Accuracy of a Crude Approach to Urban Multi-Scale Building Energy Models Compared to 15-min Electricity Use

ASHRAE has recently named a TC4.7 subcommittee on Multi-Scale Energy Modeling and there have been many technical developments focused on urban-scale energy modeling with the goal of creating building energy models for all buildings in a city to facilitate simulation-informed energy optimization for the built environment. These efforts often rely on non-scalable, local sources of information (e.g. county’s tax assessor’s database) to create more accurate models of those buildings. In partnership with the local utility, a year’s worth of real-world 15-minute electrical use data from 178,377 premise buildings has been assessed. This smart meter data is statistically analyzed and compared to corresponding simulation data for 97 different building prototypes in order to better assess simulation accuracy for various utility-defined use cases. To our knowledge, this is the first time real world and simulated building energy use data have been compared at this scale.

Garrison, Eric↗

A Comparative Techno-Economic Analysis of Sustainable Methanol Synthesis Pathways from Biomass and CO2

The call to reduce global CO2 emissions is at the forefront of research and development in the transportation and petrochemical industries. A potential solution which intersects both sectors is the adoption and commercialization of more sustainable technologies for methanol production. Currently, methanol is gaining popularity as a possible fuel additive, and as a polymer precursor via established methanol-to-olefins routes which are increasing in capacity and utilization, putting methanol in the spotlight and global methanol production on the rise. At the same time, experimental and computational studies have surged, illuminating a wide array of novel process designs to introduce sustainable methanol into the market. However, with numerous competing pathways identified across a variety of fossil and non-fossil feedstocks, there is a need to harmonize the analyses of these pathways using a consistent techno-economic approach and compare them to current commercial pathways to better understand the benefits or limitations inherent to each technology. In this work we conduct a consistent comparative analysis of three sustainable methanol synthesis pathways versus a commercial baseline, with biomass, CO2, and natural gas as the carbon sources. The three sustainable pathways of interest are biomass gasification to syngas with subsequent catalytic conversion of syngas to methanol, indirect conversion of CO2 to syngas via electrolysis with subsequent catalytic conversion of syngas to methanol, and direct conversion of CO2 to methanol via electrolysis. To elucidate the challenges and opportunities in the path to commercialization of each sustainable pathway, we investigate five key process metrics: production cost, carbon efficiency, carbon intensity, energy efficiency, and technology readiness level (TRL).

biomass↗

Comparing Thick Target Neutron Yield Calculations for Alphas on F-19 using MCNP6 1.1 Beta with TENDL 2012 Libraries

