Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

U.S. Balance-of-Station Cost Drivers and Sensitivities (Presentation)

With balance-of-system (BOS) costs contributing up to 70% of the installed capital cost, it is fundamental to understanding the BOS costs for offshore wind projects as well as potential cost trends for larger offshore turbines. NREL developed a BOS model using project cost estimates developed by GL Garrad Hassan. Aspects of BOS covered include engineering and permitting, ports and staging, transportation and installation, vessels, foundations, and electrical. The data introduce new scaling relationships for each BOS component to estimate cost as a function of turbine parameters and size, project parameters and size, and soil type. Based on the new BOS model, an analysis to understand the non‐turbine costs has been conducted. This analysis establishes a more robust baseline cost estimate, identifies the largest cost components of offshore wind project BOS, and explores the sensitivity of the levelized cost of energy to permutations in each BOS cost element. This presentation shows results from the model that illustrates the potential impact of turbine size and project size on the cost of energy from U.S. offshore wind plants.

17 WIND ENERGY↗

K-25 Structural Separation and Demolition

The K-25 building is a former gaseous diffusion plant, built in 1944-1945 as part of the United States Manhattan Project. The structure was the largest structure under one roof, surpassed only by the Pentagon. Together the three wings represent about 17.8 hectare (44 acres) under roof and are generally about 18.3 meters (60 ft.) high on the outside face and approximately 12.2 meters (40 ft.) high on the inside face. The entire structure was built in the shape of a 'U', with a lateral distance of approximately one mile. It was constructed in individual building units with each unit connected using expansion joint-type connection. A single unit is approximately 24.4 meters (80 ft.) across and 122 meters (400 ft.) deep. The northern structure is connected to the eastern and western structures at the upper level floors. The four-level, U-shaped building is a steel-frame structure with corrugated cement-asbestos siding. The cell level is an elevated concrete structure supported by reinforced concrete columns located in the basement, or vault area. The vault area can be accessed at grade level from the outside perimeter. Inside the courtyard, the grade level has been raised to provide entry to the second or cell floor level. An engineering evaluation of the structure was performed to determine the condition of the structure and possibility of unplanned collapse of any portion of the structure. The evaluation included physical inspections, calculations for wind, pre-demolition loads, and evaluation of failure modes. The results of the evaluation have provided guidance for the demolition plan and the development of criteria for protection of personnel performing pre-demolition activities. Challenges include degradation of the structure that necessitated repair, dealing with changes in the code revisions from both the American Concrete Institute (ACI) and the American Institute of Steel Construction (AISC), access to areas of the structure that were not necessarily designed for access, and acceleration of the building degradation due to the pre-demolition activities. When a full building is evaluated, 50 percent of wind and applied forces are dissipated in 3 units and 80 percent is dissipated in 12 units. The forces are basically linear for the first 6 units once the building is opened at the start of demolition. Some column buckling, based on current codes, was noted in the analysis that would have to be mitigated to ensure a controlled demolition. Loading for the removal of the equipment required structural engineering evaluation of the certainty of the load and the application of the load. Corbels are being evaluated through an inspection program and criteria for repair based on current loading and anticipated additional live loads. Access issues continue to be a challenge and have created the need for a significant fall protection program. Other areas of access require different approaches and engineering solutions, sometime considering ultimate strength design versus standard yield stress design. An evaluation of separating a wing into two sections to allow for worker re-entry to perform pre-demolition activities during the demolition off shift was conducted. The evaluation has shown that because of both design and history of the K-25 and K-27 Buildings, significant care and attention is needed to demolish these structures from a structural perspective. When the project schedule issues are overlaid, that may demand workers in other parts of the structure after demolition has begun, the structural issues become severe, demanding exacting analysis and significant controls to ensure the safety of the workers both in and outside the building performing the demolition work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Superhydrophobic Surfaces for Anti-icing in a Low-Temperature Wind Tunnel

