Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Roles of Urban Tree Canopy and Buildings in Urban Heat Island Effects: Parameterization and Preliminary Results

Urban heat island (UHI) effects can strengthen heat waves and air pollution episodes. In this study, the dampening impact of urban trees on the UHI during an extreme heat wave in the Washington, D.C., and Baltimore, Maryland, metropolitan area is examined by incorporating trees, soil, and grass into the coupled Weather Research and Forecasting model and an urban canopy model (WRF-UCM). By parameterizing the effects of these natural surfaces alongside roadways and buildings, the modified WRF-UCM is used to investigate how urban trees, soil, and grass dampen the UHI. The modified model was run with 50% tree cover over urban roads and a 10% decrease in the width of urban streets to make space for soil and grass alongside the roads and buildings. Results show that, averaged over all urban areas, the added vegetation decreases surface air temperature in urban street canyons by 4.1 K and road-surface and building-wall temperatures by 15.4 and 8.9 K, respectively, as a result of tree shading and evapotranspiration. These temperature changes propagate downwind and alter the temperature gradient associated with the Chesapeake Bay breeze and, therefore, alter the strength of the bay breeze. The impact of building height on the UHI shows that decreasing commercial building heights by 8 m and residential building heights by 2.5 m results in up to 0.4-K higher daytime surface and near-surface air temperatures because of less building shading and up to 1.2-K lower nighttime temperatures because of less longwave radiative trapping in urban street canyons.

urban vegetation↗

NASA Power: Global Solar Insolation, Meteorological Parameter Data, and Web Services to Support Sustainable Building Design and Operations

The buildings industry is currently striving to adopt green solutions to make infrastructure more energy-efficient in order to meet the 2050 net-zero climate goals. This planning requires reliable environmental datasets that are crucial in designing, building, and maintaining our world’s-built environment, as well as other energy-related processes and investments. This webinar for the National Institute of Building Sciences provides an overview of NASA’s Prediction Of Worldwide Energy Resources (POWER) Project that informs decision-making and development for sustainable building design and operations by enabling public open discovery, efficient access, and convenient distribution of NASA’s Earth Observations and global atmospheric model datasets. POWER’s datastore is comprised of solar radiation and surface meteorology parameters, spanning nearly 40 years of hourly data, that are easily accessible via several access methods and tools to support three focus areas: 1) renewable energy deployment and management, 2) sustainable infrastructure, and 3) agroclimatology applications. POWER and NASA Earth Science both plan future data parameters, updated tools, and improved observations that could directly support U.S. and international sustainable development goals, climate strategies, and building information modeling. To this end, solar data from several NASA projects and meteorological data from NASA assimilation models have already been reformatted and disseminated to the public via a user-friendly web GIS-enabled based data portal through the POWER Project. POWER data is analysis-ready and accessible through an Application Programming Interface (API), ArcGIS Image Services, and the project’s Data Access Viewer enhanced (DAVe), an interactive online tool. The POWER DAVe also features data consistent with ASHRAE Climate Design Conditions and has developed web image services showing Building Climate Zones and their variability. Through those tools, the data can be downloaded into multiple formats that support the infrastructure community, including CSV and Energy Plus Weather (EPW). POWER’s entire data product catalog is available through Amazon Web Services (AWS) Open Data Registry (ODR) via a free and publicly accessible Simple Storage Service (S3). This webinar provides a full overview of the NASA POWER Project's data and services developed in collaboration with the sustainable infrastructure community. Examples of how the renewable energy and building communities have utilized POWER data products to make decisions and a preview of future data product expansion, including climate projections, and web services will also be provided. Additionally, use case stories from our broad community of users will be presented.

Paul W. Stackhouse↗

A Prospective Study of Ventilation Rates and Illness Absence in California Office Buildings

Background – This study investigated the associations of ventilation rates (VRs), estimated from indoor CO2 concentrations, in offices with the amount of respiratory infections, illness absences, and building-related health symptoms in occupants. Methods – Office buildings were recruited from three California climate zones. In one or more study spaces within each building, real-time logging sensors measured carbon dioxide, temperature, and relative humidity for one year. Ventilation rates were estimated using daily peak CO2 levels, and also using an alternative metric. Data on occupants and health outcomes were collected through web-based surveys every three months. Multivariate models were used to assess relationships between metrics of ventilation rate or CO2 and occupant outcomes. For all outcomes, negative associations were hypothesized with VR metrics, and positive associations with CO2 metrics. Results – Difficulty recruiting buildings and low survey response limited sample size and study power. In 16 studied spaces within 9 office buildings, VRs were uniformly high over the year, from twice to over nine times the California office VR standard (7 L/s or 15 cfm per person). VR and CO2 metrics had no statistically significant relationships with occupant outcomes, except for a small significantly positive association of the alternative VR metric with respiratory illness-related absence, contrary to hypotheses. Conclusions– The very high time-averaged VRs in the California office buildings studied presumably resulted from “economizer cycles” bringing in large volumes of outdoor air; however, in almost all buildings even the estimated minimum VRs supplied (without the economizer) substantially exceeded the minimum required VR. These high VRs may explain the absence of hypothesized relationships with occupant outcomes. Among uniformly high VRs, little variation in contaminant concentration and occupant effects would be expected. These findings may provide initial evidence for an upper bound of the range of VRs within which increased VRs provide benefits in reducing illness absence.

