor currently used in AERONET (an established network of more than 450 ground aerosol monitoring instruments worldwide). Because aerosols induce a radiative effect that influences terrestrial carbon exchange, simultaneous detection of aerosols with these key carbon cycle gases offers a uniquely comprehensive measurement approach. Laser heterodyne radiometry is a technique for detecting weak signals that was adapted from radio receiver technology. In a radio receiver, a weak input signal from a radio antenna is mixed with a stronger local oscillator signal. The mixed signal (beat note, or intermediate frequency) has a frequency equal to the difference between the input signal and the local oscillator. The intermediate frequency is amplified and sent to a detector that extracts the audio from the signal. In the LHR instrument described here, sunlight that has undergone absorption by the trace gas is mixed with laser light at a frequency matched to a trace gas absorption feature in the infrared (IR). Mixing results in a beat signal in the RF (radio frequency) region that can be related to the atmospheric concentration. For a one-second integration, the estimated column sensitivities are 0.1 ppmv for CO2, and <1 ppbv for CH4. In addition to producing a standalone ground measurement product, this instrument could be used to calibrate/validate four Earth observing missions: ASCENDS (Active Sensing of CO2 Emissions over Nights, Days, and Seasons), OCO-2 (Orbiting Carbon Observatory), OCO-3, and GOSAT (Greenhouse gases Observational SATellite). The only network that currently measures CO2 and CH4 in the atmospheric column is TCCON (Total Carbon Column Observing Network), and only two of its 16 operational sites are in the United States. TCCON data is used for validation of GOSAT data, and will be used for OCO-2 validation. While these Fourier-transform spectrometers (FTS) can measure the largest range of trace gases, the network is severely limited due to the high cost and extreme size of these instruments (these occupy small buildings and require personnel for operation). The LHR/AERONET instrument offers a significantly smaller (carry-on luggage size) autonomous instrument that can be incorporated into AERONET s much larger (450 instruments) global network.

Steel, Emily↗

Magnetic control of magnetohydrodynamic instabilities in tokamaks

Externally applied, non-axisymmetric magnetic fields form the basis of several relatively simple and direct methods to control magnetohydrodynamic (MHD) instabilities in a tokamak, and most present and planned tokamaks now include a set of non-axisymmetric control coils for application of fields with low toroidal mode numbers. Non-axisymmetric applied fields are routinely used to compensate small asymmetries (δB/B∼10{sup −3} to 10{sup −4}) of the nominally axisymmetric field, which otherwise can lead to instabilities through braking of plasma rotation and through direct stimulus of tearing modes or kink modes. This compensation may be feedback-controlled, based on the magnetic response of the plasma to the external fields. Non-axisymmetric fields are used for direct magnetic stabilization of the resistive wall mode—a kink instability with a growth rate slow enough that feedback control is practical. Saturated magnetic islands are also manipulated directly with non-axisymmetric fields, in order to unlock them from the wall and spin them to aid stabilization, or position them for suppression by localized current drive. Several recent scientific advances form the foundation of these developments in the control of instabilities. Most fundamental is the understanding that stable kink modes play a crucial role in the coupling of non-axisymmetric fields to the plasma, determining which field configurations couple most strongly, how the coupling depends on plasma conditions, and whether external asymmetries are amplified by the plasma. A major advance for the physics of high-beta plasmas (β = plasma pressure/magnetic field pressure) has been the understanding that drift-kinetic resonances can stabilize the resistive wall mode at pressures well above the ideal-MHD stability limit, but also that such discharges can be very sensitive to external asymmetries. The common physics of stable kink modes has brought significant unification to the topics of static error fields at low beta and resistive wall modes at high beta. These and other scientific advances, and their application to control of MHD instabilities, will be reviewed with emphasis on the most recent results and their applicability to ITER.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonresonant Diffusion in Alpha Channeling

