Solvation-protection-enabled high-voltage electrolyte for lithium metal batteries

To facilitate the practical application of lithium metal batteries (LMBs), stable interfaces between the electrolyte and the lithium metal must be achieved. Herein, we introduce a solvation protection strategy for designing a functional electrolyte for high-voltage LMBs. Fluoroethylene carbonate (FEC) was introduced as a solvation protection solvent for the difluoroethylene carbonate (DFEC)/trifluoroethyl methyl carbonate (FEMC) electrolyte system to enable the cycling of lithium metal anode. The addition of FEC alters the structures of lithium complexes in solution because of its relatively high solvating power. Through the precise control of the solvation number (> 1) of fluorinated cyclic carbonate (i.e., FEC:DFEC > critical ratio), lithium complexes with Li + solvated solely by FEMC, which decompose on the lithium surface to form detrimental by-products, can be effectively eliminated. Here, the new ternary FEC/DFEC/FEMC system not only maintains the beneficial effect of DFEC in forming a robust solid-electrolyte interphase on the lithium anode, but also confers outstanding anodic stability provided by FEMC, while eliminating detrimental FEMC decomposition through the solvation protection effect of FEC. Clearly, this ternary system outperforms the FEC/FEMC and DFEC/FEMC binary systems in facilitating the stable cycling of LMBs.

25 ENERGY STORAGE↗

Quantifying System Strength From Grid-Forming Resources Using Frequency Scan Approach: Preprint

Current industry practices for quantifying the system strength contribution from grid-forming (GFM) resources to ensure stability of power systems dominated by inverter-based resources (IBRs) are primarily based on iterative electromagnetic transient (EMT) time-domain simulation studies. While feasible, these approaches are resource-intensive, lack scalability and intuition, and might not evaluate the system strength contribution over the entire frequency range of interest. This paper introduces a novel, frequency-domain approach to quantify system strength support provided by a GFM resource using frequency scans. The proposed method uses transfer functions from the grid voltage magnitude (V) and phase (?), respectively, to the reactive (Q) and active power (P) output of a GFM resource for quantifying its contribution to system strength. These transfer functions provide a direct measure of the ability of a GFM resource to behave as a stiff voltage source behind a reactance over a specified frequency range, enabling robust quantification of its system strength contribution. The key innovation of this work is the development of a frequency domain system strength metric called the dynamic short-circuit ratio (dSCR) that is suitable for IBR-dominated power systems and is directly related with the familiar short circuit ratio (SCR) metric. The new metric, dSCR, enables the assessment of system strength contributions from both synchronous machines and converter-based GFM resources using a unified benchmark, which is not possible with the traditional SCR metric. The paper also demonstrates how impedance scans could identify if an unstable condition observed during weak grid conditions is a result of the lack active or reactive power support or both. By leveraging the proposed frequency-domain dSCR metric for quantifying system strength contribution from GFM IBRs, the paper demonstrates targeted mitigation strategies for weak grid instabilities without resorting to repeated, time-consuming time-domain simulations. The result is a scalable and efficient approach to remediate stability challenges in power systems with high shares of IBRs and accelerating the integration of GFM technologies for system strength support in power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Incorporating Potassium Citrate to Improve the Performance of Tin‐Lead Perovskite Solar Cells

Abstract Easy‐to‐form tin vacancies at the buried interface of tin‐lead perovskites hinder the performance of low‐bandgap perovskite solar cells (PSCs). Here, a synergistic strategy by incorporating potassium citrate (PC) into the poly(3,4‐ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) hole‐transport layer to passivate the buried interface of Sn‐Pb PSCs is reported. PC neutralizes the acidity of PEDOT:PSS and stabilizes the perovskite front surface, enhancing device stability. Citrate moieties coordinate with Sn 2+ on the buried perovskite surface, preventing Sn 2+ oxidation and suppressing defect formation. Additionally, potassium cations incorporate into Sn‐Pb perovskites, enhancing crystallinity and passivating halide defects. The combined benefits enable efficient low‐bandgap Sn‐Pb PSCs with a power conversion efficiency of 22.7% and a high open‐circuit voltage of 0.894 V. Using this method, 26.1% efficiency for all‐perovskite tandem solar cells is demonstrated. These results emphasize the significance of buried interface passivation in developing efficient and stable Sn‐Pb PSCs and all‐perovskite tandem solar cells.

