Note: Plasma optical emission spectroscopy for water vapor quantification and detection during vacuum drying process

In this work, a methodology involving plasma optical emission spectroscopy driven by a direct current (dc) plasma source is developed to quantify water vapor concentration in a gaseous stream. The experimental setup consists of a dc driven low-pressure plasma cell in which the emission from the plasma discharge is measured by using an optical emission spectrometer. The emission from Hα at 656.2 nm—the first transition in the Balmer series, was found to be the most sensitive to the water vapor concentration in the gas stream. Consistent linear trends of the emission signals with respect to variation in concentration of water are observed for multiple combinations of operating parameters. This method has been applied to a vacuum drying process of a mock nuclear fuel assembly to quantify the concentration of water vapor during the drying process.

47 OTHER INSTRUMENTATION↗

Data and scripts associated with “Point-scale organic-matter decomposition in streambeds is weakly associated with reach-scale respiration”

This data package is associated with “Point-scale organic-matter decomposition in streambeds is weakly associated with reach-scale respiration” published in EGU Biogeosciences (Stegen et al., 2026; https://doi.org/10.5194/bg-23-3981-2026). It contains cotton strip decomposition rates (Kcd and Kdd) collected across the Yakima River Basin (YRB), Washington, USA. These data were collected to support a broader study examining the drivers of spatial variability in sediment respiration rates in the Yakima River Basin. Associated data used in analysis, metadata, and field protocols can be accessed at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1923689, https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1969566, and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1987520. This data package is associated with the repository found at https://github.com/river-corridors-sfa/rcsfa-ST-2B-SSS-cotton-strip. A preliminary version of this data package was published in December 2025 at the time of manuscript submission. It was updated in June 2026, at the time of manuscript acceptance, to include additional metadata (this readme, data dictionary, and file level metadata). The data did not change. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This data package consists of (1) readme; (2) data dictionary (dd); (3) file level metadata (flmd); and (4) four folders: (1) R-scripts; (2) figures; (3) outputs from the scripts; and (4) published data. The published data folder contains a readme directing the user to download data in order to run the R-scripts. All files are .csv, .pdf, .R, .Rmd, and .txt. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Waste Heat Recovery and Utilization from Residential Appliances and Fixtures

Executive Summary In every home irrespective of its size, location, age, or efficiency, heat in the form of drainwater or dryer exhaust is wasted. Although from a waste stream, this energy has the potential for being captured, possibly stored, and then reused for preheating hot water or air thereby saving operating costs to the homeowner. In applications such as a shower and possibly a dryer, waste heat is produced at the same time as energy is used, so that a heat exchanger to capture the waste energy and return it to the supply is all that is needed. In other applications such as capturing the energy in drainwater from a tub, dishwasher, or washing machine, the availability of waste heat might not coincide with an immediate use for energy, and consequently a heat exchanger system with heat storage capacity (i.e. a regenerator) would be necessary. This study describes a two-house experimental evaluation of a system designed to capture waste heat from the shower, dishwasher clothes washer and dryer, and to use this waste heat to offset some of the hot water energy needs of the house. Although each house was unoccupied, they were fitted with equipment that would completely simulate the heat loads and behavior of human occupants including operating the appliances and fixtures on a demand schedule identical to Building American protocol (Hendron, 2009). The heat recovery system combined (1) a gravity-film heat exchanger (GFX) installed in a vertical section of drainline, (2) a heat exchanger for capturing dryer exhaust heat, (3) a preheat tank for storing the captured heat, and (4) a small recirculation pump and controls, so that the system could be operated anytime that waste heat from the shower, dishwasher, clothes washer and dryer, and in any combination was produced. The study found capturing energy from the dishwasher and clothes washer to be a challenge since those two appliances dump waste water over a short time interval. Controls based on the status of the dump valve on these two appliances would have eliminated uncertainty in knowing when waste water was flowing and the recovery system operated. The study also suggested that capture of dryer exhaust heat to heat incoming air to the dryer should be examined as an alternative to using drying exhaust energy for water heating. The study found that over a 6-week test period, the system in each house was able to recover on average approximately 3000 W-h of waste heat daily from these appliance and showers with slightly less on simulated weekdays and slightly more on simulated weekends which were heavy wash/dry days. Most of these energy savings were due to the shower/GFX operation, and the least savings were for the dishwasher/GFX operation. Overall, the value of the 3000 W-h of displaced energy would have been $0.27/day based on an electricity price of $.09/kWh. Although small for today s convention house, these savings are significant for a home designed to approach maximum affordable efficiency where daily operating costs for the whole house are less than a dollar per day. In 2010 the actual measured cost of energy in one of the simulated occupancy houses which waste heat recovery testing was undertaken was $0.77/day.

