Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stroke”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

ASTP simulated lightning test report

A simulated lightning test was conducted on the backup spacecraft for the Apollo Soyuz Test Project mission (CSM-119) to determine the susceptibility of the Apollo spacecraft to damage from the indirect effects of lightning. It is demonstrated that induced lightning effects from low-level injected currents can be scaled linearly to those which are obtained in a full threat lightning stroke. Test results indicate that: (1) many of the power and signal critical circuits would fail if subjected to full-threat lightning, (2) pyrotechnic circuits are safe for full-threat lightning, and (3) common-mode voltages exceeded the failure criteria level for all but three of the circuits tested.

Blount, R. L.↗

The National Research Council program on aid to the neurologically handicapped

The multidisciplinary care of neuromuscular disabled patients is reviewed. Described are the activities of occupational and vocational therapists, social workers, clinical psychologists and speech pathologists that are directed toward the major effects of spinal cord injuries, amputations, stroke, cerebral palsy, and rheumatoid arthritis.

Mclaurin, C.↗

Current therapeutic techniques and rehabilitation from neurological disorders

Rancho Los Amigos Hospital is a 1100-bed teaching hospital that is primarily oriented toward rehabilitation. The individual services that deal with neuromuscular disorders are categorically disease entity oriented: They are directed toward the major problems, such as spinal cord injuries, amputations, stroke, cerebral palsy, and rheumatoid arthritis. The services at Rancho cross many traditional medical specialty barriers.

Nickel, V. L.↗

Search for correlation between geomagnetic disturbances and mortality

Statistical evaluation of death rates in the U.S.A. from heart diseases or stroke did not show any correlation with measured geomagnetic pulsations and thus do not support a claimed relationship between geomagnetic activity and mortality rates to low frequency fluctuations of the earth's magnetic field.

Lipa, B. J.↗

A model-based analysis of a display for helicopter landing approach

A control theoretic model of the human pilot was used to analyze a baseline electronic cockpit display in a helicopter landing approach task. The head down display was created on a stroke written cathode ray tube and the vehicle was a UH-1H helicopter. The landing approach task consisted of maintaining prescribed groundspeed and glideslope in the presence of random vertical and horizontal turbulence. The pilot model was also used to generate and evaluate display quickening laws designed to improve pilot vehicle performance. A simple fixed base simulation provided comparative tracking data.

Hess, R. A.↗

Physiological response to exercise after space flight - Apollo 14 through Apollo 17

Submaximal exercise stress tests were conducted preflight and postflight on the Apollo 14-17 crewmen. A bicycle ergometer was utilized to evoke target heart rates up to 160 beats/min while respiratory gas exchange, blood pressure, and cardiac output were measured. Three preflight tests were conducted during the month prior to flight to establish baseline values for postflight comparisons. Tachycardia was evidenced at rest and during exercise immediately postflight. This transitory tachycardia compensated for reduced stroke volume. Systolic blood pressure was reduced during exercise stress, but no consistent changes were observed in diastolic blood pressure. With the exception of the Apollo 15 crewmen, all crewmen had returned to preflight response levels by the day following recovery. No changes were observed in mechanical or respiratory efficiency immediately postflight.

Rummel, J. A.↗

Continuous cardiac output measurement - Aspects of Doppler frequency analysis

From the suprasternal notch blood flow velocity in the aorta can be measured non-invasively by a Doppler probe. Integration over systole after frequency analysis gives a measure of stroke volume if a separate diameter observation is incorporated. Frequency analysis by a zero crossing counter or by a set of parallel phaselock loops was less effective than a set of bandpass filters. Observations on dogs, baboons and humans before and after exercise or surgery suggest the indications to be useful. Application to judging heart failure by the effect of introducing a volume load is indicated. Changes in output also are measured in freely moving subjects.

Mackay, R. S.↗

Skylab experiment M-171 'Metabolic Activity' - Results of the first manned mission

The experiment was performed to ascertain whether man's ability to perform mechanical work would be altered as a result of exposure to the weightless environment. Skylab II crewmen were exercised on a bicycle ergometer at loads approximating 25%, 50%, and 75% of their maximum oxygen uptake while their physiological responses were monitored. The results of these tests indicate that the crewmen had no significant decrement in their response to exercise during their exposure to zero gravity. Immediately postflight, however, all crewmen demonstrated an inability to perform the programmed exercise with the same metabolic effectiveness as they did both preflight and inflight. The most significant changes were elevated heart rates for the same work load and oxygen consumption (decreased oxygen pulse), decreased stroke volume, and decreased cardiac output at the same oxygen consumption level. It is apparent that the changes occurred inflight, but did not manifest themselves until the crewmen attempted to readapt to the 1-G environment.

Michel, E. L.↗

Heavy-duty mechanical sequencer

Modular sequential mechanism allows output stroke angle and location of start/stop points to be pre-programmed. Output torques are higher than typical Geneva mechanisms, are constant throughout cycle, and have a moment equal to that of power source.

Appleberry, W. T.↗

Electrostatic-discharge ignition

Electrode in cylinder permits charge to transfer during top dead center compression stroke in modified Otto-cycle engine. Charge transfer produces spark which causes ignition of droplets without resorting to other ignition devices which are incapable of igniting ultralean mixtures.