The gradient of fusion-born alpha particles that arises in a fusion reactor can be exploited to amplify waves, which cool the alpha particles while diffusively extracting them from the reactor. Furthermore, the corresponding extraction of the resonant alpha particle charge has been suggested as a mechanism to drive rotation. By deriving a coupled linear-quasilinear theory of alpha channeling, we show that, for a time-growing wave with a purely poloidal wave vector, a current in the nonresonant ions cancels the resonant alpha particle current, preventing the rotation drive but fueling the fusion reaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intermittent behavior of galactic dynamo activities

Recent observations by Beck and Golla of far-infrared and radio continuum emission from nearby spiral galaxies suggest that the galactic magnetic field strength is connected to the current star formation rate. The role of star formation on the generation of large-scale galactic magnetic field is studied in this paper. Using a simple galactic model, it is shown how the galactic dynamo depends strongly on the turbulent velocity of the interstellar medium. When the star formation efficiency is high, the ISM is churned which in turn amplifies the galactic magnetic field. Between active star formation epochs, the magnetic field is in dormant state and decays at a negligible rate. If density waves trigger star formation, then they also turn on the otherwise dormant dynamo.

Ko, C. M.↗

The Grism Lens-Amplified Survey from Space (GLASS). XI. Detection of C iv in Multiple Images of the z = 6.11 Lyα Emitter behind RXC J2248.7–4431

The C iii] and C iv rest-frame UV emission lines are powerful probes of the ionization states of galaxies. They have furthermore been suggested as alternatives for spectroscopic redshift confirmation of objects at the epoch of reionization (z>6), where the most frequently used redshift indicator, Lyα, is attenuated by the high fraction of neutral hydrogen in the intergalactic medium. However, currently only very few confirmations of carbon UV lines at these high redshifts exist, making it challenging to quantify these claims. Here, we present the detection of C iv λλ1548, 1551 Å in Hubble Space Telescope slitless grism spectroscopy obtained by GLASS of a Lyα emitter at z = 6.11 multiply imaged by the massive foreground galaxy cluster RXC J2248.7–4431. The C iv emission is detected at the 3σ–5σ level in two images of the source, with marginal detection in two other images. We do not detect significant C iii]λλ1907, 1909 Å emission implying an equivalent width EW{sub CIII]}<20 Å (1σ) and C IV/C III>0.7 (2σ). Combined with limits on the rest-frame UV flux from the He ii λ1640 Å emission line and the O iii]λλ1661, 1666 Å doublet, we put constraints on the metallicity and the ionization state of the galaxy. The estimated line ratios and equivalent widths do not support a scenario where an AGN is responsible for ionizing the carbon atoms. SED fits, including nebular emission lines, imply a source with a mass of log(M/M {sub ⊙}) ∼ 9, SFR of around 10 M {sub ⊙} yr{sup −1}, and a young stellar population <50 Myr old. The source shows a stronger ionizing radiation field than objects with detected C iv emission at z<2 and adds to the growing sample of low-mass (log(M/M {sub ⊙}) ≲ 9) galaxies at the epoch of reionization with strong radiation fields from star formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Cardinal: Seismic and Geoacoustic Array Processing

Data collected via seismic and infrasound array deployments are leveraged in the geosciences to detect and characterize a myriad of natural and anthropogenic sources. These deployments consist of numerous sensors placed in a predetermined configuration to amplify signal strength and improve the efficacy of array processing techniques used to measure signal directionality and waveform coherence. High‐fidelity feature extraction is often predicated on interstation distance as well as the frequency content and wavelength of an incident signal. Numerous array processing softwares analyze data in sequential frequency bands to obtain a more detailed characterization of a signal. However, current algorithms are limited in their ability to determine optimal array configuration for each band. We introduce an open‐source Python code, called Cardinal, to process seismic and infrasound array data in discretized time–frequency space with the option of applying an adaptive array design to determine optimal subarray configuration for each frequency band. To reduce computational time, the array processing step can be run in parallel using multithreading. Furthermore, the software has the capability to aggregate array processing results from different time–frequency pixels to produce separate sets of detections, or families, with added utility via the application of an adaptive semblance threshold, which aids in isolating signals‐of‐interest from coherent background noise. Upon appropriate configuration, Cardinal exhibits the potential to combine distinct seismic and infrasound phases into separate families.

