Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Effective Jet Properties for the Prediction of Turbulent Mixing Noise Reduction by Water Injection

A one-dimensional control volume formulation is developed for the determination of jet mixing noise reduction due to water injection. The analysis starts from the conservation of mass, momentum and energy for the control volume, and introduces the concept of effective jet parameters (jet temperature, jet velocity and jet Mach number). It is shown that the water to jet mass flow rate ratio is an important parameter characterizing the jet noise reduction on account of gas-to-droplet momentum and heat transfer. Two independent dimensionless invariant groups are postulated, and provide the necessary relations for the droplet size and droplet Reynolds number. Results are presented illustrating the effect of mass flow rate ratio on the jet mixing noise reduction for a range of jet Mach number and jet Reynolds number. Predictions from the model show satisfactory comparison with available test data on supersonic jets. The results suggest that significant noise reductions can be achieved at increased flow rate ratios.

Kandula, Max↗

Venous Gas Embolism: Review to Quantify a Safe Volume of Air in Intravenous Fluids Bags for Spaceflight Applications

INTRODUCTION: The ability to create intravenous fluids (IVF) in-situ from the potable water supply of a spaceflight vehicle or habitat is a desired capability for an exploration medical system. In order to define an acceptable volume of air in IVF bags, an understanding of the volume of venous gas embolism as it relates to negative outcomes is needed. The purpose of this study is to review the literature to determine if there is a known volume of gas that contributes to mortality and/or morbidity that could be used to define requirements for rapid IVF infusion in microgravity. METHODS: A literature review was conducted of the PubMed database using the syntax: (Venous) AND (Gas OR Air) AND (Embolism) AND (Morbidity) AND (Mortality) AND (Volume) as well as manual review of references from relevant articles. 151 articles were screened excluding partial text and pediatric articles. Studies were reviewed for identification of volume of venous gas embolism associated with morbidity and/or mortality, which identified 27 articles. RESULTS: Reviewed literature included animal studies, case reports, and review articles. A high variation of proposed volumes contributing to mortality was reported. The limited human data values ranged from 20 ml to 200 ml of infused air with mortality estimated to be 48 – 80%. No studies evaluated human morbidity in any capacity. DISCUSSION: The lack of consensus on the safe volume of infused air has potential ramifications for IVF use in spaceflight as current technologies to create IVF from potable water may introduce air in IVF bags. While current microgravity infusion protocols call for the use of inline air removal filters, commercially available options have flow rate limitations that preclude rapid infusion in a resuscitation scenario. Such filters may be used in parallel to increase flow rate, but the time required to set up such a system may exclude its use during a medical emergency. Additionally, these consumable filters drive up the overall mass and volume of the medical system. Identification of a safe volume of air in IVF would allow for guidelines for the in-situ production of IVF in future spaceflight vehicles/habitats.

Christopher R Woodard↗

Disease Control After Reduced Volume Conformal and Intensity Modulated Radiation Therapy for Childhood Craniopharyngioma

