Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

912 records · Page 51

Effects of 18 O Exchange on Neutron Emission Rates of Aging 238 PuO 2 LWRHUs

The Lightweight Radioisotope Heater Unit (LWRHU) provides about 1 Watt of thermal power to critical electrical and mechanical systems in the extreme temperatures of space, maintaining the operating temperature of the spacecraft’s scientific and general operating equipment. Los Alamos National Laboratory (LANL) designed and tested the LWRHU in the 1970s through early 1980s. The first production campaign at LANL was in the early 1980s in support of the Galileo mission in which over 100 LWRHUs were manufactured. In the mid-1990s, almost 200 LWRHUs were manufactured in support of the Cassini mission. After the primary Cassini manufacturing campaign, the Department of Energy (DOE) approved the fabrication of more than 10 additional LWRHUs as spares in 1998. The LWRHU assembly contains the following components: a fuel pellet, a vented capsule, a pyrolytic graphite insulator, and a fine-weave pierced fabric (FWPF) graphite aeroshell. The fuel pellet is a hot-pressed 238 PuO 2 cylindrical pellet that is sintered to create a ceramic pellet. The pellet is encapsulated in a platinum-rhodium encapsulation. The welded fueled clad is placed inside a pyrolytic graphite thermal insulation to protect the fuel from the heat produced in reentry events. The exterior layer of the LWRHU assembly is the FWPF aeroshell. Before sintering, PuO 2 granules are heated in a furnace at temperatures greater than or equal to 700°C under an enriched 16 O atmosphere in order to reduce trace quantities of 18 O. Because 18 O undergoes an (α,n) reaction, 18 O needs to be removed as much as possible to meet radiation emission requirements set by the Jet Propulsion Laboratory (JPL) and the National Aeronautics and Space Administration (NASA), as well as other agencies. The relative abundances of the oxygen isotopes are indicated by neutron emission rate (NER) measurements. LWRHUs are vented with a sintered platinum frit vent (George 1986). During extraterrestrial operation, the vent in the cladding allows helium from the decay of plutonium to escape and relieves pressure from the system while preventing the solids from escaping (Rinehart 1996, Tate 1982 & 1985). This vent is protected during manufacture by a platinum-30 rhodium cover. The capsule vent is activated by milling a 0.025-inch diameter hole through the protective cover to a nominal depth of 0.015 inches, generally immediately before the LWRHU is loaded into the aeroshell (George 1986). Prior to long-term storage, LWRHUs are vented and thus potentially allow infiltration of 18 O from the ambient atmosphere. Although NER decreases with age due to the reduction in emitted alpha particles, it might be expected that NER reduction is mitigated by the exchange of 18 O. However, this is not necessarily the case and no trend was observed relating NER to age other than the natural decay of 238 Pu (Mulford 2021). The most probable and dominant factor for determining specific NER was manufacturing discrepancies between individual units. It is important to understand the lack of observed 16 O- 18 O exchange and to compare LWRHU pellets as much as possible.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In Situ Wind and Turbulence Measurements in a Field of Full-Size Parabolic Trough Collectors

Concentrated Solar Power (CSP) is a promising method for using Solar power for electricity generation with thermal energy storage. One of the primary drivers of structural design costs of CSP collector structures is wind loading. To date, the design of these structures has relied on data from wind tunnels that do not adequately capture the dynamic effects observed at scale. NREL initiated a field measurement campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs, providing insights on structural dynamic response, and generating a first-of-a-kind, comprehensive, high-resolution wind-loading dataset available for validating simulations of wind loading on collector structures. The measurements at NSO consist of Sonic anemometers on masts at different heights to characterize the incoming flow and conditions within and above the trough field, in combination with a Doppler Lidar scanning the horizontal plane above the troughs. The wind measurements at NSO have been continuously operating since October 2021 and provide a year-long dataset characterizing wind and turbulence conditions. The structural load measurements start in November 2022 and will complement the wind measurements. In this poster, we present first results of the wind measurement campaign by highlighting days with different atmospheric flow conditions. We identified three main factors altering the flow over the parabolic troughs: Wind speed, wind direction, and the angle of the parabolic troughs. The highest loads are expected when the wind blows perpendicular to the trough rows. In this case, the first rows experience the highest loads and block the subsequent rows, creating conditions with decreased wind speed and enhanced turbulence within the trough field. Also, turbulent length scales change. These affected conditions produce unique load cases on the structures that will be captured by the load measurements. If the wind blows along the trough rows, wind and turbulence conditions are less influenced by the troughs.

concentrated solar power↗

Quality concerns caused by quality control — deformation of silicon strip detector modules in thermal cycling tests

The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35 °C (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector's operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35 °C and +40 °C are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure.

