Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytical sensitivity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

932 records · Page 52

Burning velocities of R-32/O 2 /N 2 mixtures: Experimental measurements and development of a validated detailed chemical kinetic model

This work entails characterizing the flammability of the refrigerant R-32 (CH 2 F 2 ) by both experimental measurements and modeling. Burning velocities S u were measured using a constant-volume spherical-flame method for R-32/O2/N 2 mixtures with O 2 /N 2 ratios ranging from 21% (synthetic air) to 40%, pressures of (1 to 3) bar, and equivalence ratios $\phi$ of (0.8 to 1.3). Based on a critical assessment of available data, and extended by our own calculations, a detailed chemical kinetic model was developed and key reactions determined using reaction path and sensitivity analyses. Initiation and combustion were identified as distinct kinetic regimes and burning velocities were found to be controlled by two primary reactions: unimolecular decomposition of CH 2 F 2 → CHF + HF and the subsequent reaction, CHF + O 2 → CHFO + O, the latter reaction initiating the radical chain propagating and branching by producing O atoms. Sensitive rate constants in the kinetic model were critically adjusted within their uncertainties and current knowledge bounds to best fit the experimental burning velocities. We found that rate constants in the model could be adjusted to match a given experimental S u for specific conditions (O 2 loading, P, T, $\phi$). This, however, then fixes predicted burning velocities for other all conditions within (3 to 4)% if physically realistic rate parameters are maintained. Thus, the entire set of experimental data is fit, not just to particular conditions. Relative random uncertainties in the experimental Su measurements were (4 to 6)%, but assumptions made for thermal radiation lost by the burned gas in the spherical-flame experiments add an additional systematic uncertainty. Systematic differences between the limiting cases of adiabatic (no thermal radiation lost) and optically-thin (all thermal radiation lost) varied significantly with conditions and ranged from (4 to 30)% at high to low velocities, respectively, translating into uncertainties of (2 to 15)% considering the average of two limiting cases. Comparison of experimental and kinetically modeled Su values suggests that the burned gas tends towards the optically-thin limit at the lowest pressures and fuel loadings and toward the adiabatic limit at the highest pressures and loadings. We tested and found support for this conclusion with a detailed analysis as a function of all the conditions (T, P, % O 2 , $\phi$). This behavior appears to transition from optically-thin to adiabatic as the density of the initial fuel increases, which results in increased CO 2 in the burned gas and thus increased absorption of the thermal radiation (consistent with the Beer-Lambert Law). The validated detailed model based on evaluated kinetics is shown to accurately predict burning velocities for R-32 O 2 /N 2 mixtures over a wide range of conditions and provides a reliable basis for extrapolation to other conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uniformly Ordered Binary Decision Algorithm for Benchmark Experiment Correlations in Whisper Validation

When performing a validation exercise for determining the upper subcritical limit of a nuclear criticality safety application, an analyst should select and perform a statistical analysis on a population of benchmark experiments that are neutronically similar to the application. The size of this population should be sufficiently large such that the statistical analysis has a high degree of confidence that the bias plus bias uncertainty (calculational margin) has been accurately quantified. A complication arises because many benchmark experiments share common components, leading to correlations in their measured effective multiplication factors. Correlations between benchmark experiments within the population reduces its predictive power. This motivates the need for methods that consider benchmark experiment correlations and ensure adequate statistical significance of results. The Whisper code is a statistical analysis pack- age that incorporates nuclear data sensitivity coefficients from MCNP to assess benchmark experiment similarity and then performs an extreme-value analysis to estimate the bias plus bias uncertainty. The original methodology in Whisper does not consider the effect of benchmark experiment correlations when making this estimation, and this summary proposes the uniformly ordered binary decision algorithm to address this shortcoming. The original methodology in Whisper computes similarity coefficients ck for an application compared to all benchmark experiments in its library and develops weighting factors for a selected population proportional to the ck values. The methodology can be interpreted as statistically emulating a validation exercise for a particular application where the weighting factors may be viewed as the likelihood that an analyst would include a particular benchmark experiment within the population. The effective sample size of the population is the expected or mean number of benchmark experiments in the population. The uniformly ordered binary decision algorithm identifies clusters of correlated benchmark experiments within the population and then computes adjusted weighting factors based on the magnitude of the correlation coefficients within the cluster to compute a reduced effective sample size accounting for the lower information content because of correlations. Benchmark experiments within the cluster are ordered randomly with equal probability and probabilistic decisions are made as to whether a benchmark. experiment within the cluster should treated as redundant with a previous one; if two redundant benchmark experiments are included, then the conservative worst case bias plus bias uncertainty is used and the pair is counted as a single benchmark experiment in the population. Results are provided for HEU solutions in a research version of the Whisper software using benchmark experiment correlations provided by DICE, the Database for the International Criticality Safety Benchmark Evaluation Project (ICSBEP). These show that there can be a significant increase in the bias plus bias uncertainty because the effective sample size is reduced, and therefore the algorithm, needing to meet sample size requirements, expands the benchmark experiment population by accepting less similar benchmark experiments that would have otherwise not been included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Combined Nitrogen and Phosphorous Recovery via Electrochemical Technology Integration into Municipal Wastewater Treatment Plants