Tomlinson, John J.↗

Powertrain Controls Optimization for HD Hybrid Line Haul Trucks - FY2014 Annual Report

This is a vehicle system level project, encompassing analytical modeling and supervisory controls development as well as experimental verification/validation testing at the component, powertrain, and full vehicle system level. This project supports the goal of petroleum consumption reduction for medium and heavy trucks through the development of advanced hybrid technologies and control systems. VSST has invested previously in R&D to support hybrid energy storage systems (Li-ion plus ultra-caps) for light duty, passenger car applications. This research will be extended to the MD and HD sector where current battery technology is not mature enough to handle the substantial regenerative braking power levels these trucks are capable of producing. With this hybrid energy storage system, substantial gains in overall vehicle efficiency are possible. In addition, advanced combustion technologies, such as RCCI, will be implemented into an advanced hybrid powertrain for a Class 8 line haul application. This powertrain, leveraged from other VSST work (Meritor, a current ORNL/VSST partner), is ideal for taking advantage of the benefits of RCCI operation due to its series hybrid mode of operation. Emissions control is also a focus of this project, especially due to the fact that RCCI creates a low temperature exhaust stream that must addressed.

33 ADVANCED PROPULSION SYSTEMS↗

Slipstream pilot-scale demonstration of a novel amine-based post-combustion technology for carbon dioxide capture from coal-fired power plant flue gas

Post-combustion CO 2 capture (PCC) technology offers flexibility to treat the flue gas from both existing and new coal-fired power plants and can be applied to treat all or a portion of the flue gas. Solvent-based technologies are today the leading option for PCC from commercial coal-fired power plants as they have been applied in large-scale in other applications. Linde and BASF have been working together to develop and further improve a PCC process incorporating BASF’s novel aqueous amine-based solvent technology. This technology offers significant benefits compared to other solvent-based processes as it aims to reduce the regeneration energy requirements using novel solvents that are very stable under the coal-fired power plant feed gas conditions. BASF has developed the desired solvent based on the evaluation of a large number of candidates. In addition, long-term small pilot-scale testing of the BASF solvent has been performed on a lignite-fired flue gas. In coordination with BASF, Linde has evaluated a number of options for capital cost reduction in large engineered systems for solvent-based PCC technology. This report provides a summary of the work performed and results from a project supported by the US DOE (DE-FE0007453) for the pilot-scale demonstration of a Linde-BASF PCC technology using coal-fired power plant flue gas at a 1-1.5 MWe scale in Wilsonville, AL at the National Carbon Capture Center (NCCC). Following a project kick-off meeting in November 2011 and the conclusion of pilot plant design and engineering in February 2013, mechanical completion of the pilot plant was achieved in July 2014, and final commissioning activities were completed to enable start-up of operations in January 2015. Parametric tests were performed from January to December 2015 to determine optimal test conditions and evaluate process performance over a variety of operation parameters. A long-duration 1500-hour continuous test campaign was performed from May to August 2016 at a selected process condition to evaluate process performance and solvent stability over a longer period similar to how the process would operate as a continuously running large-scale PCC plant. The pilot plant integrated a number of unique features of the Linde-BASF technology aimed at lowering overall energy consumption and capital costs. During the overall test period including startup, parametric testing and long-duration testing, the pilot plant was operated for a total of 6,764 hours out of which testing with flue gas was performed for 4,109 hours. The pilot plant testing demonstrated all of the performance targets including CO 2 capture rate exceeding 90%, CO 2 purity exceeding 99.9 mol% (dry), flue gas processing capacity up to 15,500 lbs/hr (equivalent to 1.5 MWe capacity slipstream), regeneration energy as low as 2.7 GJ/tonne CO 2 , and regenerator operating pressure up to 3.4 bara. Excellent solvent stability performance data was measured and verified by Linde and BASF during both test campaigns. In addition to process data, significant operational learnings were gained from pilot tests that will contribute greatly to the commercial success of PCC. Based on a thorough techno-economic assessment (TEA) of the Linde-BASF PCC process integrated with a 550 MWe supercritical coal-fired power plant, the net efficiency of the integrated power plant with CO 2 capture is increased from 28.4% with the DOE/NETL Case 12 reference to 30.9% with the Linde-BASF PCC plant previously presented utilizing the BASF OASE® blue solvent [Ref. 4], and is further increased to 31.4% using a Linde-BASF PCC plant with BASF OASE® blue solvent and an advanced stripper interstage heater (SIH) configuration. The Linde-BASF PCC plant incorporating the BASF OASE® blue solvent also results in significantly lower overall capital costs, thereby reducing the cost of electricity (COE) and cost of CO 2 captured from $147.25/MWh and $56.49/MT CO 2 , respectively, for the reference DOE/NETL Case 12 plant, to $128.49/MWh and $41.85/MT CO2 for process case LB1, respectively, and $126.65/MWh and $40.66/MT CO 2 for process case SIH, respectively. With additional innovative Linde-BASF PCC process configuration improvements, the COE and cost of CO 2 captured can be further reduced to $125.51/MWh and $39.90/MT CO 2 for a further optimized PCC process defined as LB1-CREB. Most notably, the Linde-BASF process options assessed have already demonstrated the potential to lower the cost of CO 2 captured below the DOE target of $40/MT CO 2 at the 550 MWe scale for second generation PCC technologies. Project organization, structure, goals, tasks, accomplishments, process criteria and milestones will be presented in this report along with highlights and key results from parametric and long-duration testing of the Linde-BASF PCC pilot. The parametric and long-duration testing campaigns were aimed at validating the performance of the PCC technology against targets determined from a preliminary techno-economic assessment. The stability of the solvent with extended operation in a realistic power plant setting was measured with performance verified. Additionally, general solvent classification information, process operating conditions, normalized solvent performance data, solvent stability test results, flue gas conditions data, CO 2 purity data in the gaseous product stream, steam requirements and process flow diagrams, and updated process economic data for a scaled-up 550 MWe supercritical power plant with CO 2 capture are presented and discussed in this report.

