Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AMPLIFIER DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Zero-crossing detector with sub-microsecond jitter and crosstalk

A zero-crossing detector (ZCD) was built and tested with a new circuit design which gives reduced time jitter compared to previous designs. With the new design, time jitter is reduced for the first time to a value which approaches that due to noise in the input amplifying stage. Additionally, with fiber-optic transmission of the output signal, crosstalk between units has been eliminated. The measured values are in good agreement with circuit noise calculations and approximately ten times lower than that for ZCD's presently installed in the JPL test facility. Crosstalk between adjacent units was reduced even more than the jitter.

Dick, G. John↗

Improved Zero-Crossing Detector

Improved zero-crossing-detector circuit designed for precisely measuring difference between frequencies of two frequency-standard signal sources. Contains low-bandwidth first-stage amplifier and three limiting amplifiers, each "squares" signal bit more. Crosstalk eliminated and jitter reduced to about 10 to the negative 7th power microseconds.

Dick, G. John↗

Solid state lasers for planetary exploration

Design and performance data for two laser transmitters for spaceborne laser ranging are presented. The first laser uses a master oscillator/power amplifier configuration consisting of a diode pumped Nd:YAG slab ring and a multipass diode pumped slab amplifier which can operate at 40 Hz for more than ten to the ninth shots. The other laser is a diode pumped Nd:YAG slab standing wave oscillator which operates at 10 Hz for more than 0.6 x 10 exp 9 shots. The lasers were specifically developed for reliability, for use in space exploitation of the Earth and nearby planets. Applications include planetary altimetry of Mars (MOLA) and Earth (GLRS), as well as space geodesy, navigation, and tracking.

Greene, Ben↗

System Measures Pressures Aboard A Compressor Rotor

Rotating pressure-measuring instrumentation includes on-board calibration standard. Computer-controlled, multichannel instrumentation system acquires pressure measurements from sensors mounted in 1.52-m-diameter rotor of compressor. Includes 5 miniature, electronically scanned pressure (ESP) modules, each containing 48 piezoresistive pressure sensors, pneumatic calibration valve, and electronic circuits for addressing and amplifying output of each sensor. Modules mounted on centerline of rotor, on instrumentation tower located inside nose cone of rotor. Subsystem designed to convert analog signal to distinct frequency without significantly affecting accuracy.

Freedman, Robert J.↗

A Simulated Annealing Algorithm for the Optimization of Multistage Depressed Collector Efficiency

The microwave traveling wave tube amplifier (TWTA) is widely used as a high-power transmitting source for space and airborne communications. One critical factor in designing a TWTA is the overall efficiency. However, overall efficiency is highly dependent upon collector efficiency; so collector design is critical to the performance of a TWTA. Therefore, NASA Glenn Research Center has developed an optimization algorithm based on Simulated Annealing to quickly design highly efficient multi-stage depressed collectors (MDC).

Vaden, Karl R.↗

Metabolic characterization of anaerobic fungi provides a path forward for bioprocessing of crude lignocellulose

The conversion of lignocellulose-rich biomass to bio-based chemicals and higher order fuels remains a grand challenge, as single-microbe approaches often cannot drive both deconstruction and chemical production steps. In contrast, consortia based bioprocessing leverages the strengths of different microbes to distribute metabolic loads and achieve process synergy, product diversity, and bolster yields. Here, we describe a biphasic fermentation scheme that combines the lignocellulolytic action of anaerobic fungi isolated from large herbivores with domesticated microbes for bioproduction. When grown in batch culture, anaerobic fungi release excess sugars from both cellulose and crude biomass due to a wealth of highly expressed carbohydrate active enzymes (CAZymes), converting as much as 49% of cellulose to free glucose. This sugar-rich hydrolysate readily supports growth of Saccharomyces cerevisiae, which can be engineered to produce a range of value-added chemicals. Further, construction of metabolic pathways from transcriptomic data reveals that anaerobic fungi do not catabolize all sugars that their enzymes hydrolyze from biomass, leaving other carbohydrates such as galactose, arabinose, and mannose available as nutritional links to other microbes in their consortium. Although basal expression of CAZymes in anaerobic fungi is high, it is drastically amplified by cellobiose breakout products encountered during biomass hydrolysis. Overall, these results suggest that anaerobic fungi provide a nutritional benefit to the rumen microbiome, which can be harnessed to design synthetic microbial communities that compartmentalize biomass degradation and bioproduct formation.