47 OTHER INSTRUMENTATION↗

Dynamically tunable membrane metasurfaces for infrared spectroscopy and strong light-matter interactions

Mid-infrared spectroscopy enables biochemical sensing by identifying vibrational molecular fingerprints, but it faces limitations in instrumentation portability and analytical sensitivity. Optical metasurfaces with strong mid-infrared photonic resonances provide an attractive solution towards on-chip spectrometry and sensitive molecular detection, yet their static nature hinders their anticipated impact. Here, we introduce and demonstrate dynamically tunable silicon membrane metasurfaces exhibiting high-Q transmissive resonances in the fingerprint region. By harnessing silicon’s thermo-optical properties, we achieve continuous modulation of coupling-induced transparency (CIT) modes that emerge upon the interference of quasi-bound states in the continuum (q-BICs) and surface lattice modes (SLMs). We measure a spectral tuning rate of 0.06 cm −1 K −1 by continuously sweeping the sharp CIT resonances over a 23.5 cm −1 spectral range across a temperature range of 300–700 K. In the current proof‑of‑concept implementation, the dynamic transmission control enables non-contact chemical analysis of polymer films by detecting characteristic absorption bands of polystyrene (1450 and 1492 cm −1 ) and poly(methyl methacrylate) (1730 cm −1 ) without requiring conventional spectrometers. When analyte molecules fill the metasurface-generated photonic cavities, we demonstrate vibrational strong coupling between the poly(methyl methacrylate)’s carbonyl band and the CIT mode, manifested in a Rabi splitting of ~43 cm −1 . Our results establish a new photonic platform that unites spectral precision, strong field enhancement, and reconfigurability, offering diverse potential for compact mid-infrared spectroscopy, molecular sensing, and programmable polaritonic photonics.

74 ATOMIC AND MOLECULAR PHYSICS↗

First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Technology Maturation of Wireless Harsh Environment Sensors For Improved Condition Based Monitoring Of Coal Fired Power Generation

The overall goal of this project was to demonstrate and develop the usage of high-temperature (HT) harsh-environment (HE) wireless surface acoustic wave resonator (SAWR) sensor technology to promote reliable maintenance through condition-based maintenance (CBM) for field applications in harsh service conditions associated with power plant environments. The project aimed to advance the HT HE wireless SAWR sensor technology from TRL 5 to TRL 7. In addition to HT HE wireless temperature sensing, efforts were dedicated during this project to investigate, develop and increase the TRL from 3 to 5 for the following technologies: (a) HT HE strain sensors to address additional CBM monitoring needs, such as boiler tube mechanical / thermal stresses, which can provide early indications for boiler tube cracking and failure; and (b) HT aluminum nitride (AlN) and scandium aluminum nitride (ScAlN) based piezoelectric thin film fabrication and implementation of SAW sensors, with the goal of releasing the need to use single crystal piezoelectric materials for SAWRs and thus broaden possible technology applications to non-planar and harder to modify surfaces. To achieve the goals mentioned above, UMaine and its partner, Environetix Technologies Corporation, established partnerships with the following power plants: Longview Power (Maidsville, WV), a coal-fired power plant; Penobscot Energy Recovery Corp (PERC, Orrington, ME), a waste-to-energy power plant; and the UMaine Steam Plant (Orono, ME), an oil / natural gas power plant. To realize wireless HT HE SAWR sensor systems in these harsh service conditions, the University of Maine research team worked with Environetix and these power plants to define, design, fabricate, test and validate a mature prototype wireless temperature SAWR sensor system for boiler tube applications within the HT HE of the reheater pass damper chamber to directly and wirelessly monitor the temperature at eighteen independent boiler tube locations. The system included three levels, or “tiers”, of wireless communication to enable remote monitoring: Tier 1, the wireless link in the reheater pass damper chamber directly accessing the sensors on the boilers; Tier 2, the wireless local area network link, transmitting processed sensor information within the power plant to the Tier 3, a commercial wireless signal carrier company for secure remote data monitoring outside of the power plant. Regarding the wireless sensor system installed at Longview Power, temperature information from the boilers was continuously transmitted from the Longview boilers at Maidsville, WV, to Environetix headquarters, Orono, ME, over a 34 month period, when the system was finally decommissioned. Strain sensors and piezoelectric ScAlN thin film sensors were successfully installed on the exhaust duct at the UMaine Steam Power plant. The advances in wireless strain sensors and thin film piezoelectric film fabrication and testing were performed mostly in UMaine laboratories and field tested at the UMaine Steam Plant, due to its close proximity to UMaine/Environetix, access to the plant facility, and due to difficulties in accessing the other power plants during the COVID shut-down period. The project accomplished the TRL level increase of the targeted CBM technologies through the successful fabrication, installation, test, and validation of dedicated and commercial wireless sensor systems, utilizing the three different power plants. The outcomes of this project, including the wireless sensor data capability, are expected to yield an advance for CBM in harsh power plant environments. The reduction of maintenance costs, improved safety during plant operation, and increased power plant efficiency will lead to increased revenues (i.e., fewer forced outages) due to better process monitoring enabled by the wireless HT HE SAWR temperature sensor technology.

