Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation: Preprint

As the modern power systems are experiencing exceptional changes with increasing penetration of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system would obtain high system resilience, by not relying on the bulk power system restoration requiring significant human intervention and procedure to restore. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and start-up behaviors as well as network dynamics. In addition, active involvement of grid-following distributed energy resources (DER) is also studied to facilitate the black start process. It is shown that, by allowing multiple GFM inverters to collectively black start without master-slave coordination, a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Digitally controlled pulse-level discriminator operates over wide voltage range

Low power drain discriminator circuit generates an output pulse when an input pulse exceeds a discrete digitally controlled threshold voltage. The discriminator operates over a wide linear or nonlinear range of threshold levels. It uses several amplifier stages ahead of a fixed-reference threshold detector.

Cancro, C. A.↗

Note: A simple dual polarity dual nanoelectrospray ionization source for ion/ion reactions

A continuously operated dual polarity dual nanoelectrospray ionization source has been constructed and tested. A commercial quadrupole ion trap mass spectrometer was modified to accumulate and trap ions of opposite charge. All changes to the commercial three-dimensional quadrupole ion trap have been made external to the instrument outside of the vacuum system. Few hardware modifications were required because the two emitters send ion beams through the same transmission guides. Computer controlled source voltage polarities are switched quickly and efficiently to transmit one of two continuously generated ion beams. With customized software, this design has proved simple to implement and to operate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wide Bandgap Generation (WBGen): Developing the Future Wide Bandgap Power Electronics Engineering Workforce

This Final Technical Report (FTR) summarizes the work conducted at the Center for Power Electronics Systems (CPES) under the Wide-Bandgap Generation (WBGen) fellowship and traineeship program established by the Advanced Manufacturing and Technologies Office (AMMTO) of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy (EERE) at Virginia Tech, which had as main objective to train the next generation of U.S. citizen power engineers with wide-bandgap (WBG) power semiconductor expertise, with the intent to aid in fulfilling the future workforce needs in this field. The latter was deemed of strategic importance given the fast-paced growth observed—and predicted—in the demand of this technical expertise, whose practitioners have become the enablers and executioners of the electrification transformation process that not just the U.S., but the whole world, is currently undergoing as it seeks for more effective and efficient ways to use energy. As such, the WBGen program set forth to achieve its educational goals, which in addition sought to broaden the range of WBG-based power electronics by conducting research and development on high-efficiency grid apparatus and high-efficiency electrical power systems, and to also enhance the power engineering curriculum by formalizing WBG-oriented design procedures replacing existent yet now obsolete design procedures developed for Silicon (Si) based power electronics. This effort led CPES to spearhead the development of a new major within The Bradley Electrical and Computer Engineering (ECE) Department at Virginia Tech, namely Electronic Power and Energy Systems (EPES), which coalesced power electronics and power systems courses to provide undergraduate students with a strong formation in the power engineering field, while creating a pipeline of graduate students that could pursue the WBG-based curriculum and conduct research at CPES. In all, in what is considered a true success, eight of the twenty WBGen fellows that graduated program were recruited from the ECE department undergraduate cohort. The traineeship emphasized as well, from its beginning, the partnership with industry and national laboratories, which took advantage of the successful industry consortium at CPES that has historically been formed by 80–90 power and energy companies working in close collaboration with the center. This gave WBGen fellows the accessibility and possibility to conduct internships at partner facilities during the summer months, focused solely on the evaluation, testing, and adoption of WBG devices, which were many times tightly related to their respective research work and plans. In addition, WBGen fellows conducted their main research work within the confines of research programs at CPES conducted with these industry partners, providing them with a unique opportunity to develop not just their technical expertise—while advancing their knowledge, but to also learn and practice a slew of skills needed for their professional growth. As such, the fellows tackled a variety of WBG-related research topics, from device reliability and capability aspects as well as packaging and integration, encompassing the use of advanced materials and new structures, current sharing challenges, and insulation systems, to advanced gate-drivers with integrated sensors and protection mechanisms and active current- and voltage-based control, to optimized layouts seeking to maximize the switching and power processing performance of these devices, to power processing solutions adopting Gallium-Nitride (GaN) and Silicon-Carbide (SiC) power semiconductors for a variety of applications; including radiation-hardened converters for space dc distribution systems, direct three-phase ac-to-ac power converters for aerospace systems, dc-ac inverters for automotive traction drives, high-frequency isolated dc-dc battery chargers also for heavy transportation systems, and medium-voltage dc-dc and dc-ac converters for distribution systems and future power grids. The WBGen program ultimately graduated a total of 20 power engineers, all experts on WBG-based power electronics, awarding 18 M.S. and 2 PhD degrees in the process. These fellows, all U.S. citizens, allowed CPES to increase the number of citizens students to 33 % at the peak of the program, as the traineeship made possible the recruitment of talent with more attractive graduate research assistantship (GRA) contracts. Unfortunately, the present U.S. citizen enrollment at CPES has declined back to historic levels—approximately 10 %, as the regular GRA rates are not competitive enough when compared with entry-level industry jobs. In all, WBGen fellows published a total of 7 peer-reviewed journal articles, 44 papers at international technical conferences, made 42 presentations at international technical conferences, and filed 4 invention disclosures and patent applications, which have since then been granted by the U.S. Patent and Trademark Office (USPTO). Their contribution to CPES, Virginia Tech, the United States, and the world, has been significant, and continues to yield results thanks to the exemplary career that the fellows have initiated at many of the partners of the program, which include Wolfspeed, Raytheon Technologies, Infineon, Lockheed Martin, Dominion Energy, Northrop Grumman, Rivian, Aerospace Corporation, Sandia National Laboratory, National Renewable Energy Laboratory, John Hopkins University, and Virginia Tech.