Stephens, J. B.↗

Simulated lightning test shuttle .03 scale model

Lightning Attach Point tests were conducted for the space shuttle launch configuration (Orbiter, External Tank and Solid Rocket Boosters). A series of 250 long spark tests (15 to 20 foot sparks) determined that the orbiter may be struck on the nose, windshield brow, tail and wingtips during launch but not on the main engine nozzles which have been shown to be vulnerable to lightning damage. The orbiter main engine and SRB exhaust plumes were simulated electrically with physical models coated with graded resistance paints. The tests showed that the exhaust plumes from the SRB provide additional protection for the main engine nozzles. However, the tests showed that the Orbiter Thermal Protection System (TPS), which has also been shown to be vulnerable to lightning damage, may be struck during launch. Therefore further work is indicated in the areas of swept stroke studies on the model and on TPS panels. Further attach point testing is also indicated on the free-flying orbiter. Photographs of the test setup are shown.

Clifford, D. W.↗

Exercise cardiac output following Skylab missions - The second manned Skylab mission

Cardiac output was measured during preflight and postflight exercise-stress tests on the Skylab astronauts. In the postflight tests immediately following the 28-, 59-, and 84-d earth orbital missions, the astronauts exhibited an approximate 30% decrease in cardiac output coupled with an approximate 50% decrease in cardiac stroke volume during exercise. These changes were accompanied by elevated heart rates and significant increases in total systemic peripheral vascular resistance. Mean arterial pressure was unchanged. All parameters returned to normal preflight values within 30 d of the end of the orbital period. Duration of the zero-G exposure did not appear to influence either the magnitude of the hemodynamic changes or the time-course of their return to normal. These results are discussed in relation to other cardiovascular findings and possible mechanisms responsible for the observations are outlined.

Buderer, M. C.↗

Alternative general-aircraft engines

The most promising alternative engine (or engines) for application to general aircraft in the post-1985 time period was defined, and the level of technology was cited to the point where confident development of a new engine can begin early in the 1980's. Low emissions, multifuel capability, and fuel economy were emphasized. Six alternative propulsion concepts were considered to be viable candidates for future general-aircraft application: the advanced spark-ignition piston, rotary combustion, two- and four-stroke diesel, Stirling, and gas turbine engines.

Tomazic, W. A.↗

Laser-zone growth in a Ribbon-To-Ribbon (RTR) process silicon sheet growth development for the large area silicon sheet task of the low cost silicon solar array project

The Ribbon-to-Ribbon (RTR) approach to silicon ribbon growth was investigated. An existing RTR apparatus, RTR#1, was upgraded to allow for 5 cm wide ribbon growth with a finite stroke length of at least 15 cm. A second RTR apparatus, RTR#2, was designed, built, and operated which utilizes continuous feed mechanisms and allows continuous growth of 7.5 cm wide ribbons. RTR#2 includes development and utilization of advanced beam scanning (or shaping), high power lasers, and thermal profile modification elements to attain maximum growth velocities (with a design goal of 18 cm/min). Materials studies, process development, and thermal analyses are also described. Residual stresses and dislocation densities were minimized through theoretical and experimental efforts towards optimization of thermal profiles. Growth runs were performed on RTR#2 and solar cells were fabricated which demonstrated efficiencies greater than 10%.

Gurtler, R. W.↗

Effect of prolonged space flight on cardiac function and dimensions

By taking advantage of the capabilities of echocardiography to measure noninvasively left ventricular volume, stroke volume, and ejection fraction, and of the fact that the astronauts were routinely subjected to lower body negative pressure (whereby cardiac filling is progressively decreased), it was possible to construct classic ventricular function curves noninvasively, thereby obviating the difficulties encountered in comparing cardiac function at different end-diastolic volumes preflight and postflight. In this manner, the effect of an 84-day period of weightlessness on cardiac structure and function was evaluated in the Skylab 4 astronauts.

Henry, W. L.↗

Medical experiment M-171 - Results from the second manned Skylab mission

Preflight, inflight, and postflight exercise response tests were conducted on the astronauts of the second Skylab mission as part of an evaluation of physiological adaptation to long-term weightlessness. The flight phase of this mission was 59 days in duration. An exercise protocol was designed around a bicycle ergometer which was used to apply work loads approximating 25, 50, and 75% of each crewman's measured maximum aerobic capacity. Respiratory gas exchange, heart rate, and blood pressure were measured during all tests; cardiac output was measured at selected times during preflight and postflight tests. Data obtained both at rest and during exercise in flight showed no consistent changes which would indicate a degraded physical work capacity. In fact, heart rate during exercise actually decreased for all crewmen in flight. This response indicated improved physical fitness in flight relative to preflight. The postflight period of readaptation to 1 G was characterized by a marked tachycardia, during which time stroke volume was decreased. This response returned to normal within 5-day postflight.

Rummel, J. A.↗

Regional myocardial shape and dimensions of the working isolated canine left ventricle

Angiographic experiments were performed on isolated canine left ventricle preparations using donor dog to supply blood to the coronary circulation via a rotary pump to control coronary flow. The angiographic record was transferred from video tape to video disk for detailed uninterrupted sequential analysis at a frequency of 60 fields/sec. It is shown that the use of a biplane X-ray technique and a metabolically supported isolated canine left ventricle preparation provides an angiographically ideal means of measuring the mechanical dynamics of the myocardium while the intact left ventricular myocardial structure and electrical activation pattern retain most of the in situ ventricular characteristics. In particular, biplane X-ray angiography of the left ventricle can provide estimates of total ventricular function such as ejection fraction, stroke volume, and myocardial mass correct to within 15% under the angiographically ideal conditions of the preparation.

Ritman, E.↗