REC-2006—A Fractionated Extract of Podophyllum hexandrum Protects Cellular DNA from Radiation-Induced Damage by Reducing the Initial Damage and Enhancing Its Repair In Vivo

Podophyllum hexandrum, a perennial herb commonly known as the Himalayan May Apple, is well known in Indian and Chinese traditional systems of medicine. P. hexandrum has been widely used for the treatment of venereal warts, skin infections, bacterial and viral infections, and different cancers of the brain, lung and bladder. This study aimed at elucidating the effect of REC-2006, a bioactive fractionated extract from the rhizome of P. hexandrum, on the kinetics of induction and repair of radiation-induced DNA damage in murine thymocytes in vivo. We evaluated its effect on non-specific radiation-induced DNA damage by the alkaline halo assay in terms of relative nuclear spreading factor (RNSF) and gene-specific radiation-induced DNA damage via semi-quantitative polymerase chain reaction. Whole body exposure of animals with gamma rays (10 Gy) caused a significant amount of DNA damage in thymocytes (RNSF values 17.7 ± 0.47, 12.96 ± 1.64 and 3.3 ± 0.014) and a reduction in the amplification of β-globin gene to 0, 28 and 43% at 0, 15 and 60 min, respectively. Administrating REC-2006 at a radioprotective concentration (15 mg kg –1 body weight) 1 h before irradiation resulted in time-dependent reduction of DNA damage evident as a decrease in RNSF values 6.156 ± 0.576, 1.647 ± 0.534 and 0.496 ± 0.012, and an increase in β-globin gene amplification 36, 95 and 99%, at 0, 15 and 60 min, respectively. REC-2006 scavenged radiation-induced hydroxyl radicals in a dose-dependent manner stabilized DPPH free radicals and also inhibited superoxide anions. Various polyphenols and flavonoides present in REC-2006 might contribute to scavenging of radiation-induced free radicals, thereby preventing DNA damage and stimulating its repair.

59 BASIC BIOLOGICAL SCIENCES↗

LARP Long Nb3Sn Quadrupole Design

A major milestone for the LHC Accelerator Research Program (LARP) is the test, by the end of 2009, of two 4m-long quadrupole magnets (LQ) wound with Nb{sub 3}Sn conductor. The goal of these magnets is to be a proof of principle that Nb{sub 3}Sn is a viable technology for a possible LHC luminosity upgrade. The design of the LQ is based on the design of the LARP Technological Quadrupoles, presently under development at FNAL and LBNL, with 90-mm aperture and gradient higher than 200 T/m. The design of the first LQ model will be completed by the end of 2007 with the selection of a mechanical design. In this paper we present the coil design addressing some fabrication technology issues, the quench protection study, and three designs of the support structure.

43 PARTICLE ACCELERATORS↗

Final Development and test preparation of the first 3.7m long Nb3Sn quadrupole by LARP

The test of the first LARP (LHC Accelerator Research Program) Long Quadrupole is a significant milestone toward the development of Nb{sub 3}Sn quadrupoles for LHC (Large Hadron Collider) Luminosity Upgrades. These 3.7-m long magnets, scaled from the 1-m long Technological Quadrupoles, are used to develop our capabilities to fabricate and assemble Nb{sub 3}Sn coils and structures with lengths comparable to accelerator magnet dimensions. The long quadruples have a target gradient of 200 T/m in a 90-mm aperture. Pre-stress and support are provided by an Al-shell-based structure pre-loaded using bladders and keys. The coils were fabricated at BNL and FNAL, the shell-based structure was designed and assembled at LBNL, the test is performed at FNAL. In this paper we present the final steps of the development of the first model (LQS01), several upgrades to the test facility, the test results of witness cables, and the short sample limit.