This project developed electroN-P, an electrochemical technology for recovering nitrogen and phosphorus as a fertilizer product from anaerobic digester centrate, targeting an advancement from TRL 4 to 6. The reactor was scaled 220× from a 250 mL batch cell to a continuous 4-channel system treating 55 L of wastewater, recovering >80% of phosphorus. Energy consumption under constant-voltage operation was lower than the embedded energy of conventional fertilizers, while constant-current operation produced a cost-competitive product with a smaller reactor footprint. TEA and LCA outcomes were highly sensitive to the magnesium source; alternative magnesium salt configurations projected reduced costs and embedded energy compared to sacrificial rods, but at the expense of significantly longer operation times. The recovered fertilizer performed comparably to diammonium phosphate and triple superphosphate in soil and plant trials. Integrating the technology into a whole-plant model reduced aeration energy by nearly 50%, lowering the levelized cost of water treatment from $0.668/m 3 to $0.648/m 3 . Results support targeting commercialization at smaller (≤1 MGD) facilities with high-strength digester streams. Further investigation into the transport and corrosion kinetics governing sacrificial anode wear is recommended to support continuous, longer-term operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust Carbon Dioxide Plume Imaging Using Joint Tomographic Inversion of Seismic Onset Time and Distributed Pressure and Temperature Measurements (Final Report)

We develop and demonstrate rapid and cost-effective methodologies for spatiotemporal tracking of CO2 plumes during geologic sequestration using joint inversion of seismic data and distributed pressure and temperature measurements. Key elements of our methodology are: (a) a computationally efficient approach to pressure and temperature propagation, (b) analysis of time lapse seismic data using a novel ‘seismic onset time’ approach to detect fluid front propagation, and (c) data assimilation and uncertainty assessment via joint inversion of pressure, temperature and time lapse seismic data, and (d) validating the numerical tomographic inversion using a CO2 injection demonstration projects, specifically data collected from the from the Petra Nova Parish Holdings CCUS project in the West Ranch Field, Texas and the Chester-16 reef CO2 injection site in Northern Michigan which is part of the DOE Midwestern Carbon Sequestration Project. The research team is led by Texas A&M University and includes Battelle as a subcontractor with support from Shell, Anadarko, Chevron and JX Nippon. A carbon dioxide (CO2) water-alternating-gas (WAG) pilot was conducted to gain insights into tertiary oil recovery potential via CO2 flood in the West Ranch Field as part of the Petra Nova project, the world’s largest post-combustion CO2 capture and utilization initiative. With a fluvial formation geology and large contrasts in permeability, this is a challenging and novel application of CO2 enhanced oil recovery (EOR). We build a predictive dynamic model of the subsurface that incorporates the multiphase and compositional data acquired during the pilot operation. The calibrated model is used for the carbon dioxide plume imaging. The study began with an initialization of the pilot sector model extracted from a calibrated full-field model. The pilot model calibration follows a two-step hierarchical workflow. First, we performed a large-scale update of the permeability distribution by integrating available bottomhole pressure and multiphase production data. In the second step, local permeability field is fine-tuned using a streamline-based method to match CO2 breakthrough times at the producers. The predictive capability of the calibrated model was verified through two blind validation tests: (1) the model showed good agreement with saturation logs acquired at two observation wells; and (2) the model reproduced the CO2 recovery as a fraction of the injected CO2. The use of seismic onset times has shown great promise for integrating near-continuous seismic surveys for updating geologic models. In this study, we analyze the impact of seismic survey frequency on the onset time approach aiming to extend the application of onset time to infrequent seismic surveys. In addition, we quantitatively examine the nonlinearity of the onset time method and compare it to the commonly used amplitude inversion method. We carry out a sensitivity analysis of seismic survey frequency based on the complete seismic survey data (over 175 surveys) of steam injection in a heavy oil reservoir (Peace River Unit) in Canada. Our results show that an adequate onset time map can be obtained from the infrequent seismic surveys by interpolation between seismic surveys as long as there is no change in the dominant underlying physics between the successive surveys. The study also shows that nonlinearity of the onset time method can be -smaller than that of the amplitude inversion method by several orders of magnitude. Application to the Brugge benchmark case shows that the onset time method obtains comparable permeability update as the traditional seismic amplitude inversion method with faster computation and improved convergence characteristics. We extend the streamline-based data integration approach to incorporate distributed temperature sensor (DTS) data using the concept of thermal tracer travel time. Then, a hierarchical workflow composed of evolutionary and streamline methods is employed to jointly history match the DTS and pressure data. Finally, CO2 saturation and streamline maps are used to visualize the CO2 plume movement during the sequestration process. The hierarchical workflow is applied to a carbon sequestration project in a carbonate reef reservoir within the Northern Niagaran Pinnacle Reef Trend in Michigan, USA. The monitoring data set consists of distributed temperature sensing (DTS) data acquired at the injection well and a monitoring well, flowing bottom-hole pressure data at the injection well, and time-lapse pressure measurements at several locations along the monitoring well. The history matching results indicate that the CO2 movement is mostly restricted to the intended zones of injection which is consistent with an independent warm-back analysis of the temperature data. In addition to employing simulation models and inverse methods for CO2 plume imaging, we also initialized a data-driven technology for detecting inter-well connectivity based on production and pressure data. Our machine-learning framework is built on the statistical recurrent unit (SRU) model and interprets well-based injection/production data into inter-well connectivity without relying on a geologic model. We test it on synthetic and field-scale CO2 EOR projects utilizing the water-alternating-gas (WAG) process. The validation of the proposed data-driven inter-well connectivity assessment is performed using synthetic data from simulation models where inter-well connectivity can be easily measured using the streamline-based flux allocation. The SRU model is shown to offer excellent prediction performance on the synthetic case. Despite significant measurement noise and frequent well shut-ins imposed in the field-scale case, the SRU model offers good prediction accuracy, the overall relative error of the phase production rates at most producers ranges from 10% to 30%. It is shown that the dominant connections identified by the data-driven method and streamline method are in close agreement. Texas A&M University, the lead organization in the project, was primarily responsible for the development of tomographic approaches for CO2 plume mapping in conjunction with distributed pressure, temperature and seismic onset time data. Battelle, as a subcontractor, was primarily responsible for the development of analytical and empirical methods for analyzing transient injection rate and pressure data from point/line sources such as injection and monitoring wells. An additional area of emphasis for Battelle was the use of machine learning for such tasks as inferring reservoir connectivity information from injection-production data, and identifying variable importance for machine learning-based proxy models developed from full-physics simulations. The two organizations also collaborated on the application of the tomographic inversion methodology for a field data set.

