Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Electron Transfer Dissociation of All Ions at All Times, MS{sup ETD}, in a Quadrupole Time-of-Flight (Q-ToF) Mass Spectrometer

Data-independent mass spectral acquisition is particularly powerful when combined with ultra-performance liquid chromatography (LC) that provides excellent separation of most components present in a given sample. Data-independent analysis (DIA) consists of alternating full MS scans and scans with fragmentation of all ions within a selected m/z range, providing precursor masses and structure information, respectively. Fragmentation spectra are acquired either by sequential isolation and fragmentation of sliding m/z ranges or fragmenting all ions entering the MS instrument with no ion isolation, termed broadband DIA. Previously, broadband DIA has only been possible using collision induced dissociation (CID). Here, we report the use of electron transfer dissociation (ETD) as the fragmentation technique in broadband DIA instead of traditional collision induced dissociation (CID) during MS{sup E}. In this approach, which we refer to as MS{sup ETD}, we implement the inherent benefits provided by ETD, such as discrimination of leucine and isoleucine, in a DIA setup. The combination of DIA analysis and ETD fragmentation with supplemental CID energy provides a powerful platform to obtain information on all precursors and their sequence from a single experiment. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposed Confidence Scale and ID Score in the Identification of Known-Unknown Compounds Using High Resolution MS Data

High-resolution (HR) MS instruments recording HR-full scan allow analysts to go further beyond pre-acquisition choices. Untargeted acquisition can reveal unexpected compounds or concentrations and can be performed for preliminary diagnosis attempt. Then, revealed compounds will have to be identified for interpretations. Whereas the need of reference standards is mandatory to confirm identification, the diverse information collected from HRMS allows identifying unknown compounds with relatively high degree of confidence without reference standards injected in the same analytical sequence. However, there is a necessity to evaluate the degree of confidence in putative identifications, possibly before further targeted analyses. This is why a confidence scale and a score in the identification of (non-peptidic) known-unknown, defined as compounds with entries in database, is proposed for (LC-) HRMS data. The scale is based on two representative documents edited by the European Commission (2007/657/EC) and the Metabolomics Standard Initiative (MSI), in an attempt to build a bridge between the communities of metabolomics and screening labs. With this confidence scale, an identification (ID) score is determined as [a number, a letter, and a number] (e.g., 2D3), from the following three criteria: I, a General Identification Category (1, confirmed, 2, putatively identified, 3, annotated compounds/classes, and 4, unknown); II, a Chromatography Class based on the relative retention time (from the narrowest tolerance, A, to no chromatographic references, D); and III, an Identification Point Level (1, very high, 2, high, and 3, normal level) based on the number of identification points collected. Three putative identification examples of known-unknown will be presented. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared Laser Ablation with Vacuum Capture for Fingermark Sampling

Infrared laser ablation coupled to vacuum capture was employed to collect material from fingermarks deposited on surfaces of different porosity and roughness. Laser ablation at 3 μm was performed in reflection mode with subsequent capture of the ejecta with a filter connected to vacuum. Ablation and capture of standards from fingermarks was demonstrated on glass, plastic, aluminum, and cardboard surfaces. Using matrix assisted laser desorption ionization (MALDI), it was possible to detect caffeine after spiking with amounts as low as 1 ng. MALDI detection of condom lubricants and detection of antibacterial peptides from an antiseptic cream was demonstrated. Detection of explosives from fingermarks left on plastic surfaces as well as from direct deposition on the same surface using gas chromatography mass spectrometry (GC-MS) was shown. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for Continuous Monitoring of Electrospray Ion Formation