Because of the heritage of MCNPX, the first production release of MCNP6{sup TM} used physics models, instead of ACE (A Compact Evaluated Nuclear Data File) formatted libraries, for simulating the transport of alpha particles at all energies, as MCNPX could not yet read ACE formatted light ion libraries. For non-Coulombic interactions, the physics models have suggested minimums of ∼ 20-200 MeV. The first production release of MCNP6, MCNP6{sup TM} 1.0, was still capable of transporting alphas to low energies; however, the physics models resulted in poor prediction of inelastic reactions at energies below the suggested minimums. This poorer prediction at low energies resulted in orders of magnitude lower neutron yields for events resulting from light ion interactions at low energies. For example, F-19(α,n)Na-22 from U-234 decay in UF{sub 6} produced poor neutron production results. Modeling these types of interactions correctly is vital for signal analysis for nonproliferation safeguards and nuclear security as well as for correctly characterizing source terms for radiation protection and shielding calculations. The TALYS computer code was developed to simulate nuclear reactions involving neutrons, photons, protons, deuterons, tritons, alphas and He-3 particles, in the 1 keV - 200 MeV energy range. TENDL is a nuclear data library, which provides the output of the TALYS nuclear model code system for direct use in applications (i.e. ACE formatted cross sections). Since 2008, TENDL had publicly provided ACE formatted libraries for alpha transport; however, not until the release of MCNP6{sup TM} 1.1 beta, had MCNP6 publicly possessed the capability to read such libraries. At the Radiation Protection and Shielding Division topical meeting in 2014, initial testing of MCNP6 1.1 beta showed that MCNP6 using TENDL 2012 resulted in poor prediction when compared to the compilation of experiment data provided in R. Heaton et al. Further comparisons for PuBe sources, using the MCNP6 1.1 beta spontaneous decay alpha feature coupled with alpha transport, were also given in the winter American Nuclear Society meeting in 2014, where the results showed large discrepancies with measured data. For F-19(α,n)Na-22 interactions, the R. Heaton et al. paper is a conglomeration of several important references; and the data provided by R. Heaton et al. used a numerical fit of the excitation function provided by Norman et al.. Norman et al. has recently published their (α,n) thick target yield data for PbF{sub 2} in tabular form, backing out the thick target yields of F-19(α,n)Na-22 and computing F{sub 2} and UF{sub 6} thick target neutron yields (as supplements to the PbF{sub 2} data). Here we compared measured thick target yields of E. B. Norman et al. to MCNP6 1.1 beta using TENDL 2012 libraries. Deterministically backing out the thick target yield from measured values involves using the stopping power. MCNP uses either the SPAR code or an interpolation of the Spar code and Bethe-Boch formula for computing stopping powers. As a result one may believe that these separate methods will arrive at separate thick target yields independent of the production cross section. In our MCNP calculations, we simulated the alpha until the alpha completely stopped in the medium. The energy loss in the condensed history algorithm is not continuous but discrete and related to the stopping powers. Because the neutron production yield is energy dependent, the energy loss dictates the emission of secondary neutrons; and therefore the difference in stopping powers used may have some slight effect on the yield difference. For this study, we chose to use the default condensed history algorithm setup, while future studies should address tightening steps in the condensed history algorithm to prove whether or not choice of stopping power actually matters. The fact that all 5 evaluated isotopic compositions resulted in different thick target yield percent differences does warrant this type of investigation. A typical user may not be only interested in integral emission, taking 10 s to 100 s of processor hours to simulate, but rather a timely generation of the spectra. Such an application would require biasing the production of secondaries from alpha sources such that millions of secondaries could be produced, emulating a converged energy dependent spectra. Neutron production biasing from alpha sources does not currently exist; however, developing a biasing algorithm for neutron production from alpha sources should be investigated in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Panel Session 12: Effective Aspects of the 2016 Consent Order between DOE-EM-LA Field Office - NM Environment Department and Identifying Comparable Approaches

This panel focused on the extremely effective 2016 Compliance Order on Consent executed between the US Department of Energy (DOE) Office of Environmental Management - Los Alamos Field Office (EM-LA) and the New Mexico Environment Department (NMED) and highlights practices and concepts toward developing an environmental compliance agreement that is mutually productive to both the NMED and the DOE. To further demonstrate successful practices, the panel also highlighted another very effective compliance agreement with comparable approaches - the 1993 Savannah River Site (SRS) Federal Facility Agreement (FFA) executed between DOE, the South Carolina Department of Health and Environmental Control (SCDHEC), and the Environmental Protection Agency (EPA). EM-LA, NMED, SRS, and SCDHEC representatives provided attendees an opportunity to understand and compare extremely effective approaches to regulatory compliance across the complex.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Baseload Hydrogen Production Using Nuclear and Renewable Energy: A Comparative Analysis