14 SOLAR ENERGY↗

Lattice-Oxygen-Driven Selective Oxidation Strategy for Stable Argyrodite Solid-State Lithium Metal Batteries

All-solid-state lithium metal batteries (ASSLMBs) with Li6PS5Cl argyrodite electrolytes and high-voltage LiNi0.8Mn0.1Co0.1O2 (NMC811) cathodes offer high energy density but suffer from rapid capacity fading due to the layered-to-rock-salt transition of NMC811 and structural degradation of Li6PS5Cl from parasitic interfacial reactions. Here, we demonstrate a catholyte engineering strategy using a Li2S scavenging additive to suppress interfacial reactivity and preserve the structural and electrochemical stability of both NMC811 and Li6PS5Cl. Incorporating 0.10 wt.% Li2S enables exceptional cycling stability, achieving 76% capacity retention after 550 cycles at C/10 and 88% retention after 800 cycles at C/3 at 60 degrees C, compared with rapid failure in pristine cells. Spectroscopic, electrochemical, and morphological analyses confirm that Li2S maintains electrode integrity by sustaining particle contact and suppressing phase decomposition. This work elucidates interfacial degradation pathways in NMC811/argyrodite systems and introduces a low-cost, scalable strategy to stabilize nickel-rich oxide cathodes in ASSLMBs, advancing their practical viability.

25 ENERGY STORAGE↗

Performance and durability of anion exchange membrane water electrolyzers using down-selected polymer electrolytes

Over the last decade, several stable anion exchange polymer electrolytes have been developed for electrochemical devices. Herein, we investigate how chemical structure and physical properties of polymer electrolytes affect performance and durability of anion exchange membrane water electrolyzers (AEMWEs). We select polymer electrolytes with high alkaline stability and consider their polymer properties including conductivity, mechanical/chemical stability, and material interactions to interpret the performance and durability of AEMWEs. Here, the AEMWE with a poly(phenylene) membrane and a poly(fluorene) ionomeric binder exhibited the best performance among those tested in this study; the AEMWE showed ~1 A cm –2 at 2 V under 1 wt% K 2 CO 3 -fed conditions. The voltage degradation rate was 270–550 μV h –1 for several hundred operating hours at a constant current density of 750 mA cm –2 and a differential pressure of 100 pounds per square inch gauge. Based on these results, we discuss research needs of polymer electrolytes for practical AEMWEs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EMT and Phasor-Domain Co-simulation of a Low Frequency AC Transmission System for Offshore Wind Integration

This work investigates system level interactions of multi-terminal low frequency high-voltage alternating current (LF-HVac) system using back-to back converters and grid-level 60 Hz system. A co-simulation framework by integrating high- fidelity dynamic model of multi-terminal LF-HVac system in electromagnetic transient (EMT) simulation platform and phasor model of IEEE 39 bus system in transient-stability (phasor) program. The co-simulation framework for multi-terminal LF- HVac system with offshore wind integrated in a bulk power system is developed successfully and its steady state and dynamic operation is demonstrated and compared with EMT simulation. The co-simulation results show accurate representation of the dynamic responses with reduced computation burden and time compared to EMT platform.