14 SOLAR ENERGY↗

The Challenges of Modeling Distributed Energy Resources (DERs) as Blackstart Resources and for Volt-VAR Optimality

Modeling, testing and instituting Distributed Energy Resources (DERs) as Blackstart Resoucrces presents several challenges due to the fundamental differences between traditional black start resources (e.g., large generators) versus DERs like solar PV systems with battery storage. This paper addresses some of these key challenges. These include intermittency of coordinating DERs to provide continuous power during a black start event, especially during extended periods of cloud cover or when battery energy storage is depleted. This paper additionally addresses the collapsing voltage and stability control challenges specific to maintaining bulk power system stability during black start synchronization These physical and engineering limitations require careful engineering design, modeling and engineering to ensure that DERs can support critical loads and substations during black start events. A variety of additional challenges also exist. Additionally, there are challenges associated with feeder location and low voltage secondary system impacts on DER functions and settings. We compare typical functions and settings for DERs for power factor control and correction. We also demonstrate how voltag control via Volta-VAR power factor correction can be done

Mukherjee, Srijib↗

Advanced Energy Storage Management in Distribution Network

With increasing penetration of distributed generation (DG) in the distribution networks (DN), the secure and optimal operation of DN has become an important concern. In this paper, an iterative mixed integer quadratic constrained quadratic programming model to optimize the operation of a three phase unbalanced distribution system with high penetration of Photovoltaic (PV) panels, DG and energy storage (ES) is developed. The proposed model minimizes not only the operating cost, including fuel cost and purchasing cost, but also voltage deviations and power loss. The optimization model is based on the linearized sensitivity coefficients between state variables (e.g., node voltages) and control variables (e.g., real and reactive power injections of DG and ES). To avoid slow convergence when close to the optimum, a golden search method is introduced to control the step size and accelerate the convergence. The proposed algorithm is demonstrated on modified IEEE 13 nodes test feeders with multiple PV panels, DG and ES. Numerical simulation results validate the proposed algorithm. Various scenarios of system configuration are studied and some critical findings are concluded.

