Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BIFURCATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)

Purpose: To assess the accuracy, reproducibility, and computational performance of deformable image registration algorithms under development at multiple institutions on common datasets. Methods and Materials: Datasets from a lung patient (four-dimensional computed tomography [4D-CT]), a liver patient (4D-CT and magnetic resonance imaging [MRI] at exhale), and a prostate patient (repeat MRI) were obtained. Radiation oncologists localized anatomic structures for accuracy assessment. Algorithm accuracy was determined by comparing the computer-predicted displacement at each bifurcation point with the displacement computed from the oncologists' annotations. Thirty-seven academic institutions and medical device manufacturers with published evidence of active deformable image registration capabilities were invited to participate. Results: Twenty-seven groups agreed to participate; 6 did not return results. Sixteen completed the liver 4D-CT, 12 the lung 4D-CT, 3 the prostate MRI, and 3 the liver MRI-CT. The range of average absolute error for the lung 4D-CT was 0.6-1.2 mm (left-right [LR]), 0.5-1.8 mm (anterior-posterior [AP]), and 0.7-2.0 mm (superior-inferior [SI]); the liver 4D-CT was 0.8-1.5 mm (LR), 1.0-5.2 mm (AP), and 1.0-5.9 mm (SI); the liver MRI-CT was 1.1-2.6 mm (LR), 2.0-5.0 mm (AP), and 2.2-2.6 mm (SI); and the repeat prostate MRI prostate datasets was 0.5-6.2 mm (LR), 3.1-3.7 mm (AP), and 0.4-2.0 mm (SI). Conclusions: An infrastructure was developed to assess multi-institution deformable registration accuracy. The results indicate large discrepancies in reported shifts, although the majority of deformable registration algorithms performed at an accuracy equivalent to the voxel size, promising to improve treatment planning, delivery, and assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anatomic Distribution of Fluorodeoxyglucose-Avid Para-aortic Lymph Nodes in Patients With Cervical Cancer

Purpose: Conformal treatment of para-aortic lymph nodes (PAN) in cervical cancer allows dose escalation and reduces normal tissue toxicity. Currently, data documenting the precise location of involved PAN are lacking. We define the spatial distribution of this high-risk nodal volume by analyzing fluorodeoxyglucose (FDG)-avid lymph nodes (LNs) on positron emission tomography/computed tomography (PET/CT) scans in patients with cervical cancer. Methods and Materials: We identified 72 PANs on pretreatment PET/CT of 30 patients with newly diagnosed stage IB-IVA cervical cancer treated with definitive chemoradiation. LNs were classified as left-lateral para-aortic (LPA), aortocaval (AC), or right paracaval (RPC). Distances from the LN center to the closest vessel and adjacent vertebral body were calculated. Using deformable image registration, nodes were mapped to a template computed tomogram to provide a visual impression of nodal frequencies and anatomic distribution. Results: We identified 72 PET-positive para-aortic lymph nodes (37 LPA, 32 AC, 3 RPC). All RPC lymph nodes were in the inferior third of the para-aortic region. The mean distance from aorta for all lymph nodes was 8.3 mm (range, 3-17 mm), and from the inferior vena cava was 5.6 mm (range, 2-10 mm). Of the 72 lymph nodes, 60% were in the inferior third, 36% were in the middle third, and 4% were in the upper third of the para-aortic region. In all, 29 of 30 patients also had FDG-avid pelvic lymph nodes. Conclusions: A total of 96% of PET positive nodes were adjacent to the aorta; PET positive nodes to the right of the IVC were rare and were all located distally, within 3 cm of the aortic bifurcation. Our findings suggest that circumferential margins around the vessels do not accurately define the nodal region at risk. Instead, the anatomical extent of the nodal basin should be contoured on each axial image to provide optimal coverage of the para-aortic nodal compartment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Toxicity Associated With Stereotactic Body Radiation Therapy to the Central Hepatobiliary Tract