43 PARTICLE ACCELERATORS↗

Design of a Superconducting 28 GHz Ion Source Magnet for FRIB Using a Shell-Based Support Structure

The Superconducting Magnet Program at the Lawrence Berkeley National Laboratory (LBNL) is completing the design of a 28 GHz NbTi ion source magnet for the Facility for Rare Isotope Beams (FRIB). The design parameters are based on the parameters of the ECR ion source VENUS in operation at LBNL since 2002 featuring a sextupole-in-solenoids configuration. Whereas most of the magnet components (such as conductor, magnetic design, protection scheme) remain very similar to the VENUS magnet components, the support structure of the FRIB ion source uses a different concept. A shell-based support structure using bladders and keys is implemented in the design allowing fine tuning of the sextupole preload and reversibility of the magnet assembly process. As part of the design work, conductor insulation scheme, coil fabrication processes and assembly procedures are also explored to optimize performance. Finally, we present the main features of the design emphasizing the integrated design approach used at LBNL to achieve this result.

ECR ion source magnet↗

Mechanical qualification of the support structure for MQXF, the Nb 3 Sn low-β quadrupole for the high luminosity LHC

Within the scope of the High Luminosity LHC project, the collaboration between CERN and U.S. LARP is developing new low-β quadrupoles using the Nb 3 Sn superconducting technology for the upgrade of the LHC interaction regions. The magnet support structure of the first short model was designed and two units were fabricated and tested at CERN and at LBNL. The structure provides the preload to the collars-coils subassembly by an arrangement of outer aluminum shells pre-tensioned with water-pressurized bladders. For the mechanical qualification of the structure and the assembly procedure, superconducting coils were replaced with solid aluminum “dummy coils”, the structure was preloaded at room temperature, and then cooled-down to 77 K. Mechanical behavior of the magnet structure was monitored with the use of strain gauges installed on the aluminum shells, the dummy coils and the axial preload system. As a result, this paper reports on the outcome of the assembly and the cool-down tests with dummy coils, which were performed at CERN and at LBNL, and presents the strain gauge measurements compared to the 3D finite element model predictions.

43 PARTICLE ACCELERATORS↗

Mechanical performance of short models for MQXF, the Nb3Sn low-β quadrupole for the Hi-Lumi LHC

In the framework of the Hi-Lumi LHC Project, CERN and U.S. LARP are jointly developing MQXF, a 150-mm aperture high-field Nb3Sn quadrupole for the upgrade of the inner triplet of the low-beta interaction regions. The magnet is supported by a shell-based structure, providing the preload by means of bladder-key technology and differential thermal contraction of the various components. Two short models have been produced using the same cross section currently considered for the final magnet. The structures were preliminarily tested replacing the superconducting coils with blocks of aluminum. This procedure allows for model validation and calibration, and also to set performance goals for the real magnet. Strain gauges were used to monitor the behavior of the structure during assembly, cool down and also excitation in the case of the magnets. The various structures differ for the shell partitioning strategies adopted and for the presence of thick or thin laminations. This study presents the results obtained and discusses the mechanical performance of all the short models produced up to now.

43 PARTICLE ACCELERATORS↗

Two-Layer 16 T Cos θ Dipole Design for the FCC

Here, the Future Circular Collider or FCC is a study aimed at exploring the possibility to reach 100 TeV total collision energy which would require 16 tesla dipoles. Upon the conclusion of the High Luminosity Upgrade, the US LHC Accelerator Upgrade Pro-ject in collaboration with CERN will have extensive Nb 3 Sn magnet fabrication experience. This experience includes robust Nb 3 Sn conductor and insulation scheming, 2-layer cos2θ coil fabrication, and bladder-and-key structure and assembly. By making im-provements and modification to existing technology the feasibility of a two-layer 16 tesla dipole is investigated. Preliminary designs indicate that fields up to 16.6 tesla are feasible with conductor grading while satisfying the HE-LHC and FCC specifications. Key challenges include accommodating high-aspect ratio conductor, narrow wedge design, Nb 3 Sn conductor grading, and especially quench protection of a 16 tesla device.

