Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “statistical analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Mortality and Rates of Secondary Intervention After EVAR in an Unselected Population: Influence of Simple Clinical Categories and Implications for Surveillance

IntroductionPost-EVAR surveillance has a major impact upon patients, carers and healthcare resources. We hypothesised that elective indication, on-IFU anatomy, use of a modern device or normal first CTA, or a combination of these categories, might predict a rate of secondary intervention low enough to alter current surveillance protocols.MethodsPatients undergoing EVAR in our institution between 01.05.2007 and 28.02.2013 were assessed. Data on indication (elective, emergency), anatomy relative to IFU, device, first month CTA result, secondary intervention and mortality were obtained. Kaplan–Meier charts of mortality and freedom from secondary intervention were produced. Statistical analysis was by log-rank test and Cox proportional hazard modelling.Results234 patients underwent EVAR (188 elective, 208 on-IFU). Most implants were Endurant (106) or Talent (98). 151 patients had a normal first CTA. By median follow-up of 38.6 months, 39 patients underwent secondary intervention. A normal first CTA and elective indication were significantly associated with reduced risk of secondary intervention (p < 0.001 and p = 0.042 respectively), but device type and placement on- or off-IFU were not. Elective placement with a normal first CTA was 93 % predictive of freedom from secondary intervention by 32 months post-EVAR. Of nine patients undergoing secondary intervention in this group, eight presented symptomatically.DiscussionIn optimal procedural circumstances with normal post-procedural imaging, only 7 % of patients undergoing EVAR require secondary intervention, a minority of which is driven by surveillance. These data support a change to surveillance more tailored to the individual patient, and highlight the need for further qualitative and quantitative research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia

PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visibility of Hypovascularized Liver Tumors during Intra-Arterial Therapy Using Split-Bolus Single-Phase Cone Beam CT

Purpose: To validate a split-bolus contrast injection protocol for single-phase CBCT in terms of detectability of hypovascular liver tumors compared to digital subtraction angiography (DSA). Materials and Methods: In this retrospective, single-center study, 20 consecutive patients with in total 77 hypovascularized tumors referred for intra-arterial therapy received a split-bolus single-phase CBCT. Two readers rated the visibility of the target tumors scheduled for embolization in CBCT and DSA compared to the pre-interventional multiphasic CT or MRI used as reference on a 3-point scoring system (1 = optimal, 3 = not visible) and catheter-associated artifacts (1 = none, 3 = extended). SNR, CNR and contrast values were derived from 37 target tumors in CBCT and MRI. Statistical analysis included the kappa test to determine interrater reliability, the Friedman’s test for the inter-modality comparison evaluating tumor visibility in DSA and CBCT as well as for quantitative assessment. Post hoc analysis included the Wilcoxon signed-rank test. p values < 0.05 were considered significant. Results: Ninety percentage of target tumors were rated as visible in CBCT and 37.5% in DSA (p < 0.001). 70.1% of pre-interventionally detected hypovascularized tumors were depicted with CBCT and 31.2% by DSA (p < 0.001). 7.8% of known tumors were outside the FOV. Quantitative assessment showed higher image contrasts in CBCT (1.91 ± 7.01) compared to hepatobiliary-phase MRI (0.29 ± 0.14, p = 0.003) and to portal-venous (p.v.) MRI (0.31 ± 0.13, p < 0.001), but higher CNR for MRI (1.18 ± 0.80; 13.92 ± 15.82; 13.79 ± 6.65). Conclusion: In conclusion, the split-bolus single-phase CBCT detects significantly more hypovascularized liver tumors compared to DSA performed through the proper hepatic artery with high image contrasts. Level of Evidence: Level III, diagnostic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Direct Computed Tomography Venography in Predicting Inflow for Venous Reconstruction in Chronic Post-thrombotic Syndrome

