Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

The Integrated Sensor System Data Enhancement Package

The purpose of the Integrated Sensor System (ISS) Data Enhancement Package (DEP) is to improve the accuracies of the data obtained from the inflight tests performed on aircraft. The DEP is a microprocessor-based, flight-qualified electronics package that assimilates data from a Ring Laser Gyro (RGL) system, a standard NASA air data package, and other inputs. The DEP then processes these inputs in real-time to obtain optimal estimates of the aircraft velocity, attitude, and altitude. These estimates can be passed to the flight crew, downlinked, and/or stored on a mass storage medium. The DEP is now being built for the NASA Dryden Flight Research Center. Completion is anticipated in early 1984. A primary use of the ISS/DEP will be for the collection of quality data for the estimation of aircraft aerodynamic coefficients, including stability derivatives, using system identification methods. Initial anticipated applications will be on the AV-8B, F-14, and X-29 test aircraft.

Trankle, T. L.↗

Direct Nonlinear Approximation for Security Region Boundary of Integrated Energy Systems: A Polynomial Chaos Expansion Solution

The strong interdependence of electricity, gas, and heating systems can facilitate fault propagation within integrated energy systems (IESs), posing significant challenges to secure operation. This paper proposes a polynomial chaos expansion (PCE)-based approximation method to accurately characterize the IES security region boundary (IES–SRB). By integrating the Karush-Kuhn-Tucker conditions with PCE theory, the IES-SRB approximation problem is reformulated as a set of nonlinear equations concerning the approximation coefficients. Using the Galerkin projection method, these equations are further transformed into a system of projection equations that govern the polynomial approximation coefficients in the IES-SRB approximation. To reduce computational complexity while maintaining high approximation accuracy, a piecewise polynomial approximation method is proposed. Numerical studies on the E39-G20-H6 and E118-G96-H52 IES test systems demonstrate that the proposed method can accurately and effectively construct IES security regions.

Wu, Chenghao [Northeast Electric Power University]↗

Hydrogen Based Energy Storage System for Integration with Dispatchable Power Generator (Phase I Feasibility Study)

This project examined the feasibility of integrating hydrogen generation, storage, and use as a means to decarbonize campus activities while retaining the ability to utilize the existing natural gas fired combined heat and power system installed at the campus of the University of California @ Irvine. Analysis of specific potential sites for the integrated system identified a location adjacent to the existing central plant which resulted in minimization of interconnections. A strategy based on use of commercial electrolyzers and gas storage was identified. Primary technology advancements are required for the gas turbine to accommodate higher levels of hydrogen and the integrated controls. The project indicated challenges for adopting the proposed strategy with the present rates and constraints. The availability of a relatively low-cost biogas resource by the campus already decarbonizes the gas turbine to some extent. In the absence of this resource, procurement of electricity directly from large scale renewable operations could facilitate lower electricity costs. Additional solar resources on campus could also help in this regard. The gas turbine cannot be operated below 50% capacity due to air permit constraints. Using the otherwise curtailed gas turbine operation to generate hydrogen via electrolysis by consuming natural gas is not highly efficient and therefore leads to relatively high costs of electricity returned. Several scenarios demonstrate potential for effective decarbonization, yet most involve lower and lower capacity factor for the legacy gas turbine which is not a good use of the asset. A small gas turbine output with higher efficiency operation would help. As would ability to export electricity to the grid. Certainly current rate structures and operational scenarios are less attractive than other possible future structures which should be pushed for in the future.

03 NATURAL GAS↗

Digital Real-Time Simulation and Power Quality Analysis of a Hydrogen-Generating Nuclear-Renewable Integrated Energy System