Purpose: To estimate the rate of disease control after conformal radiation therapy using reduced clinical target volume (CTV) margins and to determine factors that predict for tumor progression. Methods and Materials: Eighty-eight children (median age, 8.5 years; range, 3.2-17.6 years) received conformal or intensity modulated radiation therapy between 1998 and 2009. The study group included those prospectively treated from 1998 to 2003, using a 10-mm CTV, defined as the margin surrounding the solid and cystic tumor targeted to receive the prescription dose of 54 Gy. The CTV margin was subsequently reduced after 2003, yielding 2 groups of patients: those treated with a CTV margin greater than 5 mm (n=26) and those treated with a CTV margin less than or equal to 5 mm (n=62). Disease progression was estimated on the basis of additional variables including sex, race, extent of resection, tumor interventions, target volume margins, and frequency of weekly surveillance magnetic resonance (MR) imaging during radiation therapy. Median follow-up was 5 years. Results: There was no difference between progression-free survival rates based on CTV margins (>5 mm vs ≤5 mm) at 5 years (88.1% ± 6.3% vs 96.2% ± 4.4% [P=.6386]). There were no differences based on planning target volume (PTV) margins (or combined CTV plus PTV margins). The PTV was systematically reduced from 5 to 3 mm during the time period of the study. Factors predictive of superior progression-free survival included Caucasian race (P=.0175), no requirement for cerebrospinal fluid shunting (P=.0066), and number of surveillance imaging studies during treatment (P=.0216). Patients whose treatment protocol included a higher number of weekly surveillance MR imaging evaluations had a lower rate of tumor progression. Conclusions: These results suggest that targeted volume reductions for radiation therapy using smaller margins are feasible and safe but require careful monitoring. We are currently investigating the differences in outcome based on host factors to explain the results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Brachytherapy Case Volumes by Academic and Nonacademic Practices: Implications for Future Residency Training

Purpose: The use of prostate brachytherapy has continued to decline in the United States. We examined the national practice patterns of both academic and nonacademic practices performing prostate brachytherapy by case volume per year to further characterize the decline and postulate the effect this trend might have on training the next generation of residents. Methods and Materials: Men diagnosed with prostate cancer who had undergone radiation therapy in 2004 to 2012 were identified. The annual brachytherapy case volume at each facility was determined and further categorized into ≤12 cases per year (ie, an average of ≤1 cases per month), 13 to 52 cases per year, and ≥53 cases per year (ie, an average of ≥1 cases per week) in academic practices versus nonacademic practices. Results: In 2004 to 2012, academic practices performing an average of ≤1 brachytherapy cases per month increased from 56.4% to 73.7%. In nonacademic practices, this percentage increased from 60.2% to 77.4% (P<.0001 for both). Practices performing an average of ≥1 cases per week decreased among both academic practices (from 6.7% to 1.5%) and nonacademic practices (from 4.5% to 2.7%). Conclusions: Both academic and nonacademic radiation oncology practices have demonstrated a significant reduction in the use of prostate brachytherapy from 2004 to 2012. With the case volume continuing to decline, it is unclear whether we are prepared to train the next generation of residents in this critical modality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rod Internal Pressure Distribution and Uncertainty Analysis Using FRAPCON

The discharge rod internal pressure (RIP) and cladding hoop stress (CHS) distributions are quantified for Watts Bar Nuclear Unit 1 (WBN1) fuel rods by modeling core cycle design data, operation data, and as-built fuel enrichments and densities of each fuel rod in FRAPCON-3.5. A methodology is developed that tracks intercycle assembly movements and assembly batch fabrication information to build individual FRAPCON inputs for each evaluated WBN1 fuel rod. An alternate model for the amount of helium released from the zirconium diboride (ZrB 2 ) integral fuel burnable absorber (IFBA) layer is derived and applied to FRAPCON output data to quantify the RIP and CHS for these types of fuel rods. SCALE/Polaris is used to quantify fuel rod–specific spectral quantities and the amount of gaseous fission products produced in the fuel for use in FRAPCON inputs. Fuel rods with ZrB 2 IFBA layers (i.e., IFBA rods) are determined to have RIP predictions that are elevated when compared to fuel rods without IFBA layers (i.e., standard rods) despite the fact that IFBA rods often have reduced fill pressures and annular fuel pellets. The primary contributor to elevated RIP predictions at burnups less than and greater than 30 GWd/tonne U is determined to be the total fuel rod void volume and the amount of released fission gas in the fuel rod, respectively. Cumulative distribution functions (CDFs) are prepared from the distribution of RIP and CHS predictions for all standard and IFBA rods. The provided CDFs allow for the determination of the portion of WBN1 fuel rods that exceeds a specified RIP or CHS limit. Results are separated into IFBA and standard rods so that the two groups may be analyzed individually. FRAPCON results are provided in sufficient detail to enable the recalculation of the RIP while considering any desired plenum gas temperature, total void volume, or total amount of gas present in the void volume. A method to predict the CHS from a determined or assumed RIP is also proposed that is based on the approximately linear relationship between the CHS and the RIP. Finally, improvements to the computational methodology of FRAPCON are proposed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Transfer of thermal microwaves in the atmosphere, volume 1