Purpose: The purpose of this paper is to assess the applicability of direct computed tomography venography (DCTV) in assessing dominant inflow vein in the femoral confluence in extensive chronic iliofemoral venous obstruction, using venography as the gold standard. Methods: All DCTVs performed in symptomatic patients with previous iliofemoral deep vein thrombosis subsequently submitted to venography in the period from January 2014 to August 2018 were retrospectively reviewed. Two groups were defined depending on whether the femoral vein (FV) or the deep femoral vein (DFV) was the dominant inflow on venography in order to identify predictors of DFV as dominant inflow in DCTV. Statistical analysis was performed with SPSS V25. Results: A total of 30 DCTVs and subsequent venographies were reviewed. Venography identified the FV as the dominant inflow in 18 (60%) and the DFV in 12 (40%) patients. Predictors for DFV as dominant inflow were identified as follows: larger DFV diameter 50 mm and 250 mm below lesser trochanter (8.73 ± 4.34 mm vs. 11.9 ± 3.52 mm; p = 0.043 and 5.4 ± 3.90 mm vs. 8.90 ± 2.70 mm; p = 0.011); lower FV/DFV ratio 150 mm below lesser trochanter (11.39 ± 20.01 mm vs. 1.05 ± 0.47 mm; p = 0.043); and presence of FV scarring/synechiae, collaterals and abnormal wall thickness (p = 0.003, p = 0.003 and p < 0.0001). Conclusion: In cases of extensive chronic iliofemoral venous obstruction, especially when stent deployment into the DFV is entertained, the key to success is thorough pre-procedure planning focusing on choosing the access site. This study suggests DCTV is valuable in defining the dominant iliac vein inflow, but additional findings are necessary to validate these preliminary data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of a Curved Electrode with Controllable Direction in the Radiofrequency Ablation of Liver Tumors Behind Large Vessels

Purpose: To investigate the role of a novel curved radiofrequency ablation (RFA) electrode with controllable direction in the ablation of tumors behind large hepatic vessels in ex vivo bovine and in vivo canine liver experiments. Materials and Methods: Approval from the institutional animal care and use committee was obtained. In ex vivo experiments, conventional multi-tines expandable electrodes, conventional monopolar straight electrodes and novel curved electrodes were used in the ablation of the bovine liver (n = 90). The ablated area, parallel axis, vertical axis and shape of different electrodes were compared. Then, 24 beagle dogs (10 months old, female) were used for in vivo experiments. Visual tumor targets deeply located in the portal vein were established, and ultrasound-guided liver ablation was performed with different electrodes. The ablation range, target coverage rate, percentage of normal tissue injury and damage to adjacent vessels were evaluated. The Kruskal–Wallis test and the Chi-squared test were used for statistical analysis. Results: For the ex vivo study with a 3-cm electrode, the ablation area of the multi-tines expandable electrode group (7.14 ± 0.16 cm{sup 2}) was significantly larger than that of the novel curved electrode group (5.01 ± 0.30 cm{sup 2}, P < 0.001) and the monopolar straight electrode group (5.43 ± 0.15 cm{sup 2}, P < 0.001). The results obtained with the 4-cm electrode in the three groups were in accordance with those of the 3-cm electrode. In vivo, the normal tissue damage area of the novel curved electrode group was smaller than that of the multi-tines expandable electrode group (1.10 ± 0.18 cm{sup 2} vs. 4.00 ± 0.18 cm{sup 2}, P < 0.001). The target coverage rate of the novel curved electrode group was better than that of the monopolar straight electrode group (100% vs. 80.86 ± 1.68%, P < 0.001). The hematoxylin and eosin (H&E) and TUNEL staining results showed that the ablation necrosis area was adjacent to large vessels, but the vascular wall was not significantly damaged in the novel curved electrode group. Conclusion: Our preliminary results showed that the novel curved RFA electrode with controllable direction could achieve accurate ablation for tumors behind large hepatic vessels, with a better target coverage rate and less damage to normal tissue, than conventional multi-tines expandable electrodes and monopolar straight electrodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Stochastic Study of Flow Anisotropy and Channelling in Open Rough Fractures

The quantification of fluid flow in rough fractures is of high interest for reservoir engineering, especially for deep geothermal applications. Herein, rough self-affine fractures are stochastically generated with incremental shear displacement and geometrically described by two aperture definitions, the vertical aperture a vert and the effective aperture a eff . In order to compare their effect on fracture flow, such as anisotropy and channelling, Local Cubic Law (LCL) model-based 2D fluid flow is simulated. The particularity of this approach is the combination of a stochastic generation of self-affine fractures with a statistical analysis (560 individual realizations) of the impact of the LCL’s aperture constraint on fracture flow. The results show that aperture definition affects the quantitative interpretation of flow anisotropy and channeling as well as the aperture distribution of the fractures with shearing. Higher values of mean aperture for a given fracture are found using a vert , whereas the aperture standard deviation is larger with a eff . In addition, flow anisotropy is significantly sensitive to aperture definition for small shear displacements and shows a relative higher dispersion with a eff . Thus, LCL prediction models based on a vert are expected to lead to higher dispersion of anisotropy results with a higher uncertainty (factor ~ 2). Realizations based on avert lead to an enhanced clustering of high flow rates for higher shearing displacements. This channeling development results in higher total flow rates for these simulations. Finally, these findings support the direct calibration of pre-existing LCL anisotropy simulations based on avert towards more representative results using a eff .