As the global push towards net zero carbon gains momentum, the demand for clean hydrogen is expected to grow rapidly across various sectors, including transportation, industries and electrical grids. To meet this growing hydrogen demand, baseload hydrogen production facilities capable of providing a continuous and reliable supply of hydrogen will be necessary throughout the world. This paper explores the technoeconomic feasibility of establishing baseload electrolytic hydrogen production facilities in the United States, utilizing different clean generation resources. The key criteria include maintaining a consistent supply of clean hydrogen without putting baseload demand stress to already vulnerable power grid. In order to do that, the proposed facilities will host onsite clean power generation and energy storage technologies. The proposed facilities can capitalize on available investment and production incentives and have ability to export excess electricity to the utility at a bulk price. Several scenarios are considered based on the clean energy resources to support the electrolysis process including light water reactors (LWRs) currently evaluating retirement options, wind, solar PVs, and advanced small modular reactors (SMRs). For each scenario, a hypothetical hydrogen production facility is considered in a location in the US where the primary generation resource is at its peak strength. Comparative analysis in this paper reveal that the nuclear power plants are most economically viable for baseload hydrogen production facilities, outperforming renewable-based facilities with significantly lower levelized cost of hydrogen (LCOH). Even under best-case scenarios for resource availability, incentives and export prices, renewable-based facilities face challenges due to daily and seasonal generation variability, resulting in large installation sizes and lower capacity factors. Among renewable-based facilities, complementarity hybrids, providing more stable power supply, demonstrate superior economics compared to facilities based on a single renewable technology. While LWR-powered facility can achieve a negative LCOH with incentives, SMR-powered facilities can provide economic hydrogen supply with LCOH below $1/kg with high temperature electrolysis option. The analysis in this paper underscores the pivotal role of nuclear energy in the future hydrogen economy.

08 - HYDROGEN↗

Adjuvant Hepatic Arterial Infusion Chemotherapy After Resection for Pancreatic Cancer Using Coaxial Catheter-Port System Compared with Conventional System

PurposePrevious reports have shown the effectiveness of adjuvant hepatic arterial infusion chemotherapy (HAIC) in pancreatic cancer. However, percutaneous catheter placement is technically difficult after pancreatic surgery. The purpose of this study was to evaluate the feasibility and outcome of HAIC using a coaxial technique compared with conventional technique for postoperative pancreatic cancer.Materials and Methods93 consecutive patients who received percutaneous catheter-port system placement after pancreatectomy were enrolled. In 58 patients from March 2006 to August 2010 (Group A), a conventional technique with a 5-Fr indwelling catheter was used and in 35 patients from September 2010 to September 2012 (Group B), a coaxial technique with a 2.7-Fr coaxial catheter was used.ResultsThe overall technical success rates were 97.1 % in Group B and 86.2 % in Group A. In cases with arterial tortuousness and stenosis, the success rate was significantly higher in Group B (91.7 vs. 53.8 %; P = 0.046). Fluoroscopic and total procedure times were significantly shorter in Group B: 14.7 versus 26.7 min (P = 0.001) and 64.8 versus 80.7 min (P = 0.0051), respectively. No differences were seen in the complication rate. The 1 year liver metastasis rates were 9.9 % using the conventional system and 9.1 % using the coaxial system (P = 0.678). The overall median survival time was 44 months. There was no difference in the survival period between two systems (P = 0.312).ConclusionsThe coaxial technique is useful for catheter placement after pancreatectomy, achieving a high success rate and reducing fluoroscopic and procedure times, while maintaining the safety and efficacy for adjuvant HAIC in pancreatic cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Study Using 100–300 Versus 300–500 μm Microspheres for Symptomatic Patients Due to Enlarged-BPH Prostates

PurposeThe purpose of the study was to compare safety and efficacy outcomes following prostate artery embolization (PAE) for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH) with 100–300 versus 300–500 μm tris-acryl gelatin microspheres.Materials and MethodsPatients were prospectively treated between August 2011 and June 2013 to receive PAE with 100–300 μm (group A) or 300–500 μm (group B) tris-acryl gelatin microspheres. Patients were followed for a minimum of 12 months and were assessed for changes in International Prostate Symptom Score (IPSS), quality of life (QoL) index, prostate volume determined by magnetic resonance imaging, serum prostate specific antigen (PSA), and maximum urine flow rate (Q{sub max}), as well as any treatment-related adverse events.ResultsFifteen patients were included in each group, and PAE was technically successful in all cases. Both groups experienced significant improvement in mean IPSS, QoL, prostate volume, PSA, and Q{sub max} (p < 0.05 for all). The differences observed between the two groups included a marginally insignificant more adverse events (p = 0.066) and greater mean serum PSA reduction at 3 months of follow-up (p = 0.056) in group A.ConclusionsBoth 100–300 and 300–500 μm microspheres are safe and effective embolic agents for PAE to treat LUTS-related to BPH. Although functional and imaging outcomes did not differ significantly following use of the two embolic sizes, the greater incidence of adverse events with 100–300 μm microspheres suggests that 300–500 μm embolic materials may be more appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis

PurposeProstatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH.Materials and MethodsIRB-approved retrospective study of 40 consecutive patients 49–81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months.ResultsNo significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm{sup 2} vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred.ConclusionsRobotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Analysis of the Formation of γH2AX Foci in Human Mesenchymal Stem Cells Exposed to {sup 3}H-Thymidine, Tritium Oxide, and X-Rays Irradiation

We performed a comparative study of the formation of γН2АХ foci (a marker of DNA doublestrand breaks) in human bone marrow mesenchymal stem cells after 24-h incubation with {sup 3}Н-thimidin and tritium oxide with low specific activities (50-800 MBq/liter). The dependence of the number of γH2AX foci on specific activity of 3H-thymidine was described by a linear equation y=2.21+43.45x (R{sup 2}=0.96), where y is the number of γH2AX foci per nucleus and x is specific activity in 1000 MBq/liter. For tritium oxide, the relationship was described by a linear equation y=2.52+6.70x (R{sup 2}=0.97). Thus, the yield of DNA double-strand breaks after exposure to {sup 3}H-thymidine was 6.5-fold higher than after exposure to tritium oxide. Comparison of the effects of tritium oxide and X-ray radiation on the yield of DNA double-strand breaks showed that the relative biological efficiency of tritium oxide in a dose range of 3.78-60.26 mGy was 1.6-fold higher than that of X-ray radiation. Improvement of the methods of analysis of DNA double-strand breaks repair foci is highly promising in the context of creation of highly sensitive biodosimetry technologies for tritium compounds in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Distinctly Enhanced Electromagnetic Wave Absorption Properties of FeNi/rGO Nanocomposites Compared with Pure FeNi Alloys

FeNi/rGO nanocomposites were successfully synthesized by a facile one-pot method and demonstrated via powder X-ray diffraction, Raman spectra, X-ray photoelectron spectroscopy, and the scanning electron microscope. The electromagnetic wave absorption properties of the FeNi/rGO nanocomposites exhibit enhanced properties and wide absorption bandwidth compared with that of FeNi alloys. The minimum reflection loss of FeNi/rGO nanocomposites with a thickness of 3.0 mm can reach − 39.86 dB at 11.12 GHz, and the absorption bandwidth is up to 4 GHz. It is believed that the FeNi/rGO nanocomposites can be a best candidate for excellent electromagnetic wave-absorbing materials and widely used in practice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Comparative Study on Microstructures, Magnetic Features and Morphologies of Ternary Fe–Co–Ni Alloy Thin Films Electrochemically Fabricated at Different Deposition Potentials

Electrochemically fabricated ternary Fe–Co–Ni alloy thin films with different chemical compositions were obtained at different deposition potentials. An increase in the deposition potential increased the Ni content while it decreased the Co and Fe contents in the film structure. An anomalous co-deposition behaviour was also studied and the anomalous order of co-deposition was found to be Fe–Ni > Co–Ni > Fe–Co irrespective of deposition potential. Structural characterizations confirmed the presence of single face-centred cubic (fcc) phase structure with [111] preferred crystallographic orientation for all films. The size of the crystallites and the texture degree increased with increasing applied deposition potential. Smaller globular particles occurred on the surface structure of the film fabricated at higher deposition potentials compared to those grown at lower deposition potentials. A decrement detected in the coercive field with increasing applied deposition potential was related to the variations occurred in the chemical composition and the particle size.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative Analysis of the Powers of the Two-Sample Kolmogorov–Smirnov and Anderson–Darling Tests Under Various Alternatives

In this paper we conduct a comparative analysis of the powers of the two-sample Kolmogorov–Smirnov and Anderson–Darling tests under various alternatives using simulation. We consider two examples. In the first example the alternatives to the standard normal distribution are the distributions of the so-called contaminated normal model. We study the influence of a small contamination with a positive shift on the powers of the test. In the second example the alternatives are the logistic and the Laplace distributions, which are symmetric and differ in shape from the normal distribution having a larger kurtosis coefficient and heavier tails.