Purpose: To identify dosimetric predictors of hepatobiliary (HB) toxicity associated with stereotactic body radiation therapy (SBRT) for liver tumors. Methods and Materials: We retrospectively reviewed 96 patients treated with SBRT for primary (53%) or metastatic (47%) liver tumors between March 2006 and November 2013. The central HB tract (cHBT) was defined by a 15-mm expansion of the portal vein from the splenic confluence to the first bifurcation of left and right portal veins. Patients were censored for toxicity upon local progression or additional liver-directed therapy. HB toxicities were graded according to Common Terminology Criteria for Adverse Events version 4.0. To compare different SBRT fractionations, doses were converted to biologically effective doses (BED) by using the standard linear quadratic model α/β = 10 (BED10). Results: Median follow-up was 12.7 months after SBRT. Median BED10 was 85.5 Gy (range: 37.5-151.2). The median number of fractions was 5 (range: 1-5), with 51 patients (53.1%) receiving 5 fractions and 29 patients (30.2%) receiving 3 fractions. In total, there were 23 (24.0%) grade 2+ and 18 (18.8%) grade 3+ HB toxicities. Nondosimetric factors predictive of grade 3+ HB toxicity included cholangiocarcinoma (CCA) histology (P<.0001), primary liver tumor (P=.0087), and biliary stent (P<.0001). Dosimetric parameters most predictive of grade 3+ HB toxicity were volume receiving above BED10 of 72 Gy (V{sub BED10}72) ≥ 21 cm{sup 3} (relative risk [RR]: 11.6, P<.0001), V{sub BED10}66 ≥ 24 cm{sup 3} (RR: 10.5, P<.0001), and mean BED10 (Dmean{sub BED10}) cHBT ≥14 Gy (RR: 9.2, P<.0001), with V{sub BED10}72 and V{sub BED10}66 corresponding to V40 and V37.7 for 5 fractions and V33.8 and V32.0 for 3 fractions, respectively. V{sub BED10}72 ≥ 21 cm{sup 3}, V{sub BED10}66 ≥ 24 cm{sup 3}, and Dmean{sub BED10} cHBT ≥14 Gy were consistently predictive of grade 3+ toxicity on multivariate analysis. Conclusions: V{sub BED10}72, V{sub BED10}66, and Dmean{sub BED10} to cHBT are associated with HB toxicity. We suggest V{sub BED10}72 < 21 cm{sup 3} (5-fraction: V40 < 21 cm{sup 3}; 3-fraction: V33.8 < 21 cm{sup 3}), V{sub BED10}66 < 24 cm{sup 3} (5-fraction: V37.7 < 24 cm{sup 3}; 3-fraction: V32 < 24 cm{sup 3}) as potential dose constraints for the cHBT when clinically indicated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation Model of Microsphere Distribution for Selective Internal Radiation Therapy Agrees With Observations

Purpose: To perform a detailed analysis of microsphere distribution in biopsy material from a patient treated with {sup 90}Y-labeled resin spheres and characterize microsphere distribution in the hepatic artery tree, and to construct a novel dichotomous bifurcation model for microsphere deposits and evaluate its accuracy in simulating the observed microsphere deposits. Methods and Materials: Our virtual model consisted of arteries that successively branched into 2 new generations of arteries at 20 nodes. The artery diameter exponentially decreased from the lowest generation to the highest generation. Three variable parameters were optimized to obtain concordance between simulations and measure microsphere distributions: an artery coefficient of variation (ACV) for the diameter of all artery generations and the microsphere flow distribution at the nodes; a hepatic tree distribution volume (HDV) for the artery tree; and an artery diameter reduction (ADR) parameter. The model was tested against previously measured activity concentrations in 84 biopsies from the liver of 1 patient. In 16 of 84 biopsies, the microsphere distribution regarding cluster size and localization in the artery tree was determined via light microscopy of 30-μm sections (mean concentration, 14 microspheres/mg; distributions divided into 3 groups with mean microsphere concentrations of 4.6, 14, and 28 microspheres/mg). Results: Single spheres and small clusters were observed in terminal arterioles, whereas large clusters, up to 450 microspheres, were observed in larger arterioles. For 14 microspheres/mg, the optimized parameter values were ACV=0.35, HDV = 50 cm{sup 3}, and ADR=6 μm. For 4.6 microspheres/mg, ACV and ADR decreased to 0.26 and 0 μm, respectively, whereas HDV increased to 130 cm{sup 3}. The opposite trend was observed for 28 microspheres/mg: ACV = 0.49, HDV = 20 cm{sup 3}, and ADR = 8 μm. Conclusion: Simulations and measurements reveal that microsphere clusters are larger and more common in volumes with high microsphere concentrations and indicate that the spatial distribution of the artery tree must be considered in estimates of microsphere distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-institutional Validation Study of Commercially Available Deformable Image Registration Software for Thoracic Images