In this study, a closed loop low-temperature wind tunnel was custom-built and uniquely used to investigate the anti-icing mechanism of superhydrophobic surfaces in regulated flow velocities, temperatures, humidity, and water moisture particle sizes. Silica nanoparticle-based hydrophobic coatings were tested as superhydrophobic surface models. During tests, images of ice formation were captured by a camera and used for analysis of ice morphology. Prior to and after wind tunnel testing, apparent contact angles of water sessile droplets on samples were measured by a contact angle meter to check degradation of surface superhydrophobicity. A simple peel test was also performed to estimate adhesion of ice on the surfaces. When compared to an untreated sample, superhydrophobic surfaces inhibited initial ice formation. After a period of time, random droplet strikes attached to the superhydrophobic surfaces and started to coalesce with previously deposited ice droplets. These sites appear as mounds of accreted ice across the surface. The appearance of the ice formations on the superhydrophobic samples is white rather than transparent, and is due to trapped air. These ice formations resemble soft rime ice rather than the transparent glaze ice seen on the untreated sample. Compared to untreated surfaces, the icing film formed on superhydrophobic surfaces was easy to peel off by shear flows.

36 MATERIALS SCIENCE↗

Low-Maintenance Wind Power System

Turbines of 1, 3 and 30 kW were designed, prototyped and evaluated. A 55 kW unit has been preliminarily designed. Two 1 kW alpha units and a 3 kW alpha unit were delivered to the US in 2005 and Empire Magnetics provided custom alternators for the units. After evaluation, the 6 bladed, 3 kW unit was chosen for beta fabrication and 5 units were delivered to the US in December, 2009 while others remained for testing in Russia.

42 ENGINEERING↗

Outflowing diffuse gas in the active galactic nucleus of NGC 1068

Spectra of the archetypal Type II Seyfert galaxy NGC 1068 in a narrow wavelength interval near 3.7 μm have revealed a weak absorption feature due to two lines of the molecular ion H{sub 3}{sup +}. The observed wavelength of the feature corresponds to a velocity of −70 km s{sup −1} relative to the systemic velocity of the galaxy, implying an outward flow from the nucleus along the line of sight. The absorption by H{sub 3}{sup +} along with the previously known broad hydrocarbon absorption at 3.4μm are probably formed in diffuse gas that is in close proximity to the continuum source, i.e., within a few tens of parsecs of the central engine. Based on that conclusion and the measured H{sub 3}{sup +} absorption velocity and with the assumption of a spherically symmetric wind we estimate a rate of mass outflow from the active galactic nucleus of ∼1 M{sub ⊙} yr{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Review of Natural Phenomena Hazard (NPH) Assessments for the Hanford 200 Areas (Non-Seismic)

The purpose of this review is to assess the need for updating Natural Phenomena Hazard (NPH) assessments for the Hanford 200 Areas, as required by DOE Order 420.1B Chapter IV, Natural Phenomena Hazards Mitigation, based on significant changes in state-of-the-art NPH assessment methodology or site-specific information. The review includes all natural phenomena hazards with the exception of seismic/earthquake hazards, which are being addressed under a separate effort. It was determined that existing non-seismic NPH assessments are consistent with current design methodology and site specific data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Suspended and Restored Activities of a Nearby Supermassive Black Hole

The discovery of spectral type transition of active galactic nuclei (AGNs), the so-called “changing-look” (CL) phenomenon, challenges the widely accepted AGN paradigm, not only in the orientation-based unified model, but also in the standard disk model. In past decades, only a couple of nearby repeat changing-look active galactic nuclei (CL-AGNs) have been identified. Here we report spectroscopic observations of UGC 3223 over the course of 18 yr, from 2001 onwards. Combining the spectrum taken in 1987 by Stirpe, we have witnessed its type transitions from 1.5→2.0→1.8 over 32 yr, and captured a long-lived (at least 10 yr) thorough “turn-off” state with a spectrum typical of a Seyfert 2 galaxy. The long-term thorough turn-off state probably suggests a once-dormant and an awakening central engine in UGC 3223. We argue that the (dis)appearance of the broad Balmer emission lines can be explained by the disk–wind broad-line region model given the evolution of the calculated Eddington ratio of accretion of the supermassive black hole.