The Mie theory is used to determine the absorption and scattering properties of liquid hydrometeors at 27 microwave frequencies from 500 MHz to 60 GHz. Based on the Marshall-Palmer distribution of drop sizes, regression equations are developed for the volume absorption coefficient of rain as a function of its temperature and content of liquid water.

Paris, J. F.↗

Comparison of Magnetic Resonance Imaging and Computed Tomography for Breast Target Volume Delineation in Prone and Supine Positions

Purpose: To determine whether T2-weighted MRI improves seroma cavity (SC) and whole breast (WB) interobserver conformity for radiation therapy purposes, compared with the gold standard of CT, both in the prone and supine positions. Methods and Materials: Eleven observers (2 radiologists and 9 radiation oncologists) delineated SC and WB clinical target volumes (CTVs) on T2-weighted MRI and CT supine and prone scans (4 scans per patient) for 33 patient datasets. Individual observer's volumes were compared using the Dice similarity coefficient, volume overlap index, center of mass shift, and Hausdorff distances. An average cavity visualization score was also determined. Results: Imaging modality did not affect interobserver variation for WB CTVs. Prone WB CTVs were larger in volume and more conformal than supine CTVs (on both MRI and CT). Seroma cavity volumes were larger on CT than on MRI. Seroma cavity volumes proved to be comparable in interobserver conformity in both modalities (volume overlap index of 0.57 (95% Confidence Interval (CI) 0.54-0.60) for CT supine and 0.52 (95% CI 0.48-0.56) for MRI supine, 0.56 (95% CI 0.53-0.59) for CT prone and 0.55 (95% CI 0.51-0.59) for MRI prone); however, after registering modalities together the intermodality variation (Dice similarity coefficient of 0.41 (95% CI 0.36-0.46) for supine and 0.38 (0.34-0.42) for prone) was larger than the interobserver variability for SC, despite the location typically remaining constant. Conclusions: Magnetic resonance imaging interobserver variation was comparable to CT for the WB CTV and SC delineation, in both prone and supine positions. Although the cavity visualization score and interobserver concordance was not significantly higher for MRI than for CT, the SCs were smaller on MRI, potentially owing to clearer SC definition, especially on T2-weighted MR images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-177: A Computational Approach for Determination of Anisotropic PTV Margins Based On Statistical Shape Analysis for Prostate Cancer Radiotherapy

Purpose: Our aim of this study was to propose a computational approach for determination of anisotropic planning target volume (PTV) margins based on statistical shape analysis with taking into account time variations of clinical target volume (CTV) shapes for the prostate cancer radiation treatment planning (RTP). Methods: Systematic and random setup errors were measured using orthogonal projection and cone beam computed tomography (CBCT) images for data of 20 patients, who underwent the intensity modulated radiation therapy for prostate cancer. The low-risk, intermediate-risk, and high-risk CTVs were defined as only a prostate, a prostate plus proximal 1-cm seminal vesicles, and a prostate plus proximal 2-cm seminal vesicles, respectively. All CTV regions were registered with a reference CTV region with a median volume to remove the effect of the setup errors, and converted to a point distribution models. The systematic and random errors for translations of CTV regions were automatically evaluated by analyzing the movements of centroids of CTV regions. The random and systematic errors for shape variations of CTV regions were obtained from covariance matrices based on point distributions for the CTV contours on CBCT images of 72 fractions of 10 patients. Anisotropic PTV margins for 6 directions (right, left, anterior, posterior, superior and inferior) were derived by using Yoda’s PTV margin model. Results: PTV margins with and without shape variations were 5.75 to 8.03 mm and 5.23 to 7.67 mm for low-risk group, 5.87 to 8.33 mm and 5.23 to 7.67 mm for intermediate-risk group, and 5.88 to 8.25 mm and 5.29 to 7.82 mm for highrisk group, respectively. Conclusion: The proposed computational approach could be feasible for determination of the anisotropic PTV margins with taking into account CTV shape variations for the RTP.