A method for continuously monitoring the performance of electrospray ionization without the addition of hardware or chemistry to the system is demonstrated. In the method, which we refer to as SprayDx, cluster ions with solvent vapor natively formed by electrospray are followed throughout the collection of liquid chromatography–selected reaction monitoring data. The cluster ion extracted ion chromatograms report on the consistency of the ion formation and detection system. The data collected by the SprayDx method resemble the data collected for postcolumn infusion of analyte. The response of the cluster ions monitored reports on changes in the physical parameters of the ion source such as voltage and gas flow. SprayDx is also observed to report on ion suppression in a fashion very similar to a postcolumn infusion of analyte. We anticipate the method finding utility as a continuous readout on the performance of electrospray and other atmospheric pressure ionization processes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carbon Nanotube Fiber Ionization Mass Spectrometry: A Fundamental Study of a Multi-Walled Carbon Nanotube Functionalized Corona Discharge Pin for Polycyclic Aromatic Hydrocarbons Analysis

Mass spectrometry continues to tackle many complicated tasks, and ongoing research seeks to simplify its instrumentation as well as sampling. The desorption electrospray ionization (DESI) source was the first ambient ionization source to function without extensive gas requirements and chromatography. Electrospray techniques generally have low efficiency for ionization of nonpolar analytes and some researchers have resorted to methods such as direct analysis in real time (DART) or desorption atmospheric pressure chemical ionization (DAPCI) for their analysis. In this work, a carbon nanotube fiber ionization (nanoCFI) source was developed and was found to be capable of solid phase microextraction (SPME) of nonpolar analytes as well as ionization and sampling similar to that of direct probe atmospheric pressure chemical ionization (DP-APCI). Conductivity and adsorption were maintained by utilizing a corona pin functionalized with a multi-walled carbon nanotube (MWCNT) thread. Quantitative work with the nanoCFI source with a designed corona discharge pin insert demonstrated linearity up to 0.97 (R{sup 2}) of three target PAHs with phenanthrene internal standard. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Compounds Dissolved in Nonpolar Solvents by Electrospray Ionization on Conductive Nanomaterials

Electrospray ionization mass spectrometry (ESI-MS) technique has limitations in analysis of compounds that are dissolved in nonpolar solvents. In this study, ambient ionization of compounds in solvents that are not “friendly” to electrospray ionization, such as n-hexane, is achieved by conductive nanomaterials spray ionization (CNMSI) on nanomaterial emitters, including carbon nanotubes paper and mesodendritic silver covered metal, which applies high voltages to emitters made of these materials without the assistance of polar solvents. Although the time intensity curves (TIC) commonly vary from 4.5% to 23.7% over analyses, protonated molecular ions were found to be the most abundant species, demonstrating good reproducibility of the technique in terms of ionized species. Higher mass spectrometric responses are observed in analyzing nonpolar systems than polar systems. 2-Methoxyacetophenone, 4-methylacetophenone, benzothiazole, quinolone, and cycloheptanone as low as 2 pg in n-hexane can be directly detected using the developed method. The developed technique expands the analysis capability of ESI-MS for direct, online analysis of nonpolar systems, such as low polarity extracts, normal phase liquid chromatography eluates, and synthetic mixtures. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrospray Ionization with High-Resolution Mass Spectrometry as a Tool for Lignomics: Lignin Mass Spectrum Deconvolution

The capability to characterize lignin, lignocellulose, and their degradation products is essential for the development of new renewable feedstocks. Electrospray ionization high-resolution time-of-flight mass spectrometry (ESI-HR TOF-MS) method was developed expanding the lignomics toolkit while targeting the simultaneous detection of low and high molecular weight (MW) lignin species. The effect of a broad range of electrolytes and various ionization conditions on ion formation and ionization effectiveness was studied using a suite of mono-, di-, and triarene lignin model compounds as well as kraft alkali lignin. Contrary to the previous studies, the positive ionization mode was found to be more effective for methoxy-substituted arenes and polyphenols, i.e., species of a broadly varied MW structurally similar to the native lignin. For the first time, we report an effective formation of multiply charged species of lignin with the subsequent mass spectrum deconvolution in the presence of 100 mmol L{sup −1} formic acid in the positive ESI mode. The developed method enabled the detection of lignin species with an MW between 150 and 9000 Da or higher, depending on the mass analyzer. The obtained M{sub n} and M{sub w} values of 1500 and 2500 Da, respectively, were in good agreement with those determined by gel permeation chromatography. Furthermore, the deconvoluted ESI mass spectrum was similar to that obtained with matrix-assisted laser desorption/ionization (MALDI)-HR TOF-MS, yet featuring a higher signal-to-noise ratio. The formation of multiply charged species was confirmed with ion mobility ESI-HR Q-TOF-MS. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational Removal of Undesired Mass Spectral Features Possessing Repeat Units via a Kendrick Mass Filter

