Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ADAPTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Boosting efficiency and reducing graph reliance: Basis adaptation integration in Bayesian multi-fidelity networks

The computational cost of high-fidelity numerical models makes outer-loop analysis, which requires repeated interrogation of the model such as uncertainty quantification, computationally demanding. Multi-fidelity methods, which construct a surrogate model using data from an ensemble of models of varying cost and accuracy, can substantially reduce the cost of outer-loop analysis. However, these methods can be difficult to apply when the model ensemble does not admit a clear hierarchy a priori and the correlations between models are low. Consequently, in this paper, we present a multi-fidelity method that leverages dimension reduction to enhance the correlation between models, thereby reducing the amount of data needed to train a surrogate from an unordered ensemble of models. Our method utilizes basis adaptation to build low-dimensional polynomial chaos expansions of each model and employs Multi-fidelity Networks to encode the relationships among models. We show that the resulting method exhibit two notable advantages over its counterpart: (1) enhanced accuracy (both reduced bias and variance); and (2) reduced dependency on the graph structure encoding relationships among models. We demonstrate the approach on an analytical test problem and a challenging finite element model for a spent nuclear fuel. Our method produces a surrogate model that is significantly more accurate than either a single-fidelity surrogate or a multi-fidelity surrogate constructed without basis adaptation.

42 ENGINEERING↗

Adaptive mesh refinement for steady flows in Nek5000

Adaptive mesh refinement is performed in the framework of the spectral element method augmented by approaches to error estimation and control. The h-refinement technique is used for adapting the mesh, where selected grid elements are split by a quadtree (2D) or octree (3D) structure. Continuity between parent-child elements is enforced by high-order interpolation of the solution across the common faces. Parallel mesh partitioning and grid management respectively, are taken care of by the external libraries ParMETIS and p4est. Two methods are considered for estimating and controlling the error of the solution. The first error estimate is local and based on the spectral properties of the solution on each element. This method gives a local measure of the L-2-norm of the solution over the entire computational domain. The second error estimate uses the dual-weighted residuals method - it is based on and takes into account both the local properties of the solution and the global dependence of the error in the solution via an adjoint problem. The objective of this second approach is to optimize the computation of a given functional of physical interest. The simulations are performed by using the code Nek5000 and three steady-state test cases are studied: a two-dimensional lid-driven cavity at Re = 7, 500, a two-dimensional flow past a cylinder at Re = 40, and a three-dimensional lid-driven cavity at Re = 2,000 with a moving lid tilted by an angle of 30 degrees. Finally, the efficiency of both error estimators is compared in terms of refinement patterns and accuracy on the functional of interest. In the case of the adjoint error estimators, the trend on the error of the functional is shown to be correctly represented up to a multiplicative constant.

42 ENGINEERING↗

DFT-FE – A massively parallel adaptive finite-element code for large-scale density functional theory calculations

We present an accurate, efficient and massively parallel finite-element code, DFT-FE, for large-scale ab-initio calculations (reaching ~100,000 electrons) using Kohn-Sham density functional theory (DFT). DFT-FE is based on a local real-space variational formulation of the Kohn-Sham DFT energy functional that is discretized using a higher-order adaptive spectral finite-element (FE) basis, and treats pseudopotential and all-electron calculations in the same framework, while accommodating non-periodic, semi-periodic and periodic boundary conditions. We discuss the main aspects of the code, which include, the various strategies of adaptive FE basis generation, and the different approaches employed in the numerical implementation of the solution of the discrete Kohn-Sham problem that are focused on significantly reducing the floating point operations, communication costs and latency. We demonstrate the accuracy of DFT-FE by comparing the energies, ionic forces and periodic cell stresses on a wide range of problems with popularly used DFT codes. Further, we demonstrate that DFT-FE significantly outperforms widely used plane-wave codes---both in CPU-times and wall-times, and on both non-periodic and periodic systems---at systems sizes beyond a few thousand electrons, with over 5-10 fold speedups in systems with more than 10,000 electrons. In conclusion, the benchmark studies also highlight the excellent parallel scalability of DFT-FE, with strong scaling demonstrated on up to 192,000 MPI tasks.