43 PARTICLE ACCELERATORS↗

Mechanical Utility Structure for Testing High Field Superconducting Dipole Magnets

The U.S. Magnet Development Program (MDP) collaboration is designing a utility mechanical structure for testing various high-field superconducting dipole coils. The design uses a shell-based structure concept, which allows applying preload in two steps: During a room temperature assembly and during a cool down to a cryogenic temperature. The structure is designed to accommodate various coil designs - including Nb 3 Sn Cosine Theta (CT) and Canted CT magnets as well as hybrid magnets with high temperature superconductor cables. Superconducting coils, enclosed by bolted pads to form an octagonal coil pack, will be inserted into a reusable yoke-shell subassembly and precisely preloaded during the assembly using a bladder-and-key technology. Due to a differential thermal contraction between an external aluminum shell and the magnet core, the coil preload increases during the cool down up to level required for 17-T excitation. Such a reusable structure will serve as a testing fixture supporting goals of the MDP program, decreasing cost and simplifying coil performance testing at different preload levels. We present a finite-element analysis of the structure preloading various coil designs and examine the predicted coil stress at each step of the magnet assembly and excitation.

43 PARTICLE ACCELERATORS↗

Magnetic and Mechanical Design of a 15-T Large Aperture Dipole Magnet for Cable Testing

© 2019 IEEE. A large aperture Nb 3 Sn dipole is proposed to replace the magnet assembly of EDIPO, which was irreversibly damaged in 2016. The goal is to generate a background field of 15 T at 4.2 K in a clear aperture of approximately 100×150 mm 2 and over a uniform length of 1000 mm in order to test superconducting cables for both fusion and high-energy physics applications. The magnet features a block-type coil design wound with wide Rutherford cable (two alternative coil cross sections are considered) and supported by a mechanical structure based on keys-and-bladders technology. In the end regions, the coils tilt up (flare) through a hard-way bend of the cables to provide room for the test well, following a layout already adopted in the LBNL HD2 and CERN-CEA FRESCA2 magnets. The two considered coil design alternatives aim at minimizing the mechanical stress in the coil windings. One coil pack design makes the use of two double pancake coils per pole, whereas the other alternative features three double pancakes per pole. Both design options are presented focusing on the results of numerical computations carried out with finite-element models to investigate peak stresses in the coils during room-temperature pre-loading, cool down, and powering.

Sarasola, Xabier (ORCID:0000000324306939)↗

Test Results for a Superconducting 28-GHz Ion Source Magnet for FRIB

© 2002-2011 IEEE. The superconducting ECR source magnet for the Facility for Rare Isotope Beams at Michigan State University was designed and built by the Superconducting Magnet Group at Lawrence Berkeley National Laboratory (LBNL). The 28-GHz NbTi ion source magnet features a sextupole-in-solenoids configuration, which is comparable to the VENUS ECR magnet operated at LBNL. A shell-based support structure using bladders and keys has been incorporated into the design to allow for adjustments of the preload and reversibility of the magnet assembly process. The magnet has been assembled and successfully tested to operational currents at LBNL. This paper describes the basic design of the magnet and the passive quench protection system. The test results are also presented, including the quench behavior of the magnet, the training performance, and the magnetic measurement results.

Arbelaez, Diego↗

Failure Assessments for MQXF Magnet Support Structure with a Graded Approach

The High-Luminosity Large Hadron Collider (HLLHC) upgrade requires new quadrupoles, MQXF, to replace the present LHC inner triplets. The MQXFA magnet is the first prototype that has a 150 mm aperture and uses Nb 3 Sn superconducting technology in a 4.2 m magnetic length structure. The support structure design of the MQXFA magnet is based on the bladder-and-key technology, where a relatively low pre-stress at room temperature is increased to the final preload targets during the cool-down by the differential thermal contraction of the various components. The magnet support structure components experience different load levels from pre-load to cool-down and excitation. Consequently, a few parts experience high stresses that may cause localized plastic deformations or internal fracture development. The concept presented in this paper for the failure assessment of support structures integrates nonlinear finite element analysis with detailed sub-models and fracture mechanics into an advanced engineering tool. The nonlinear FE solutions enable estimations of the structural response to the given loads, and the advanced fracture analysis with failure assessment diagram (FAD) assesses the structure safety index of results obtained from the FE model. The study describes how the MQXFA shell end segments are being optimized based on the failure analyses.