20 FOSSIL-FUELED POWER PLANTS↗

Gasification Combined Heat and Power from Coal Fines

The goal of this final project report is to comprehensively summarize the work for public domain conducted on project DE-FE 0031520. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UKy-CAER) (Recipient) has completed a Front End Engineering Design (FEED) study 5 MWe polygeneration unit using the Coal Fields Regional Industrial Park in Hazard, Kentucky (KY) as a model location and using coal recovered from the adjacent Pads Branch Impoundment as feed. The scope of work is a thorough study that can be used as a template for the application of the proposed technology throughout Eastern KY and other coal communities nationwide. The Technology Design Basis was developed based on three elements: basic site characteristics; fuel feedstock; and environmental health and safety requirements. The Basic Engineering Design Elements include the preliminary process design (the process area descriptions; the Block Flow Diagram (BFD), Process Flow Diagrams (PFDs) and Piping and Instrumentation Diagrams (P&IDs), process simulation outputs and Heat and Mass Balance (H&MB) stream tables, the major process equipment and instrumentation lists which includes specifications and materials of construction); the cost estimate (capital cost estimate, operational cost estimate, and comparison with state-of-the-art commercial scale similar technologies, options to lower cost, construction cost and schedule estimate); and other supporting elements (guidelines for execution and management of the project), logistical summary, and balance of plant summary, the Environmental Health and Safety (EH&S) assessment; and a Social and Economic Impact (S&EI) assessment. All project milestones, deliverables and success criteria were met. The proposed 5 MWe polygeneration facility being fed from impoundment recovered coal has been shown to be technically feasible. Annual revenues are estimated at $\$ $2.4M from electricity, steam and hydrocarbon production; annual operating expenses are $\$ $5.2M ($\$ $2.9 M in operating expenses, and $\$ $2.4M in indirect expenses). The gasifier facility, as configured during the FEED, will lose money when operating under commercial operating conditions and terms. However, eight options improving the economics can be considered during the detailed design phase to make the facility profitable by taking advantage of the positive differential of revenue to variable operating costs, and reducing the influence of fixed operating costs. Coupled with the findings from the S&EI assessment estimating a total economic impact of $\$ $374M for the proposed polygeneration facility at >$\$ $1.5B, if three additional such projects are implemented, clearly positive economics are demonstrated. No EH&S issues are identified that would prohibit proceeding with the project, although permitting efforts are estimated to take 3-5 years.