Purpose: To assess the accuracy of the commercially available deformable image registration (DIR) software for thoracic images at multiple institutions. Methods and Materials: Thoracic 4-dimensional (4D) CT images of 10 patients with esophageal or lung cancer were used. Datasets for these patients were provided by DIR-lab ( (dir-lab.com)) and included a coordinate list of anatomic landmarks (300 bronchial bifurcations) that had been manually identified. Deformable image registration was performed between the peak-inhale and -exhale images. Deformable image registration error was determined by calculating the difference at each landmark point between the displacement calculated by DIR software and that calculated by the landmark. Results: Eleven institutions participated in this study: 4 used RayStation (RaySearch Laboratories, Stockholm, Sweden), 5 used MIM Software (Cleveland, OH), and 3 used Velocity (Varian Medical Systems, Palo Alto, CA). The ranges of the average absolute registration errors over all cases were as follows: 0.48 to 1.51 mm (right-left), 0.53 to 2.86 mm (anterior-posterior), 0.85 to 4.46 mm (superior-inferior), and 1.26 to 6.20 mm (3-dimensional). For each DIR software package, the average 3-dimensional registration error (range) was as follows: RayStation, 3.28 mm (1.26-3.91 mm); MIM Software, 3.29 mm (2.17-3.61 mm); and Velocity, 5.01 mm (4.02-6.20 mm). These results demonstrate that there was moderate variation among institutions, although the DIR software was the same. Conclusions: We evaluated the commercially available DIR software using thoracic 4D-CT images from multiple centers. Our results demonstrated that DIR accuracy differed among institutions because it was dependent on both the DIR software and procedure. Our results could be helpful for establishing prospective clinical trials and for the widespread use of DIR software. In addition, for clinical care, we should try to find the optimal DIR procedure using thoracic 4D-CT data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Respiratory Motion Perturbation Model Adaptable to Patient Breathing Irregularities

Purpose: To develop a physical, adaptive motion perturbation model to predict tumor motion using feedback from dynamic measurement of breathing conditions to compensate for breathing irregularities. Methods and Materials: A novel respiratory motion perturbation (RMP) model was developed to predict tumor motion variations caused by breathing irregularities. This model contained 2 terms: the initial tumor motion trajectory, measured from 4-dimensional computed tomography (4DCT) images, and motion perturbation, calculated from breathing variations in tidal volume (TV) and breathing pattern (BP). The motion perturbation was derived from the patient-specific anatomy, tumor-specific location, and time-dependent breathing variations. Ten patients were studied, and 2 amplitude-binned 4DCT images for each patient were acquired within 2 weeks. The motion trajectories of 40 corresponding bifurcation points in both 4DCT images of each patient were obtained using deformable image registration. An in-house 4D data processing toolbox was developed to calculate the TV and BP as functions of the breathing phase. The motion was predicted from the simulation 4DCT scan to the treatment 4DCT scan, and vice versa, resulting in 800 predictions. For comparison, noncorrected motion differences and the predictions from a published 5-dimensional model were used. Results: The average motion range in the superoinferior direction was 9.4 ± 4.4 mm, the average ΔTV ranged from 10 to 248 mm{sup 3} (−26% to 61%), and the ΔBP ranged from 0 to 0.2 (−71% to 333%) between the 2 4DCT scans. The mean noncorrected motion difference was 2.0 ± 2.8 mm between 2 4DCT motion trajectories. After applying the RMP model, the mean motion difference was reduced significantly to 1.2 ± 1.8 mm (P=.0018), a 40% improvement, similar to the 1.2 ± 1.8 mm (P=.72) predicted with the 5-dimensional model. Conclusions: A novel physical RMP model was developed with an average accuracy of 1.2 ± 1.8 mm for interfraction motion prediction, similar to that of a published lung motion model. This physical RMP was analytically derived and is able to adapt to breathing irregularities. Further improvement of this RMP model is under investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