Polymers are a common component of chemical background which complicates data analysis and can impair interpretation. Undesired chemical background cannot always be addressed via pre-analytical methods, chromatography, or existing data processing methods. The Kendrick mass filter (KMF) is presented for the computational removal of undesired signals present in MS{sup 1} spectra. The KMF is analogous to mass defect filtering but utilizes homology information via Kendrick mass scaling in combination with chromatographic retention time and the number of observed signals. The KMF is intended to assist in situations in which current data processing methods to remove background, e.g., blank subtraction, are either not possible or effective. The major parameters affecting KMF were investigated using PEG 400 and NIST standard reference material 1950 (metabolites in human plasma). Further exploration of the KMF performance was tested using an extract of a swab known to contain polymers. An illustrative real-world example of skin analysis with polymeric signal is discussed. The KMF is also able to provide a high-level view of the compositionality of data regarding the presence of signals with repeat units and indicate the presence of different polymers. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Quantification Method Using Electrochemical Mass Spectrometry

Mass spectrometry-based quantification method has advanced rapidly. In general, the methods for accurate quantification rely on the use of authentic target compounds or isotope-labeled compounds as standards, which might be not available or difficult to synthesize. To tackle this grand challenge, this paper presents a novel approach, based on electrochemistry (EC) combined with mass spectrometry (MS). In this approach, a target compound is allowed to undergo electrochemical oxidation and then subject to MS analysis. The oxidation current recorded from electrochemistry (EC) measurement provides information about the amount of the oxidized analyte, based on the Faraday’s Law. On the other hand, the oxidation reaction yield can be determined from the analyte MS signal changes upon electrolysis. Therefore, the total amount of analyte can be determined. In combination with liquid chromatography (LC), the method can be applicable to mixture analysis. The striking strength of such a method for quantitation is that neither standard compound nor calibration curve is required. Various analyte molecules such as dopamine, norepinephrine, and rutin as well as peptide glutathione in low quantity were successfully quantified using our method with the quantification error ranging from − 2.6 to + 4.6%. Analyte in a complicated matrix (e.g., uric acid in urine) was also accurately measured. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TiO{sub 2} Photocatalyzed Oxidation of Drugs Studied by Laser Ablation Electrospray Ionization Mass Spectrometry

In drug discovery, it is important to identify phase I metabolic modifications as early as possible to screen for inactivation of drugs and/or activation of prodrugs. As the major class of reactions in phase I metabolism is oxidation reactions, oxidation of drugs with TiO{sub 2} photocatalysis can be used as a simple non-biological method to initially eliminate (pro)drug candidates with an undesired phase I oxidation metabolism. Analysis of reaction products is commonly achieved with mass spectrometry coupled to chromatography. However, sample throughput can be substantially increased by eliminating pretreatment steps and exploiting the potential of ambient ionization mass spectrometry (MS). Furthermore, online monitoring of reactions in a time-resolved way would identify sequential modification steps. Here, we introduce a novel (time-resolved) TiO{sub 2}-photocatalysis laser ablation electrospray ionization (LAESI) MS method for the analysis of drug candidates. This method was proven to be compatible with both TiO{sub 2}-coated glass slides as well as solutions containing suspended TiO{sub 2} nanoparticles, and the results were in excellent agreement with studies on biological oxidation of verapamil, buspirone, testosterone, andarine, and ostarine. Finally, a time-resolved LAESI MS setup was developed and initial results for verapamil showed excellent analytical stability for online photocatalyzed oxidation reactions within the set-up up to at least 1 h. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Self-Supplied Liquid Injection Field Desorption/Ionization Ion Source for an Orthogonal Time-of-Flight Instrument