54 ENVIRONMENTAL SCIENCES↗

Development of Residential Prototype Building Models and Analysis System for Large-Scale Energy Efficiency Studies Using EnergyPlus

ABSTRACT: Recent advances in residential building energy efficiency and codes have resulted in increased interest in detailed residential building energy models using the latest energy simulation software. One of the challenges of developing residential building models to characterize new residential building stock is to allow for flexibility to address variability in house features like geometry, configuration, HVAC systems etc. Researchers solved this problem in a novel way by creating a simulation structure capable of creating fully-functional EnergyPlus batch runs using a completely scalable residential EnergyPlus template system. This system was used to create a set of thirty-two residential prototype building models covering single- and multifamily buildings, four common foundation types and four common heating system types found in the United States (US). A weighting scheme with detailed state-wise and national weighting factors was designed to supplement the residential prototype models. The complete set is designed to represent a majority of new residential construction stock. The entire structure consists of a system of utility programs developed around the core EnergyPlus simulation engine to automate the creation and management of large-scale simulation studies with minimal human effort. The simulation structure and the residential prototype building models have been used for numerous large-scale studies, one of which is briefly discussed in this paper.

Mendon, Vrushali V.↗

Advanced human-machine interface for collaborative building control

A system for collaborative energy management and control in a building, including an energy management controller, one or more occupant HMIs that supports two-way communication between building occupants and a facility manager, and between building occupants and the energy management controller, and a facility manager HMI that supports two-way communication between the facility manager and the building occupants, and between the facility manager and the energy management controller, in which the occupant HMI allows building occupants to provide temperature preferences to the facility manager and the energy management controller, and the facility manager HMI allows the facility manager to configure an energy policy for the building as a set of rules and to view occupants' aggregated temperature preferences, and the energy management controller determines an optimum temperature range that resolves conflicting occupant temperature preferences and occupant temperature preferences that conflict with the facility manager's energy policy for the building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Airtightness of Commercial Building Envelopes: Where are we and where could we go?

Air leakage in commercial buildings accounts for about one quad of energy annually; therefore, efforts have been put in place to decrease this energy penalty. Data from blower door tests indicate that the airtightness of new building envelopes has been improving in certain niches because of requirements set by local governments and the US Army Corps of Engineers (USACE), as well as the availability of air barrier consultants. Advances in air barrier technologies and construction practices have also contributed to these improvements. Even with these promising results, efforts have been slow to revise building codes so that they establish a maximum air leakage rate requirement for new buildings and envelope retrofits. This paper summarizes current techniques used to conduct whole building air leakage tests, where these tests are mandatory, how the air leakage rate of buildings appears to be decreasing, and what stakeholders think about blower door tests. The paper also includes the nationwide source energy and financial savings potential for standalone retail buildings that were calculated using a newly developed simulation tool that more accurately estimates the effect of air leakage on energy use.

Hun, Diana E.↗

An Assessment of Impacts on Electric End-Use Load Profile of a Typical Residential Building from a Ground Source Heat Pump Systems Integrated with Underground Thermal Energy Storage

Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.

Shi, Liang↗

Metrics for Interzonal Dispersion Assessment of Airborne SARS-CoV-2 Within Office Buildings

High ventilation rate is increasingly considered as a mitigation strategy in the rapid spread of COVID-19 in existing buildings in addition to other options like UVGI and added filtration. However, this and other similar measures may also impact energy use and the efficiency of the buildings in which they are installed. Without concrete metrics, the impact of all these potential changes to the system cannot be properly assessed relative to the other impacts the measures might have, including additional energy use, added operation and maintenance costs, and reduced system life. Multizone airflow and contaminant transport simulations involving parameters such as infiltration rate, system configuration, and level of occupancy can provide critical information on relative risk distribution within a building. In this study, prototype airflow models are used to assess the degree to which ventilation-related measures can mitigate the spread of a virus like SARS-CoV-2 in a similar way that prototype energy models are used to study energy efficiency measures. A new detailed medium-sized office building prototype model is developed using the CONTAM software to represent contaminant transport in buildings like those modeled by the U.S. Department of Energy’s detailed medium office prototype model. The goal of this study is to generate a set of suitable metrics that will give a whole-building picture of airborne SARS-CoV-2 virus distributions across the different zones of the building under different parameters and scenarios.