linearization↗

Metal-oxide-semiconductor capacitors and Schottky diodes studied with scanning microwave microscopy at 18 GHz

We measured the DC and RF impedance characteristics of micrometric metal-oxide-semiconductor (MOS) capacitors and Schottky diodes using scanning microwave microscopy (SMM). The SMM consisting of an atomic force microscopy (AFM) interfaced with a vector network analyser (VNA) was used to measure the reflection S11 coefficient of the metallic MOS and Schottky contact pads at 18 GHz as a function of the tip bias voltage. By controlling the SMM biasing conditions, the AFM tip was used to bias the Schottky contacts between reverse and forward mode. In reverse bias direction, the Schottky contacts showed mostly a change in the imaginary part of the admittance while in forward bias direction the change was mostly in the real part of the admittance. Reference MOS capacitors which are next to the Schottky diodes on the same sample were used to calibrate the SMM S11 data and convert it into capacitance values. Calibrated capacitance between 1–10 fF and 1/C{sup 2} spectroscopy curves were acquired on the different Schottky diodes as a function of the DC bias voltage following a linear behavior. Additionally, measurements were done directly with the AFM-tip in contact with the silicon substrate forming a nanoscale Schottky contact. Similar capacitance-voltage curves were obtained but with smaller values (30–300 aF) due to the corresponding smaller AFM-tip diameter. Calibrated capacitance images of both the MOS and Schottky contacts were acquired with nanoscale resolution at different tip-bias voltages.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design Considerations of a Coordinative Demand Charge Mitigation Strategy

This paper presents a coordinative demand charge mitigation (DCM) strategy for reducing electricity consumption during system peak periods. Available DCM resources include batteries, diesel generators, controllable loads, and conservation voltage reduction. All resources are directly controlled by load serving entities. A mixed integer linear programming based energy management algorithm is developed to optimally coordinate of DCM resources considering the load payback effect. To better capture system peak periods, two different kinds of load forecast are used: the day-ahead load forecast and the peak-hour probability forecast. Five DCM strategies are compared for reconciling the discrepancy between the two forecasting results. The DCM strategies are tested using actual utility data. Simulation results show that the proposed algorithm can effectively mitigate the demand charge while preventing the system peak from being shifted to the payback hours. We also identify the diminishing return effect, which can help load serving entities optimize the size of their DCM resources.

Hu, Rongxing↗

Estimating Customer Impact of Volt-Watt Using Only Smart Meter Voltage Data

The autonomous inverter control mode known as volt-watt control can be useful as a backstop against high customer voltages outside of the ranges specified in ANSI C84.1 (i.e. above 1.05-1.06 per unit). Volt-watt control mitigates high voltages by directly reducing the active power output of a distributed energy resource based on local voltage measurements. Therefore volt-watt control also can impact the energy produced by the DER (e.g. PV system), especially for customers with persistently high voltages, and in such cases it is difficult to determine exactly how much the DER has been curtailed because it is not generally known exactly how much energy the PV system could have produced. These slides propose a relatively simple method of estimating the DER's energy curtailment using only data from the utility advanced metering infrastructure (AMI) data). The method proves surprisingly accurate when validated against detailed quasi-static time-series simulations and against limited field data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributionally Robust Decentralized Volt-Var Control With Network Reconfiguration

Here, this paper presents a decentralized volt-var optimization (VVO) and network reconfiguration strategy to address the challenges arising from the growing integration of distributed energy resources, particularly photovoltaic (PV) generation units, in active distribution networks. To reconcile control measures with different time resolutions and empower local control centers to handle intermittency locally, the proposed approach leverages a two-stage distributionally robust optimization; decisions on slow-responding control measures and set points that link neighboring subnetworks are made in advance while considering all plausible distributions of uncertain PV outputs. We present a decomposition algorithm with an acceleration scheme for solving the proposed model. Numerical experiments on the IEEE 123 bus distribution system are given to demonstrate its outstanding out-of-sample performance and computational efficiency, which suggests that the proposed method can effectively localize uncertainty via risk-informed proactive timely decisions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Paschen's curve in microgaps with an electrode surface protrusion