58 GEOSCIENCES↗

Geometry, spin coupling, and dielectric control of redox potentials in [4Fe–4S] Clusters

Iron–sulfur (Fe–S) clusters are common biological cofactors that facilitate vital redox reactions. Despite extensive research, the molecular basis of redox potential tuning in ferredoxin-like proteins remains an active area of debate. In this study, we combine statistical analysis of over one thousand [4Fe–4S]-containing protein structures from the Protein Data Bank (PDB) with broken-symmetry and extended broken-symmetry density functional theory to examine how cysteine ligand orientations and environmental screening affect redox properties of the clusters. We identified five main ligand configurations, three of which are predominant in natural structures. Among these, the adiabatic electron affinity differs by less than 0.1 V, indicating that, while geometry plays a secondary role, it allows localized fine-tuning of redox properties. In contrast, electrostatic and solvation effects primarily determine the overall potential range.

Computational Chemistry↗

Operational Efficiency Evaluation of a Setup for Removing Stresses in the Steam Header of PGV-1000 Steam Generator

The effectiveness of a setup for removing stresses in the steam header of a PGV-1000 steam generator is evaluated. The evaluation is based on an investigation of the stress state by means of magnetic anisotropy measurements performed in the zone of the No. 111 weld seam of the hot header of steam generators operating in one of the power-generating units with a V-320 series reactor arrangement. Inspections made it possible to obtain cartograms of the distribution of the difference of the principal mechanical stresses along the perimeter of the weld connection of a PGV-1000 header equipped with a cooling mantle and headers without such a mantle. By means of statistical analysis of the data, a diagram of the distribution of the principal mechanical stresses was obtained. In addition, the distribution of the standard deviation of the principal mechanical stresses as a measure of the dispersion of a random quantity relative to its mathematical expectation was determined.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Method of Determining the Reliability of Real-Time In-reactor Monitoring of VVER

A methodological approach and the basic tenets for evaluating the reliability of in-reactor monitoring of VVER are presented. The method is based on the statistical analysis of indications in real time and includes methods for evaluating the admissible maximum error of the measurement channels used for monitoring as well as the average value and admissible deviation of indications in groups of parallel monitoring channels, as well as a method of evaluating reliability by comparing the values of a parameter with the regime values. In comparing the indications of a monitoring channel with the indications of other parallel channels, the median value is proposed as the baseline value. The developed method is implemented in the Diagnostika SVRK special software, which has been successfully tested during the commissioning of the No. 1 unit at the Novovoronezh NPP-2.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cross-Combined Composite Sampling Designs for Identification of Elevated Regions

Analyzing soils for contaminants can be costly. Generally, discrete samples are gathered from within a study area, analyzed by a laboratory and the results are used in a site-specific statistical analysis. Because of the heterogeneities that exist in soil samples within study areas, a large amount of variability and skewness may be present in the sample population. This necessitates collecting a large number of samples to obtain reliable inference on the mean contaminant concentration and to understand the spatial patterns for future remediation. Composite or Incremental sampling is a commonly applied method for gathering multiple discrete samples and physically combining them, such that each combination of discrete samples requires a single laboratory analysis, which reduces cost and can improve the estimates of the mean concentration. While incremental sampling can reduce cost and improve mean estimates, current implementations do not readily facilitate the characterization of spatial patterns or the detection of elevated regions within study areas. The methods we present in this work provide efficient estimation and inference for the mean contaminant concentration over the entire spatial area and enable the identification of high contaminant regions within the area of interest. We develop sample design methodologies that explicitly define the characteristics of these designs (such as sample grid layout) and quantify the number of incremental samples that must be obtained under a design criteria to control false positive and false negative (Type I and II) decision errors. We present the sample design theory and specifications as well as results on simulated and real data.