43 PARTICLE ACCELERATORS↗

Mechanical Performance of the First Two Prototype 4.5 m Long Nb$_3$Sn Low-$β$ Quadrupole Magnets for the Hi-Lumi LHC Upgrade

The U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) team is collaborating with CERN in the design and fabrication of the first 4.5 m long MQXFA magnets, a 150 mm aperture high-field Nb$_3$Sn quadrupole magnet that uses the aluminum shell-based bladder-and-key technology. The first two prototype magnets, MQXFAP1 and MQXFAP2, were assem-bled and tested while the first pre-series structure (MQXFA03) was in fabrication. This paper summarizes the mechanical perfor-mance of these prototype structures based on the comparison of measured strain gauge data with finite element model analyses from all load steps to powering. The MQXFAP1 magnet almost reached ultimate current before a short to ground was detected and the test was stopped. The MQXFAP2 magnet experienced a low training performance due to a fractured aluminum shell. MQXFAP1b was rebuilt with a new replacement coil, but an old coil limited the magnet from achieving the ultimate current. The mitigations and analyses of these prototype magnets are discussed in the context of the transition to pre-series production.

43 PARTICLE ACCELERATORS↗

Magnetic and Mechanical Analysis of a Large Aperture 15 T Cable Test Facility Dipole Magnet

The US Department of Energy (DOE) Office of Science (SC), is funding a large bore “Cable Test Facility Magnet” for testing advanced cables and inserts in high transverse field. This is a joint effort between the Office of High Energy Physics (HEP) and the Office of Fusion Energy Sciences (FES). The background field magnet for this facility is being developed at Lawrence Berkeley National Laboratory (LBNL) while the cryostat and test facility will be located and operated by Fermi National Accelerator Laboratory (FNAL). The Nb 3 Sn dipole magnet, which will provide the transverse background field, is designed to generate a field of 15 T in a 100 × 150 mm bore at 1.9 K. The conceptual design of a block-type dipole with flared ends and a structure based on key-and-bladder technology will be introduced. The results of the magnetic and mechanical analysis will be presented.

43 PARTICLE ACCELERATORS↗

Computation of the Strain Induced Critical Current Reduction in the 16 T Nb 3 Sn Test Facility Dipole

A test facility dipole is being developed at LBNL, targeting a 16 T field in a 144 mm wide aperture. The magnet uses a block design, with two double-pancake coils. In order to minimize motion under the large Lorentz forces, the coils are preloaded against a thick aluminum shell and iron yoke using bladder and key technology. It is then crucial to verify that the performance of the magnet is not degraded due to strain induced on the Nb 3 Sn conductor during assembly, cool-down and powering. The critical current of extracted strands was measured in a varying background magnetic field and as a function of the applied longitudinal strain. Finite element analysis was used to extract the strain state inside the superconducting strands during magnet assembly and operation. This strain was then compared to the measurements to evaluate potential reversible and irreversible effects on the magnet performances. Here the results suggest that the magnet can reach 16 T with sufficient margin, with no irreversible degradation in the high field region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Novel Design for Improving the Control on the Stainless-Steel Vessel Welding Process for Superconducting Magnets