02 PETROLEUM↗

Evaluation of the Paratrend Multi-Analyte Sensor for Potential Utilization in Long-Duration Automated Cell Culture Monitoring

BACKGROUND: Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments. While several single-analyte sensors exist to measure culture health, a multi-analyte sensor would simplify the cell culture system. One such multi-analyte sensor, the Paratrend 7 manufactured by Diametrics Medical, consists of three optical fibers for measuring pH, dissolved carbon dioxide (pCO(2)), dissolved oxygen (pO(2)), and a thermocouple to measure temperature. The sensor bundle was designed for intra-vascular measurements in clinical settings, and can be used in bioreactors operated both on the ground and in NASA's Space Shuttle and International Space Station (ISS) experiments. METHODS: A Paratrend 7 sensor was placed at the outlet of a bioreactor inoculated with BHK-21 (baby hamster kidney) cells. The pH, pCO(2), pO(2), and temperature data were transferred continuously to an external computer. Cell culture medium, manually extracted from the bioreactor through a sampling port, was also assayed using a bench top blood gas analyzer (BGA). RESULTS: Two Paratrend 7 sensors were used over a single cell culture experiment (64 days). When compared to the manually obtained BGA samples, the sensor had good agreement for pH, pCO(2), and pO(2) with bias (and precision) 0.005(0.024), 8.0 mmHg (4.4 mmHg), and 11 mmHg (17 mmHg), respectively for the first two sensors. A third Paratrend sensor (operated for 141 days) had similar agreement (0.02+/-0.15 for pH, -4+/-8 mm Hg for pCO(2), and 24+/-18 mmHg for pO(2)). CONCLUSION: The resulting biases and precisions are com- parable to Paratrend sensor clinical results. Although the pO(2) differences may be acceptable for clinically relevant measurement ranges, the O(2) sensor in this bundle may not be reliable enough for the ranges of pO(2) in these cell culture studies without periodic calibration.

Validation Studies↗

Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement

Nuclear fission is an energy source that can provide consistent power with very low associated carbon emissions. However, management of the used nuclear fuel is an important aspect of the application of nuclear power. Recycling of useful components from used fuel is an attractive option, but this involves chemical processing of the fuel. Possible chemical separation technologies that might be used in this regard are sensitive to solution pH. Raman spectroscopy is a promising technique for monitoring the pH of solutions in real time. Classical pH probes are too fragile to be used in the harsh environments encountered in nuclear fuel processing. Raman probes are robust and can withstand these harsh environments to track pH. Coupled with chemometric analysis, the demonstration of the use of Raman spectroscopy to track and predict the pH in carboxylate-buffered systems is made possible. Utilizing this spectroscopy in conjunction with Programmable Logic Controllers mimics industrial control systems used in many modern industrial settings. This showcases a pragmatic approach toward leveraging Raman spectroscopy and chemometric model outputs as inputs for a real-time control system. The model to predict pH created by chemometrics proved to be successful in tracking pH. The optimal pH for TALSPEAK extraction of lanthanides and actinides from aqueous solution is known to proceed in a narrow pH range of around pH = 2.8 ± 0.1. This study uses Raman optical monitoring and automated control to return and maintain solution pH within this range after acid or base perturbations move the solution pH well outside this region. Root-mean-square errors show that pH changes measured using Raman spectroscopy on the batch process solution are reliably measured and used to automatically correct and maintain solution pH. Measurement of solution pH tracks favorably with electrochemical pH probe comparison measurements. As a result, the ability to showcase Raman spectroscopy paired with chemometrics analysis acts as a durable, better alternative data source compared to traditional pH probes to optimize the separation efficiency in the used nuclear fuel processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cu-, Co-, and Zn-Based Metal–Organic Framework-Derived Nanoporous Ion Emitters for Picogram Level Analysis of Actinides