01 COAL, LIGNITE, AND PEAT↗

Front-End Engineering and Design: Project Tundra Carbon Capture System (Final Report)

As the next phase of Project Tundra, Minnkota Power Cooperative (MPC) completed a front-end engineering and design (FEED) study to install a post-combustion CO 2 capture system (CCS) at the MPC operated (Square Butte Electric Cooperative-owned) Milton R. Young Station (MRYS) Unit 2 (MRY2), a 477-MW power plant fueled by North Dakota lignite. The project team completed the FEED with Fluor’s Econamine FG Plus℠ (EFG+) technology and is taking the next steps leading up to start of construction. Team members included FEED technical lead Fluor Enterprises (Fluor); owner’s engineer and balance of plant (BOP) engineer Burns & McDonnell (BMcD); leading carbon capture consultants (David Greeson Consulting, Hunt International Energy Services); environmental consultants (AECOM, Agora Environmental), other BOP engineering consultants (Golder Associates, Nels); cost-share funding agency, the North Dakota Industrial Commission (NDIC); and the Energy & Environmental Research Center (EERC). Project Tundra’s goal is to implement carbon capture, utilization, and storage (CCUS) in North Dakota, while preserving the use of lignite. Future options could lead to revitalizing legacy oil fields and creating a new CO 2 enhanced oil recovery (EOR) industry. The topic of this report is the FEED study for the carbon dioxide capture portion of Project Tundra. Building on the findings of a pre-FEED study for MRY2, the key deliverables contained in this FEED study are: a) design, costing, and performance data needed to commence project financing activities; b) engineering and material balances required to file for all project permits; and c) a final project schedule. Based on the results of the previous pre-FEED study, MPC and its team evaluated two options to provide the large amount of steam needed to operate the CCS: 1) installation of new natural gas package boilers and a new pipeline to supply natural gas to the facility and 2) extraction of steam from the existing MRYS steam turbine generator. The FEED study was performed using the package boilers option, as it was deemed to have the lowest technical risk, overall cost, and cost uncertainty. A key feature of the design, however, was the mixing the natural gas boilers’ flue gas with the MRY2 flue gas. This increased the size of the CCS system. This design also enabled the tie-in of Unit 1 flue gas for times when Unit 2 is offline. The CCS was designed to capture a combined 12,978 short tons per day (STPD) of CO 2 from the flue gases produced by the existing MRY Unit 2 along with flue gas produced by the new boiler package within the CCS. The 12,978 STPD CO 2 capture is achieved by normally processing 100% of the total available MRY Unit 2 flue gas (considering full load operation) and 100% of the boiler package flue gas, then removing 90% of the CO 2 available from the processed flue gas streams.

01 COAL, LIGNITE, AND PEAT↗

Management of Alkali and Alkaline Earth Fission Products in Used Pyroprocessing Salt

Pyroprocessing of spent nuclear fuel (SNF) involves dissolving metallic fuel into a molten salt electrolyte (typically eutectic LiCl-KCl) and then preferentially depositing actinides onto inert cathodes. Subsequent operations include drawdown of residual actinides and lanthanides from the electrolyte prior to re-using the salt. The recovered actinides are recycled and the recovered lanthanides are disposed as waste. Alkali and alkaline earth metal fission products in the fuel, such as Cs, Sr and Ba, dissolve into the salt during electrorefining. The concentrations of these elements buildup over time in the molten salt electrolyte, which may change the freezing point. The radioactive decay of 137 Cs and 90 Sr (half life 30 and 29 years) generates significant heat and produces strong ionizing radiation fields (β and γ). The increasing heat load and radioactivity as these elements build up in the molten salt requires frequent replacement and disposal of the electrolyte salt. Alternatively, the salt can be treated to remove these and other elements and then recycled to the electrorefiner. An effective strategy to manage these alkali and alkaline earth metal fission products in the molten salt electrolyte would increase the efficiency of pyroprocessing and decrease the volume of salt waste requiring disposal. Alkali and alkaline earth metal fission products are extremely stable in molten salt as chlorides--even more stable than the LiCl-KCl eutectic base salt--making them challenging to remove. They are not removed during drawdown operations to recover residual actinides and lanthanides and a separate operation is required to sufficiently purify the salt for reuse. This work is focused on selecting a method for separating Cs, Sr and Ba from the salt recovered from the lanthanide drawdown operation prior to recycling the cleaned salt back to the electrorefiner. Not addressed in this work is the management of the waste stream produced by the separation. This report summarizes the issues to be addressed when developing removal strategies for cesium, strontium, and barium and reviews existing methods to identify suitable methods and any technological gaps in their application.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Full Scale HEPA Filter Encapsulation in Ultra-High-Performance Grout - Proof of Concept