Stainless steel vessels see widespread use in superconducting magnets for particle accelerator applications. Their function varies in different magnet designs: they always provide the necessary liquid helium containment, but in some cases are also used to provide azimuthal prestress and can also be welded to the magnet end plate to provide additional longitudinal stiffness. A magnet designed with the bladder and key technology does not rely on the structural role of the vessel. They are structurally supported using azimuthally prestressed aluminum shells, and the longitudinal constraint by rods. In this case, the magnet designer would generally like to minimize the interaction between the magnet and the stainless-steel vessel and to minimize the coil stress variation due to the vessel. The stress state in the vessel and in the coil is a function of the circumferential interference, defined as the vessel azimuthal length minus the magnet circumference. The vessel and the magnet azimuthal length machining tolerances are relatively large resulting in significant stress variations in the superconducting coils. Here in this paper we introduce an interference-control shim, which can significantly limit the stress variation of the coils for a given variation of the interference. The effectiveness of the interference-control shim is evaluated numerically on the MQXF, the low-β quadrupole for the High Luminosity LHC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual Structural Design and Analysis of a 20 T Hybrid Cos Dipole for Future Particle Colliders

Here, to reach high collision energy for future high-energy particle colliders, like the Future Circular Collider (FCC) or the Muon Collider, it is required to achieve high field strength of the bending dipoles. Currently, the practical limit for Nb$_{\text{3}}$ Sn technology is around 16 T and, in order to further increase the magnetic field, the superconducting magnet community is considering High Temperature Superconductors (HTS), in particular Bi-2212 and REBCO conductors. However, their relevant higher cost has led the community to consider a hybrid approach where HTS materials are used in the high field region of the coils with so-called insert coils, and Low Temperature Superconductors are involved in the lower field part ($< $ 16 T) with so-called outsert coils. This paper describes the conceptual mechanical design of a 20 T hybrid cos$\theta$ dipole configuration. The high stress levels that the structure is facing due to the high magnetic field are discussed. Moreover, it presents the results of the optimization analysis of the shell-based support structure based on the key-and-bladder technology that provides the azimuthal pre-stress during room temperature assembly and cooldown to cryogenic temperatures. The aim of this work is to present a feasible design that satisfies the stress requirements.

D'Addazio, Marika [Politecnico di Torino (Italy); ↗

Design of B2PF: A Large Aperture Nb-Ti Dipole Magnet for the Electron-Ion Collider

Here, we present the initial design of the matching dipole B2PF, a large aperture cosine-theta magnet for the Electron-Ion Collider (EIC). First we share an optimized 2D magnet cross-section based on a double-layer design with Nb-Ti Rutherford cable. This cross-section is optimized to meet the required field quality in the 120 mm coil aperture both at the nominal operating current and considering iron saturation effects during the ramp. Next, we share a first design of the 3D coil ends optimized for windability, field quality, and minimizing the conductor peak field. Based on the resulting peak field, we evaluate the short-sample margin of the design for an operating target of 6.3 T dipole field at 1.9 K. Finally, we share an initial mechanical design study which utilizes a key-and-bladder support structure capable of adjusting magnet preload.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A piecewise regression approach for determining biologically relevant hydraulic thresholds for the protection of fish at river infrastructure

Barotrauma injury can occur when fish are exposed to rapid decompression during downstream passage through river infrastructure. A piecewise regression approach was used to objectively quantify barotrauma injury thresholds in two physoclistous species (Murray cod Maccullochella peelii and silver perch Bidyanus bidyanus) following simulated infrastructure passage in barometric chambers. The probability of injuries such as swim bladder rupture; exophthalmia; and haemorrhage and emphysema in various organs increased as the ratio between the lowest exposure pressure and the acclimation pressure (ratio of pressure change RPCE/A) fell. The relationship was typically non-linear and piecewise regression was able to quantify thresholds in RPCE/A that once exceeded resulted in a substantial increase in barotrauma injury. Thresholds differed among injury types and between species but by applying a multi-species precautionary principle, the maintenance of exposure pressures at river infrastructure above 70% of acclimation pressure (RPCE/A of 0.7) should sufficiently protect downstream migrating juveniles of these two physoclistous species. These findings have important implications for determining the risk posed by current infrastructures and informing the design and operation of new ones.

barotrauma↗