97 MATHEMATICS AND COMPUTING↗

Adaptation of EVIAVE methodology for monitoring and follow-up when evaluating the environmental impact of landfills

Treatment and final disposal of Municipal Solid Waste can have a significant role in the generation of negative environmental impacts. As a prevention strategy, such activities are subjected to the process of Environmental Impact Assessment (EIA). Still, the follow-up of Environmental Management Plans or mitigation measures is limited, for one due to a lack of methodological approaches. In searching for possibilities, the University of Granada (Spain) developed a diagnostic methodology named EVIAVE, which allows one to quantify, by means of indexes, the environmental impact of landfills in view of their location and the conditions of exploitation. EVIAVE is applicable within the legal framework of the European Union and can be adapted to the environmental and legal conditions of other countries. This study entails its adaptation in Colombia, for the follow-up and control of the EIA process for landfills. Modifications involved inclusion of the environmental elements flora and fauna, and the evaluation of the environmental descriptors in agreement with the concept of vulnerability. The application of the modified EVIAVE in Colombian landfills allowed us to identify the elements affected by the operating conditions and maintenance. It may be concluded that this methodology is viable and effective for the follow-up and environmental control of EIA processes for landfills, and to analyze the associated risks, as it takes into account related environmental threats and vulnerabilities. - Highlights: • A modified methodology is used to monitor and follow-up environmental impacts in landfills. • The improved methodology includes the Vulnerability of Flora and Fauna to evaluate environmental impact of landfills. • The methodology serves to identify and evaluate the sources of risk generated in the construction and siting of landfills. • Environmental vulnerability indicators improve effectiveness of the control and follow-up phases of landfill management. • The follow-up of environmental management plans may help diminish the implementation gap in Environmental Impact Assessment.

54 ENVIRONMENTAL SCIENCES↗

Off-policy deep reinforcement learning with automatic entropy adjustment for adaptive online grid emergency control

Electric overloading conditions and contingencies put modern power systems at risk of voltage collapse and blackouts. Load shedding is crucial to maintain voltage stability for grid emergency control. However, the rule- or model-based schemes rely on accurate dynamic system models and face considerable challenges in adapting to various operating conditions and uncertain event occurrences. Here, to address these issues, this paper proposes a novel deep reinforcement learning (DRL)-based voltage stability control algorithm with automatic entropy adjustment (AEA) for grid emergency control. Various dynamic network components for complex system operations are modeled to construct the DRL environment. An off-policy soft actor-critic architecture is developed to maximize the expected reward and policy entropy simultaneously. The AEA mechanism is proposed to facilitate the policy maximum entropy procedure, and the proposed method can automatically provide effective discrete and continuous actions against various fault scenarios. Our approach accomplishes high sampling efficiency, scalability, and auto-adaptivity of the control policies under high uncertainties. Comparative studies with the existing DRL-based control methods in IEEE benchmarks indicate salient performance improvement of the proposed method for dynamic system emergency control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Interface-PINNs (AdaI-PINNs) for transient diffusion: Applications to forward and inverse problems in heterogeneous media

We model transient diffusion in heterogeneous materials using a novel physics-informed neural networks framework (PINNs) termed Adaptive interface physics-informed neural networks or AdaI-PINNs (Roy et al. arXiv preprint arXiv:2406.04626, 2024). AdaI-PINNs utilize different activation functions with trainable slopes tailored to each material region within the computational domain, allowing for a fully automated and adaptive PINNs approach to model interface problems with strongly and weakly discontinuous solutions. To enhance its performance in highly heterogeneous transient diffusion systems, we prescribe a suite of robust practices, including appropriate non-dimensionalization of equations, a biased sampling method, Glorot initialization, and the hard enforcement of boundary and initial conditions. Here we evaluate the efficacy of the proposed method on several benchmark forward and inverse problems. Comparative studies on one-dimensional and two-dimensional benchmark problems reveal that the modified AdaI-PINNs outperform its unmodified counterpart, achieving root-mean-square errors that are at least two orders of magnitude better in forward problems. For inverse problems, the maximum errors in the approximated diffusion coefficients by modified AdaI-PINNs are four orders of magnitude better than those of the unmodified version. Additionally, modified AdaI-PINNs demonstrate improved stability in problems with large material mismatches.