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) currently being constructed to treat radioactive waste, includes vitrification facilities for both the high-level waste (HLW) and low activity waste (LAW) fractions. Operation of the WTP will produce contaminated high-efficiency particulate air filters (HEPA), as part of the solid secondary waste (SSW) stream. The HEPA filters receive off-gas from the vessel vent header and primary off-gas treatment system in LAW Facility and remove particulate contaminants including 99 Tc and 129 I salts. The current disposal method for HEPA filters is encapsulation in metal containers using cementitious material (CM) and disposal in the Integrated Disposal Facility (IDF). Results from the 2017 IDF Performance Assessment (PA) WRPS (2018) demonstrated that while compliance is maintained for the 1000 year compliance period mandated by DOE O 435.1 and its accompanying manual, release of constituents from the HEPA filters result in exceedance of the performance objective imposed as the groundwater regulatory limit at later times. For example, at about 1500 years post-closure, solid secondary waste (SSW), including HEPA filters is predicted to become a dominant contributor to 99 Tc release and over the 10,000-year sensitivity analysis period, SSW is the dominant contributor of 129 I release to the groundwater. The estimated release could potentially be reduced if the HEPA filters are not compacted and waste containers could be distributed throughout a large space, thereby diluting the contaminant release. Additionally, a better cementitious material could be used to encapsulate the HEPA filters. One alternative method for disposal of contaminated HEPA filters is encapsulation of the filters in ultra high-performance grout (UHPG). UHPG is a variation of ultra-high-performance concrete (UHPC) is commonly used in the prestressed concrete industry for large structural members. Recent studies of UHPG show it has excellent properties for containing radionuclides such as 99 Tc and 129 I Nichols and Kaplan (2021). This report presents the results of the first attempt to encapsulate a clean, full-size HEPA filter in UHPG and evaluate the effectiveness of the immobilization process and final waste form. A full-scale proof-of-concept simulated waste form was prepared by encapsulating a HEPA filter in a 110-gallon stainless steel (SS) drum using UHPG. A change from Type I/II PC to Type 1L PLC was made after American Rock Products informed the team that they would no longer be using Type I/II by the end of 2024 and the northwest was phasing out Type I/II PC overall. Type I/II PC used in previous studies of UHPG for encapsulation (Nichols and Kaplan 2021). After the UHPG was cured both the scaled mockup and the full-scale simulated waste forms were sectioned for visual examination. UHPG completely encapsulated the filters and bonded to the external surfaces of materials comprising the filters. No cracks were observed in the sectioned waste forms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EFFLUENT TREATMENT FACILITY PEROXIDE DESTRUCTION CATALYST TESTING

The 200 Area Effluent Treatment Facility (ETF) main treatment train includes the peroxide destruction module (PDM) where the hydrogen peroxide residual from the upstream ultraviolet light/hydrogen peroxide oxidation unit is destroyed. Removal of the residual peroxide is necessary to protect downstream membranes from the strong oxidizer. The main component of the PDM is two reaction vessels utilizing granular activated carbon (GAC) as the reaction media. The PDM experienced a number of operability problems, including frequent plugging, and has not been utilized since the ETF changed to groundwater as the predominant feed. The unit seemed to be underperforming in regards to peroxide removal during the early periods of operation as well. It is anticipated that a functional PDM will be required for wastewater from the vitrification plant and other future streams. An alternate media or methodology needs to be identified to replace the GAC in the PDMs. This series of bench scale tests is to develop information to support an engineering study on the options for replacement of the existing GAC method for peroxide destruction at the ETF. A number of different catalysts will be compared as well as other potential methods such as strong reducing agents. The testing should lead to general conclusions on the viability of different catalysts and identify candidates for further study and evaluation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uranyl Nitrate Flow Loop