External Validation and Optimization of International Consensus Clinical Target Volumes for Adjuvant Radiation Therapy in Bladder Cancer

Purpose: International consensus (IC) clinical target volumes (CTVs) have been proposed to standardize radiation field design in the treatment of patients at high risk of locoregional failure (LRF) after radical cystectomy. The purpose of this study was to externally validate the IC CTVs in a cohort of postsurgical patients followed up for LRF and identify revisions that might improve the IC CTVs' performance. Methods and Materials: Among 334 patients with pT3 to pT4 bladder cancer treated with radical cystectomy, LRF developed in 58 (17%), of whom 52 had computed tomography scans available for review. Images with LRF were exported into a treatment planning system, and IC CTVs were contoured and evaluated for adequacy of coverage of each LRF with respect to both the patient and each of 6 pelvic subsites: common iliac (CI) region, obturator region (OR), external and internal iliac region, presacral region, cystectomy bed, or other pelvic site. Revisions to the IC contours were proposed based on the findings. Results: Of the 52 patients with documented LRF, 13 (25%) had LRFs that were outside of the IC CTV involving 17 pelvic subsites: 5 near the CI CTV, 5 near the OR CTV, 1 near the external and internal iliac region, and 6 near the cystectomy bed. The 5 CI failures were located superior to the CTV, and the 5 OR failures were located medial to the CTV. Increasing the superior boundary of the CI to a vessel-based definition of the aortic bifurcation, as well as increasing the medial extension of the OR by an additional 9 mm, decreased the number of patients with LRF outside of the IC CTV to 7 (13%). Conclusions: Modified IC CTVs inclusive of a slight adjustment superiorly for the CI region and medially for the OR may reduce the risk of pelvic failure in patients treated with adjuvant radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structure, dynamics, and redox reactivity of an all-purpose flavodoxin

The flavodoxin of Rhodopseudomonas palustris CGA009 (Rp9Fld) supplies highly reducing equivalents to crucial en- zymes such as hydrogenase, especially when the organism is iron-restricted. By acquiring those electrons from photodriven electron flow via the bifurcating electron transfer flavoprotein, Rp9Fld provides solar power to vital metabolic processes. To understand Rp9Fld’s ability to work with diverse partners, we solved its crystal structure. We observed the canonical fla- vodoxin (Fld) fold and features common to other long-chain Flds but not all the surface loops thought to recognize part- ner proteins. Moreover, some of the loops display alternative structures and dynamics. To advance studies of protein– protein associations and conformational consequences, we assigned the 19F NMR signals of all five tyrosines (Tyrs). Our electrochemical measurements show that incorporation of 3- 19 F-Tyr in place of Tyr has only a modest effect on Rp9Fld’s redox properties even though Tyrs flank the flavin on both sides. Meanwhile, the 19 F probes demonstrate the expected paramagnetic effect, with signals from nearby Tyrs becoming broadened beyond detection when the flavin semiquinone is formed. However, the temperature dependencies of chemical shifts and linewidths reveal dynamics affecting loops close to the flavin and regions that bind to partners in a variety of systems. These coincide with patterns of amino acid type conservation but not retention of specific residues, arguing against detailed specificity with respect to partners. We pro- pose that the loops surrounding the flavin adopt altered con- formations upon binding to partners and may even participate actively in electron transfer.

19F NMR↗

A spin glass state in Ba 3 TiRu 2 O 9

The magnetic properties of Ba 3 TiRu 2 O 9 , whose crystal structure is based on stacked triangular planar lattices of M 2 O 9 dimers and single MO 6 octahedra, are reported. The system is magnetically disturbed by a substantial amount of Ti/Ru chemical disorder. The Weiss temperature and effective magnetic moment were found to be –29.5 K and 1.82 μ B /f.u. respectively, and a bifurcation in the zero field cooled and field cooled magnetic susceptibility is observed below 4.7 K, suggesting that this is a compositionally-disordered spin-glass system. Finally, the material is a semiconductor with an activation energy for charge transport of approximately 0.14 eV.