Adaptive Array↗

Beam-waveguide antenna servo design issues for tracking low earth-orbiting satellites

Upcoming NASA missions will require tracking of low-orbit satellites. As a consequence, NASA antennas will be required to track satellites at higher rates than for the current deep space missions. This article investigates servo design issues for the 34-m beam-waveguide antennas that track low-orbit satellites. This includes upgrading the servo with a feedforward loop, using a monopulse controller design, and reducing tracking errors through either proper choice of elevation pinion location, application of a notch filter, or adjustment of the elevation drive amplifier gain. Finally, improvement of the signal-to-noise ratio through averaging of the over-sampled monopulse signal is described.

Gawronski, W. K.↗

Electro-Optic Lightning Detector

Electric field measurements are fundamental to the study of thunderstorm electrification, thundercloud charge structure, and the determination of the locations and magnitudes of charges deposited by lightning. Continuous field observations can also be used to warn of impending electrical hazards. For example, the USAF Eastern Range (ER) and NASA Kennedy Space Center (KSC) in Florida currently operate a ground-based network of electric field mill sensors to warn against lightning hazards to space vehicle operations/launches. The sensors provide continuous recordings of the ambient field. Others investigators have employed flat-plate electric field antennas to detect changes In the ambient field due to lightning. In each approach, electronic circuitry is used to directly detect and amplify the effects of the ambient field on an exposed metal conductor (antenna plate); in the case of continuous field recordings, the antenna plate is alternately shielded and unshielded by a grounded conductor. In this work effort, an alternate optical method for detecting lightning-caused electric field changes is Introduced. The primary component in the detector is an anisotropic electro-optic crystal of potassium di-hydrogen phosphate (chemically written as KH2PO4 (KDP)). When a voltage Is placed across the electro-optic crystal, the refractive Indices of the crystal change. This change alters the polarization state of a laser light beam that is passed down the crystal optic axis. With suitable application of vertical and horizontal polarizers, a light transmission measurement is related to the applied crystal voltage (which in turn Is related to the lightning caused electric field change). During the past two years, all critical optical components were procured, assembled, and aligned. An optical housing, calibration set-up, and data acquisition system was integrated for breadboard testing. The sensor was deployed at NASA Marshall Space Flight Center (MSFC) in the summer of 1998 to collect storm data. Because solid-state technology is used, future designs of the sensor will be significantly scaled down In physical dimension and weight compared to the present optical breadboard prototype. The use of fiber optics would also provide significant practical improvements.

Koshak, William J.↗

Beam-Waveguide Antenna Servo Design Issues for Tracking Low-Earth-Orbiting Satellites

The upcoming NASA missions will require tracking of low-orbit satellites. As a consequence, NASA antennas will be required to track satellites at higher rates than for the current deep space missions. This paper investigates servo design issues for the 34-m beam-waveguide (BWG) antennas that track low-orbit satellites. This includes the upgrade of the servo with the feedforward loop, monopulse controller design, and tracking error reduction through proper choice of elevation pinion location, through application of a notch filter, and through the elevation drive amplifier gain adjustment. Finally, improvement of the signal-to-noise ratio through averaging of the oversampled monopulse signal is presented.