60 APPLIED LIFE SCIENCES↗

A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments

Treatment plans are usually designed, optimized, and evaluated based on the total 3D dose distribution, motivating a total 3D dose verification. The purpose of this study was to develop a 2D transmission-dosimetry method using an electronic portal imaging device (EPID) into a simple 3D method that provides 3D dose information. In the new method, the dose is reconstructed within the patient volume in multiple planes parallel to the EPID for each gantry angle. By summing the 3D dose grids of all beams, the 3D dose distribution for the total treatment fraction is obtained. The algorithm uses patient contours from the planning CT scan but does not include tissue inhomogeneity corrections. The 3D EPID dosimetry method was tested for IMRT fractions of a prostate, a rectum, and a head-and-neck cancer patient. Planned and in vivo-measured dose distributions were within 2% at the dose prescription point. Within the 50% isodose surface of the prescribed dose, at least 97% of points were in agreement, evaluated with a 3D {gamma} method with criteria of 3% of the prescribed dose and 0.3 cm. Full 3D dose reconstruction on a 0.1x0.1x0.1 cm{sup 3} grid and 3D {gamma} evaluation took less than 15 min for one fraction on a standard PC. The method allows in vivo determination of 3D dose-volume parameters that are common in clinical practice. The authors conclude that their EPID dosimetry method is an accurate and fast tool for in vivo dose verification of IMRT plans in 3D. Their approach is independent of the treatment planning system and provides a practical safety net for radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Holistic Framework for Environmental Flows Determination in Hydropower Contexts

Among the ecological science community, the consensus view is that the natural flow regime sustains the ecological integrity of river systems. This prevailing viewpoint by many environmental stakeholders has progressively led to increased pressure on hydropower dam owners to change plant operations to affect downstream river flows with the intention of providing better conditions for aquatic biological communities. Identifying the neccessary magnitude, frequency, duration, timing, or rate of change of stream flows to meet ecological needs in a hydropower context is challenging because the ecological responses to changes in flows may not be fully known, there are usually a multitude of competing users of flow, and implementing environmental flows usually comes at a price to energy production. Realistically, hydropower managers must develop a reduced set of goals that provide the most benefit to the identified ecological needs. As a part of the Department of Energy (DOE) Water Power Program, the Instream Flow Project (IFP) was carried out by Oak Ridge National Laboratory (ORNL), Pacific Northwest National Laboratory (PNNL), and Argon National Laboratory (ANL) as an attempt to develop tools aimed at defining environmental flow needs for hydropower operations. The application of these tools ranges from national to site-specific scales; thus, the utility of each tool will depend on various phases of the environmental flow process. Given the complexity and sheer volume of applications used to determine environmentally acceptable flows for hydropower, a framework is needed to organize efforts into a staged process dependent upon spatial, temporal, and functional attributes. By far, the predominant domain for determining environmental flows related to hydropower is within the Federal Energy Regulatory Commission (FERC) relicensing process. This process can take multiple years and can be very expensive depending on the scale of each hydropower project. The utility of such a framework is that it can expedite the environmental flow process by 1) organizing data and applications to identify predictable relationships between flows and ecology, and 2) suggesting when and where tools should be used in the environmental flow process. In addition to regulatory procedures, a framework should also provide the coordination for a comprehensive research agenda to guide the science of environmental flows. This research program has further reaching benefits than just environmental flow determination by providing modeling applications, data, and geospatial layers to inform potential hydropower development. We address several objectives within this document that highlight the limitations of existing environmental flow paradigms and their applications to hydropower while presenting a new framework catered towards hydropower needs. Herein, we address the following objectives: 1) Provide a brief overview of the Natural Flow Regime paradigm and existing environmental flow frameworks that have been used to determine ecologically sensitive stream flows for hydropower operations. 2) Describe a new conceptual framework to aid in determining flows needed to meet ecological objectives with regard to hydropower operations. The framework is centralized around determining predictable relationships between flow and ecological responses. 3) Provide evidence of how efforts from ORNL, PNNL, and ANL have filled some of the gaps in this broader framework, and suggest how the framework can be used to set the stage for a research agenda for environmental flow.