low-frequency transmission, co-simulation, electro↗

Advanced Distributed Wind Turbine Controls Series: Part 4-Wind Energy in Microgrids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years, the technical capabilities and requirements for distributed wind turbines to provide ancillary services beyond maximum energy production has increased. Ancillary services, leveraged through advanced wind turbine controls, can support grid stability, reliability, and resilience. In the context of a microgrid, wind turbines can provide ancillary services that are useful in both islanded and grid-connected modes, as demonstrated in previous parts of this report series. This report focuses on how wind turbines with advanced controls and power electronics can support the stability of the microgrid during transitions from grid-connected to island mode, and back. This report documents simulation results from a model of the National Renewable Energy Laboratory (NREL) Flatirons Campus containing NREL's 600-kilowatt Controls Advanced Research Turbine. Using this turbine, we demonstrate through desktop simulation how a wind turbine can support the voltage and frequency of a microgrid during transitions - from making planned transitions seamless to keeping all loads online during some unplanned transitions to supporting black start in the event of an open transition (blackout).

17 WIND ENERGY↗

Pathways to the Next-Generation Power System With Inverter-Based Resources: Challenges and recommendations

Managing the stability of today's electric power systems is based on decades of experience with the physical properties and control responses of large synchronous generators. Today's electric power systems are rapidly transitioning toward having an increasing proportion of generation from nontraditional sources, such as wind and solar (among others), as well as energy storage devices, such as batteries. In addition to the variable nature of many renewable generation sources (because of the weather-driven nature of their fuel supply), these newer sources vary in size - from residential-scale rooftop systems to utility-scale power plants - and they are interconnected throughout the electric grid, both from within the distribution system and directly to the high-voltage transmission system. Most important for our purposes, many of these new resources are connected to the power system through power electronic inverters. Collectively, we refer to these sources as inverter-based resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Feedback Compensator Design for Power-Hardware-in-the-Loop System for Medium-Voltage Grid-Connected Power Converters

Hardware-in-the-loop (HIL) evaluation is a method in which the test subject is split into a physical part and a simulated part, and these parts are connected with interfaces to form a combined physical-numerical system. Power-hardware-in-the-loop (PHIL) systems, where actual hardware is connected to a real-time model, can exhibit issues of instability, inaccuracy and errors when operating in a closed-loop. The challenges of generating a PHIL setup are that, first, because of the limited dynamic response of the different parts of the system, the test results might be inaccurate, and, second, because of the high frequency noise introduced by the sensors to the closed-loop system, it can be difficult to design a compensator for the real-time emulator response, while stabilizing the closed-loop system at the same time. In this paper, different parts of a PHIL system are characterized, and the feedback compensator system design is proposed for the stable operation of the closed-loop PHIL system. The issues as observed in a PHIL system without any compensator are demonstrated using experimental results, and the effectiveness of a first order phase lead compensator is validated.

compensator design↗

Electrochemical conversion of methane to ethylene, olefins, and paraffins using metal-supported solid oxide cells

Electrochemical oxidative coupling of methane (E-OCM) with Sr 2 Fe 1·5 Mo 0·5 O 6–δ (SFM) catalyst is demonstrated with metal-supported solid oxide cells (MS-SOC). SFM anode and Pr 6 O 11 cathode catalysts are loaded into a porous symmetric-architecture cell by infiltration and firing. The most effective chelating agent (citric acid/ethyl glycol) and optimal firing/reducing temperatures (850 °C/750 °C) for the SFM catalyst precursor solution are selected and confirmed by cell testing. Operating temperature, cell voltage, and oxygen concentration at the cathode greatly affect the methane conversion rate and product selectivity by controlling the oxygen ion flow. CH 4 conversion of 85.8% is obtained, with C 2 H 4 , C 2 H 6 , and H 2 concentrations of 10.5%, 12.3%, and 25.6% at 800 °C, respectively, in the product exhaust gas. Reasonable stability of the current density and methane conversion is demonstrated during 200 h operation. Furthermore, this research demonstrates technical progress in catalyst and device development for the E-OCM reaction to synthesize valuable chemicals.