20 FOSSIL-FUELED POWER PLANTS↗

Multiwavelength Observations of the Blazar VER J0521+211 during an Elevated TeV Gamma-Ray State

We report on a long-lasting, elevated gamma-ray flux state from VER J0521+211 observed by VERITAS, MAGIC, and Fermi-LAT in 2013 and 2014. The peak integral flux above 200 GeV measured with the nightly binned light curve is (8.8 ± 0.4) × 10 –7 photons m –2 s –1 , or ~37% of the Crab Nebula flux. Multiwavelength observations from X-ray, UV, and optical instruments are also presented. A moderate correlation between the X-ray and TeV gamma-ray fluxes was observed, and the X-ray spectrum appeared harder when the flux was higher. Using the gamma-ray spectrum and four models of the extragalactic background light (EBL), a conservative 95% confidence upper limit on the redshift of the source was found to be z ≤ 0.31. Unlike the gamma-ray and X-ray bands, the optical flux did not increase significantly during the studied period compared to the archival low-state flux. The spectral variability from optical to X-ray bands suggests that the synchrotron peak of the spectral energy distribution (SED) may become broader during flaring states, which can be adequately described with a one-zone synchrotron self-Compton model varying the high-energy end of the underlying particle spectrum. The synchrotron peak frequency of the SED and the radio morphology of the jet from the MOJAVE program are consistent with the source being an intermediate-frequency-peaked BL Lac object.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of the correlation patterns and the Compton dominance variability of Mrk 421 in 2017

We present a detailed characterisation and theoretical interpretation of the broadband emission of the paradigmatic TeV blazar Mrk 421, with a special focus on the multi-band flux correlations. The dataset has been collected through an extensive multi-wavelength campaign organised between 2016 December and 2017 June. The instruments involved are MAGIC, FACT, Fermi-LAT, Swift, GASP-WEBT, OVRO, Medicina, and Metsähovi. Additionally, four deep exposures (several hours long) with simultaneous MAGIC and NuSTAR observations allowed a precise measurement of the falling segments of the two spectral components. The very-high-energy (VHE; E> 100 GeV) gamma rays and X-rays are positively correlated at zero time lag, but the strength and characteristics of the correlation change substantially across the various energy bands probed. The VHE versus X-ray fluxes follow different patterns, partly due to substantial changes in the Compton dominance for a few days without a simultaneous increase in the X-ray flux (i.e., orphan gamma-ray activity). Studying the broadband spectral energy distribution (SED) during the days including NuSTAR observations, we show that these changes can be explained within a one-zone leptonic model with a blob that increases its size over time. The peak frequency of the synchrotron bump varies by two orders of magnitude throughout the campaign. Our multi-band correlation study also hints at an anti-correlation between UV-optical and X-ray at a significance higher than 3σ. A VHE flare observed on MJD 57788 (2017 February 4) shows gamma-ray variability on multi-hour timescales, with a factor ten increase in the TeV flux but only a moderate increase in the keV flux. The related broadband SED is better described by a two-zone leptonic scenario rather than by a one-zone scenario. We find that the flare can be produced by the appearance of a compact second blob populated by high energetic electrons spanning a narrow range of Lorentz factors, from γ' min =2x10 4 to γ' max =6x10 5 .