A new implementation of a dedicated ion source for field ionization (FI), field desorption (FD), and liquid injection field desorption/ionization (LIFDI) for the JEOL AccuTOF GC series of orthogonal-acceleration time-of-flight instruments is presented. In contrast to existing implementations, this third-party LIFDI probe and source combination does not require the exchange of the entire ion source comprising ion source block and lens stack to switch from electron ionization (EI) to LIFDI. Rather, the methods may be swapped conveniently by only exchanging the ion source block for a mechanical probe guide and inserting the LIFDI probe in place of the standard direct insertion probe (DIP) via the vacuum lock. Further, this LIFDI setup does not require any changes of the electronics or software of the AccuTOF mass spectrometer because it is self-supplied in terms of power supply, observation optics, and computer control. The setup offers advanced FI/FD/LIFDI control features such as emission-controlled emitter heating current and emitter flash baking during elongated runs as required for gas chromatography-FI-mass spectrometry (MS). The LIFDI source and probe and its operation are reported in detail. FI spectra of the volatile analytes toluene, heptane, and pentafluoroiodobenzene are presented. LIFDI operation is demonstrated for the analysis of the saturated hydrocarbon dotriacontane and the low-mass hydrocarbon polymers polystyrene 484 and polystyrene 1050. Further, the air-sensitive 2nd-generation Hoveyda–Grubbs catalyst is analyzed by LIFDI-MS. For comparison with long-established LIFDI instrumentation, some of the spectra obtained with the new setup are also compared with those from a double-focusing magnetic sector instrument. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of gas emissions from stored softwood chips as solid biofuels

Western Red Cedar (WRC) is one of the abundant softwood species, which is considered as a good source of biofuel. This paper aims at quantifying gas emissions from stored WRC woodchips and studying the potential health impact during storage and transportation. Experiments were conducted using lab-scale reactors for a range of temperatures under both non-aerobic and aerobic conditions depending on oxygen level. Results from tests using non-aerobic reactors showed that the highest carbon dioxide emission factor of 2.8 g/kg dry matter (DM) was observed at 20 A degrees C for a storage period of 2 months. Although the carbon monoxide emission factor was much lower at 0.03 g/kg DM, it increased with increasing temperatures due to chemical oxidation. Carbon dioxide and carbon monoxide emissions from the aerobic reactors exhibited similar trends as the non-aerobic reactors with respect to the effect of temperature. Total gas emissions were higher from the aerobic reactors compared with those from non-aerobic reactors. Results from the qualitative gas chromatography-mass spectrometry analysis indicated a range of volatile organic compounds was emitted from the stored WRC woodchips. Some of these volatile organic compounds might be associated with the characteristic pungent smell of WRC which could cause odor nuisance to the neighboring community. Here, the total volatile organic compounds concentration was found to be positively correlated with temperature. At the end of the storage period, percent DM loss was below 1 % for both the non-aerobic and aerobic reactors, reaffirming the decay-resistance characteristics of WRC.

09 BIOMASS FUELS↗

Analytical Methods for Biomass Characterization and Conversion

Analytical Methods for Biomass Characterization and Conversion is a thorough resource for researchers, students and professors who investigate the use of biomass for fuels, chemicals and products. Advanced analytical chemistry methods and techniques can now provide detailed compositional and chemical measurements of biomass, biomass conversion process streams, intermediates and products. This volume from the Emerging Issues in Analytical Chemistry series brings together the current knowledge on each of these methods, including spectroscopic methods (Fourier Transform Infrared Spectroscopy, Near-infrared Spectroscopy, Solid State Nuclear Magnetic Resonance), pyrolysis (Gas Chromatography/Mass Spectrometry), Liquid Chromatography/High Performance Liquid Chromatography, Liquid Chromatography/Mass Spectrometry, and so on.