Environmental Molecular Sciences Laboratory↗

MMIC Replacement for Gunn Diode Oscillators

An all-solid-state replacement for high-frequency Gunn diode oscillators (GDOs) has been proposed for use in NASA s millimeter- and submillimeter-wave sensing instruments. Highly developed microwave oscillators are used to achieve a low-noise and highly stable reference signal in the 10-40-GHz band. Compact amplifiers and high-power frequency multipliers extend the signal to the 100-500-GHz band with minimal added phase noise and output power sufficient for NASA missions. This technology can achieve improved output power and frequency agility, while maintaining phase noise and stability comparable to other GDOs. Additional developments of the technology include: a frequency quadrupler to 145 GHz with 18 percent efficiency and 15 percent fixed tuned bandwidth; frequency doublers featuring 124, 240, and 480 GHz; an integrated 874-GHz subharmonic mixer with a mixer noise temperature of 3,000 K DSB (double sideband) and mixer conversion loss of 11.8 dB DSB; a high-efficiency frequency tripler design with peak output power of 23 mW and 14 mW, and efficiency of 16 and 13 percent, respectively; millimeter-wave integrated circuit (MMIC) power amplifiers to the 30-40 GHz band with high DC power efficiency; and an 874-GHz radiometer suitable for airborne observation with state-of-the-art sensitivity at room temperature and less than 5 W of total power consumption.

Crowe, Thomas W.↗

Multiplexed Oversampling Digitizer in 65 nm CMOS for Column-Parallel CCD Readout

A digitizer designed to read out column-parallel charge-coupled devices (CCDs) used for high-speed X-ray imaging is presented. The digitizer is included as part of the High-Speed Image Preprocessor with Oversampling (HIPPO) integrated circuit. The digitizer module comprises a multiplexed, oversampling, 12-bit, 80 MS/s pipelined Analog-to-Digital Converter (ADC) and a bank of four fast-settling sample-and-hold amplifiers to instrument four analog channels. The ADC multiplexes and oversamples to reduce its area to allow integration that is pitch-matched to the columns of the CCD. Novel design techniques are used to enable oversampling and multiplexing with a reduced power penalty. The ADC exhibits 188 ?V-rms noise which is less than 1 LSB at a 12-bit level. The prototype is implemented in a commercially available 65 nm CMOS process. The digitizer will lead to a proof-of-principle 2D 10 Gigapixel/s X-ray detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stabilization of the potential multi-steady-state absolute instabilities in a gyrotron traveling-wave amplifier

The problem of spurious oscillations induced by absolute instabilities is the most challenging one that hinders the development of the millimeter-wave gyrotron traveling-wave amplifiers (gyro-TWTs). A spurious oscillation exists as a high order axial mode (HOAM) in the interaction circuit. This paper is devoted to demonstrating the complicated steady states of these HOAMs and exploring corresponding techniques to stabilize these potential multi-steady-state absolute instabilities. The stability-oriented design principle is conveyed in a start-to-end design flow of a Ka-band TE{sub 11} mode gyro-TWT. Strong magnetic tapering near the downstream port, which is capable of cutting short the effective interaction circuit of a spurious oscillation and simultaneously boosting the amplification performance, is for the first time proposed to further improve the system stability. It is also found that an ideal prebunched electron beam in the linear stage is the necessary condition to efficient amplification in the nonlinear stage, suggesting that it is feasible to design a stable prebunching stage to replace the distributed-loss-loaded linear stage. The stability-oriented design principle provides more explicit reference for future design of a zero-drive stable gyro-TWT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WE-EF-210-07: Development of a Minimally Invasive Photo Acoustic Imaging System for Early Prostate Cancer Detection