79 ASTRONOMY AND ASTROPHYSICS↗

Source apportionment of airborne particulate matter for the speciation trends network site in Cleveland, OH

Aerosol composition data from the Speciation Trends Network (STN) site (East 14th Street) in Cleveland, OH, were analyzed by advanced receptor model methods for source apportionment as well as by the standard positive matrix factorization (PMF) using PMF2. These different models are used in combination to test model limitations. These data were 24-hr average mass concentrations and compositions obtained for samples taken every third day from 2001 to 2003. The Multilinear Engine (ME) was used to solve an expanded model to estimate the source profiles and source contributions and also to investigate the wind speed, wind direction, time-of-day, weekend/weekday, and seasonal effects. PMF2 was applied to the same dataset. Potential source contribution function (PSCF) and conditional probability function (CPF) analyses were used to locate the regional and local sources using the resolved source contributions and appropriate meteorological data. Very little difference was observed between the results of the expanded model and the PMF2 values for the profiles and source contribution time series. The identified sources were as ferrous smelter, secondary sulfate, secondary nitrate, soil/combustion mixture, steel mill, traffic, wood smoke, and coal burning. The CPF analysis was useful in helping to identify local sources, whereas the PSCF results were only useful for regional source areas. Both of these analyses were more useful than the wind directional factor derived from the expanded factor analysis. However, the expanded analysis provided direct information on seasonality and day-of-week behavior of the sources. 28 refs., 8 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗

Graphite for Advanced Nuclear Reactors: Deployment Readiness Review

Historically, graphite has been used in numerous reactor technologies, including research/test reactors and, commercially, in advanced gas reactors. These non-metallic materials can play a key role as internal core structures, reflectors, or neutron moderators, making them important for deployment of certain advanced reactor technologies. This report explores the industry readiness for graphite material deployment, documenting Codes and Standards applicable to their design, qualification, and manufacturing. Discussions also examine the manufacturing processes, aging/degradation, inspection techniques, and disposal options. The report covers the current status, documents gaps, and proposes some conclusions about approaches to managing some of the current gaps.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimal Design of Megahertz $LLC$ Converter for 48-V Bus Converter Application

Intermediate bus architecture employing 48-V bus converters is widely used in power supply applications. With the rapid increase of demanded power by these loads, higher efficiency and power density are driving better performance power management solutions. In this article, a Gallium Nitride (GaN) based design of a two-stage solution is proposed. The first stage is a multi-phase Buck for regulation. The second stage is an LLC converter with a fixed switching frequency for isolation. The detailed design and optimization of the LLC converter are studied. To achieve high power density and high efficiency, the transformer design becomes critical at megahertz frequency. The matrix transformer concept is applied and a merged winding structure is used for flux cancellation, which effectively reduces the ac winding losses. A novel primary termination and via structure is proposed, resulting in a great loss reduction. In addition, to study the current sharing of parallel winding layers, a 1-D analytic model is proposed, and a symmetrical winding layer scheme is used to balance the current distribution. Finally, the prototype for the two-stage bus converter is developed, with a peak efficiency of 96% and a power density of 615 W/in 3 .

42 ENGINEERING↗

Establishment of Small Wind Regional Test Centers

The rapid growth of the small wind turbine (SWT) market is attracting numerous entrants. Small wind turbine purchasers now have many options, but often lack information (such as third-party certification) to select a quality turbine. Most SWTs do not have third-party certification due to the expense and difficulty of the certification process. Until recently, the only SWT certification bodies were in Europe. In North America, testing has been limited to a small number of U.S. Department of Energy (DOE) subsidized tests conducted at the National Renewable Energy Laboratory's (NREL) National Wind Technology Center (NWTC) under the ongoing Independent Testing Project. During the past few years, DOE, the National Renewable Energy Laboratory (NREL), and some states have worked with the North American SWT industry to create a SWT certification infrastructure. The goal is to increase the number of certified turbines and gain greater consumer confidence in SWT technology. The American Wind Energy Association (AWEA) released the AWEA Small Wind Turbine Performance and Safety Standard, AWEA Standard 9.1 - 2009, in December 2009. The Small Wind Certification Council (SWCC) and Intertek, North American SWT certification bodies, began accepting applications for certification to the AWEA standard in 2010. To reduce certification testing costs, DOE and NREL are providing financial and technical assistance for an initial round of tests at four SWT test sites, which were selected through a competitive solicitation. The four organizations selected are Windward Engineering (Utah), The Alternative Energy Institute at West Texas A and M (Texas), a consortium consisting of Kansas State University and Colby Community College (Kansas), and Intertek (New York). Each organization will test two small wind turbines as part of their respective subcontracts with DOE and NREL. The testing results will be made publically available. The goal is to establish a lower-cost U.S. small wind testing capability that will lead to increased SWT certification. Turbine installation is ongoing. Testing began in early 2011 and is scheduled to conclude in mid-late 2012.