Thermal ionization mass spectrometry (TIMS) is often regarded as the preferred technique for trace-level isotopic analysis of actinides owing to its high sensitivity and absence of carry-over effects. However, actinide sample utilization efficiency (SUE) is typically low (<0.05%) without the use of activators or specialized loading approaches which can yield SUEs of >5%. To this effect, we investigate a series of metal–organic framework (MOF)-based nanoporous ion emitters (nano-PIEs) that show enhanced ionization of actinides when used in TIMS loading. We study the impact of physical and chemical properties of MOFs on TIMS SUEs using two families of MOFs that can be synthesized under similar reaction conditions. The structural and chemical properties of these MOFs can be systematically modified one at a time while keeping other features the same. This allows us to strategically investigate their impact on SUEs. The first family of MOFs considered in this study is Zeolitic Imidazole Frameworks (ZIFs) which are made using 2 methyl-imidazole as an organic linker with zinc (ZIF-8) and cobalt (ZIF-67) as metal centers. Additionally, the effect of morphology was also studied using Zn-based ZIF-L with a 2-dimensional structure. The second family of MOFs was synthesized using benzene-1,3,5-tricarboxylate (BTC) with copper (Cu-BTC) and zinc (Zn-BTC) as the metal center. Among the MOFs tested, Cu-BTC showed the highest SUE with an average SUE of 0.27 ± 0.15%, followed closely by Zn-BTC (0.24 ± 0.10%), ZIF-8 (0.17 ± 0.10%), and trailed by the other MOFs. When the MOFs were pyrolyzed in N 2 before loading, an apparent increase in the SUE was observed with ZIF-8 and Cu-BTC showing average SUEs of 0.25 ± 0.08% and 0.34 ± 0.13%, respectively, with the highest measured SUE of 0.53% for pyrolyzed Cu-BTC. In conclusion, this observed increase in SUE by up to an order of magnitude compared to bare filaments demonstrates the efficacy and potential of MOF-derived nano-PIEs for TIMS application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Entangled Photon Spectroscopy

Conspectus The enhanced interest in quantum-related phenomena has provided new opportunities for chemists to push the limits of detection and analysis of chemical processes. As some have called this the second quantum revolution, a time has come to apply the rules learned from previous research in quantum phenomena toward new methods and technologies important to chemists. While there has been great interest recently in quantum information science (QIS), the quest to understand how nonclassical states of light interact with matter has been ongoing for more than two decades. Our entry into this field started around this time with the use of materials to produce nonclassical states of light. Here, the process of multiphoton absorption led to photon-number squeezed states of light, where the photon statistics are sub-Poissonian. In addition to the great interest in generating squeezed states of light, there was also interest in the formation of entangled states of light. While much of the effort is still in foundational physics, there are numerous new avenues as to how quantum entanglement can be applied to spectroscopy, imaging, and sensing. These opportunities could have a large impact on the chemical community for a broad spectrum of applications. Here, we discuss the use of entangled (or quantum) light for spectroscopy as well as applications in microscopy and interferometry. The potential benefits of the use of quantum light are discussed in detail. From the first experiments in porphyrin dendrimer systems by Dr. Dong-Ik Lee in our group to the measurements of the entangled two photon absorption cross sections of biological systems such as flavoproteins, the usefulness of entangled light for spectroscopy has been illustrated. These early measurements led the way to more advanced measurements of the unique characteristics of both entangled light and the entangled photon absorption cross-section, which provides new control knobs for manipulating excited states in molecules. The first reports of fluorescence-induced entangled processes were in organic chromophores where the entangled photon cross-section was measured. These results would later have widespread impact in applications such as entangled two-photon microscopy. From our design, construction and implementation of a quantum entangled photon excited microscope, important imaging capabilities were achieved at an unprecedented low excitation intensity of 10 7 photons/s, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. New reports have also illustrated an advantage of nonclassical light in Raman imaging as well. From a standpoint of more precise measurements, the use of entangled photons in quantum interferometry may offer new opportunities for chemistry research. Experiments that combine molecular spectroscopy and quantum interferometry, by utilizing the correlations of entangled photons in a Hong–Ou–Mandel (HOM) interferometer, have been carried out. The initial experiment showed that the HOM signal is sensitive to the presence of a resonant organic sample placed in one arm of the interferometer. In addition, parameters such as the dephasing time have been obtained with the opportunity for even more advanced phenomenology in the future.

36 MATERIALS SCIENCE↗

The Uranium-Containing and Thorium-Containing Anions Studied by Photoelectron Spectroscopy