Purpose: The objective of this work is to design, implement and characterize a catheter-based ultrasound/photoacoustic imaging probe for early-diagnosis of prostate cancer and to aid in image-guided radiation therapy. Methods: The need to image across 6–10cm of tissue to image the whole prostate gland limits the resolution achievable with a transrectal ultrasound approach. In contrast, the urethra bisects the prostate gland, providing a minimally invasive pathway for deploying a high resolution ultrasound transducer. Utilizing a high-frequency (20MHz) ultrasound/photoacoustic probe, high-resolution structural and molecular imaging of the prostate tissue is possible. A custom 3D printed probe containing a high-frequency single-element ultrasound transducer is utilized. The diameter of the probe is designed to fit inside a Foley catheter and the probe is rotated around the central axis to achieve a circular B-scan. A custom ultrasound amplifier and receiver was set up to trigger the ultrasound pulse transmission and record the reflected signal. The reconstructed images were compared to images generated by traditional 5 MHz ultrasound transducers. Results: The preliminary results using the high-frequency ultrasound probe show that it is possible to resolve finely detailed information in a prostate tissue phantom that was not achievable with previous low-frequency ultrasound systems. Preliminary ultrasound imaging was performed on tissue mimicking phantom and sensitivity and signal-to-noise ratio of the catheter was measured. Conclusion: In order to achieve non-invasive, high-resolution, structural and molecular imaging for early-diagnosis and image-guided radiation therapy of the prostate tissue, a transurethral catheter was designed. Structural/molecular imaging using ultrasound/photoacoustic of the prostate tissue will allow for localization of hyper vascularized areas for early-stage prostate cancer diagnosis.

60 APPLIED LIFE SCIENCES↗

Anatomy of an transparent optical circulator.

An optical circulator is a multi-port, nonreciprocal device that routes light from one specific port to another. Optical circulators have at least 3 or 4 ports, up to 6 port possible (JDS Uniphase, Huihong Fiber) Circulators do not disregard backward propagating light, but direct it to another port. Optical circulators are commonly found in bi-directional transmission systems, WDM networks, fiber amplifiers, and optical time domain reflectometers (OTDRs). 3-Port optical circulators are commonly used in PDV systems. 1550 nm laser light is launched into Port 1 and will exit out of Port 2 to the target. Doppler-shifted light off the moving surface is reflected back into Port 2 and exits out of Port 3. Surprisingly, a circulator requires a large number of parts to operate efficiently. Transparent circulators offer higher isolation than those of the reflective style using PBSs. A lower PMD is obtained using birefringent crystals rather than PBSs due to the similar path lengths between e and o rays. Many various circulator designs exist, but all achieve the same non-reciprocal results.

99 GENERAL AND MISCELLANEOUS↗

Linear and nonlinear theories of a large-orbit gyrotron traveling wave amplifier

The linear and nonlinear theories of large-orbit gyrotron traveling wave amplifiers (gyro-TWAs) have been developed based on the corresponding theories of small-orbit gyro-TWAs. The linear theory is in good agreement with the nonlinear theory in the small signal region of large-orbit gyro-TWAs. The phenomenon that most electrons move toward the axis of interaction circuit during the beam-wave interaction is observed and its potential effect on the design of large-orbit coaxial gyro-TWAs is emphasized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a switched integrator amplifier for high-accuracy optical measurements