Mellstrom, J. A.↗

Comparison of Two Digital Stethoscopes with the Traditional Stethoscope Used on International Space Station

A traditional stethoscope is currently flown on the International Space Station (ISS). The background noise on the ISS is much higher than a normal exam room, and the literature shows that traditional stethoscopes are unable to function effectively in high noise environments. Digital stethoscopes provide amplification which improves the audibility in a quiet environment. This study is designed to determine if digital stethoscopes offer any advantage over traditional stethoscopes in being able to identify normal and abnormal sounds in the ISS noise environment. Methods: An ISS noise simulation facility was created to reproduce ISS noise profiles by modifying pink noise with a software-based graphic equalizer. The files were played in a continuous loop on a computer, amplified through a high-end stereo system and adjusted using a sound level meter. Nine caregiver analogues were given the same auscultation lesson received by astronauts. They began testing by becoming familiar with normal and abnormal sounds on a Student Auscultation Manikin . They then used two digital stethoscopes and a traditional stethoscope identical to the one flown on the ISS to auscultate the manikin sounds in the noise facility. They identified the sounds on a questionnaire and picked which of the three stethoscopes they preferred. Results: Evaluators displayed equivalent accuracy in sound identification when using either the 3M model 4000 digital stethoscope or traditional stethoscope. However, the 3M was preferred 2 to 1 by the evaluators, primarily because of additional amplification of the sounds. Discussion: Although our results show that the current ISS stethoscope and the "best-of-breed" digital stethoscope provide essentially the same auscultation utility, the latter has the advantage of recording and transmitting sounds to a remote physician. Since the astronaut caregivers are non-physiCians, this capability may be worth the additional expense and effort needed to certify the digital stethoscope for flight.

Rasbury, Jack↗

Measurements and Studies of Secondary Electron Emission of Diamond Amplified Photocathode

Over many years, electron accelerators have served in a large variety of applications. Besides the contribution of electron colliders such as LEP in the precise measurements of important values in the Standard Model, scientists and engineers have made possible high brightness, constant power, and short wavelength light sources to be possible. Synchrotron Light Sources and Free Electron Lasers (FEL) provide the largest work platforms with high X-ray energy and brightness for biology, chemistry, material science, medical science, and much more. Many applications require continuous current, high intensity electron beams with narrow spatial and temporal distributions.

43 PARTICLE ACCELERATORS↗

Generation of terahertz radiation in the interaction of a femtosecond pulse with a metal film

The action of an s-polarised femtosecond laser pulse is found to result in nonlinear currents in a metal film, which arise due to the nonuniform heating of the conduction electrons and under the influence of the drag force. The Fourier transforms of a low-frequency magnetic field generated by nonlinear currents are calculated. It is shown that when the film thickness is less than the scale of the low-frequency field nonuniformity, the amplitude of the terahertz signal increases in inverse proportion to the film thickness. If the thickness of the film is less than the depth of the skin layer at the laser frequency, the low-frequency signal is amplified inversely proportional to the square of the film thickness. (terahertz radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-AB-BRA-07: Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams

Purpose: We developed a pre-clinical prototype system for range verification of proton pencil-beam scanning fields. The system was evaluated using phantom treatment plans delivered with a clinical dose rate. Methods: The absolute range of proton pencil-beams was verified through an optimization procedure, which matches energy- and time-resolved prompt gamma-ray measurements with models, based on cross sections for discrete prompt gamma-ray line excitations. Phantom experiments were performed with a pre-clinical prototype detector, using treatment plans delivered with a clinical pencil-beam scanning system. The detector consisted of an actively shielded lanthanum(III) bromide scintillator. Tungsten was used to collimate the gamma-rays. To support high event rates, the detector readout featured custom amplifiers and an active voltage divider for the photomultiplier. The detector signals were acquired by fast analog-to-digital converters and processed using digital algorithms. The data acquisition was also synchronized with the pencil-beam scanning and dosimetry systems. Results: We successfully acquired prompt gamma-ray spectra during the delivery of proton pencil-beams with a clinical beam current of 2 nA at the exit of the treatment head. The number of events in the primary detector ranged from 1 x 10{sup 6} to 2 x 10{sup 6} per second. In phantom experiments, non-uniform range errors were introduced by placing strips of plastic in the beam path. The magnitudes and positions of these range errors were correctly detected in two-dimensional range maps that were generated from the measurements. With our small scale prototype, a 1.0 mm standard deviation on the absolute range required about 5 x 10{sup 8} protons per delivered pencil-beam. Conclusions: Prompt gamma-ray spectroscopy to verify the absolute range of proton beams was demonstrated under clinical pencil-beam delivery conditions. A 1 mm to 2 mm range verification accuracy for a field delivering 1 Gy, appears feasible with a full scale system. This work was supported by the Federal Share of program income earned on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Exchange interactions of paramagnetic spins on α-Al 2 O 3