This paper investigates the challenges and solutions associated with integrating a hydrogen-generating nuclear-renewable integrated energy system (NR-IES) under a transactive energy framework. The proposed system directs excess nuclear power to hydrogen production during periods of low grid demand while utilizing renewables to maintain grid stability. Using digital real-time simulation (DRTS) in the Typhoon HIL 404 model, the dynamic interactions between nuclear power plants, electrolyzers, and power grids are analyzed to mitigate issues such as harmonic distortion, power quality degradation, and low power factor caused by large non-linear loads. A three-phase power conversion system is modeled using the Typhoon HIL 404 model and includes a generator, a variable load, an electrolyzer, and power filters. Active harmonic filters (AHFs) and hybrid active power filters (HAPFs) are implemented to address harmonic mitigation and reactive power compensation. The results reveal that the HAPF topology effectively balances cost efficiency and performance and significantly reduces active filter current requirements compared to AHF-only systems. During maximum electrolyzer operation at 4 MW, the grid frequency dropped below 59.3 Hz without filtering; however, the implementation of power filters successfully restored the frequency to 59.9 Hz, demonstrating its effectiveness in maintaining grid stability. Future work will focus on integrating a deep reinforcement learning (DRL) framework with real-time simulation and optimizing real-time power dispatch, thus enabling a scalable, efficient NR-IES for sustainable energy markets.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tailoring of NASA-STD-3001 to Lunar Gateway Program Requirements

The Gateway Program must meet NASA's Agency-level human rating requirements, which are intended to accommodate human capabilities and limitations while protecting the safety of the crew, and providing to the maximum extent practical, the capability to safely recover the crew from hazardous situations. Human systems integration represents a key human rating component of Moon to Mars systems to support the execution of Artemis missions, including compliance with mandatory standards for Health and Medical, Safety and Mission Assurance, and Engineering. The human system requirements, together with the human systems integration plan, medical operations requirements, and Gateway sub-system specifications, represent the flow-down of NASA Health and Medical Standards (NASA-STD-3001, Volumes 1 and 2) into the Gateway system. This paper discusses how these documents and other human systems integration activities provide full consideration of human capabilities and limitations as part of the total system design trade space, serving as an example on how the human must be effectively integrated as part of the system in order to achieve mission success. At a bigger scale, the paper con-tributes to the application of systems engineering standards to cutting-edge space exploration initiatives and to the dialogue on how systems engineering can continue to evolve to meet the needs of such ambitious projects.

Systems engineering↗

Optimal operations of a nuclear-based integrated energy system: A mixed integer program approach

A nuclear-based integrated energy system (IES), consisting of multiple carbon-free energy generation and conversion technologies to meet heterogeneous end-use demands, offers a promising approach to decarbonizing the U.S. economy. Operating such an IES is challenging due to its complexity and the diverse end-use demands, such as heating and electricity. This paper aims to address the optimal operation of an IES composed of a small modular reactor (SMR), a steam manifold, a balance of plant (BOP), a high-temperature steam electrolysis (HTSE) system, a district heating (DH) network, and electrical grids. We formulate the system’s operation as a mixed integer linear programming (MILP) problem to maximize net revenues from sales of electricity and hydrogen. To evaluate the efficacy of the proposed model, we conduct a 24-hour simulation considering day-ahead (DA) electricity prices from CAISO and a varying DH demand profile with hourly resolution. The simulation results show that our model effectively optimizes the operation by selling electricity during on-peak periods and purchasing electricity for hydrogen production during off-peak periods, while satisfying operating constraints within the IES.

08 HYDROGEN↗

Max Launch Abort System (MLAS) Pad Abort Test Vehicle (PATV) II Attitude Control System (ACS) Integration and Pressurization Subsystem Dynamic Random Vibration Analysis

In order to mitigate catastrophic failures on future generation space vehicles, engineers at the National Aeronautics and Space Administration have begun to integrate a novel crew abort systems that could pull a crew module away in case of an emergency at the launch pad or during ascent. The Max Launch Abort System (MLAS) is a recent test vehicle that was designed as an alternative to the baseline Orion Launch Abort System (LAS) to demonstrate the performance of a "tower-less" LAS configuration under abort conditions. The MLAS II test vehicle will execute a propulsive coast stabilization maneuver during abort to control the vehicles trajectory and thrust. To accomplish this, the spacecraft will integrate an Attitude Control System (ACS) with eight hypergolic monomethyl hydrazine liquid propulsion engines that are capable of operating in a quick pulsing mode. Two main elements of the ACS include a propellant distribution subsystem and a pressurization subsystem to regulate the flow of pressurized gas to the propellant tanks and the engines. The CAD assembly of the Attitude Control System (ACS) was configured and integrated into the Launch Abort Vehicle (LAV) design. A dynamic random vibration analysis was conducted on the Main Propulsion System (MPS) helium pressurization panels to assess the response of the panel and its components under increased gravitational acceleration loads during flight. The results indicated that the panels fundamental and natural frequencies were farther from the maximum Acceleration Spectral Density (ASD) vibrations which were in the range of 150-300 Hz. These values will direct how the components will be packaged in the vehicle to reduce the effects high gravitational loads.