Paschen's curve in microgaps with a hemi-ellipsoidal protrusion on the electrode surface is examined using a two-dimensional fluid model. The breakdown voltage is identified when the discharge enters the subnormal region, according to voltage-current characteristics. It is discovered that the breakdown in a microgap with a surface protrusion on the electrode can result in a combined Paschen's curve, which transits from long-gap (distance between the cathode and anode without the presence of protrusion) behavior at low pressure to short-gap (distance between the protrusion apex to the opposite electrode) behavior at high pressure. As gas pressure decreases, the length of the optimal discharge path increases, automatically moving from the top of the protrusion to its side surface and then to the wider non-protrusion electrode gap. The effects of the protrusion height and radius as well as the discharge polarity on the Paschen's curve are viewed in detail. The effects of the protrusion aspect ratio on field enhancement are also considered. Our report provides insights into the design of microgaps with controlled breakdown voltage across many orders in pressure via engineered electrode morphology.

42 ENGINEERING↗

Cascaded Quadruple Active Bridge Structures for Multilevel DC to Three-Phase AC Conversion

This paper introduces a multilevel architecture comprised of interconnected dc to three-phase ac converter units. To enable series connected operation, each converter unit contains a quadruple active bridge (QAB) converter that provides isolation between the dc side and each of the three ac sides. Since each converter unit transfers dc-side power as constant balanced three-phase power on the ac side, this implies instantaneous input-output power balance and allows elimination of bulk capacitive energy storage. In addition to minimizing required capacitance, the proposed approach simultaneously enables simplified dc-link controllers amenable to decentralized implementation, supports bidirectional power transfer, and exhibits a modular structure to enhance scalability. Isolation provided by the QAB allows a wide range of electrical configurations among multiple units in various dc-ac, ac-dc or ac-ac applications. In this paper, the focus is on series connections on the ac side to emphasize multilevel operation, and the approach is experimentally validated in a dc-ac system containing two cascaded converter units.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chance Constraints for Improving the Security of AC Optimal Power Flow

This paper introduces a scalable method for improving the solutions of ac optimal power flow (AC OPF) with respect to deviations in predicted power injections from wind and other uncertain generation resources. The aim of this paper is on providing solutions that are more robust to short-term deviations, and that optimize both the initial operating point and a parametrized response policy for control during fluctuations. We formulate this as a chance-constrained optimization problem. To obtain a tractable representation of the chance constraints, we introduce a number of modeling assumptions and leverage recent theoretical results to reformulate the problem as a convex, second-order cone program, which is efficiently solvable even for large instances. Our experiments demonstrate that the proposed procedure improves the feasibility and cost performance of the OPF solution, while the additional computation time is on the same magnitude as a single deterministic AC OPF calculation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-C-BRD-03: Analysis of Accelerator Generated Text Logs for Preemptive Maintenance

Purpose: To develop a model to analyze medical accelerator generated parameter and performance data that will provide an early warning of performance degradation and impending component failure. Methods: A robust 6 MV VMAT quality assurance treatment delivery was used to test the constancy of accelerator performance. The generated text log files were decoded and analyzed using statistical process control (SPC) methodology. The text file data is a single snapshot of energy specific and overall systems parameters. A total of 36 system parameters were monitored which include RF generation, electron gun control, energy control, beam uniformity control, DC voltage generation, and cooling systems. The parameters were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and the parameter/system specification. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: the value of 1 standard deviation from the mean operating parameter of 483 TB systems, a small fraction (≤ 5%) of the operating range, or a fraction of the minor fault deviation. Results: There were 34 parameters in which synthetic errors were introduced. There were 2 parameters (radial position steering coil, and positive 24V DC) in which the errors did not exceed the limit of the I/MR chart. The I chart limit was exceeded for all of the remaining parameters (94.2%). The MR chart limit was exceeded in 29 of the 32 parameters (85.3%) in which the I chart limit was exceeded. Conclusion: Statistical process control I/MR evaluation of text log file parameters may be effective in providing an early warning of performance degradation or component failure for digital medical accelerator systems. Research is Supported by Varian Medical Systems, Inc.