Hathaway, John E↗

Deep-learning based artificial intelligence tool for melt pools and defect segmentation

Accelerating fabrication of additively manufactured components with precise microstructures is important for quality and qualification of built parts, as well as for a fundamental understanding of process improvement. Accomplishing this requires fast and robust characterization of melt pool geometries and structural defects in images. This paper proposes a pragmatic approach based on implementation of deep learning models and self-consistent workflow that enable systematic segmentation of defects and melt pools in optical images. Deep learning is based on an image-to-image translation–conditional generative adversarial neural network architecture. An artificial intelligence (AI) tool based on this deep learning model enables fast and incrementally more accurate predictions of the prevalent geometric features, including melt pool boundaries and printing-induced structural defects. We present statistical analysis of geometric features that is enabled by the AI tool, showing strong spatial correlation of defects and the melt pool boundaries. The correlations of widths and heights of melt pools with dataset processing parameters show the highest sensitivity to thermal influences resulting from laser passes in adjacent and subsequent layer passes. The presented models and tools are demonstrated on the aluminum alloy and datasets produced with different sets of processing parameters. However, they have universal quality and could easily be adapted to different material compositions. The method can be easily generalized to microstructural characterizations other than optical microscopy.

additive manufacturing↗

Statistical Characterization and Process Control for Improved Growth of La2−xSrxCuO4 Films

We have used combinatorial molecular beam epitaxy (COMBE) technique to deposit thin cuprate films with continuous spread in chemical composition, as well as nominally uniform films. We have patterned them into linear pixel arrays and measured the transport properties of each pixel. We applied detailed statistical analysis to differentiate between various possible sources of random pixel-to-pixel variations, and utilized this knowledge to considerably tighten the process parameters and significantly reduce such variations. The density and quality of data points is high enough to allow detection of quantum phase transitions induced by tuning the chemical composition.

36 MATERIALS SCIENCE↗

Very High Cycle Fatigue of a Cast Aluminum Alloy: Size Effect and Crack Initiation

Fatigue properties of an Al-Si-Cu cast alloy were investigated with life up to very high cycle fatigue regime. Particular attention was given to specimen size effect and fatigue crack initiation mechanism. Uniaxial fatigue tests with constant amplitudes were carried out by using ultrasonic fatigue testing machine operating at 20 kHz, compared to the results obtained by using conventional hydraulic fatigue machine at 35 Hz. In order to evaluate the size effect, two sets of specimens with different dimensions were used. The results show that the fatigue strength of the studied alloy decreases with the increase in specimen size. Scanning electron microscopy observation of fracture surfaces revealed that most fatigue cracks initiated from microstructural defects such as porosity located on specimen surface or in subsurface. Weibull statistical analysis of fatigue data accounting for size effect was performed to predict the fatigue life of the Al-Si-Cu alloy in the very high cycle regime. Good agreement was found between the fatigue life prediction and the experimental data.

36 MATERIALS SCIENCE↗

Pitting Corrosion of 10Ni8CrMoV High-Strength Steel Induced by a Potential Perturbation

Pitting corrosion of high-strength steel 10Ni8CrMoV under square wave polarization (SWP) in simulated deep-sea environment is investigated and the possible mechanism is proposed. The results show that potential perturbation generates periodic intensification effect on both anodic and cathodic processes by frequently breaking the electrode equilibrium state. The intensity of periodic intensification effect essentially depends on the concentration gradient of Fe{sup 2+} cations at the steel/solution interface which acts as the forced electrochemical oscillator. The concentration gradient and the resulting concentration polarization effect increase periodically with the increase in SWP potential range. The morphology observation of the pitting and electric charge calculation indicate that the periodic intensification effect can promote the initiation and growth of pits by enhancing the anodic dissolution even under cathodic protection, but it is ineffective below the hydrogen evolution potential. The decrease in either upper or lower potential can mitigate anodic dissolution. Through the statistical analysis of pitting size, it is found that the wide potential range tends to activate the metastable pitting formed under hydrostatic pressure, forming densely distributed pitting. Meanwhile, it is more favorable to the formation of fully grown pits with high size dispersion degree when the proportion of electric charge in the anodic process is higher.