Ekrami, Yasamin↗

Exploration Life Support Critical Questions for Future Human Space Missions

Exploration Life Support (ELS) is a current project under NASA's Exploration Systems Mission Directorate. The ELS Project plans, coordinates and implements the development of advanced life support technologies for human exploration missions in space. Recent work has focused on closed loop atmosphere and water systems for long duration missions, including habitats and pressurized rovers. But, what are the critical questions facing life support system developers for these and other future human missions? This paper explores those questions and how progress in the development of ELS technologies can help answer them. The ELS Project includes the following Elements: Atmosphere Revitalization Systems, Water Recovery Systems, Waste Management Systems, Habitation Engineering, Systems Integration, Modeling and Analysis, and Validation and Testing, which includes the Sub-Elements Flight Experiments and Integrated Testing. Systems engineering analysis by ELS seeks to optimize overall mission architectures by considering all the internal and external interfaces of the life support system and the potential for reduction or reuse of commodities. In particular, various sources and sinks of water and oxygen are considered along with the implications on loop closure and the resulting launch mass requirements. Systems analysis will be validated through the data gathered from integrated testing, which will demonstrate the interfaces of a closed loop life support system. By applying a systematic process for defining, sorting and answering critical life support questions, the ELS project is preparing for a variety of future human space missions

Kwert, Michael K.↗

Constellation Program (CxP) Crew Exploration Vehicle (CEV) Project Integrated Landing System

Crew Exploration Vehicle (CEV) Chief Engineer requested a risk comparison of the Integrated Landing System design developed by NASA and the design developed by Contractor- referred to as the LM 604 baseline. Based on the results of this risk comparison, the CEV Chief engineer requested that the NESC evaluate identified risks and develop strategies for their reduction or mitigation. The assessment progressed in two phases. A brief Phase I analysis was performed by the Water versus Land-Landing Team to compare the CEV Integrated Landing System proposed by the Contractor against the NASA TS-LRS001 baseline with respect to risk. A phase II effort examined the areas of critical importance to the overall landing risk, evaluating risk to the crew and to the CEV Crew Module (CM) during a nominal land-landing. The findings of the assessment are contained in this report.

Baker, John D.↗

Shuttle payload integration - Contamination aspects

As part of the development of the Space Shuttle, a payload integration system has been established. This integration system or process encompasses several technical disciplines, one of which is concerned with the control of molecular and particulate contamination. Specific integration procedures and documentation have evolved that reflect the incorporation of payload/Space Transportation System contamination requirements and capabilities. Of the 38 payloads in the payload integration system currently, about 20% are considered sensitive to contamination in that special precautions must be taken to ensure that contamination from the Space Shuttle Orbiter does not impair payload function. Most of these payload requirements have been satisfied by the incorporation of controlled ground operations discipline and installation of a payload bay liner, which isolates the payload from the Orbiter systems. Some payloads, however, provide covers for sensitive payload instrumentation.

Jacobs, S.↗

An innovative heterogeneous transfer learning framework to enhance the scalability of deep reinforcement learning controllers in buildings with integrated energy systems