36 MATERIALS SCIENCE↗

Phase field modeling of chemomechanical fracture of intercalation electrodes: Role of charging rate and dimensionality

We investigate the fracture of Li-ion battery cathodic particles using a thermodynamically consistent phase-field approach that can describe arbitrarily complex crack paths and captures the full coupling between Li-ion diffusion, stress, and fracture. Building on earlier studies that introduced the concept of electrochemical shock, we use this approach to quantify the relationships between stable or unstable crack propagation, flaw size, and C-rate for 2D disks and 3D spherical particles. We find that over an intermediate range of flaw sizes, the critical flaw size for the onset of crack propagation depends on charging rate as an approximate power-law that we derive analytically. This scaling law is quantified in 2D by exhaustive simulations and is also supported by 3D simulations. In addition, our results reveal a significant difference between 2D and 3D geometries. In 2D, cracks propagate deep inside the particle in a rectilinear manner while in 3D they propagate peripherally on the surface and bifurcate into daughter cracks, thereby limiting inward penetration and giving rise to complex crack geometries.

36 MATERIALS SCIENCE↗

Transport and mechanical property evaluation of (AgSbTe){sub 1-x}(GeTe){sub x} (x=0.80, 0.82, 0.85, 0.87, 0.90)

(AgSbTe{sub 2}){sub 1-x}(GeTe){sub x} (known collectively by the acronym of their constituent elements as TAGS-x, where x designates the mole fraction of GeTe) materials, despite being described over 40 years ago, have only recently been studied in greater detail from a fundamental standpoint. We have prepared a series of samples with composition (AgSbTe{sub 2}){sub 1-x}(GeTe){sub x} (x=0.80, 0.82, 0.85, 0.87 and 0.90). Cast ingots of the above compositions were ground and consolidated by spark plasma sintering (SPS). Sintering conditions, specifically high applied pressures of 65 MPa and slow heating rates, were identified as important variables that lead to samples with low porosity and good mechanical strength. The resulting ingots were cut for high temperature electrical, thermal transport and mechanical property evaluation. TAGS-85 was found to have the highest ZT of all samples investigated (ZT=1.36 at 700 K) as a result of its very low value of thermal conductivity. Hall effect measurements performed from 5 to 300 K found these materials to have complex multi-band transport characteristics. - Graphical Abstract: Powder X-ray diffraction of TAGS-x (x=0.80, 0.82, 0.85, 0.87 and 0.90) showing characteristic bifurcation indicative of rhombohedral structure.

36 MATERIALS SCIENCE↗

Structural and magnetic properties of the M{sub 2}Ga{sub 2}Fe{sub 2}O{sub 9} (M=In, Sc) oxides

We report on the structural and magnetic properties of In{sub 2}Ga{sub 2}Fe{sub 2}O{sub 9} and Sc{sub 2}Ga{sub 2}Fe{sub 2}O{sub 9}. X-ray diffraction measurements confirmed the presence of a single orthorhombic phase, corresponding to the expected structure for M{sub 2}Ga{sub 2}Fe{sub 2}O{sub 9} (M=In, Sc). Neutron diffraction measurements show considerable cation disorder at different lattice sites, and suggest that there is no long range magnetic ordering down to T=10 K. Temperature dependent magnetization measurements show a separation between field-cooled and zero-field-cooled curves near T{sub f}≈19 K. Below this temperature the M(H) curves also exhibit history dependent behavior. The temperature dependent ac susceptibility shows a peak in the magnetic dissipation, with the temperature of the peak varying systematically with frequency suggesting that this feature may be associated with a glassy relaxation. Zero-field specific heat measurements down to 4 K do not reveal any long range magnetic ordering of these compounds, nor is there any transition to an ordered state under the application of a 7 T field. - Graphical abstract: Temperature variation of magnetization (ZFC and FC) of M{sub 2}Ga{sub 2}Fe{sub 2}O{sub 9} (M=In, Sc) samples at 0.01 T. The magnetization has a history dependence with a bifurcation between ZFC and FC data at the freezing temperature T{sub f}=19 K. The inset shows the enlargement for both oxides for temperatures below 30 K. Highlights: ► Chemical disorder study of the M{sub 2}Ga{sub 2}Fe{sub 2}O{sub 9} (M=In, Sc) compounds. ► Our study indicates for the first time a glassy magnetic ground state of this system. ► The glassy-like-behavior is due to magnetic frustration created by the site disorder.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure and physical properties of RE{sub 2}AgGe{sub 3} (RE=Ce, Pr, Nd) compounds