An in-depth knowledge of actinide chemistry is fundamental to many aspects of nuclear science and technology, including the synthesis and processing of materials and the remediation of waste disposal sites. Among the actinides, the chemical bonding behaviors of actinium and thorium resemble those of the transition metals; the 5f-electrons of protactinium, uranium, neptunium, and plutonium often play important roles in their bonding; and among the still heavier elements, their bonding tends to mimic the lanthanide elements in terms of electron shielding and their f-electron contributions. Bonding that involves 5f-electrons, however, is especially important, in part because of the significance of uranium and plutonium, but also because these elements are among the few where f-electron participation in bonding is relatively common. This work focused on studying uranium-containing and thorium-containing anions in the gas phase using negative ion photoelectron spectroscopy. Since this technique directly probed valence electrons, it was uniquely positioned to address open questions regarding molecular bonding and electron configurations. A particularly important issue concerned how bonding in actinide-containing molecules was affected by modifications to their actinide atoms’ environment, i.e., due to their interaction with ligands. A closely related question was how actinide atoms’ suborbitals were qualitatively reordered and their energies quantitatively shifted as a result of their ligated environments. These were especially relevant issues in regard to uranium due to it having multiple possible oxidation states (OS) and the potential for 5f electron participation in bonding. The effects of ligands on oxidation states and 5f-orbital energies in uranium bonding was expected to be pronounced. Both ligands and excess electrons were seen as probes of actinide atoms within actinide-containing molecules. Our strategy for advancing knowledge of chemical bonding in the actinide-containing species utilized the synergy between experiments and theory, where in some cases experimental results validated theory and where in others computational results assisted in interpreting experiments. Calculations on actinide systems are terrifically challenging due to large spin-orbit interactions, relativistic effects, and just the sheer number of electrons involved. Even in the simplest species, e.g., U and U2, the most sophisticated, modern calculations carried out by the most experienced theorists often only approximate experimentally-measured values, such as electron affinities. For theory to provide confident predictions that can be used to solve real problems it needed an iterative and ultimately corrective mechanism by which its methods can develop further. Experiments can be used to identify when theory has failed; whereupon the subsequent process of using the experiment-theory interplay can be used to find the cause of the failure. Upon fixing it in one case, different test species can be proposed and studied by the experiment-theory combination to determine whether the problem has been corrected. Thus, experiments not only measure the values of molecular properties, they also provide navigational 3 beacons that keep computations off the reefs in an otherwise dark sea with few reference points. Experimental measurements in the actinide field are not only important, they are in actuality essential to computational progress. While it was not always possible to compare the theoreticallydetermined quantity of interest directly with the same experimentally-measured observable, it was usually possible to compare consequential properties that are both calculable and measurable. In the work completed here electron affinities and electronic state spacings were often sensitive consequential parameters. Reasonable agreement between measured and computational values signaled that a calculation that was very likely to be on-track. We had established collaborative relationships with five computational groups, all of which have expertise in computational actinide chemistry. Their PI’s are L. Cheng, D. Dixon, L. Gagliardi, K. Peterson, and B. Vlaisavljevich. Our close interaction with our theory partners led to us suggesting systems to them and them to us. This reciprocal interaction between our experimental and their computational results was among the most important strengths of this work and was a thread woven throughout. Even though anion photoelectron spectroscopic studies are conducted on anions, much of the information that they provide, pertains to the electronic structure of the neutral counterparts of those anions; among these are electron affinities and electronically excited state spacings. Our experimental tools included several specialized ion sources for forming the anionic species of interest, a mass spectrometer for identifying and mass-selecting them, and an anion photoelectron spectrometer for determining their electron affinities (EA) and characterizing the electronic states of the selected anions’ neutral counterparts. Anion photoelectron spectroscopy is conducted by crossing a mass-selected beam of anions with a fixed-frequency laser beam and energy-analyzing the resultant photodetached electrons. The photodetachment process is governed by the energyconserving relationship: hν = EBE + EKE, where hν is the photon’s energy, EBE is the electron binding (photodetachment transition) energy, and EKE is the electron’s kinetic energy. In our apparatus mass-selection is accomplished via time-of-flight mass spectrometry (TOF-MS), electron energy analysis is achieved with either a magnetic bottle or by velocity mapped imaging. Photodetachment of electrons from anions is implemented via either Nd:YAG or excimer lasers. The photodetachment transition energy, i.e., the EBE, between the ground vibrational and electronic state of an anion and the ground vibrational and electronic state of that anion’s neutral counterpart is the adiabatic electron affinity (EA) of that neutral molecule. Likewise, photodetachment transitions between the ground vibrational and electronic state of an anion and the various electronically-excited states of that anion’s corresponding neutral map the electronic spectrum of that neutral species, i.e., the spectral spacings in the photoelectron spectrum are a mirror image of the neutral’s electronic spectrum. It was, of course, crucial to be able to form the anionic species of interest. There, we had a particularly broad field of anion sources from which to choose. These included several variants of pulsed laser vaporization (LV), laser photoemission, infrared desorption plus photoemission, pulsed arc discharge (PACIS), electrospray ionization (ESI), and Rydberg electron transfer (RET). Each of these anion sources were readily combined with, i.e., connected to, the anion photoelectron spectroscopic portion of our apparatus as described above. Among the sources that utilize lasers, visible light for LV sources as well as IR for desorption sources are provided by Nd:YAG lasers. Ultraviolet photons are provided by both Nd:YAG and excimer lasers, whereas the excitation wavelengths for RET experiments come from two Nd:YAG-pumped dye lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flight Mechanics Modeling and Simulation of the Earth Entry System