Deep Reinforcement Learning (DRL)-based control shows enhanced performance in the management of integrated energy systems when compared with Rule-Based Controllers (RBCs), but it still lacks scalability and generalisation due to the necessity of using tailored models for the training process. Transfer Learning (TL) is a potential solution to address this limitation. However, existing TL applications in building control have been mostly tested among buildings with similar features, not addressing the need to scale up advanced control in real-world scenarios with diverse energy systems. This paper assesses the performance of an online heterogeneous TL strategy, comparing it with RBC and offline and online DRL controllers in a simulation setup using EnergyPlus and Python. The study tests the transfer in both transductive and inductive settings of a DRL policy designed to manage a chiller coupled with a Thermal Energy Storage (TES). The control policy is pre-trained on a source building and transferred to various target buildings characterised by an integrated energy system including photovoltaic and battery energy storage systems, different building envelope features, occupancy schedule and boundary conditions (e.g., weather and price signal). The TL approach incorporates model slicing, imitation learning and fine-tuning to handle diverse state spaces and reward functions between source and target buildings. Results show that the proposed methodology leads to a reduction of 10% in electricity cost and between 10% and 40% in the mean value of the daily average temperature violation rate compared to RBC and online DRL controllers. Moreover, online TL maximises self-sufficiency and self-consumption by 9% and 11% with respect to RBC. Conversely, online TL achieves worse performance compared to offline DRL in either transductive or inductive settings. However, offline Deep Reinforcement Learning (DRL) agents should be trained at least for 15 episodes to reach the same level of performance as the online TL. Therefore, the proposed online TL methodology is effective, completely model-free and it can be directly implemented in real buildings with satisfying performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Impact of Price-Responsive Load on Power Systems Using Integrated T&D Simulation

This paper explores the differences between simulating price-responsive load (PRL) interactions with power systems using integrated transmission and distribution (T&D) models and transmission-only (T-only) models. This analysis uses the Integrated Grid Modeling System (IGMS) software to capture 'ISO-to-appliance' simulations using a synthetic T&D model built on the PJM 5-Bus transmission network with multiple full-scale taxonomy feeders that include physics-based models of thousands of customers and PRLs. The results show important differences in the impacts of PRLs between integrated T&D and T-only models. Experiments with the synthetic integrated T&D dataset demonstrated that integrated T&D simulation revealed notably larger differences between the PRL and no-PRL cases for load, and prices compared to T-only simulation. Similarly, differences are observed between the price response of individual buildings and distribution feeders and the corresponding transmission bus in the integrated T&D simulations, which are difficult to capture in traditional T-only simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Desalination Multi-Effect Evaporator Models in Support of Integrated Energy Systems

The purpose of this work is to contribute to the Integrated Energy Systems (IES) modeling efforts from the Department of Energy with Idaho National Laboratory. The DOE is working on a plug-and-play set of models in an open-source repository called HYBRID that can be used to improve IES modeling capabilities.

99 GENERAL AND MISCELLANEOUS↗

Cost-effectiveness of integrated analysis/design systems /IPAD/ An executive summary. II

Evaluation of the cost-effectiveness of integrated analysis/design systems with particular attention to Integrated Program for Aerospace-Vehicle Design (IPAD) project. An analysis of all the ingredients of IPAD indicates the feasibility of a significant cost and flowtime reduction in the product design process involved. It is also concluded that an IPAD-supported design process will provide a framework for configuration control, whereby the engineering costs for design, analysis and testing can be controlled during the air vehicle development cycle.

Miller, R. E., Jr.↗

Analysis of Radiant Cooling System Configurations Integrated with Cooling Tower for Different Indian Climatic Zones

Radiant cooling system has proven to be a low energy consumption system for building cooling needs. This study describes the use of cooling tower in radiant cooling system to improve the overall system efficiency. A comprehensive simulation feasibility study of the application of cooling tower in radiant cooling system was performed for the fifteen cities in different climatic zones of India. It was found that in summer, the wet bulb temperature (WBT) of the different climatic zones except warm-humid is suitable for the integration of cooling tower with radiant cooling system. In these climates, cooling tower can provide on average 24 C to 27 C water In order to achieve the energy saving potential, three different configurations of radiant cooling system have been compared in terms of energy consumption. The different configurations of the radiant cooling system integrated with cooling tower are: (1) provide chilled water to the floor, wall and ceiling mounted tubular installation. (2) provide chilled water to the wall and ceiling mounted tabular installation. In this arrangement a separate chiller has also been used to provide chilled water at 16 C to the floor mounted tubular installation. (3) provide chilled water to the wall mounted tabular installation and a separate chiller is used to provide chilled water at 16 C to the floor and ceiling mounted tabular installation. A dedicated outdoor air system is also coupled for dehumidification and ventilation in all three configurations. A conventional all-air system was simulated as a baseline to compare these configurations for assessing the energy saving potential.

Mathur, Jyotirmay↗