DeGraw, Jason↗

System and method for characterization of retrofit opportunities in building using data from communicating thermostats

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

System and method for characterization of retrofit opportunities in building using data from interval meters

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

Using Wi-Fi Location-Based Services (LBS) for Commercial Building Occupancy Sensing

From May 2019 through October 2022, this DOE-funded project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at two commercial buildings located in Minnesota and Wisconsin.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile: Preprint

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

advanced metering infrastructure (AMI)↗

Indoor Radon Measurements from Residential Buildings with Basements in a Community with Potential LLRW Contamination - 19566

The Port Hope Area Initiative (PHAI) represents the Government of Canada's commitment to the cleanup and safe, local, long-term management of historic low-level radioactive waste (LLRW) in two Southern Ontario municipalities-Port Hope and Clarington. The PHAI (see reference for internet address) is based on community-recommended solutions for the cleanup and safe long-term management of approximately 1.7 million cubic meters of LLRW. It is currently one of Canada's largest environmental remediation projects at a cost of over one billion dollars. Canadian Nuclear Laboratories (CNL) is implementing the PHAI on behalf of Atomic Energy of Canada Limited, a Federal Crown Corporation. An initial characterization and remediation program in the urban area of Port Hope was conducted from 1976 to 1981. The waste is the result of radium and uranium processing in Port Hope by the former Federal Crown Corporation Eldorado Nuclear Limited between 1933 and 1988. One contaminant of concern in the LLRW is radium-226 (Ra-226) which may lead to elevated indoor levels of radon-222 (Rn-222) indoors. As part of CNL's implementation of the PHAI, Arcadis is conducting the Port Hope Project Property Radiological Survey of approximately 4,800 small-scale sites to identify 1) properties that have not been affected by historic operations and 2) properties that have residual historic low-level radioactive waste impacts requiring remediation either for soils or for interior contamination or both. Over the last six years, a component of the Small Scale Sites (SSS) characterization surveys have measured radon concentrations in essentially all buildings in Port Hope using alpha-track detectors. All properties had subsurface characterization including analytical characterization and lithology following the radon measurement reporting to measure if soil concentrations exceeded the PHAI Cleanup Criteria (PHAI CC) for Ra-226 of 0.29 Bq/g. Buildings with radon gas exceeding a trigger level of 200 becquerels per cubic meter (Bq/m{sup 3}) or those with ventilation systems required investigation of soil concentrations around the perimeter of the building. Ra-226 concentrations above the background level of 0.05 Bq/g due to LLRW sources were forwarded to create remedial action plans (RAPs) to remove the contamination near the building. The SSS surveys provide a substantive data set on the approximately 3,000 properties measured to date with interior Rn-222 gas measurements and descriptions of the physical characteristics of the buildings, the lithology of soils near the buildings and the measurements of Ra-226 concentration in the soils on the property. Consideration of the potential for contribution from non-LLRW Ra-226 from natural sources or coal ash was required on some properties. This paper describes the data and exploratory analysis of the relationship(s) between LLRW and non-LLRW factors that affect the variation in indoor radon concentrations. Historical information on the urban area, the measured Ra-226 concentration and the age of the building were correlated with radon concentrations. A large variety of native soils are found in the complex terrain and the type of native soil was correlated with the radon concentrations. A statistical analysis to address the impact of co-related explanatory variables to model indoor radon concentrations is planned when the SSS activities are complete. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building Automation

In this chapter, we focus on both need-based and vision-based control innovation for building automation for HVAC systems. After providing a brief background that describes different HVAC architectures and products, we describe the control challenges and opportunities from a needs-based point of view, at the equipment level, the systems level, and the building level. At the equipment level, increased use of continuously variable actuation such as variable speed compressors and fans, requires application of robust multivariable control that must consider various types of nonlinear behavior across increasingly larger operating envelopes. The objective at this level is to achieve robust and energy efficient operation. At the system level, coupled and interactive dynamics among subsystems are increasingly important to consider, and functional integration of these subsystems, along with set points and operating schedules are designed to minimize energy consumption and improve occupant comfort. At the building level, issues such as integration among other building systems, such as the building envelope and the electric grid, offer opportunities to develop new types of demand response and grid-interactive behaviors and technologies. At the higher levels, system dynamics and robust stability are less of an issue, similar to process control applications, while optimization and integration are more important, although dynamic stability is increasing an issue at the higher levels too. From a vision-driven innovation point of view, we describe three areas that will require sustained research efforts and will eventually impact building automation: Digital Twins, Model Predictive Control, and Grid Interactive Buildings.