We have synthesized the compounds RE{sub 2}AgGe{sub 3} (RE =Ce, Pr, Nd) by arc melting. The crystal structure obtained from single crystal and powder X-ray diffraction suggests that these compounds crystallize in the α-ThSi{sub 2} structure type. The magnetic susceptibility data of Ce{sub 2}AgGe{sub 3} follows Curie–Weiss (CW) law above 25 K without any magnetic ordering down to 2 K. The effective magnetic moment (μ{sub eff}) was calculated as 2.53 μ{sub B}/Ce and negative Curie paramagnetic temperature (θ{sub p})=−2.4 K hint weak antiferromagnetic coupling among the adjacent spins. Pr{sub 2}AgGe{sub 3} shows a complex magnetic behavior wherein the magnetic susceptibility at field cooled and zero field cooled modes bifurcates at 11.5 K with the latter undergoing a cusp like maxima, probably due to weak ferromagnetic interaction. The θ{sub p} and μ{sub eff} obtained are 4 K and 4.33 μ{sub B}/Pr, respectively. Nd{sub 2}AgGe{sub 3} undergoes multiple magnetic transitions. Temperature dependent resistivity data reveals that three compounds are metallic in nature. - Graphical abstract: The compounds Ce{sub 2}AgGe{sub 3}, Pr{sub 2}AgGe{sub 3} and Nd{sub 2}AgGe{sub 3} have been synthesized by arc melting. X-ray diffraction suggests tetragonal α-ThSi{sub 2} type structure and diverse magnetic properties exhibited in the magnetic measurements. - Highlights: • Two new compounds Ce{sub 2}AgGe{sub 3}, Nd{sub 2}AgGe{sub 3} and known Pr{sub 2}AgGe{sub 3} synthesized by arc melting. • Crystal structure of the compounds derived from X-ray diffraction. • Ce{sub 2}AgGe{sub 3} and Pr{sub 2}AgGe{sub 3} exhibit antiferromagnetic ordering. • Nd{sub 2}AgGe{sub 3} shows multiple magnetic transition with ferrimagnetic like behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pattern formation in a coupled membrane-bulk reaction-diffusion model for intracellular polarization and oscillations

Reaction-diffusion systems have been widely used to study spatio-temporal phenomena in cell biology, such as cell polarization. Coupled bulk-surface models naturally include compartmentalization of cytosolic and membrane-bound polarity molecules. Here we study the distribution of the polarity protein Cdc42 in a mass-conserved membrane-bulk model, and explore the effects of diffusion and spatial dimensionality on spatio-temporal pattern formation. We first analyze a one-dimensional (1-D) model for Cdc42 oscillations in fission yeast, consisting of two diffusion equations in the bulk domain coupled to nonlinear ODEs for binding kinetics at each end of the cell. In 1-D, our analysis reveals the existence of symmetric and asymmetric steady states, as well as anti-phase relaxation oscillations typical of slow-fast systems. We then extend our analysis to a two-dimensional (2-D) model with circular bulk geometry, for which species can either diffuse inside the cell or become bound to the membrane and undergo a nonlinear reaction-diffusion process. We also consider a nonlocal system of PDEs approximating the dynamics of the 2-D membrane-bulk model in the limit of fast bulk diffusion. In all three model variants we find that mass conservation selects perturbations of spatial modes that simply redistribute mass. In 1-D, only anti-phase oscillations between the two ends of the cell can occur, and in-phase oscillations are excluded. In higher dimensions, no radially symmetric oscillations are observed. Instead, the only instabilities are symmetry-breaking, either corresponding to stationary Turing instabilities, leading to the formation of stationary patterns, or to oscillatory Turing instabilities, leading to traveling and standing waves. Codimension-two Bogdanov—Takens bifurcations occur when the two distinct instabilities coincide, causing traveling waves to slow down and to eventually become stationary patterns. Our work clarifies the effect of geometry and dimensionality on behaviors observed in ma.ss-conserved cell polarity models.