In the field of low flux optical measurements, the development and use of large area silicon detectors is becoming more frequent. The current/voltage conversion of their photocurrent presents a set of problems for traditional transimpedance amplifiers. The switched integration principle overcomes these limitations. We describe the development of a fully characterized current-voltage amplifier using the switched integrator technique. Two distinct systems have been developed in parallel at the United Kingdom's National Physical Laboratory (NPL) and Czech Metrology Institute (CMI) laboratories. We present the circuit theory and best practice in the design and construction of switched integrators. In conclusion the results achieved and future developments are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First On-Wafer Power Characterization of MMIC Amplifiers at Sub-Millimeter Wave Frequencies

Recent developments in semiconductor technology have enabled advanced submillimeter wave (300 GHz) transistors and circuits. These new high speed components have required new test methods to be developed for characterizing performance, and to provide data for device modeling to improve designs. Current efforts in progressing high frequency testing have resulted in on-wafer-parameter measurements up to approximately 340 GHz and swept frequency vector network analyzer waveguide measurements to 508 GHz. On-wafer noise figure measurements in the 270-340 GHz band have been demonstrated. In this letter we report on on-wafer power measurements at 330 GHz of a three stage amplifier that resulted in a maximum measured output power of 1.78mW and maximum gain of 7.1 dB. The method utilized demonstrates the extension of traditional power measurement techniques to submillimeter wave frequencies, and is suitable for automated testing without packaging for production screening of submillimeter wave circuits.

monolithic microwave integrated circircuit↗

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

TWT design requirements for 30/20 GHz digital communications' satellite

The rapid growth of communication traffic (voice, data, and video) requires the development of additional frequency bands before the 1990's. The frequencies currently in use for satellite communications at 6/4 GHz are crowded and demands for 14/12 GHz systems are increasing. Projections are that these bands will be filled to capacity by the late 1980's. The next higher frequency band allocated for satellite communications is at 30/20 GHz. For interrelated reasons of efficiency, power level, and system reliability criteria, a candidate for the downlink amplifier in a 30/20 GHz communications' satellite is a dual mode traveling wave tube (TWT) equipped with a highly efficient depressed collector. A summary is given of the analyses which determine the TWT design requirements. The overall efficiency of such a tube is then inferred from a parametric study and from experimental data on multistaged depressed collectors. The expected TWT efficiency at 4 dB below output saturation is 24 percent in the high mode and 22 percent in the low mode.

Stankiewicz, N.↗

A Flow-Through Ultrasonic Lysis System for the Disruption of Bacterial Spores

An automated, flow-through spore lysis instrument that is capable of rapidly disrupting bacterial spores is described. The system utilizes a flow-through chamber that allows for direct injection of the sample without the need for a chemical or enzymatic pre-treatment step to soften the spore coat prior to lysis. Lysis of Bacillus subtilis spores, a benign simulant of Bacillus anthracis, is achieved by flowing the sample through a tube whose axis is parallel to the faces of two transducers that deliver 10 W cm-2 to the surface of the tube at 1.4 MHz frequency. Increases in amplifiable DNA were assessed by real-time PCR analysis, which showed at least a 25-fold increase in amplifiable DNA following ultrasonic treatment, and dilution-to-extinction PCR, which suggests up to a 100-1000-fold increase. The modular design of the ultrasonic system and integrated fluidics allow it to be incorporated into multi-step sample treatment and detection systems.

59 BASIC BIOLOGICAL SCIENCES↗

Formation of a laminar electron flow for 300 GHz high-power pulsed gyrotron

This paper describes the design of a triode magnetron injection gun for use in a 200 kW, 300 GHz gyrotron. As power and frequency increase, the performance of the gyrotron becomes quite sensitive to the quality of the electron beam. Formation of a laminar electron flow is essential for the realization of a high quality beam with a small velocity spread. In this study, a new method is developed for a quantitative evaluation of the laminarity and is applied to optimize the electrode design. The laminarity depends not only on conventional design parameters such as the cathode slant angle but also on the spatial distribution of the electric field along the beam trajectory. In the optimized design, the velocity pitch factors, {alpha}, larger than 1.2 are obtained at 65 kV, 10 A with spreads, {Delta}{alpha}, less than 5%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