42 ENGINEERING↗

Adaptive Interface-PINNs (AdaI-PINNs) for inverse problems: Determining material properties for heterogeneous systems

Here, we determine spatially varying discontinuous material properties using a domain-decomposition based physics-informed neural networks (PINNs) framework named the Adaptive Interface-PINNs or AdaI-PINNs (Roy et al., 2024). We propose the use of distinct neural networks for the field variables and material properties within each material, utilizing adaptive activation functions. While the neural networks across different materials share the same weights and biases, their activation functions are uniquely tailored using a hyperparameter that influences the slope of the activation function. The proposed framework is tested on several one-dimensional and two-dimensional benchmark examples, and its performance is compared with conventional PINNs and existing domain-decomposition PINNs frameworks, namely, the Multi-domain physics-informed neural network (M-PINN), and the eXtended physics-informed neural networks (XPINNs). The results demonstrate that the proposed approach can determine randomly distributed discontinuous material properties with an L 2 error of $\mathscr{O}$ (10 -3 ) for the material property and the root-mean-square error of $\mathscr{O}$ (10 -3 ) for the primary variable while the other approaches yield errors that are approximately two orders of magnitude larger (that is, $\mathscr{O}$ (10 -1 )). Moreover, the spatial distribution of material properties obtained using the proposed framework is in close agreement with the true distribution, whereas the other approaches fare much worse. Additionally, the proposed approach is approximately 40% faster than its competitors, indicating its potential as a robust alternative for solving inverse problems in heterogeneous materials.

36 MATERIALS SCIENCE↗

Trajectory Shaper: A Solution for Disrupted Cooperative Adaptive Cruise Control

Cooperative adaptive cruise control (CACC) can effectively reduce energy consumption, alleviate traffic congestion, and enhance safety. However, communication-related constraints and uncooperative vehicle users can disrupt CACC during real-world operations, significantly undermining the putative benefits of CACC. To alleviate the negative impacts of disrupted CACC, this study develops the trajectory shaper (TS) methods as backup solutions for two scenarios: (i) communication between vehicles is infeasible, and vehicles execute adaptive cruise control (ACC) using local sensor measurements; (ii) follower vehicles reject forming a cooperative platoon and execute their local distributed controllers using the information attained via communication. When communication is infeasible, a distributed TS is devised on each vehicle to modify the sensor measurements, enabling safe and efficient ACC operations. When communication is available but uncooperative agents are involved, the lead vehicle of the platoon executes a centralized TS to modify the information shared with uncooperative agents, achieving optimal platoon-level performance. The centralized and distributed TSs are implemented based on the model predictive control algorithms to yield optimal modifications on input information. Robustness is also factored to tackle model uncertainties during TS operations to ensure safety and efficiency. Numerical experiments validate the control performance of the proposed TSs.

Zhou, Anye [ORNL] (ORCID:0000000301455579)↗

Adaptive Algebraic Derivative Estimation for Battery Electric Buses Energy Consumption Forecasting

The limited service life of onboard batteries for EVs is a challenge, underscoring the need for real-time battery usage prediction. This paper proposes an adaptive Algebraic Derivative Estimation (ADE) approach for forecasting the energy consumption of battery electric buses. By dynamically adjusting the sliding window length, the adaptive ADE retains the fixed-length ADE’s key advantage—namely, operating online without reliance on extensive historical datasets—while substantially bolstering forecast accuracy by actively trading estimation bias off estimation variance. Comparative experiments against both the conventional ADE with a fixed length and a representative machine learning algorithm, XGBoost, were conducted, with performance evaluated via root mean square error, mean absolute error, and the coefficient of determination. The results demonstrate that the proposed approach significantly outperforms baseline methods.

Cui, Tianyang [The University of Texas at Dallas]↗

A Broadly Adaptive Array of Dose-Constraint Templates for Planning of Intensity-Modulated Radiation Therapy for Advanced T-Stage Nasopharyngeal Carcinoma

Purpose: To develop and validate adaptive dose-constraint templates in intensity-modulated radiotherapy (IMRT) planning for advanced T-stage nasopharyngeal carcinoma (NPC). Method and Materials: Dose-volume histograms of clinically approved plans for 20 patients with advanced T-stage NPC were analyzed, and the pattern of distribution in relation to the degree of overlap between targets and organs at risk (OARs) was explored. An adaptive dose constraint template (ADCT) was developed based on the degree of overlap. Another set of 10 patients with advanced T-stage NPC was selected for validation. Results of the manual arm optimization protocol and the ADCT optimization protocol were compared with respect to dose optimization time, conformity indices, multiple-dose end points, tumor control probability, and normal tissue complication probability. Results: For the ADCT protocol, average time required to achieve an acceptable plan was 9 minutes, with one optimization compared with 94 minutes with more than two optimizations of the manual arm protocol. Target coverage was similar between the manual arm and ADCT plans. A more desirable dose distribution in the region of overlap between planning target volume and OARs was achieved in the ADCT plan. Dose end points of OARs were similar between the manual arm and ADCT plans. Conclusions: With the developed ADCT, IMRT treatment planning becomes more efficient and less dependent on the planner's experience on dose optimization. The developed ADCT is applicable to a wide range of advanced T-stage NPC treatment and has the potential to be applied in a broader context to IMRT planning for other cancer sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Fluorodeoxyglucose Positron Emission Tomography to Assess Tumor Volume During Radiotherapy for Non-Small-Cell Lung Cancer and Its Potential Impact on Adaptive Dose Escalation and Normal Tissue Sparing