dams↗

Early age volume changes in metakaolin geopolymers: Insights from molecular simulations and experiments

The early age volume changes occurring during the geopolymerisation reaction are not sufficiently understood yet, due to shortage of experimental data and theoretical models. This work presents new results on chemical and autogenous deformation of sodium-activated geopolymers from metakaolin, focussing on the first 72 h of reaction. The results show that the geopolymers undergo early-age chemical expansion, not shrinkage. A model is proposed to explain the experimental result, leveraging recent advances from molecular simulations. The model predicts how the extent of chemical expansion is controlled by confined water in the molecular structure of the geopolymer. However, despite this underlying chemical expansion, geopolymer samples undergo autogenous shrinkage at the macroscale, which excludes self-desiccation as the origin of autogenous deformation. A better insight is gained by monitoring the kinetics of geopolymerisation using isothermal and differential calorimetry. Two kinetic regimes are identified, with apparent activation energies of approximately 90 kJ/mol and 70 kJ/mol. This suggests that two microscopic mechanisms concur to determine the early-age volume changes of geopolymer pastes.

36 MATERIALS SCIENCE↗

Reduced Order Model to Predict Dispersion of Flammable Refrigerant into a Space

As the HVAC&R industry mobilizes to deploy more low-GWP refrigerants, relevant standards are being continually reviewed and updated. Those include the general safety standards ISO 5149 and ASHRAE 15, and the equipment standards IEC and UL. The standards systematically set the allowable maximum amount of refrigerant that should be used in different equipment types and different applications. To do so, they rely on predictions of how a leaked refrigerant mass will disperse into a space. Dispersion characteristics, such as total flammable volume and its residence time, determine the risk associated with the presence of the flammable refrigerant. The standards have included provisions for the use of flammable refrigerants for approximately two decades. They relied on limited analytical analyses and test cases in their development. Dispersion of a refrigerant into a space is complex. Computational fluid dynamics (CFD) are the most accurate in predicting a given problem. However, CFD is computationally expensive and requires specialized expertise and resources and is not suitable for use by standards development working group as prediction tool. This paper presents the development of a reduced order model (ROM) that predicts the key dispersion characteristics relevant to the dispersion of a leaked refrigerant into a space for any combination of input variables. The inputs are the refrigerant release height, the total released refrigerant mass and its release flow rate, the refrigerant molecular weight, the ventilation flow rate, the floor area and height of the space, recirculation air flow rate, and the tightness of the space. The outputs are histograms of volume fraction of the room in prescribed concentration bins and the total mass of the refrigerant in each bin normalized by the total refrigerant charge at 13 prescribed simulation time stamps between 1 and 900 seconds. The ROM is constructed from a set of CFD simulations with carefully chosen combinations of input parameters. The selection if done using a multidimensional sparse grid which is a generalization of the classical tensor approach but offers additional flexibility and thus can be more carefully tuned towards a specific model. The tuning is done to improve the accuracy, measured in the difference between the output values of the ROM and the CFD model, while minimizing the computational cost, measured in number of CFD simulations which is orders of magnitude more expensive than the processing the training data.