97 MATHEMATICS AND COMPUTING↗

A Comparative Study of Fracture Toughness at Cryogenic Temperature of Austenitic Stainless Steel Welds

The ITER magnet system is based on the “cable-in-conduit” conductor (CICC) concept, which consists of stainless steel jackets filled with superconducting strands. The jackets provide high strength, limited fatigue crack growth rate and fracture toughness properties to counteract the high stress imposed by, among others, electromagnetic loads at cryogenic temperature. Austenitic nitrogen-strengthened stainless steels have been chosen as base material for the jackets of the central solenoid and the toroidal field system, for which an extensive set of cryogenic mechanical property data are readily available. However, little is published for their welded joints, and their specific performance when considering different combinations of parent and filler metals. Moreover, the impact of post-weld heat treatments that are required for Nb{sub 3}Sn formation is not extensively treated. Welds are frequently responsible for cracks initiated and propagated by fatigue during service, causing structural failure. It becomes thus essential to select the most suitable combination of parent and filler material and to assess their performance in terms of strength and crack propagation at operation conditions. An extensive test campaign has been conducted at 7 K comparing tungsten inert gas (TIG) welds using two fillers adapted to cryogenic service, EN 1.4453 and JK2LB, applied to two different base metals, AISI 316L and 316LN. A large set of fracture toughness data are presented, and the detrimental effect on fracture toughness of post-weld heat treatments (unavoidable for some of the components) is demonstrated. In this study, austenitic stainless steel TIG welds with various filler metals have undergone a comprehensive fracture mechanics characterization at 7 K. These results are directly exploitable and contribute to the cryogenic fracture mechanics properties database of the ITER magnet system. Additionally, a correlation between the impact in fracture toughness and microstructure resulting from the above treatment is provided.

36 MATERIALS SCIENCE↗

Synthesis, Characterization and Comparative Luminescence Studies of Rare-Earth-Doped Gd{sub 2}O{sub 3} Nanoparticles

A facile direct precipitation method was used for the synthesis of luminescence nanomaterial. Gd{sub 2}O{sub 3} doped with rare earth element Eu{sup 3+} is synthesized by polyol route. The synthesized nanoparticles show their characteristic red emission. The nanoparticles are characterized by x-ray diffractometer (XRD), Fourier transform infrared spectroscopy (FTIR), transmission electron microscopy (TEM) and photoluminescence (PL) study. The synthesized nanoparticles are spherical particles with ~ 30 nm size. The photoluminescence studies show the characteristic Eu{sup 3+} red emission. The PL study shows the intensity of the magnetic dipole transition ({sup 5}D{sub 0}→ {sup 7}F{sub 1}) at 592 nm compared to that of the electronic dipole transition ({sup 5}D{sub 0}→ {sup 7}F{sub 2}) at 615 nm. The nanomaterials can show significant application in various display devices and biomedical applications for tracking.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Comparing two methods for determining appropriateness of myocardial perfusion imaging: Criteria from the American College of Cardiology Foundation and the American College of Radiology

Background: Appropriate use criteria (AUC) developed by the American College of Cardiology Foundation and the appropriateness criteria (AC) developed by the American College of Radiology (ACR) are two existing methods of rating appropriateness of myocardial perfusion imaging (MPI). One study found poor agreement of ratings between the two methods. However, using the most contemporary AUC from 2013, it is unknown if poor agreement still exists. Methods: Retrospective cohort investigation comparing patients undergoing nuclear MPI between June 2011 and September 2014. The appropriateness category was determined based on the 2013 AUC (Appropriate, may be appropriate, rarely appropriate) and the 2010 ACR AC (usually appropriate, maybe appropriate, usually not appropriate). The primary outcome was the degree of the agreement between the two methods. Results: The kappa coefficient between ACR AC and AUC was 0.32, P < 0.0001, indicating poor agreement; 40 (8%) patients were classified by the AUC but could not be classified by the ACR AC. Conclusion: The two methods for rating the appropriateness of MPI have poor agreement; a potential for disagreement between providers and payers if only one method is used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stable Isotope Labeling for Improved Comparative Analysis of RNA Digests by Mass Spectrometry