Bortoff, Scott↗

From IMPEL to Impact: Lessons Learned in Accelerating Innovative Building Technologies

The built environment is a complex ecosystem of social institutions and physical infrastructures. Innovation and entrepreneurship in the building industry are critical levers for market transformation toward equitable climate action. However, climate tech innovation for the built environment is not moving fast enough for global needs, and it lacks fundamental diversity, leading to inequitable outcomes. IMPEL (Incubating Market-propelled Entrepreneurial-mindset at the Labs and Beyond) - a U.S. Department of Energy incubator–addresses these critical issues. Over five years, IMPEL has enabled 250 innovators, including 55% women and diverse founders, to accelerate their buildings and clean energy technologies towards market and climate impact. IMPEL provides access to strategic mentoring and coaching, carbon tools training, testbeds, and powerful public-private pipelines, including industry demonstrations, non-dilutive grants, and venture capital networks. The IMPEL innovation ecosystem has accelerated the pace of innovation and market adoption of building decarbonization technologies. In this paper, leverage the IMPEL stakeholder ecosystem - from innovators to investors and product industry to policymakers - to analyze the critical barriers to decarbonization still encountered in the building industry. We study the IMPEL approach and highlight lessons learned that benefit young businesses pursuing innovative building and building-edge energy technologies to develop new ideas and products. Finally, we propose a ‘market forming’ framework to improve the quality and efficiency of the entrepreneurial ecosystem in the building industry. This framework could scale vetted technologies and the participation of diverse founders to de-risk the climate tech

Singh, Reshma↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

BRE‐X Emissions Database for End‐of‐Life Scenarios of Selective Building Construction Materials to Enable Circular Economy in Construction

In the United States, construction and demolition debris predominately end up in landfills with minimal end‐of‐life Re‐X (recover, recycle, reuse, etc.) scenarios, resulting in large environmental impacts and lost opportunities for material recovery. Except for concrete and metals, which seem to have a few well‐defined end‐of‐life pathways, there seems to be a lack of well‐documented end‐of‐life scenarios for other construction materials, let alone their emissions data. Hence, there is a need for documented end‐of‐life Re‐X scenarios and end‐of‐life data of more building materials to motivate widespread use of Re‐X strategies in building design. This paper outlines the efforts of the National Renewable Energy Laboratory, Carbon Leadership Forum, Building Transparency, and Skidmore, Owings & Merrill to (a) create an open‐access BRE‐X (Building Re‐X) end‐of‐life emissions database consisting of greenhouse gas emissions data associated with various end‐of‐life scenarios for a select list of high‐impact building construction materials, and (b) integrate the BRE‐X end‐of‐life emissions database with CAD/BIM/LCA tools for evaluating various end‐of‐life scenarios. The paper also presents a few existing life cycle inventory databases that contain sparse amounts of end‐of‐life data for a few construction materials and their limitations in terms of scaling and data consolidation. Finally, a sample of how the collected data can be ingested into whole‐building LCA tools using open data formats and a public access link to the BRE‐X end‐of‐life emissions database is also included.

36 MATERIALS SCIENCE↗

Informing electrification strategies of residential neighborhoods with urban building energy modeling

Electrifying end uses is a key strategy to reducing GHG emissions in buildings. However, it may increase peak electricity demand that triggers the need to upgrade the existing power distribution system, leading to delays in electrification and needs of significant investment. There is also concern that building electrification may cause an increase of energy costs, leading to further energy burden for low-income communities. This study uses the urban scale building modeling tool CityBES to assess the electrification impacts of more than 43,000 residential buildings in a neighborhood of Portland, Oregon, USA. Energy efficiency upgrades were investigated on their potential to mitigate the increase of peak electricity demand and energy burden. Simulation results from the calibrated EnergyPlus models show that electrification with heat pumps for space heating and cooling as well as for domestic water heating can reduce CO2e emissions by 38%, but increase peak electricity demand by about 9% from the baseline building stock. Combining electrification measures and energy efficiency upgrades can reduce CO2e emissions by 48% while reducing peak electricity demand by 6% and saving the median household energy costs by 28%. City and utility decision makers should consider integrating energy efficiency upgrades with electrification measures as an effective residential building electrification strategy, which significantly reduces carbon emissions, caps or even decreases peak demand while reducing energy burden of residents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