36 MATERIALS SCIENCE↗

Relationship between Grain Size and Sample Thickness on the Creep-Rupture Performance of Thin Metallic Sheets of INCONEL Alloy 740H

A study was conducted on INCONEL® alloy 740H® to examine the role of grain size and sheet thickness on the alloy’s creep-rupture behavior. Three different starting sheet thicknesses were utilized and multiple heat-treatment conditions anticipated for compact heat exchanger (CHX) manufacturing were applied to produce a range of grain sizes. Creep-rupture testing was conducted at 750 °C for times up to about 6000 h and the results were compared to wrought databases. The data show that both creep strength and ductility were important factors in the overall creep performance of the sheets. Reductions in performance were observed due either to accelerated creep when grain size was fine or loss of rupture ductility when grain sizes approached the sheet thickness. Some combinations of heat-treatment and thickness were able to produce typical expected wrought creep properties. Historically a ‘rule-of-thumb’ requirement for creep testing suggests 3-5 grains per sample minimum dimension to ensure homogeneous behavior. This research shows that to ensure representative wrought creep performance (i.e. no effect of sample size), the sample minimum cross-section should be 10 times the average ASTM grain size. Statistical analysis of the microstructures suggests the population of larger grains as a controlling feature in creep failure.

14 SOLAR ENERGY↗

High-Throughput Statistical Interrogation of Mechanical Properties with Build Plate Location and Powder Reuse in AlSi10Mg

Abstract Additive manufacturing (AM) allows agile, rapid manufacturing of geometrically complex components that would otherwise be impossible through traditional manufacturing methods. With this maturing manufacturing technology comes the need to adopt testing methods that are commensurate with the speed of additive manufacturing and take advantage of its geometric flexibility. High-throughput tensile testing (HTT) is a technique that allows a large number of tensile bars to be tested in a short amount of time. In the present study, HTT is used to evaluate AM AlSi10Mg produced using powder bed fusion with a Renishaw AM250 machine. Three parameters were varied in this study: (1) powder reuse history, (2) location on the build plate, and (3) size of the tensile specimen. For all parameter combinations, at least 22 specimens were tested; in several cases, over 40 were tested. This large dataset, consisting of over 500 tensile tests, permits Weibull statistical analysis and provides sufficient fidelity to isolate subtle trends that would have likely been missed in smaller, traditional datasets. The observed trends are rationalized in terms of the role of porosity and surface crust on mechanical response.

Carroll, Jay D. (ORCID:0000000258184709)↗

On the Effect of Sphere-Overlap on Super Coarse-Grained Models of Protein Assemblies

Ion mobility mass spectrometry (IM/MS) can provide structural information on intact protein complexes. Such data, including connectivity and collision cross sections (CCS) of assemblies’ subunits, can in turn be used as a guide to produce representative super coarse-grained models. These models are constituted by ensembles of overlapping spheres, each representing a protein subunit. A model is considered plausible if the CCS and sphere-overlap levels of its subunits fall within predetermined confidence intervals. While the first is determined by experimental error, the latter is based on a statistical analysis on a range of protein dimers. Here, we first propose a new expression to describe the overlap between two spheres. Then we analyze the effect of specific overlap cutoff choices on the precision and accuracy of super coarse-grained models. Finally, we propose a method to determine overlap cutoff levels on a per-case scenario, based on collected CCS data, and show that it can be applied to the characterization of the assembly topology of symmetrical homo-multimers. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Image Processing Pipeline for Fluoroelastomer Crystallite Detection in Atomic Force Microscopy Images

Phase transformations in materials systems can be tracked using atomic force microscopy (AFM), enabling the examination of surface properties and macroscale morphologies. In situ measurements investigating phase transformations generate large datasets of time-lapse image sequences. The interpretation of the resulting image sequences, guided by domain-knowledge, requires manual image processing using handcrafted masks. Here this approach is time-consuming and restricts the number of images that can be processed. Her in this study, we developed an automated image processing pipeline which integrates image detection and segmentation methods. We examine five time-series AFM videos of various fluoroelastomer phase transformations. The number of image sequences per video ranges from a hundred to a thousand image sequences. The resulting image processing pipeline aims to automatically classify and analyze images to enable batch processing. Using this pipeline, the growth of each individual fluoroelastomer crystallite can be tracked through time. We incorporated statistical analysis into the pipeline to investigate trends in phase transformations between different fluoroelastomer batches. Understanding these phase transformations is crucial, as it can provide valuable insights into manufacturing processes, improve product quality, and possibly lead to the development of more advanced fluoroelastomer formulations.

36 MATERIALS SCIENCE↗