09 BIOMASS FUELS↗

Identification of phosphorylated butyrylcholinesterase in human plasma using immunoaffinity purification and mass spectrometry

Paraoxon (diethyl 4-nitrophenyl phosphate) is an active metabolite of the common insecticide parathion and is acutely toxic due to the inhibition of cholinesterase (ChE) activity in the nervous systems. The Inhibition of butyrylcholinesterase (BChE) activity by paraoxon is due to the formation of phosphorylated BChE adduct, and the detection of the phosphorylated BChE adduct in human plasma can serve as an exposure biomarker of organophosphate pesticides and nerve agents. In this study, we performed immunoaffinity purification and liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis for identifying phosphorylated BChE in human plasma treated by paraoxon. BChE was captured by biotinylated anti-BChE polyclonal antibodies conjugated to streptavidin magnetic beads. Western blot analysis showed that the antibody was effective to recognize both native and modified BChE with high specificity. The exact phosphorylation site of BChE was confirmed on Serine 198 by MS/MS with a 108 Da modification mass and accurately measured parent ion masses. The phosphorylated BChE peptide was also successfully detected in the immunoaffinity purified sample from paraoxon treated human plasma. Thus, immunoaffinity purification combined with mass spectrometry represents a viable approach for the detection of paraoxon-modified BChE and other forms of modified BChE as exposure biomarkers of organophosphates and nerve agents.

59 BASIC BIOLOGICAL SCIENCES↗

Fluorinated ionic liquids as gas chromatographic stationary phases for the separation of volatile per- and polyfluoroalkyl substances

Background Here, the production of fluorinated organic compounds in the manufacturing, semiconductor, and pharmaceutical industries has increased exponentially over the past decade. This rapid growth has created an urgent need for efficient chromatographic platforms capable of selectively separating these compounds from complex mixtures, not only to support industrial quality control and waste management practices, but also to enable reliable environmental monitoring of volatile fluorinated contaminants. Conventional GC stationary phases lack the fluorophilic interactions needed for highly fluorinated analytes. Consequently, there is a clear demand for specialized stationary phases designed to improve chromatographic retention and selectivity for these compounds. Results Three stationary phases composed of fluorinated ionic liquids (ILs) with varied extent of fluorination were prepared to study fluorophilic interactions with fluorinated/non-fluorinated probe molecules by gas chromatography (GC). IL stationary phases featuring linear and branched perfluoroalkyl moieties, as well as a branched alkyl moiety, were systematically investigated. Chromatographic performance was examined using fluorinated compounds and their hydrocarbon analogs, including CF 3 -substituted aromatics, aliphatic alcohols, fluorotelomer alcohols (FTOHs), and perfluoroalkenes. Measurements on 5 m and 20 m columns revealed that the IL possessing branched alkyl provided stronger dispersive and hydrogen bonding interactions toward non-fluorinated aromatic and long-chain alcohols, whereas the fluorinated ILs enhanced retention of highly fluorinated FTOHs and perfluorodecene. Comprehensive two-dimensional GC (GC × GC), using a nonpolar primary column coupled with secondary columns featuring cross-bonded poly(trifluoropropylmethyl siloxane) (Rtx-200 ms), the branched fluorinated IL, or the branched non-fluorinated IL, highlighted complementary selectivity with the branched fluorinated IL providing the strongest interactions with fluorinated analytes. Significance These results demonstrate that fluorinated IL stationary phases are promising alternatives to conventional polysiloxane stationary phases for improving the separation of per- and polyfluoroalkyl substances and related fluorinated compounds. By correlating IL structure with fluorophilic interactions, this work establishes design principles for GC stationary phases that enable enhanced selectivity for highly fluorinated analytes while maintaining complementary interactions with non-fluorinated compounds.