Purpose: To quantify changes in fluorodeoxyglucose (FDG)-avid tumor volume on positron emission tomography/computed tomography (PET/CT) during the course of radiation therapy and examine its potential use in adaptive radiotherapy for tumor dose escalation or normal tissue sparing in patients with non-small-cell lung cancer (NSCLC). Methods and Materials: As part of a pilot study, patients with Stage I-III NSCLC underwent FDG-PET/CT before radiotherapy (RT) and in mid-RT (after 40-50 Gy). Gross tumor volumes were contoured on CT and PET scans obtained before and during RT. Three-dimensional conformal RT plans were generated for each patient, first using only pretreatment CT scans. Mid-RT PET volumes were then used to design boost fields. Results: Fourteen patients with FDG-avid tumors were assessed. Two patients had a complete metabolic response, and 2 patients had slightly increased FDG uptake in the adjacent lung tissue. Mid-RT PET scans were useful in the 10 remaining patients. Mean decreases in CT and PET tumor volumes were 26% (range, +15% to -75%) and 44% (range, +10% to -100%), respectively. Designing boosts based on mid-RT PET allowed for a meaningful dose escalation of 30-102 Gy (mean, 58 Gy) or a reduction in normal tissue complication probability (NTCP) of 0.4-3% (mean, 2%) in 5 of 6 patients with smaller yet residual tumor volumes. Conclusions: Tumor metabolic activity and volume can change significantly after 40-50 Gy of RT. Using mid-RT PET volumes, tumor dose can be significantly escalated or NTCP reduced. Clinical studies evaluating patient outcome after PET-based adaptive RT are ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Does the Entire Uterus Need to be Treated in Cancer of the Cervix? Role of Adaptive Brachytherapy

Purpose: To evaluate local control and toxicity by use of a method of adaptive cervical brachytherapy (ACB). Methods and Materials: From 1998 to 2008, we identified 65 cervical cancer patients with FIGO (International Federation of Gynecology and Obstetrics) Stage IB1-IVA disease who received definitive external beam radiation therapy and high-dose rate brachytherapy with tandem and ovoid applicators. As tumors regressed, 45 of 65 patients had the tandem source retracted from the uterine fundus at successive brachytherapy insertions, thus decreasing the number of {sup 192}Ir dwell positions. Tests of trend and Fisher's exact test were used to identify the effect of ACB on disease control and toxicity. Kaplan-Meier analyses were performed to evaluate disease control and late complications. Results: The median follow-up was 24.5 months. Of the patients, 92% received chemotherapy. The 3-year overall survival, 3-year disease-free survival, 3-year distant metastasis-free survival, and local control rates were 67%, 76%, 79%, and 97%, respectively. There was only 1 isolated local failure, and there were no local failures beyond 1 year. Distant failure was involved in 93% of recurrences. No significant trend was identified regarding the extent of retraction of the tandem source start position with either failure or toxicity. Acute and actuarial 3-year late Grade 3 toxicity or greater occurred in 24.6% and 17% of patients, respectively. Conclusions: ACB determined by clinical response yielded excellent local control rates. These data indicate that ACB may be useful in decreasing late toxicities from high-dose rate brachytherapy. With the advent of three-dimensional image-guided brachytherapy, additional methods to adapt treatment technique to changes in tumor volume warrant investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Planning in Intensity-Modulated Radiation Therapy for Head and Neck Cancers: Single-Institution Experience and Clinical Implications