30 DIRECT ENERGY CONVERSION↗

Solid-State, Single-Ion Conducting, Polymer Blend Electrolytes with Enhanced Li + Conduction, Electrochemical Stability, and Limiting Current Density

The development of solid-state polymer electrolytes with high lithium conductivity is crucial to improve lithium-ion battery performance and ameliorate the safety challenges associated with current solvent-based electrolytes. Unfortunately, sluggish polymer segmental dynamics are known to constrain conductivity enhancements in solid-state polymer electrolyte systems, limiting overall performance. In this work, a glassy single-ion-conducting polymer, poly[lithium sulfonyl(trifluoromethane sulfonyl)imide methacrylate] (PLiMTFSI), was blended with a flexible polymer, poly(oligo-oxyethylene methyl ether methacrylate) (POEM), and the impact of PLiMTFSI molecular weight and ion concentration on the thermal and ion-conducting behavior of blend electrolytes was investigated. High ionic conductivities approaching 1 × 10 -2 S/cm at 150 °C were realized in this polymer blend electrolyte system as a result of decoupling Li + transport from polymer segmental dynamics. The decoupled ion transport was attributed to the packing frustration of the glassy PLiMTFSI – sufficient percolating free volume was generated to produce effective ion diffusion pathways. This decoupling was tunable as the ion transport could be altered from being closely coupled to the polymer segmental dynamics (Vogel–Tammann–Fulcher-like) to hopping (Arrhenius-like) by increasing the PLiMTFSI molecular weight and ion concentration. Moreover, the immobilized TFSI anion resulted in high Li + selectivity (Li + transference number = 0.9), high electrochemical stability (up to 4.7 V against Li + / Li), and limiting current density of 1.8 mA/cm 2 (electrolyte thickness = 0.05 cm). These features suggest that this single-ion-conducting, polymer blend electrolyte might be a promising alternative to a benchmark system – salt-doped polyethylene oxide. Moreover, the above characteristics can support the battery operation at higher voltages using energy-dense Li metal anodes, with faster charging rates and enhanced energy/power densities. Altogether, the results suggest that polymer chain packing frustration can be exploited to overcome the constraints of slow polymer segmental relaxations to achieve rapid and highly selective ion transport and enhanced performance in solid-state polymer electrolytes.

36 MATERIALS SCIENCE↗

Manipulation of chiral interface states in a moiré quantum anomalous Hall insulator

Moiré systems made from stacked two-dimensional materials host correlated and topological states that can be electrically controlled with applied gate voltages. One prevalent form of topological state that can occur are Chern insulators that display a quantum anomalous Hall effect. Here we manipulate Chern domains in an interaction-driven quantum anomalous Hall insulator made from twisted monolayer–bilayer graphene and observe chiral interface states at the boundary between different domains. By tuning the carrier concentration, we stabilize neighbouring domains of opposite Chern number that then provide topological interfaces devoid of any structural boundaries. This allows the wavefunction of chiral interface states to be directly imaged using a scanning tunnelling microscope. In conclusion, our theoretical analysis confirms the chiral nature of observed interface states and allows us to determine the characteristic length scale of valley polarization reversal across neighbouring Chern domains.

36 MATERIALS SCIENCE↗

Operando identification of site-dependent water oxidation activity on ruthenium dioxide single-crystal surfaces

Understanding the nature of active sites is central to controlling (electro)catalytic activity. Here we employed surface X-ray scattering coupled with density functional theory and surface-enhanced infrared absorption spectroscopy to examine the oxygen evolution reaction on RuO 2 surfaces as a function of voltage. At 1.5 V RHE , our results suggest that there is an –OO group on the coordinatively unsaturated ruthenium (Ru CUS ) site of the (100) surface (and similarly for (110)), but adsorbed oxygen on the Ru CUS site of (101). Density functional theory results indicate that the removal of –OO from the Ru CUS site, which is stabilized by a hydrogen bond to a neighbouring –OH (–OO–H), could be the rate-determining step for (100) (similarly for (110)), where its reduced binding on (100) increased activity. A further reduction in binding energy on the Ru CUS site of (101) resulted in a different rate-determining step (–O + H 2 O – (H + + e - ) → –OO–H) and decreased activity. Our study provides molecular details on the active sites, and the influence of their local coordination environment on activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding Reliability Trade-Offs in 1T-nC and 2T-nC FeRAM Designs