Introduction: The Mars Sample Return (MSR) Campaign being planned by NASA and ESA has the ambitious goal to return Mars samples back to Earth. This international collaboration had developed a concept of operations that included a ESA-designed Earth Return Orbiter (ERO) and NASA-designed Capture, Containment, and Return System (CCRS). The Earth Entry System (EES), consisting of a protective aeroshell that houses the samples as well as sample containment vessels, would conduct entry, descent, and landing (EDL) on a direct Earth trajectory. The EES would enter on a spin-stabilized ballistic trajectory with the goal to passively achieve aerodynamic stability throughout all regions of flight. The EDL sequence would end with the EES impacting the soft playa soil of the Utah Test and Training Range (UTTR). As of the submission of this abstract, the MSR campaign is undergoing a re-architecture leading to a pause in EES development. However, the novel approaches developed in flight mechanics modeling and simulation can significantly benefit the greater IPPW community in the development of Earth return vehicles. This paper will present the latest state of EES flight mechanics modeling and simulation. The paper will highlight the simulation architecture developed and key lessons learned from understanding of EDL trajectory sensitivities. Modeling and Simulation: Figure 1 provides a high-level concept of operations for the approach, entry, descent, and landing (AEDL) phase of the CCRS-portion of MSR. The objective of EES flight mechanics is to model and simulate the EES trajectory from ERO separation to ground impact at UTTR. A variety of flight mechanics simulation models were utilized to model both exo-atmopsheric and atmospheric portions of flight. 42, a 6-DOF simulation developed at Goddard Space Flight Center, is utilized for propagating the attitude of EES during exo-atmospheric flight. 42 allows for a variety of spin eject mechanism scenarios to be simulated for analysis. 10 minutes prior to entry, the 42 states are handed off to the EDL sims. The prime EDL sim utilized by EES is the Program to Optimize Simulated Trajectories II (POST2), a 6-DOF sim developed at Langley Research Center, and the independent verification and validation EDL sim utilized is DSENDS, a 6-DOF sim developed at Jet Propulsion Laboratory. Figure 2 provides a visualization of the flight mechanics simulation model flow through various points in the AEDL phase. Due to the existence of a variety of sim models, the EES flight mechanics team developed processes for data hand-off. These processes included the development of a centralized coordinate frame document, utilization of a single, centralized simulation input document for all sims to reference, and hand-off files containing both the technical data to be ingested by other flight mechanics sims as well as annotations of modeling assumptions utilized to generate the data. Figure~\ref{fig:post2simarchitecture} provides an overview of the POST2 sim architecture wherein POST2 ingests numerous subsystem models and input files. The dispersed state file generated by MONTE provides the position/velocity state of the trajectory while the 42 Handoff file provides the attitude. The aerodynamics database, delivered by the EES aeroscience team, is utilized to simulate the aerodynamic forces and moments experienced during EDL. A custom atmosphere model, developed by EES atmosphere team, is utilized to simulate the anticipated atmosphere environment around the region of Earth through which the EES trajectory flys. These inputs and subsystem models can be varied depending on the AEDL flight mechanics scenario being simulated. Monte Carlo simulations are utilized to generate statistical AEDL performance metrics in the form of scorecards and violin plots. Furthermore, outputs from the POST2 simulation are utilized for follow-on analyses including aerothermal and landing performance. \section{Flight Mechanics Lessons Learned} Though the EES flight mechanics team uncovered a variety of lessons learned through the analysis conducted to support CCRS through preliminary design review, this paper will highlight the most important lessons. A key AEDL performance goal is to ensure the landing footprint of EES remains on the UTTR south range. A common modeling strategy used in EDL analysis is One-Variable-At-a-Time (OVAT). OVAT analysis provides insight into the key drivers that affect AEDL performance metrics. Figure 3 shows the landing ellipses for single dispersion sources as compared to the baseline aggregate of all dispersions. The figure shows that atmosphere winds alone dominate the size of the footprint ellipse (note: EES does not use a parachute unlike previous Earth-return missions and is in wind-driven free fall for ~5min). The significance of the wind led the EES flight mechanics team to pursue the development of a Custom Atmosphere Model [4], in lieu of EarthGRAM [1], built on actual radiosonde wind measurements around the UTTR-region. This decision was driven by the realism in the generated footprint ellipses and lessons-learned from Stardust [5]. These findings will be invaluable for future Earth-return missions in providing an early understanding of the key drivers affecting footprint size and modeling considerations for which to account. Another lesson learned is tied to the AEDL performance goal of achieving passive stability throughout all regions of flight. It is well understood that blunt-body aeroshells are less stable as they transition from supersonic to subsonic. Eliminating a backshell does help improvestability; however, other phenomena such as roll-induced instability during terminal descent can still arise. The EES flight mechanics team developed stability metrics as tools to better understand the causes of and better predict the onset of dynamic instability. These tools were built upon analytical models developed by Jaffe [3] and Murphy [2]. The tools were shown to both be very accurate in correlation with actual unstable cases and useful in developing stability margin policies based on the vehicle design and simulation considerations (e.g. sphere-cone angle change, mass change, wind turbulence). These tools allowed for the current EES design to demonstrate the ability to achieve passive stability and can be an invaluable tool for consideration in the design of parachute-less Earth-return vehicles.