79 ASTRONOMY AND ASTROPHYSICS↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Tracking Radioactive Isotopes in HVAC and Application for Hot Cell Analyses - 20155

In recent years, the surge in the number of isotope production facilities under design has increased the need to analyze isotope migration in facility Heating, Ventilation, and Air Conditioning (HVAC) during normal operations and accident scenarios. These facilities are used to produce isotopes for medical, security, and industrial applications and as such are subject to license and regulatory requirements 10CFR20, 10CFR30, 10CFR50, and 10CFR70. GOTHIC, a general-purpose thermal-hydraulics software package, includes the ability to model isotopic tracers, radioactive decay and isotope migration as well as HEPA and charcoal filters for isotope retention. A GOTHIC model was developed by Zachry Nuclear Engineering (ZNE) to examine the effect of negative room pressure, HEPA filtration, and HVAC fluctuations on radiation areas, hot cells and gloveboxes. Radioactive tracers were used to simulate the concentration of spills within contaminated areas, track the migration of isotopes of interest, and determine the isotopic retention and buildup on facility HEPA filters. A variety of isotopes with concern to dose (e.g., Kr-85, Sr-90, I-131, etc.), including their decay and progeny, are included in the analysis. Negative pressures are maintained in the regions of interest by a representative central HVAC system equipped with a volumetric fan that exhausts to the environment after a series of isolation valves and HEPA filters. GOTHIC is an industry trusted tool for providing engineering solutions for a variety of applications, including fission product tracking, aerosol and particulate transport and ventilation assessments. The software provides an integrated analysis environment that includes a graphical user interface (GUI) for constructing analysis models, a numerical solver that includes parallel processing capabilities and a post-processor for evaluating simulation results. It solves the conservation equations for mass, momentum and energy for multicomponent, multi-phase flow in lumped parameter and multi-dimensional geometries (1, 2, or full 3D), including the effects of turbulence, diffusion and buoyancy. It has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B and applicable portions of ASME NQA-1 since 1995. GOTHIC has been used for assessing both forced and natural convection conditions for a wide range of applications, including: - Tracking concentration of hazardous gases and chemicals for habitability and safety assessments - Determining ventilation and filtration requirements and optimizing location and arrangement of these systems - Room heat-up, including diverse and Flexible coping strategies for Extended Loss of AC Power (FLEX/ELAP) - Equipment Qualification (EQ) A distinctive feature of GOTHIC is the ability to track many different fields/substances in a simulation, including user defined tracer elements, in the liquid, vapor and droplet fields as well as surfaces and filters. This capability allows GOTHIC to model fission product transport and release or the removal of particulates or harmful toxins from exhaust gases using a spray scrubber or other types of filtration systems. GOTHIC also includes models for engineered equipment, such as fans, filters, charcoal filters, dryers/demisters, dampers, etc. The aerosols and other filtered material are removed or accumulated in these components. The range of aerosol and radiological applications that GOTHIC has been used for includes: - Source Term: Primary Coolant (Equilibrium) Activity; Non-Water Coolant Source/Leakage. - Conditions for Iodine Re-evolution: Sump/Suppression Pool Conditions and pH; - RWST Conditions and pH. - Isotope Removal Mechanisms: Containment Sprayed and Unsprayed Region Mixing; Charcoal Filter Heating due to Iodine decay. - Radionuclide Transport and Decay: Post-LOCA Release in containment; Transport between connected Compartments and vent systems; Groundwater transport of radionuclides. - Non-Newtonian Fluid modeling for sludge, waste tanks, etc. ADAMS ML071581053 (titled 'Best Practice Guidelines for the use of CFD in Nuclear Reactor Safety Applications') poses guidelines for applying single phase CFD codes in nuclear reactor safety problems and GOTHIC is listed as a 'tool for 3D flows' and 'dispersal and deposition of radionuclides.' The Nuclear Quality Assurance (NQA) pedigree of GOTHIC is an important aspect for applications in the nuclear industry. The fundamental tracer models (convective transport, molecular and turbulent diffusion, removal mechanisms, etc.) have been verified using analytical solutions and validated against applicable separate effects tests. Also, GOTHIC has been benchmarked to many integrated effects tests, including Phebus FP (Fission Product). GOTHIC gives good agreement for the buildup and decay of fission products in Phebus Test 3. The model developed by ZNE demonstrates GOTHIC's applicability and acceptability for use in analyzing the migration and retention of radioactive isotopes and their progeny in normal operation and accident scenario analyses for isotope production facilities, hot cells, and gloveboxes. The tracer activities calculated by GOTHIC can then be used in downstream radiation transport and shielding codes like RADTRAD-NAI{sup C}, MCNP{sup R}, and MicroShield{sup R} to determine on-site and of-site doses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of 100 Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li 2 MoO 4 crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of Li 2 MoO 4 cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a Li 2 MoO 4 light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