Ferroelectric random access memory (FeRAM) is a promising candidate for energy-efficient nonvolatile memory, particularly for logic-in-memory and compute-in-memory (CIM) applications. Among the available cell architectures, One-Transistor–n-Capacitor (1T-nC) and two-transistor–n-capacitor (2T-nC) FeRAMs each offer distinct trade-offs in density, scalability, and reliability. In this work, we present a comparative study of these two architectures under both dimensional scaling ( XY/Z shrinkage) and vertical integration (increasing stacked capacitors per cell). Using technology computer-aided design (TCAD) and circuit-level simulations, we analyze how scaling impacts ferroelectric capacitance, parasitic coupling, and floating-node (FN) dynamics, which together dictate sense margin (SM) and read stability. A key mitigation strategy—floating unselected capacitors—is applied to both architectures, effectively decoupling the SM from the number of stacked capacitors and enabling tractable analysis across scaling regimes. Results show that 1T-nC suffers more from charge sharing with the bitline (BL), while 2T-nC benefits from transistor isolation and stronger low-voltage sensing at the cost of increased area. By systematically evaluating these behaviors across scaling directions, this work establishes the reliability trade-offs of 1T-nC and 2T-nC cells and provides design guidelines for high-density, vertically integrated FeRAM systems.

1T-nC↗

Modeling Electrokinetics of Oxygen Electrodes in Solid Oxide Electrolyzer Cells

A microscale model is presented in this study to simulate electrode kinetics of the oxygen electrode in a solid oxide electrolyzer cell (SOEC). Two mixed ionic/electronic conducting structures are examined for the oxygen producing electrode in this work: single layer porous lanthanum strontium cobalt ferrite (LSCF), and bilayer LSCF/SCT (strontium cobalt tantalum oxide) structures. A yttrium-stabilized zirconia (YSZ) electrolyte separates the hydrogen and oxygen electrodes, as well as a gadolinium doped-ceria (GDC) buffer layer on the oxygen electrode side. Electrochemical reactions occurring at the two-phase boundaries (2PBs) and three-phase boundaries (3PBs) of single-layer LSCF and bilayer LSCF/SCT oxygen electrodes are modeled under various SOEC voltages with lattice oxygen stoichiometry as the key output. The results reveal that there exists a competition in electrode kinetics between 2PBs and 3PBs, but 3PBs are the primary reactive sites for single-layer LSCF oxygen electrode under high voltages. These locations experience the greatest oxygen stoichiometry variations and are therefore the most likely locations for dimensional changes. By applying an active SCT layer over LSCF, the 2PBs become activated to compete with the 3PBs, thus alleviating oxygen stoichiometry variations and reducing the likelihood of dimensional change. This strategy could reduce lattice structural expansion, proving to be valuable for electrode-electrolyte delamination prevention and will be the focus of future work.

30 DIRECT ENERGY CONVERSION↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability Analysis of Direct Droop-Controlled Grid-Forming Inverter with Current Clipping as Current Limiting Control

This paper investigates the transient stability of the direct droop-controlled grid-forming (GFM) inverter which employs the current clipping-based approach for overcurrent limitation. An equivalent circuit model of the direct-droop GFM inverter with current clipping is developed for this purpose. It is shown that during overcurrent conditions, the GFM inverter with current clipping acts as a voltage source with a virtual resistance behind the inverter filters. To compute the parameters of this virtual resistance an analytical expression is given in the paper. Then utilizing the developed circuit, a criteria to exit current limiting during post-fault conditions is given. The developed analytical approaches are then validated through electromagnetic transient (EMT) simulation results in PSCAD software and finally concluding remarks are drawn.

Mohiuddin, Sheik Mohammad↗