Rohan Deshmukh↗

2025 ASMS Investigation of the Collision-Induced Dissociation Mechanism of Protonated TODGA with IRIS

Title (20 words): Investigation of the Collision-Induced Dissociation Mechanism of Protonated TODGA with IRIS Introduction (120 words): One of the challenges facing wide-spread adoption of nuclear power is the development of efficient separation processes for used nuclear fuel. The molecules in separation processes are subjected to an extreme environment due to the high radiation fields from the used fuel and highly acidic media used for fuel dissolution, which results in significant molecular degradation, leading to reduced process efficiency. These degradation products must be identified and studied so mitigation strategies can be developed to maintain process efficiency. However, complex systems can have many degradation products, complicating identification. Untargeted analysis tools could be used to understand radiation chemistry in complex systems. However, this would necessitate improved understanding of the gas-phase fragmentation mechanisms of fuel cycle molecules like tetraoctyldiglycolamide (TODGA). Methods (120 words): The gas-phase fragmentation of protonated TODGA was investigated using collision-induced dissociation (CID), resonance ejection, and infrared ion spectroscopy (IRIS). CID and resonance ejection experiments were conducted using a Bruker Daltonics (Bremen, Gemany) SolariX XR fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. IRIS spectra of protonated TODGA and its two CID fragmentation products were measured using a modified Bruker amaZon Speed ETD 3D quadrupole ion trap mass spectrometer coupled to the Free Electron Lasers for Infrared eXperiments (FELIX) free electron laser. Measured spectra were compared with density functional theory (DFT) calculations using the Gaussian 16, Revision C.02 software package with the ?B97X-D functional and def2-TZVPP basis sets. Candidate structures were generated using the CREST 3.0 conformational sampling software tool. Preliminary Data (300 words): Collision-induced dissociation of protonated TODGA ([C36H73N2O3]+, m/z=581.562) results two fragment ions, one at m/z=340.285 assigned as [C20H38NO3]+ and the other at m/z=312.290, assigned as [C19H38NO2]+. Based on the assigned formula and the structure of protonated TODGA, the fragment at m/z=340.285 is likely formed from elimination of neutral dioctylamine. Comparison of the IRIS spectrum of m/z=340.285 with DFT predictions suggests it contains a ring structure, and is assigned as N-octyl-N-(6-oxo-1,4-dioxan-2-ylidene)octan-1-aminium. Based on this structure and the structure of protonated TODGA, we hypothesize this fragment formed from elimination of neutral dioctylamine followed by a ring closure mechanism. Comparison of the IRIS spectrum of the fragment at m/z=312.290 with DFT predictions also indicated the presence of a ring structure, assigned as N-(1,3-dioxolan-4-ylidene)-N-octyloctan-1-aminium. This product could be formed from elimination of carbon monoxide from the ring of m/z=340.285 as a sequential fragmentation or formed directly from protonated TODGA via elimination of neutral N,N-dioctylformamide followed by a ring closure. Resonance ejection experiments where m/z=340 was continuously ejected from the IRC cell showed no decrease in intensity of m/z=312.290 across several collision energies, suggesting that the later, direct formation mechanism, dominates. The location of the ionizing proton in protonated TODGA is important for modeling the fragmentation mechanisms. DFT calculations suggested that the position of bands involving the coupled vibrations of the amide C—N and C=O bonds in TODGA are the most sensitive to proton location. Evaluation of the IRIS spectrum of protonated TODGA suggests that the ionizing proton is located between the two amid oxygens. This protonation location was calculated to lie approximately 30 kJ/mol lower in energy than the next lowest energy location, with the proton located solely on one of the amide oxygens. Novel aspect (20 words): Infrared ion spectroscopy combined with resonance ejection experiments and density functional theory to probe the collision-induced dissociation mechanism of tetraoctyldiglycolamide.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Life cycle analysis of polylactic acids from different wet waste feedstocks

Producing a valuable chemical product through diversion of wet wastes can simultaneously resolve the problems associated with increasing wastes and greenhouse gas emissions from conventional chemical production processes. In this work, we investigated the life-cycle greenhouse gas emissions, water, and fossil-fuel consumption for waste-derived polylactic acids (PLA) from three different waste feedstocks, namely wastewater sludge, food waste, and swine manure, using the Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model. The decarbonization potential of replacing fossil-based resins with the waste-derived polymer was also investigated. The results show that swine manure-to-PLA pathway was the least carbon intensive (—1.4 kgCO 2 e/kg) among the three waste-to-PLA pathways on a cradle-to-grave basis, followed by the food waste case (—1.3 kgCO 2 e/kg) and then by the wastewater sludge case (0.6 kgCO 2 e/kg). In the baseline scenario, all three waste-to-PLA pathways were less carbon intensive than both fossil-based PET and HDPE on a cradle-to-grave basis: 66% (vs. PET) and 56% (vs. HDPE), 171 and 192%, 181 and 205% reduction in GHG emissions for wastewater sludge-, food waste-, and swine manure-to-PLA pathway, respectively. For all sensitivity cases investigated, the food waste- and swine manure-to-PLA pathways were significantly less carbon intensive than their fossil-counterparts. In terms of the annual decarbonization potential of replacing fossil-based PET or HDPE, the wastewater sludge- and food waste-pathway showed higher mitigation potential than the swine manure-pathway: i) 18–28 kilotons CO 2 e-reduction per year for wastewater sludge pathway; ii) 23–26 kTCO 2 e-reduction/yr for food waste pathway; and iii) about 5 kTCO 2 e-reduction/yr for swine manure pathway depending on the type of conventional resin replaced. However, given the abundant availability of the swine manure feedstocks across the United States, the decarbonization potential of swine manure-based pathway can also increase as the plant capacity or the number of plants grow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Qualitative Headspace GCMS Analysis of Lunar Regolith and Volatile Simulant Mixtures