Superconducting qubits (SQs) represent a promising route to achieving a scalable quantum computer. However, the coupling between SQs and (as yet largely unidentified) parasitic noise sources has so far limited the functionality of current SQs by reducing the coherence time of the quantum states below a practical threshold for measurement and manipulation. These noise sources also more generally limit the performance of a variety of devices based on superconducting circuits, including high energy-resolution cryogenic radiation detectors, sensitive magnetic detectors (superconducting quantum interference devices, or SQUIDs), nanomechanical motion sensors and quantum-limited parametric amplifiers. In this paper, we study the origins of spin interactions on a substrate using OH on sapphire as a model system. We show how the substrate can mediate spin-spin interactions generally favoring FM interactions, but that strain can modify the interaction. Surface and sub-surface defects between the spin defects may also enhance the exchange interactions.

36 MATERIALS SCIENCE↗

Electro-Thermo-Mechanical (ETM) Study on Submarine Dynamic Power Cables (SDPC) for Offshore Wind Transmission

Understanding the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project conducted a systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15kV power cable with three cores of copper conductor, ethylene propylene rubber (EPR) insulation, and continuously corrugated welded aluminum armor (CCWA). An ETM testing system was developed by integrating a high voltage (HV) amplifier, two ceramic heaters, and a rod-plate transverse compression setup into a mechanical testing machine. Increasing temperature from room temperature (RT, 22 degree C) to 90 degree C resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. Under creep mechanical loading, the dielectric breakdown time was decreased by 70% for a given mechanical load when the specimen temperature increased from RT to 90oC. The failure strain in both monotonic and creep mechanical loading modes was related to the maximum mechanical load applied. Although the dielectric breakdown occurred in the ETM test, the post-test measurement revealed an impressive recovery of electric resistance. The failure analysis on cross section of tested specimens indicated a sizable gap across insulation layer near the area between copper conductor and loading rod, which apparently resulted from online dielectric failure and offline elastic recovery of components including conductor and insulation layer.

17 WIND ENERGY↗

The merging galaxy cluster A520—a broken-up cool core, a dark subcluster, and an X-ray channel

We present results from a deep Chandra X-ray observation of a merging galaxy cluster A520. A high-resolution gas temperature map reveals a long trail of dense, cool clumps—apparently the fragments of a cool core that has been stripped from the infalling subcluster by ram pressure. The clumps should still be connected by the stretched magnetic field lines. The observed temperature variations imply that thermal conductivity is suppressed by a factor >100 across the presumed direction of the magnetic field (as found in other clusters), and is also suppressed along the field lines by a factor of several. Two massive clumps in the periphery of A520, visible in the weak-lensing mass map and the X-ray image, have apparently been completely stripped of gas during the merger, but then re-accreted the surrounding high-entropy gas upon exit from the cluster. The mass clump that hosted the stripped cool core is also reaccreting hotter gas. An X-ray hydrostatic mass estimate for the clump that has the simplest geometry agrees with the lensing mass. Its current gas mass to total mass ratio is very low, 1.5%–3%, which makes it a “dark subcluster.” We also found a curious low X-ray brightness channel (likely a low-density sheet in projection) going across the cluster along the direction of an apparent secondary merger. The channel may be caused by plasma depletion in a region of an amplified magnetic field (with plasma β∼10--20). The shock in A520 will be studied in a separate paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Multimodality in the Search for New Physics in Pulsar Timing Data and the Case of Kination-amplified Gravitational-wave Background from Inflation