07 ISOTOPE AND RADIATION SOURCES↗

Models and methods for assessing the value of HVDC adn MVDC technologies in modern power grids (Annual Report, Executive Summary)

Evolution of today’s predominantly alternating current (ac) transmission grid in to mixed ac transmission – high-voltage direct current (HVdc) systems is expected with the decreasing costs of and advancements in power electronics technologies. The recent technological advancements include the development of more efficient and compact voltage source converters (VSCs) that can provide fast response. Because of their controllability and fast response, HVdc systems provide the ability to enhance reliability of the ac transmission grid through frequency support, voltage control, and congestion relief. The HVdc systems can also provide other ancillary services to enhance the economics and reliability of the ac transmission grids, and to optimize their performance. The tools, models, and methods developed to evaluate their benefits will be key enablers to understanding the value proposition introduced by the fast-acting HVdc systems. The main motivation of this work was to develop models and methods to explore and quantify the technical and economic benefits of HVdc systems and fast response VSC technologies in the future grid of United States. The models and methods explore the benefits of HVdc systems through provision of controlled active/reactive power and fast response. The fast response can provide much-needed multiobjective services to the grid (e.g., frequency response, voltage control) while moving blocks of energy. The models and methods can be applied to study other power electronics technologies and scenarios such as those undertaken in ongoing studies led by the North American Electric Reliability Corporation (NERC) Inverter-based Resource Performance Task Force (IRPTF). The IRPTF studies identify the problems associated with power electronics-based technologies as they are integrated in to the bulk power system (or the ac transmission system).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Load Ensemble Control in Chance-Constrained Optimal Power Flow

Distribution system operators (DSOs) world-wide foresee a rapid roll-out of distributed energy resources. From the system perspective, their reliable and cost effective integration requires accounting for their physical properties in operating tools used by the DSO. This work describes an decomposable approach to leverage the dispatch flexibility of thermostatically controlled loads (TCLs) for operating distribution systems with a high penetration level of photovoltaic resources. Each TCL ensemble is modeled using the Markov Decision Process (MDP). The MDP model is then integrated with a chance constrained optimal power flow that accounts for the uncertainty of PV resources. Since the integrated optimization model cannot be solved efficiently by existing dynamic programming methods or off-the-shelf solvers, this paper proposes an iterative Spatio-Temporal Dual Decomposition algorithm (ST-D2). Finally, we demonstrate the merits of the proposed integrated optimization and ST-D2 algorithm on the IEEE 33-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DC Microgrids Under Denial of Service Attacks: Feasibility and Stability Issues

Distributed control has been extensively studied for a DC microgrid to coordinate multiple grid assets where each asset can generate its own control decisions based on communications within its neighborhood. Nevertheless, such a control strategy usually has a strong dependence on active information exchange and needs to always maintain a pre-determined communication graph. This makes it vulnerable to cyber attacks, especially denial of service (DoS) attacks that block communication channels that effectively change the communication graph. In this paper, we study two potential impacts of DoS attacks: the inability to maintain steady-state and dynamical generation-demand balance, i.e. the feasibility and stability issues. We develop a mathematical model to describe the cyber-induced system steady-state and dynamical performance. The model reveals the impacts of DoS attacks and enables formal analysis. Case studies are shown to verify the proposed work.

41 EE - Solar Energy Technologies Office (EE-4S)↗