Introduction: Future Artemis missions aim to return the volatile-bearing samples collected near lunar polar craters. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving the integrity of returned samples and the science value those samples contain. The extent to which that preservation is possible, and the trade-offs preservation requires (e.g. monetary costs, sample volume limitations) all must be considered. Even less-than pristine volatile-bearing samples will be of tremendous value to the scientific community seeking to unravel the history of lunar surface volatiles and, more broadly, volatiles in the solar system. A sample collected on the lunar surface will experience at least five distinctive periods during which any changes here referred to as “alteration” will certainly occur at some scale: collection on the lunar surface; transportation back to Earth; long-term storage; curatorial processing; and allocation/distribution. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on returned volatile samples by working with high-fidelity volatile-containing regolith simulants, setting the foundation for the future of cold curation. This abstract is focused on gas-surface interactions between LCROSS volatiles and readily available lunar regolith simulants. Experiments involved analyzing differences in headspace gas composition for various combinations of volatile and regolith simulants using gas chromatography/mass spectrometry (GC/MS). Experimental Procedure: The volatile simulants were chosen based on the molecules detected during the LCROSS mission.1 Stock solutions of condensed lunar volatile analytes were: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. The regolith simulants used were primarily JSC-1A and NU-LHT-4M. Additional regolith simulant control studies were conducted with <150 μm sieved sand and KBr. A nested vial sample preparation approach separated the liquid stock solutions from the regolith, eliminating potential matrix effects between liquid and solid phases. Fifteen microliter aliquots of liquid volatile simulants were added to a 2 mL liquid GC vial and capped in atmosphere. An 18G needle punctured the 2 mL GC vial immediately before being transferred and sealed in a 20 mL GC vial containing 0-0.3 g of regolith simulant, see Figure 1. Separating the analytes ensures any changes observed in the total headspace gases is a result of gas-surface and/or gas-gas interactions. Equipment and Method: Initial GC/MS method development for the separation and identification of relevant headspace gases can be found in Amick, et al. 2023.2 The only hardware change is a different column: a TG-1701MS 30 m × 0.25 mm × 1.00 μm column. The vials were sampled at 10°C, room temperature (~25°C) and 50°C. Low temperature samples were kept in a chilled autosampler stage for at least 1 hour prior to sampling. High temperature samples were agitated at 50°C for 5 minutes immediately prior to injection onto the column. Headspace chromatograms were collected for each combination of temperature, regolith, and volatile simulant, including controls without one or both types of analytes, in triplicate. The chromatogram elution window for each analyte or significant atmospheric gas was identified using the peak mass spectrum cross-referenced with Figure 1.Picture of the nested vial set-up. a NIST MS library search. Each analyte peak was integrated after filtering the mass spectrum trace for the parent or most unique mass-to-charge ratio. For example, the mass-to-charge ratio used to identify, filter for, and integrate the carbon dioxide peak was centered around 44 m/z. Results: Figure 2 shows the integrated peak area for hydrogen sulfide in all combinations of regolith simulants, temperatures, and the addition of ammonia in methanol solution. Multiple repeat experiments with H2S and regolith simulants have confirmed hydrogen sulfide is removed from the headspace within 1 hour when exposed to JSC-1A, NU-LHT-4M and sand (not pictured). The consumption of H2S by lunar regolith simulants at different temperatures indicates surface chemistry will be an integral component in sample integrity and preservation. It is important to note that while the effect of surface chemistry on gaseous hydrogen sulfide is intriguing, further investigation into more chemically accurate regolith simulants is necessary and ongoing. The sulfur in hydrogen sulfide is in its most reduced state while off-the-shelf, terrestrially sourced JSC-1A and NU-LHT-4M are more oxidized than most lunar materials,3which likely leads to different oxidation-reduction reactions than would be expected in lunar regolith. Figure 3 shows the integrated peak area of carbon dioxide for each sample combination that contained ammonia in methanol solution. The addition of ammonia to the GC vials results in a consistent and reproducible decrease in carbon dioxide gas, even at 50°C. The effect became more pronounced when JSC-1A or NU-LHT-4M were present. This set of experiments demonstrated that the sample composition will affect the chemical and physical state of each component present. Future spectroscopic and microscopy experiments will be geared towards identifying the cause for the CO2(g) concentration decrease and the consumption of hydrogen sulfide. As cold and volatile curation scientists, this information provides necessary insight on how to appropriately handle and analyze volatile bearing returned samples, as well as predict the effect chemical composition has on the various sample phases we will analyze upon return to Earth. Unlike traditional curation of geologic materials, the molecules in a sample cannot be identified or processed using the naked eye or even an optical microscope. Volatile curation will require a combination of analytical techniques, including but not limited to highly sensitive gas and solid/condensed phase spectroscopy. This set of experiments has demonstrated the need for more detailed studies of volatile mixtures with mineralogically and geochemically analogous lunar regolith simulants to prepare for the curation of volatile-rich lunar samples from the south polar region of the Moon. References: [1] Colaprete, A., et al. (2010) Science, 330, (463-468). [2] Amick, C. L., et al.(2023) Houston, Texas, [3] Heiken, G. H., et al.(1991) (778-778)

Cecilia L Amick↗