Comprehensive two-dimensional GC↗

Rare-earth element fractionation in uranium ore and its U(VI) alteration minerals

We developed a cation exchange chromatography method employing sulfonated polysterene cation resin (DOWEX AG50-X8) in order to separate rare-earth elements (REEs) from uranium-rich materials. The chemical separation scheme is designed to reduce matrix effects and consequently yield enhanced ionization efficiencies for concentration determinations of REEs without significant fractionation using solution mode-inductively coupled plasma mass spectrometry (ICP-MS) analysis. This method was then applied to determine REE abundances in four uraninite (ideally UO 2 ) samples and their associated U(VI) alteration minerals. In three of the samples analyzed, the concentration of REEs for primary uraninite are higher than those for their corresponding secondary uranium alteration phases. The results for U(VI) alteration minerals of two samples indicate enrichment of the light REEs (LREEs) over the heavy REEs (HREEs). This differential mobilization is attributed to differences in the mineralogical composition of the U(VI) alteration. There is a lack of fractionation of the LREEs in the uraninite alteration rind that is composed of U(VI) minerals containing Ca 2+ as the interlayer cation (uranophane and bequerelite); contrarily, U(VI) alteration minerals containing K + and Pb 2+ as interlayer cations (fourmarierite, dumontite) indicate fractionation (enrichment) of the LREEs. Our results have implications for nuclear forensic analyses since a comparison is reported between the REE abundances for the CUP-2 (processed uranium ore) certified reference material and previously determined values for uranium ore concentrate (UOC) produced from the same U deposit (Blind River/Elliott Lake, Canada). UOCs represent the most common form of interdicted nuclear material and consequently is material frequently targeted for forensic analysis. The comparison reveals similar chondrite normalized REE signatures but variable absolute abundances. Based on the results reported here, the latter may be attributed to the differing REE abundances between primary ore and associated alteration phases, and/or is related to varying fabrication processes adopted during production of UOC.

58 GEOSCIENCES↗

Improved titanium-44 purification process for establishing a high apparent molar activity titanium-44/scandium-44 generator

44 Sc-radiopharmaceuticals are gaining more interest but still lack availability. The proof of principle of a 44 Ti/ 44 Sc generator, which can produce 44 Sc daily, has been established but with some limitations and drawbacks. Despite recent advances, separation of 44 Ti from massive quantities of scandium target material is still cumbersome. Here, in this work, the improved radiochemical separation of 44 Ti from residual scandium target material was carried out by precipitation of Sc with fluoride ions. Furthermore, two approaches were used to set up a high apparent molar activity small-scale generator. The first method relied on extraction chromatography for fine purification using a DGA resin, followed by loading of the purified 44 Ti onto a ZR resin column. In the second method, 44 Ti was loaded on the ZR resin directly after the precipitation step. This second method was used to set up a generator of 370 kBq and evaluate by radiolabeling. An apparent molar activity of 2 MBq/nmol was obtained for the radiolabeling with DOTA, the most common and suitable chelate for scandium. This result is comparable with previously published data on 44m/44 Sc.

44Sc↗

Separation of terbium from proton-irradiated gadolinium oxide targets – development of an effective, scalable and automatable process

This work reports an effective and scalable radiochemical separation process for isolating terbium from Gd 2 O 3 . The separation process uses three commercially available extraction chromatography resin columns, has been implemented on a computer-controlled chemistry module, and tested with 100 mg quantities of proton-irradiated nat Gd 2 O 3 . Here, the 4-hour separation procedure isolated radioterbium in 1.3 mL of 0.01 M HCl with 80 ±8% radiochemical yield and a Gd decontamination factor >(1.2 ± 0.3)·10 5 .

Adjacent lanthanide separation↗