Purpose: Anatomic changes and positional variability during intensity-modulated radiation therapy (IMRT) for head and neck cancer can lead to clinically significant dosimetric changes. We report our single-institution experience using an adaptive protocol and correlate these changes with anatomic and positional changes during treatment. Methods and Materials: Twenty-three sequential head and neck IMRT patients underwent serial computed tomography (CT) scans during their radiation course. After undergoing the planning CT scan, patients underwent planned rescans at 11, 22, and 33 fractions; a total of 89 scans with 129 unique CT plan combinations were thus analyzed. Positional variability and anatomic changes during treatment were correlated with changes in dosimetric parameters to target and avoidance structures between planning CT and subsequent scans. Results: A total of 15/23 patients (65%) benefited from adaptive planning, either due to inadequate dose to gross disease or to increased dose to organs at risk. Significant differences in primary and nodal targets (planning target volume, gross tumor volume, and clinical tumor volume), parotid, and spinal cord dosimetric parameters were noted throughout the treatment. Correlations were established between these dosimetric changes and weight loss, fraction number, multiple skin separations, and change in position of the skull, mandible, and cervical spine. Conclusions: Variations in patient positioning and anatomy changes during IMRT for head and neck cancer can affect dosimetric parameters and have wide-ranging clinical implications. The interplay between random positional variability and gradual anatomic changes requires careful clinical monitoring and frequent use of CT- based image-guided radiation therapy, which should determine variations necessitating new plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective, Risk-Adapted Strategy of Stereotactic Body Radiotherapy for Early-Stage Non-Small-Cell Lung Cancer: Results of a Phase II Trial

Purpose: Validation of a prospective, risk-adapted strategy for early-stage non-small-cell lung cancer (NSCLC) patients treated with stereotactic body radiotherapy (SBRT). Methods and Materials: Patients with a T1-3N0M0 (American Joint Committee on Cancer 6th edition) NSCLC were accrued. Using the Radiation Therapy Oncology Group definition, patients were treated to a total dose of 60,Gy in three fractions for peripherally located lesions and four fractions for centrally located lesions. The primary endpoint was toxicity, graded according to the Radiation Therapy Oncology Group acute and late morbidity scoring system, and the National Cancer Institute Common Terminology Criteria for Adverse Events Version 3.0. Secondary endpoints were local control and survival. Results: A total of 40 patients were included, 17 with a centrally located lesion. The lung toxicity-free survival estimate at 2 years was 74% and was related to the location (central vs. peripheral) and the size of the target volume. No dose volumetric parameters could predict the occurrence of lung toxicity. One patient died because of treatment-related toxicity. The 1-year and 2-year local progression-free survival estimates were 97% and 84%, respectively, and were related to stage (T1 vs. T2) related (p = 0.006). Local failure was not more frequent for patients treated in four fractions. The 1-year local progression-free survival estimate dropped below 80% for lesions with a diameter of more than 4 cm. Conclusion: The proposed risk-adapted strategy for both centrally and peripherally located lesions showed an acceptable toxicity profile while maintaining excellent local control rates. The correlation between local control and tumor diameter calls for the inclusion of tumor stage as a variable in future study design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiotherapy for Head-and-Neck Cancer: Initial Clinical Outcomes From a Prospective Trial

Purpose: To present pilot toxicity and survival outcomes for a prospective trial investigating adaptive radiotherapy (ART) for oropharyngeal squamous cell carcinoma. Methods and Materials: A total of 24 patients were enrolled in an institutional review board-approved clinical trial; data for 22 of these patients were analyzed. Daily CT-guided setup and deformable image registration permitted serial mapping of clinical target volumes and avoidance structures for ART planning. Primary site was base of tongue in 15 patients, tonsil in 6 patient, and glossopharyngeal sulcus in 1 patient. Twenty patients (91%) had American Joint Committee on Cancer (AJCC) Stage IV disease. T stage distribution was 2 T1, 12 T2, 3 T3, 5 T4. N stage distribution was 1 N0, 2 N1, 5 N2a, 12 N2b, and 2 N2c. Of the patients, 21 (95%) received systemic therapy. Results: With a 31-month median follow-up (range, 13-45 months), there has been no primary site failure and 1 nodal relapse, yielding 100% local and 95% regional disease control at 2 years. Baseline tumor size correlated with absolute volumetric treatment response (p = 0.018). Parotid volumetric change correlated with duration of feeding tube placement (p = 0.025). Acute toxicity was comparable to that observed with conventional intensity-modulated radiotherapy (IMRT). Chronic toxicity and functional outcomes beyond 1 year were tabulated. Conclusion: This is the first prospective evaluation of morbidity and survival outcomes in patients with locally advanced head-and-neck cancer treated with automated adaptive replanning. ART can provide dosimetric benefit with only one or two mid-treatment replanning events. Our preliminary clinical outcomes document functional recovery and preservation of disease control at 1-year follow-up and beyond.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Atlas-Based Electron Density Mapping Method for Magnetic Resonance Imaging (MRI)-Alone Treatment Planning and Adaptive MRI-Based Prostate Radiation Therapy