Even with the advent of high throughput methods to detect modified ribonucleic acids (RNAs), mass spectrometry remains a reliable method to detect, characterize, and place post-transcriptional modifications within an RNA sequence. Here we have developed a stable isotope labeling comparative analysis of RNA digests (SIL-CARD) approach, which improves upon the original {sup 18}O/{sup 16}O labeling CARD method. Like the original, SIL-CARD allows sequence or modification information from a previously uncharacterized in vivo RNA sample to be obtained by direct comparison with a reference RNA, the sequence of which is known. This reference is in vitro transcribed using a {sup 13}C/{sup 15}N isotopically enriched nucleoside triphosphate (NTP). The two RNAs are digested with an endonuclease, the specificity of which matches the labeled NTP used for transcription. As proof of concept, several transfer RNAs (tRNAs) were characterized by SIL-CARD, where labeled guanosine triphosphate was used for the reference in vitro transcription. RNase T1 digestion products from the in vitro transcript will be 15 Da higher in mass than the same digestion products from the in vivo tRNA that are unmodified, leading to a doublet in the mass spectrum. Singlets, rather than doublets, arise if a sequence variation or a post-transcriptional modification is present that results in a relative mass shift different from 15 Da. Moreover, the use of the in vitro synthesized tRNA transcript allows for quantitative measurement of RNA abundance. Overall, SIL-CARD simplifies data analysis and enhances quantitative RNA modification mapping by mass spectrometry. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single high-dose irradiation aggravates eosinophil-mediated fibrosis through IL-33 secreted from impaired vessels in the skin compared to fractionated irradiation

We have revealed in a porcine skin injury model that eosinophil recruitment was dose-dependently enhanced by a single high-dose irradiation. In this study, we investigated the underlying mechanism of eosinophil-associated skin fibrosis and the effect of high-dose-per-fraction radiation. The dorsal skin of a mini-pig was divided into two sections containing 4-cm{sup 2} fields that were irradiated with 30 Gy in a single fraction or 5 fractions and biopsied regularly over 14 weeks. Eosinophil-related Th2 cytokines such as interleukin (IL)-4, IL-5, and C–C motif chemokine-11 (CCL11/eotaxin) were evaluated by quantitative real-time PCR. RNA-sequencing using 30 Gy-irradiated mouse skin and functional assays in a co-culture system of THP-1 and irradiated-human umbilical vein endothelial cells (HUVECs) were performed to investigate the mechanism of eosinophil-mediated radiation fibrosis. Single high-dose-per-fraction irradiation caused pronounced eosinophil accumulation, increased profibrotic factors collagen and transforming growth factor-β, enhanced production of eosinophil-related cytokines including IL-4, IL-5, CCL11, IL-13, and IL-33, and reduced vessels compared with 5-fraction irradiation. IL-33 notably increased in pig and mouse skin vessels after single high-dose irradiation of 30 Gy, as well as in irradiated HUVECs following 12 Gy. Blocking IL-33 suppressed the migration ability of THP-1 cells and cytokine secretion in a co-culture system of THP-1 cells and irradiated HUVECs. Hence, high-dose-per-fraction irradiation appears to enhance eosinophil-mediated fibrotic responses, and IL-33 may be a key molecule operating in eosinophil-mediated fibrosis in high-dose-per fraction irradiated skin. - Highlights: • Single high-dose irradiation aggravates eosinophil-mediated fibrosis through IL-33. • Vascular endothelial cells damaged by high-dose radiation secrete IL-33. • Blocking IL-33 suppressed migration of inflammatory cells and cytokine secretion. • IL-33 is a key in eosinophil-mediated fibrosis in high-dose-per-fraction radiation.

60 APPLIED LIFE SCIENCES↗