We investigate the kination-amplified inflationary gravitational-wave background (GWB) interpretation of the signal recently reported by various pulsar timing array (PTA) experiments. Kination is a post-inflationary phase in the expansion history dominated by the kinetic energy of some scalar field, characterized by a stiff equation of state w = 1. Within the inflationary GWB model, we identify two modes that can fit the current data sets (NANOGrav and EPTA) with equal likelihood: the kination-amplification (KA) mode and the ordinary, no-kination-amplification (no-KA) mode. The multimodality of the likelihood motivates a Bayesian analysis with nested sampling. We analyze the free spectra of current PTA data and mock free spectra constructed with higher signal-to-noise ratios using nested sampling. The analysis of the mock spectrum designed to be consistent with the best fit to the NANOGrav 15 yr (NG15) data successfully reveals the expected bimodal posterior for the first time while excluding the reheating mode that appears in the fit to the current NG15 data, making a case for our correct and comprehensive treatment of potential multimodal posteriors arising from future PTA data sets. The resultant Bayes factor is $\mathcal{B}$ $\equiv$ Z no–KA /Z KA = 2.9 ± 1.9, indicating comparable statistical significance between the two modes. Given the theoretical model-building challenges of producing highly blue-tilted primordial tensor spectra, the KA mode has the advantage of requiring less blue primordial spectra, compared with the no-KA mode. The synergy between future cosmic microwave background polarization, pulsar timing, and laser interferometer measurements of gravitational waves will help resolve the ambiguity implied by the multimodal posterior in PTA-only searches.

Cosmology↗

Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults With Amputations

The first single function myoelectric prosthetic hand was introduced in the 1960's. This hand was controlled by the electric fields generated by muscle contractions in the residual limb of the amputee user. Electrodes and amplifiers, embedded in the prosthetic socket, measured these electric fields across the skin, which increase in amplitude as the individual contracts their muscle. When the myoelectric signal reached a certain threshold amplitude, the control unit activated a motor which opened or closed a hand-like prosthetic terminal device with a pincher grip. Late in the 1990's, little has changed. Most current myoelectric prostheses still operate in this same, single-function way. To better understand the limitations of the current single-function myoelectric hand and the needs of those who use them, The Institute for Rehabilitation and Research (TIRR), sponsored by the National Institutes of Health (NUH), surveyed approximately 2,500 individuals with upper limb loss [1]. When asked to identify specific features of their current myoelectric prostheses that needed improvement, the survey respondents overwhelmingly identified the lack of wrist and finger movement, as well as poor control capability. However, simply building a mechanism with individual finger and wrist motion is not enough. In the 1960's and 1970's, engineers built a number of more dexterous prosthetic hands. Unfortunately, these were rejected during clinical trials due to a difficult and distracting control interface. The goal of this project, "Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults with Amputations," was to lay the foundation for a multi-function, intuitive myoelectric control system which requires no conscious thought to move the hand. We built an extensive myoelectric signal database for six motions from ten amputee volunteers, We also tested a control system based on new artificial intelligence techniques on the data from two of these subjects. This data is available to anyone doing myoelectric control research. Its availability is an important contribution to the prosthetics research community, as many researchers do not have access to amputee subjects. Since we collected myoelectric data from subjects' sound arms as well as their residual arms, this database will also prove useful to virtual reality and robotics researchers who want to explore myoelectric-based interfaces between any user and a machine. Currently, one small company (Intelligenta, Inc.) and one university (University of New Brunswick, Canada) are using this myoelectric database under other funding to develop multifunction control systems for prostheses. A prosthetics manufacturer (Liberty Technology, Inc.) is making plans to incorporate the results of their work into an artificial hand capable of several different movements to provide functionality only dreamed of by current myoelectric users. Methods Six adults and four children, all with unilateral, below-elbow amputations served as subjects. Five of the adults (3 male, 2 female, average age 34 years) had amputations due to traumatic injury, while one adult (female, age 32 years) and the four children (3 male, 1 female, average age 13 years) had congenital (i.e. from birth) limb deficiencies.

Atkins, Diane J.↗