17 WIND ENERGY↗

Constrained power reference control for wind turbines

The cost of wind energy can be reduced by controlling the power reference of a turbine to increase energy capture, while maintaining load and generator speed constraints. We apply standard torque and pitch controllers to the direct inputs of the turbine and use their set points to change the power output and reduce generator speed and blade load transients. A power reference controller increases the power output when conditions are safe and decreases it when problematic transient events are expected. Transient generator speeds and blade loads are estimated using a gust measure derived from a wind speed estimate. A hybrid controller decreases the power rating from a maximum allowable power. Compared to a baseline controller, with a constant power reference, the proposed controller results in generator speeds and blade loads that do not exceed the original limits, increases tower fore-aft damage equivalent loads by 1%, and increases the annual energy production by 5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination of Wind Exposure Category and Basic Wind Speed for B332 and Other Facilities Located within Superblock

This document assesses of the typical surface terrain for the LLNL Site 200 Campus surrounding B332 in accordance with ASCE 7-16 and demonstrates that wind Exposure Category B can be applied to B332 and the other buildings and structures located within the fenced perimeter of Superblock. When compensating for the Exposure Category B surface terrain surrounding B332 and Superblock, calculations show that the ANS 2.3 WDC-3 Basic Wind Speed for B332 is adjusted from 118 mph to 100 mph and the WDC-2 Basic Wind Speed is adjusted from 115 mph to 98 mph.

42 ENGINEERING↗

High-Pressure, Low Temperature Composite Nozzles for Long-Term H2 Dispensing (Final Report)

Final report on evaluation of NanoSonic high pressure hydrogen hoses under CRADA 399. NanoSonic hose liners, fiber winding, and hose end crimp fittings were analyzed for material properties, design, and burst test performance. The hose burst pressures exceeded 100 MPa under -130C sub ambient conditions. Hose crimp fittings were found to have some defects from assembly that impacted burst pressures. The use of digital image correlation provided unique insight to the crimped fitting influence on the composite material and the winding pattern during burst testing.

08 HYDROGEN↗

Block Island Survey and Deployment Operations Data

This dataset contains survey, navigation, and platform-design data supporting instrument deployment and positioning during the 2016-2017 RODEO field operations at Block Island. It includes an acoustic localization software toolkit and its Block Island position solutions, R/V Tioga ship navigation and underway data, CTD casts, ship-track charts, and engineering designs for the deployed moorings and arrays.

17 WIND ENERGY↗

System and method for monitoring and controlling stator winding temperature in a de-energized AC motor

A system and method for measuring and controlling stator winding temperature in an AC motor while idling is disclosed. The system includes a circuit having an input connectable to an AC source and an output connectable to an input terminal of a multi-phase AC motor. The circuit further includes a plurality of switching devices to control current flow and terminal voltages in the multi-phase AC motor and a controller connected to the circuit. The controller is configured to activate the plurality of switching devices to create a DC signal in an output of the motor control device corresponding to an input to the multi-phase AC motor, determine or estimate a stator winding resistance of the multi-phase AC motor based on the DC signal, and estimate a stator temperature from the stator winding resistance. Temperature can then be controlled and regulated by DC injection into the stator windings.

42 ENGINEERING↗

Resonant Enhancement of Turbulent Energy Dissipation

We periodically modulate a turbulent wind-tunnel flow with an active grid. We find a resonant enhancement of the mean turbulent dissipation rate at a modulation frequency which equals the large-eddy turnover rate. Thus, we find the best frequency to inject energy into a turbulent flow. The resonant response is characterized by the emergence of vortical structures in the flow and depends on the spatial mode of the stirring grid.

42 ENGINEERING↗