The objectives of the work discussed in this report were to: (1) develop a flow loop that would simulate the purified uranium-bearing aqueous stream exiting the solvent extraction process in a natural uranium conversion plant (NUCP); (2) develop a test plan that would simulate normal operation and disturbances that could be anticipated in an NUCP; (3) use the flow loop to test commercially available flowmeters for use as safeguards monitors; and (4) recommend a flowmeter for production-scale testing at an NUCP. There has been interest in safeguarding conversion plants because the intermediate products [uranium dioxide (UO{sub 2}), uranium tetrafluoride (UF{sub 4}), and uranium hexafluoride (UF{sub 6})] are all suitable uranium feedstocks for producing special nuclear materials. Furthermore, if safeguards are not applied virtually any nuclear weapons program can obtain these feedstocks without detection by the International Atomic Energy Agency (IAEA). Historically, IAEA had not implemented safeguards until the purified UF{sub 6} product was declared as feedstock for enrichment plants. H. A. Elayat et al. provide a basic definition of a safeguards system: 'The function of a safeguards system on a chemical conversion plant is in general terms to verify that no useful nuclear material is being diverted to use in a nuclear weapons program'. The IAEA now considers all highly purified uranium compounds as candidates for safeguarding. DOE is currently interested in 'developing instruments, tools, strategies, and methods that could be of use to the IAEA in the application of safeguards' for materials found in the front end of the nuclear fuel cycle-prior to the production of the uranium hexafluoride or oxides that have been the traditional starting point for IAEA safeguards. Several national laboratories, including Oak Ridge, Los Alamos, Lawrence Livermore, and Brookhaven, have been involved in developing tools or techniques for safeguarding conversion plants. This study was sponsored by the U.S. Department of Energy (DOE) NA-241, Office of Dismantlement and Transparency.

Ladd-Lively, Jennifer L↗

Enhancing Building Energy Efficiency through Advanced Sizing and Dispatch Methods for Energy Storage

Energy storage and electrification of buildings hold great potential for future decarbonization. However, there are several technical and economic barriers that prevent large-scale adoption and integration of energy storage in buildings. These barriers include integration with building control systems, high capital costs, and the necessity to identify and quantify value streams for different stakeholders. To overcome these obstacles, it is crucial to develop advanced sizing and dispatch methods to assist planning and operational decision-making for integrating energy storage in buildings. This work develops simple and flexible optimal sizing and dispatch framework for thermal energy storage (TES) and battery energy storage (BES) systems in large-scale office building. The optimal sizes of TES, BES, as well as other building assets are determined in a joint manner instead of sequentially to avoid sub-optimal solutions. The interaction between the sizing at the planning stage and hourly or sub-hourly dispatch at the operating stage is explicitly modeled. The solution is determined considering both capital costs in optimal sizing and operational benefits in optimal dispatch. Comprehensive assessments are performed using simulation studies to quantify potential energy, economic, and emission benefits by different utility tariffs and climate locations, to improve our understanding of the techno-economic performance of different TES and BES systems, and to identify barriers for adopting energy storage for buildings. Finally, the proposed framework will provide guidance to a broad range of stakeholders to properly design energy storage in buildings and maximizes potential benefits, thereby advancing affordable building energy storage deployment and helping us accelerating the transition towards a cleaner and more equitable energy economy.

Yu, Mingyung↗

On-Line Monitoring and Real-Time Characterization of Low Level Waste and Off-Gas Condensate Samples using Raman Spectroscopy

The demand for Hanford waste property analysis is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward transferring waste to the Hanford Waste Treatment and Immobilization Plant. The analysis of waste includes chemical, radionuclide, and physical property characterizations, with the goal of achieving safe/informed transfer and processing. Waste sampling followed by offline laboratory analysis is the current baseline analytical approach. The addition of field-deployed/in situ instruments has the potential to provide improvements and benefits over offline analysis in the areas of 1) Worker Safety: by reducing the need for sampling and thereby reducing the need for worker interaction with waste during sample handling; 2) Operational Efficiency: by reducing analysis turnaround times and offsetting demand on analytical laboratories; and 3) Accuracy: continuous analysis of a flowing waste stream allows cumulative results to be produced for the batch, which is likely to be more representative than discrete samples of batch properties. This paper describes the development and application of an online monitor to provide chemical characterizations; specifically, Raman spectroscopy is utilized to identify and quantify tank components. Accurate quantification is achieved through the use of chemometric analysis, which can be configured to provide real-time analysis in field deployment settings.