Edwards, Dean↗

Clinical Factors Associated With Seroma Volume Reduction in Breast-Conserving Therapy for Early-Stage Breast Cancer: A Multi-Institutional Analysis

Purpose: To correlate clinical factors with seroma volume and reduction; and to determine whether cone-beam CT (CBCT) could be used clinically to monitor seroma reduction. Patients and Methods: This investigation included 102 women from five institutions with stage T1-2 breast cancer treated with breast-conserving therapy. Two CT scans were acquired: the planning CT (CT1) and a second CT (CT2) during radiotherapy (RT). Seroma was contoured on all scans, and correlations between seroma characteristics and clinical factors were investigated by univariate and multivariate analyses. In a substudy, 10 of the 102 patients received multiple CBCT scans during RT. Seroma were contoured by two observers in the substudy. Fifteen time points at which CT and CBCT were performed within 2 days were identified. The levels of correlation in seroma contours between CBCT and CT and between the two observers were examined. Results: The mean relative seroma reduction from CT1 to CT2 was 54% (p < 0.001). A significant inverse relationship was found between relative seroma reduction per week and number of RT fractions given by univariate and multivariate analyses (p = 0.01, 0.03). The mean difference in contoured seroma volumes between CT and CBCT was 12% (3.3 cm{sup 3}). When assessing the relative difference in seroma contours between Observer 1 and Observer 2, an interobserver difference of 12% was demonstrated. Neither discrepancy was clinically significant. Conclusions: Radiotherapy seems to hinder seroma reduction. Volume discrepancies between CBCT and CT were minor, with low interobserver variation, indicating that CBCT might be useful in monitoring seroma reduction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-155: Automatic Quantitative Decision Making Metric for 4DCT Image Quality

Purpose: To develop a quantitative decision making metric for automatically detecting irregular breathing using a large patient population that received phase-sorted 4DCT. Methods: This study employed two patient cohorts. Cohort#1 contained 256 patients who received a phasesorted 4DCT. Cohort#2 contained 86 patients who received three weekly phase-sorted 4DCT scans. A previously published technique used a single abdominal surrogate to calculate the ratio of extreme inhalation tidal volume to normal inhalation tidal volume, referred to as the κ metric. Since a single surrogate is standard for phase-sorted 4DCT in radiation oncology clinical practice, tidal volume was not quantified. Without tidal volume, the absolute κ metric could not be determined, so a relative κ (κrel) metric was defined based on the measured surrogate amplitude instead of tidal volume. Receiver operator characteristic (ROC) curves were used to quantitatively determine the optimal cutoff value (jk) and efficiency cutoff value (τk) of κrel to automatically identify irregular breathing that would reduce the image quality of phase-sorted 4DCT. Discriminatory accuracy (area under the ROC curve) of κrel was calculated by a trapezoidal numeric integration technique. Results: The discriminatory accuracy of ?rel was found to be 0.746. The key values of jk and tk were calculated to be 1.45 and 1.72 respectively. For values of ?rel such that jk≤κrel≤τk, the decision to reacquire the 4DCT would be at the discretion of the physician. This accounted for only 11.9% of the patients in this study. The magnitude of κrel held consistent over 3 weeks for 73% of the patients in cohort#3. Conclusion: The decision making metric, ?rel, was shown to be an accurate classifier of irregular breathing patients in a large patient population. This work provided an automatic quantitative decision making metric to quickly and accurately assess the extent to which irregular breathing is occurring during phase-sorted 4DCT.