97 MATHEMATICS AND COMPUTING↗

Analysis of integrity and microstructure of linear friction welded Waspaloy

Nickel-base superalloy, Waspaloy, was linear friction welded (LFWed) under different axial shortening conditions of 2.0, 3.4, and 4.6 mm. The tensile properties and microhardness of the weldments were investigated in the as-LFWed condition and compared with those in the post-weld heat treated (PWHTed) condition. Mechanical properties were related to microstructures following examination by optical microscopy, high resolution scanning electron microscopy, and electron backscatter diffraction (EBSD). Analyses of the EBSD results in terms of the misorientation angle distribution, which represents the stored energy, were performed. In the as-LFWed condition, the yield strength (YS) and ultimate tensile strength (UTS) increased with axial shortening due to greater expulsion of the softened interfacial material toward the periphery as flash. In contrast, with increasing axial shortening the total elongation initially remained constant and then decreased. This was also related to the expulsion of the softened interfacial material into the bifurcated flash. Extensive dissolution of the strengthening phase (γ′) in the weld area during linear friction welding (LFW) contributed to the lower YS and UTS in the as-welded condition compared to the PWHTed condition where the γ′ particles were recovered. After performing post-weld heat treatment (PWHT), the total elongation improved due to the relaxation of stored energy and grain growth in the thermomechanically affected zone (TMAZ). - Highlights: • Tensile property and microstructure in Waspaloy linear friction welds were studied. • Yield strength and ultimate tensile strength increased with axial shortening. • Elongation initially remained constant and then decreased with axial shortening. • Post-weld heat treat recovered dissolved γ′ particles and increased weld strength. • Stored energy relaxation during post-weld heat treatment improved weld elongation.

36 MATERIALS SCIENCE↗

In situ high-temperature 3D imaging of the damage evolution in a SiC nuclear fuel cladding material

Silicon carbide (SiC)-based nuclear fission fuel rod cladding has been considered as one of the possible designs for accident tolerant fuels. It is in the form of a SiC fibre reinforced SiC matrix composite tube (SiC f -SiC m ) with monolithic SiC outer and/or inner coating layers. This study focuses on the deformation and fracture processes in this material using in situ X-ray micro-computed tomography (XCT) at room temperature (RT) and 1200 °C in an inert gas environment in a C-ring compression loading configuration. Prior to testing, local properties and residual stresses were characterised using nanoindentation and Raman spectroscopy since they can impact the mechanical behaviour of the material. The 3D strain distribution, crack formation and propagation processes including the toughening mechanisms (e.g., crack deflection, micro-cracking, crack bridging and bifurcation) are investigated in the coating and underlying composites at RT and 1200 °C. There is no particular sequence which toughening mechanism occurs first – this is very different from the conventional toughening theory in ceramic-matrix composites under uniaxial tension loading. Indeed, no evidence of fibre pull-out or fibre fracture was observed in this SiC f -SiC m nuclear cladding material in the current C-ring compression configuration. The correlation between local measurements and bulk mechanical behaviour are discussed.

3D imaging↗

Improved damage tolerance of SiC-based nuclear fuel cladding with novel multi-layered SiC coating design at 1200 °C

Continuous SiC fibre reinforced SiC matrix composites (SiC f -SiC m ) with monolithic SiC outer coatings are considered as a damage-tolerant cladding design for loss of coolant accident (LOCA) conditions in light water reactors. However, monolithic SiC coatings are brittle and prone to catastrophic failure. In this study, a SiC f -SiC m cladding with a novel multi-layer SiC outer coating (11 sub-layers, ∼260 µm in total thickness) was investigated under C-ring compression at room temperature and 1200 °C in argon environment. Real-time synchrotron X-ray computed tomography (XCT) was employed to capture crack initiation and propagation processes. Compared to conventional monolithic SiC outer coatings, the multi-layer coating structure facilitated crack deflection and bifurcation enhancing its damage tolerance at both temperatures. Despite pre-existing surface cracks, claddings exhibited stable mechanical-performance at both temperatures. These initial cracks did not critically affect the failure processes as they were not aligned with the maximum stress direction. Furthermore, the microstructure, distribution of residual stresses, and local properties of individual components in the material were thoroughly characterized, and compared with open literature on conventional claddings with monolithic outer coatings. These results provide new insights into the failure mechanisms of multi-layer SiC coatings and offer guidance for the future design of accident-tolerant nuclear fuel claddings.

36 - MATERIALS SCIENCE↗