Lines, Amanda M.↗

On-Line Monitoring and Real-Time Characterization of Low Level Waste and Off-Gas Condensate Samples using Raman Spectroscopy - 19274

The demand for Hanford waste property analysis is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward transferring waste to the Hanford Waste Treatment and Immobilization Plant. The analysis of waste includes chemical, radionuclide, and physical property characterizations, with the goal of achieving safe/informed transfer and processing. Waste sampling followed by offline laboratory analysis is the current baseline analytical approach. The addition of field-deployed/in situ instruments has the potential to provide improvements and benefits over offline analysis in the areas of 1) Worker Safety: by reducing the need for sampling and thereby reducing the need for worker interaction with waste during sample handling; 2) Operational Efficiency: by reducing analysis turnaround times and offsetting demand on analytical laboratories; and 3) Accuracy: continuous analysis of a flowing waste stream allows cumulative results to be produced for the batch, which is more representative than discrete samples of batch properties. This paper describes the development and application of an online monitor to provide chemical characterizations; specifically, Raman spectroscopy is utilized to identify and quantify tank components. Accurate quantification is achieved through the use of chemometric analysis, which can be configured to provide real-time analysis in field deployment settings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Abstract: Air, Thermal and Water Management for PEM Fuel Cell Systems

PEM fuel cells are excellent candidates for transportation applications due to their high efficiencies. PEM fuel cell Balance of Plant (BOP) components, such as air, thermal, and water management sub-systems, can have a significant effect on the overall system performance, but have traditionally not been addressed in research and development efforts. Recognizing this, the U.S. Department of Energy and Honeywell International Inc. are funding an effort that emphasizes the integration and optimization of air, thermal and water management sub-systems. This effort is one of the major elements to assist the fuel cell system developers and original equipment manufacturers to achieve the goal of an affordable and efficient power system for transportation applications. Past work consisted of: (1) Analysis, design, and fabrication of a motor driven turbocompressor. (2) A systematic trade study to select the most promising water and thermal management systems from five different concepts (absorbent wheel humidifier, gas to gas membrane humidifier, porous metal foam humidifier, cathode recycle compressor, and water injection pump.) This presentation will discuss progress made in the research and development of air, water and thermal management sub-systems for PEM fuel cell systems in transportation applications. More specifically, the presentation will discuss: (1) Progress of the motor driven turbocompressor design and testing; (2) Progress of the humidification component selection and testing; and (3) Progress of the thermal management component preliminary design. The programs consist of: (1) The analysis, design, fabrication and testing of a compact motor driven turbocompressor operating on foil air bearings to provide contamination free compressed air to the fuel cell stack while recovering energy from the exhaust streams to improve system efficiency. (2) The analysis, design, fabrication and testing of selected water and thermal management systems and components to improve system efficiency and reduce packaging size.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing Hanford's Direct Feed Low Activity Waste Program - 20002

The Office of River Protection (ORP) is responsible for the management and completion of the River Protection Project (RPP) mission, which comprises both the Hanford Site tank farms operations and the completion and operation of the Waste Treatment and Immobilization Plant Project. The RPP mission is to safely retrieve, treat, and immobilize Hanford's high-level and low-activity tank waste and close the tank farms to protect the Columbia River. The Direct-Feed Low-Activity Waste (DFLAW) Program is a major subset of the overall RPP mission, providing disposition of low-activity waste. The scope is to retrieve, treat, and immobilize the low-activity waste at the Low-Activity Waste Facility. DFLAW will begin operations no later than December 2023. The DFLAW Program overarches a suite of individual projects, activities, and infrastructure upgrades. The major projects and activities include multiple contractors under both ORP and the Richland Operations Office, underscoring the need for effective integration, coordination, and collaboration. The objectives of the DFLAW Program leadership team are to: - Effectively coordinate and integrate the projects that comprise the DFLAW Program - Manage the interfaces between the projects so that the integrated DFLAW Program is completed successfully - Ensure the DFLAW portfolio of projects operate as required without gaps or conflicts at the interfaces. DOE is accomplishing these objectives through a newly established leadership model that integrates the DOE and contractor work streams and promotes a teamwork model to enable collaborative success. Long considered one of the most formidable cleanup challenges at Hanford, the Department of Energy and its contractors are on the verge of achieving a cleanup commitment that has been decades in the making. DOE is preparing to vitrify (turn to glass) Hanford's chemical and radioactive tank waste using the DFLAW process. The Modified Consent Decree milestone for completing hot commissioning of the Hanford Site's Low- Activity Waste Facility is Dec. 31, 2023. While this milestone may seem distant under normal project management circumstances, it is a relatively short period of time for the operational and cultural transformation necessary to successfully begin treating tank waste at Hanford. Direct feed means separating the waste at a tank farm to remove the more radioactive portion (i.e., solids and cesium) so that the resulting low-activity (less radioactive) waste can be fed directly to the Waste Treatment and Immobilization Plant's Low-Activity Waste Facility. Starting DFLAW will require a singular, intensive leadership focus, along with a sustained, collective commitment to excellence and teamwork by the Department and its contractors. Major upgrades to Hanford's infrastructure will occur prior to startup. Supporting DFLAW operations requires significant integration between the DFLAW facilities - the Waste Treatment Plant, Hanford's tank farms, effluent treatment facilities, disposal facilities - and between all of the site contractors to achieve success. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced carbon-transfer and -utilization efficiencies achieved using membrane carbonation with gas sources having a range of CO 2 concentrations