60 APPLIED LIFE SCIENCES↗

Tumor Volume Changes on 1.5 Tesla Endorectal MRI During Neoadjuvant Androgen Suppression Therapy for Higher-Risk Prostate Cancer and Recurrence in Men Treated Using Radiation Therapy Results of the Phase II CALGB 9682 Study

Purpose: We prospectively determined whether the change in tumor volume (TV) during 2 months of neoadjuvant androgen suppression therapy (nAST) measured using conventional 1.5 Tesla endorectal magnetic resonance imaging (eMRI) was associated with the risk of recurrence after radiation (RT) and 6 months of AST. Patients and Methods: Between 1997 and 2001, 180 men with clinical stage T1c-T3cN0M0 adenocarcinoma of the prostate were registered. Fifteen were found to be ineligible and the institutional MR radiologist could not assess the TV in 32, leaving 133 for analysis. Multivariable Cox regression analysis was used to assess whether a significant association existed between eMRI-defined TV progression during nAST and time to recurrence adjusting for prostate-specific antigen (PSA) level, Gleason score (8 to 10 or 7 vs. 6 or less) and stage (T3 vs. T1-2). Results: After a median follow up of 6.7 years and adjusting for known prognostic factors, there was a significant increase in the risk of PSA failure (HR, 2.3 [95% CI, 1.1-4.5; p = 0.025) in men with eMRI-defined TV progression during nAST. Specifically, adjusted estimates of PSA failure were significantly higher (p = 0.032) in men with, compared with men without, eMRI-defined TV progression reaching 38% vs. 19%, respectively, by 5 years. Conclusion: Eradicating intraprostatic hormone refractory prostate cancer (HRPC) by maximizing local control and randomized trials assessing whether survival is improved when agents active against HRPC are combined with maximal local therapy are needed in men who progress based on eMRI during nAST.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of an Inline Urine Monitoring System for the International Space Station

Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

Broyan, James Lee, Jr.↗

Thermodiffusion in concentrated ferrofluids: Experimental and numerical results on magnetic thermodiffusion

Ferrofluids consist of magnetic nanoparticles dispersed in a carrier liquid. Their strong thermodiffusive behaviour, characterised by the Soret coefficient, coupled with the dependency of the fluid's parameters on magnetic fields is dealt with in this work. It is known from former experimental investigations on the one hand that the Soret coefficient itself is magnetic field dependent and on the other hand that the accuracy of the coefficient's experimental determination highly depends on the volume concentration of the fluid. The thermally driven separation of particles and carrier liquid is carried out with a concentrated ferrofluid (φ = 0.087) in a horizontal thermodiffusion cell and is compared to equally detected former measurement data. The temperature gradient (1 K/mm) is applied perpendicular to the separation layer. The magnetic field is either applied parallel or perpendicular to the temperature difference. For three different magnetic field strengths (40 kA/m, 100 kA/m, 320 kA/m) the diffusive separation is detected. It reveals a sign change of the Soret coefficient with rising field strength for both field directions which stands for a change in the direction of motion of the particles. This behaviour contradicts former experimental results with a dilute magnetic fluid, in which a change in the coefficient's sign could only be detected for the parallel setup. An anisotropic behaviour in the current data is measured referring to the intensity of the separation being more intense in the perpendicular position of the magnetic field: S{sub T‖} = −0.152 K{sup −1} and S{sub T⊥} = −0.257 K{sup −1} at H = 320 kA/m. The ferrofluiddynamics-theory (FFD-theory) describes the thermodiffusive processes thermodynamically and a numerical simulation of the fluid's separation depending on the two transport parameters ξ{sub ‖} and ξ{sub ⊥} used within the FFD-theory can be implemented. In the case of a parallel aligned magnetic field, the parameter can be determined to ξ{sub ‖} = (2.8; 9.1; 11.2) × 10{sup −11} · D{sub ‖} kg/(A{sup 2}m) for the different field strengths and in dependence on the magnetic diffusion coefficient D{sub ‖}. An adequate fit in the perpendicular case is not possible, by ξ{sub ⊥} = 1 × 10{sup −17} kg/(Am{sup 2}) a rather good agreement between numerical and experimental data can be found for a field strength of 40 kA/m, a change in the coefficient's sign in the perpendicular setup is not numerically determinable via this theory. The FFD-theory is only partly applicable to calculate the concentration profile in concentrated magnetic fluids established due to a temperature gradient and magnetic field applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