Purpose: Prostate radiation therapy dose planning directly on magnetic resonance imaging (MRI) scans would reduce costs and uncertainties due to multimodality image registration. Adaptive planning using a combined MRI-linear accelerator approach will also require dose calculations to be performed using MRI data. The aim of this work was to develop an atlas-based method to map realistic electron densities to MRI scans for dose calculations and digitally reconstructed radiograph (DRR) generation. Methods and Materials: Whole-pelvis MRI and CT scan data were collected from 39 prostate patients. Scans from 2 patients showed significantly different anatomy from that of the remaining patient population, and these patients were excluded. A whole-pelvis MRI atlas was generated based on the manually delineated MRI scans. In addition, a conjugate electron-density atlas was generated from the coregistered computed tomography (CT)-MRI scans. Pseudo-CT scans for each patient were automatically generated by global and nonrigid registration of the MRI atlas to the patient MRI scan, followed by application of the same transformations to the electron-density atlas. Comparisons were made between organ segmentations by using the Dice similarity coefficient (DSC) and point dose calculations for 26 patients on planning CT and pseudo-CT scans. Results: The agreement between pseudo-CT and planning CT was quantified by differences in the point dose at isocenter and distance to agreement in corresponding voxels. Dose differences were found to be less than 2%. Chi-squared values indicated that the planning CT and pseudo-CT dose distributions were equivalent. No significant differences (p > 0.9) were found between CT and pseudo-CT Hounsfield units for organs of interest. Mean {+-} standard deviation DSC scores for the atlas-based segmentation of the pelvic bones were 0.79 {+-} 0.12, 0.70 {+-} 0.14 for the prostate, 0.64 {+-} 0.16 for the bladder, and 0.63 {+-} 0.16 for the rectum. Conclusions: The electron-density atlas method provides the ability to automatically define organs and map realistic electron densities to MRI scans for radiotherapy dose planning and DRR generation. This method provides the necessary tools for MRI-alone treatment planning and adaptive MRI-based prostate radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Breast Radiation Therapy Using Modeling of Tissue Mechanics: A Breast Tissue Segmentation Study

Purpose: To validate and compare the accuracy of breast tissue segmentation methods applied to computed tomography (CT) scans used for radiation therapy planning and to study the effect of tissue distribution on the segmentation accuracy for the purpose of developing models for use in adaptive breast radiation therapy. Methods and Materials: Twenty-four patients receiving postlumpectomy radiation therapy for breast cancer underwent CT imaging in prone and supine positions. The whole-breast clinical target volume was outlined. Clinical target volumes were segmented into fibroglandular and fatty tissue using the following algorithms: physical density thresholding; interactive thresholding; fuzzy c-means with 3 classes (FCM3) and 4 classes (FCM4); and k-means. The segmentation algorithms were evaluated in 2 stages: first, an approach based on the assumption that the breast composition should be the same in both prone and supine position; and second, comparison of segmentation with tissue outlines from 3 experts using the Dice similarity coefficient (DSC). Breast datasets were grouped into nonsparse and sparse fibroglandular tissue distributions according to expert assessment and used to assess the accuracy of the segmentation methods and the agreement between experts. Results: Prone and supine breast composition analysis showed differences between the methods. Validation against expert outlines found significant differences (P<.001) between FCM3 and FCM4. Fuzzy c-means with 3 classes generated segmentation results (mean DSC = 0.70) closest to the experts' outlines. There was good agreement (mean DSC = 0.85) among experts for breast tissue outlining. Segmentation accuracy and expert agreement was significantly higher (P<.005) in the nonsparse group than in the sparse group. Conclusions: The FCM3 gave the most accurate segmentation of breast tissues on CT data and could therefore be used in adaptive radiation therapy-based on tissue modeling. Breast tissue segmentation methods should be used with caution in patients with sparse fibroglandular tissue distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiation Therapy for Postprostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiation Therapy

Purpose: Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials: Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (D{sub min}) with the planned D{sub min} to the CTV. Treatments were considered adequate if the delivered CTV D{sub min} is at least 95% of the planned CTV D{sub min}. Results: Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: −0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion: Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