The economic viability of microalgal biofuels relies on increasing productivity in a cost-effective manner. As microalgal biomass contains > 50% carbon, a high rate of CO 2 delivery is required for high productivity, and inefficient CO 2 delivery amplifies operating costs. Membrane carbonation using non-porous hollow fiber membranes can ideally deliver CO 2 without bubble formation and high carbon transfer efficiency. Because CO 2 streams from industrial resources are not 100% CO 2 , the buildup of inert gasses can significantly lower the CO 2 delivery rate when the distal end of the membrane is closed. To overcome the buildup of inert gases, we managed the distal end of the membranes with three different approaches: fully open end, restricted bleed valve, and restricted bleed valve with pH-actuated venting. For all approaches, CO 2 was delivered to membranes ondemand based on a pH set point. Evaluating a wide range of CO 2 concentrations (10% to 100%), we found that all approaches eliminated the buildup of inert gases, could maintain target pH values and gave the same biomass productivities and carbon distributions. However, carbon transfer efficiency depended on the operation of the distal end. Fully open-end operation gave a poor carbon transfer efficiency because of excessive loss of CO 2 from the distal end. However, restricting the exit flow rate to ≤4 cm 3 /min mitigated the problems of excessive CO 2 loss, but without incurring a large loss of CO 2 -delivery flux. For the continuous cultivation, combining a restricted bleed valve with pH-actuated venting improved the carbon-transfer efficiency and -utilization efficiencies up to 85% and 67%, respectively, with a sufficient CO 2 delivery flux.

42 ENGINEERING↗

Adsorption Model for Off-Gas Separation

The absence of industrial scale nuclear fuel reprocessing in the U.S. has precluded the necessary driver for developing the advanced simulation capability now prevalent in so many other countries. Thus, it is essential to model complex series of unit operations to simulate, understand, and predict inherent transient behavior and feedback loops. A capability of accurately simulating the dynamic behavior of advanced fuel cycle separation processes will provide substantial cost savings and many technical benefits. The specific fuel cycle separation process discussed in this report is the off-gas treatment system. The off-gas separation consists of a series of scrubbers and adsorption beds to capture constituents of interest. Dynamic models are being developed to simulate each unit operation involved so each unit operation can be used as a stand-alone model and in series with multiple others. Currently, an adsorption model has been developed in gPROMS software. Inputs include gas stream constituents, sorbent, and column properties, equilibrium and kinetic data, and inlet conditions. It models dispersed plug flow in a packed bed under non-isothermal and non-isobaric conditions for a multiple component gas stream. The simulation outputs component concentrations along the column length as a function of time from which the breakthrough data is obtained. It also outputs temperature along the column length as a function of time and pressure drop along the column length. Experimental data will be input into the adsorption model to develop a model specific for iodine adsorption on silver mordenite as well as model(s) specific for krypton and xenon adsorption. The model will be validated with experimental breakthrough curves. Another future off-gas modeling goal is to develop a model for the unit operation absorption. The off-gas models will be made available via the server or web for evaluation by customers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