Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Study of the Melting Latent Heat of Semicrystalline PVDF applied to High Gamma Dose Dosimetry

Poly(vinylidene fluoride) homopolymers [PVDF] homopolymers were irradiated with gamma doses ranging from 0.5 to 2.75 MGy. Differential scanning calorimetry (DSC) and FTIR spectrometry were used in order to study the effects of gamma radiation in the amorphous and crystalline polymer structures. The FTIR data revealed absorption bands at 1730 and 1853 cm{sup -1} which were attributed to the stretch of C=O bonds, at 1715 and 1754 cm{sup -1} which were attributed to the C=C stretching and at 3518, 3585 and 3673 cm{sup -1} which were associated with NH stretch of NH{sub 2} and OH. The melting latent heat (LM) measured by DSC was used to construct an unambiguous relationship with the delivered dose. Regression analyses revealed that the best mathematical function that fits the experimental calibration curve is a 4-degree polynomial function, with an adjusted Rsquare of 0.99817. (authors)

36 MATERIALS SCIENCE↗

A Statistical Framework for Protein Quantitation in Bottom-Up MS-Based Proteomics

Motivation: Quantitative mass spectrometry-based proteomics requires protein-level estimates and associated confidence measures. Challenges include the presence of low quality or incorrectly identified peptides and informative missingness. Furthermore, models are required for rolling peptide-level information up to the protein level. Results: We present a statistical model that carefully accounts for informative missingness in peak intensities and allows unbiased, model-based, protein-level estimation and inference. The model is applicable to both label-based and label-free quantitation experiments. We also provide automated, model-based, algorithms for filtering of proteins and peptides as well as imputation of missing values. Two LC/MS datasets are used to illustrate the methods. In simulation studies, our methods are shown to achieve substantially more discoveries than standard alternatives. Availability: The software has been made available in the opensource proteomics platform DAnTE (http://omics.pnl.gov/software/). Contact: adabney@stat.tamu.edu Supplementary information: Supplementary data are available at Bioinformatics online.

59 BASIC BIOLOGICAL SCIENCES↗

East River Pore Water FTICR-MS Data associated with "Geomorphic and Hydrogeochemical Controls on Fine-Scale Hyporheic Microbiome Assembly and Function"

Pore water samples were collected from distributed locations around Meander A in East River (Crested Butte, CO, USA) during the summer of 2018. This dataset consists of the characterization of dissolved organic matter using 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS; in .xml format) analyzed through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory).This study aimed to understand organic matter assemblages differ within a streambed with differing geomorphology and the interplay between streambed organic matter and microbiome function. Any published work that utilizes data presented in this dataset should cite the dataset using the DOI number. If using the dataset, please acknowledge the U.S. Department of Energy (DOE) Office of Science (BER) Subsurface Biogeochemical Research (SBR) program, the Environmental Molecular Sciences Laboratory (EMSL), and Worldwide Hydrobiogeochemical Observation Network for Dynamic River Systems (WHONDRS). The publication DOI will be added to this abstract when available.

54 ENVIRONMENTAL SCIENCES↗

NanoSIMS imaging reveals unexpected heterogeneity in nutrient uptake by brown adipocytes

Highlights: • The uptake of nutrients by brown adipocytes is heterogeneous. • Mass spectrometry–based imaging was used to quantify nutrient uptake. • Uptake of chylomicron-derived lipids by brown adipocytes varied > fourfold. • Uptake of glucose and fatty acids by brown adipocytes varied by ∼2.3-fold. • Data imply heterogeneity in the intrinsic metabolic properties of brown adipocytes. Heterogeneity in the metabolic properties of adipocytes in white adipose tissue has been well documented. We sought to investigate metabolic heterogeneity in adipocytes of brown adipose tissue (BAT), focusing on heterogeneity in nutrient uptake. To explore the possibility of metabolic heterogeneity in brown adipocytes, we used nanoscale secondary ion mass spectrometry (NanoSIMS) to quantify uptake of lipids in adipocytes interscapular BAT and perivascular adipose tissue (PVAT) after an intravenous injection of triglyceride-rich lipoproteins (TRLs) containing [{sup 2}H]triglycerides ({sup 2}H-TRLs). The uptake of deuterated lipids into brown adipocytes was quantified by NanoSIMS. We also examined {sup 13}C enrichment in brown adipocytes after administering [{sup 13}C]glucose or {sup 13}C-labeled mixed fatty acids by gastric gavage. The uptake of {sup 2}H-TRLs-derived lipids into brown adipocytes was heterogeneous, with {sup 2}H enrichment in adjacent adipocytes varying by more than fourfold. We also observed substantial heterogeneity in {sup 13}C enrichment in adjacent brown adipocytes after administering [{sup 13}C]glucose or [{sup 13}C]fatty acids by gastric gavage. The uptake of nutrients by adjacent brown adipocytes within a single depot is variable, suggesting that there is heterogeneity in the metabolic properties of brown adipocytes.

60 APPLIED LIFE SCIENCES↗

Image segmentation for uranium isotopic analysis by SIMS: Combined adaptive thresholding and marker controlled watershed approach

A novel approach to particle identification and particle isotope ratio determination has been developed for nuclear safeguard applications. This particle search approach combines an adaptive thresholding algorithm and marker-controlled watershed segmentation (MCWS) transform, which improves the secondary ion mass spectrometry (SIMS) isotopic analysis of uranium containing particle populations for nuclear safeguards applications. The Niblack assisted MCWS approach (a.k.a. SEEKER) developed for this work has improved the identification of isotopically unique uranium particles under conditions that have historically presented significant challenges for SIMS image data processing techniques. Particles obtained from five NIST uranium certified reference materials (CRM U129A, U015, U150, U500 and U850) were successfully identified in regions of SIMS image data 1) where a high variability in image intensity existed, 2) where particles were touching or were in close proximity to one another and/or 3) where the magnitude of ion signal for a given region was count limited. Analysis of the isotopic distributions of uranium containing particles identified by SEEKER showed four distinct, accurately identified 235U enrichment distributions, corresponding to the NIST certified 235U/238U isotope ratios for CRM U129A/U015 (not statistically differentiated), U150, U500 and U850. Additionally, comparison of the minor uranium isotope (234U, 235U and 236U) atom percent values verified that, even in the absence of high precision isotope ratio measurements, SEEKER could be used to segment isotopically unique uranium particles from SIMS image data. Although demonstrated specifically for SIMS analysis of uranium containing particles for nuclear safeguards, SEEKER has application in addressing a broad set of image processing challenges.

adaptive thresholding↗

Flying Blind, or Just Flying Under the Radar? The Underappreciated Power of De Novo Methods of Mass Spectrometric Peptide Identification

Mass spectrometry-based proteomics is a popular and powerful method for precise and highly multiplexed protein identification. The most common method of analyzing untargeted proteomics data is called database searching, where the database is simply a collection of protein sequences from the target organism, derived from genome sequencing. Experimental peptide tandem mass spectra are compared to simplified models of theoretical spectra calculated from the translated genomic sequences. However, in several interesting application areas, such as forensics, archaeology, venomics and others, a genome sequence may not be available, or the correct genome sequence to use is not known. In these cases, de novo peptide identification can play an important role. De novo peptide identification infers peptide sequence directly from the tandem mass spectrum without reference to a sequence database, usually using graph-based or machine learning algorithms. In this review, we provide a basic overview of de novo peptide identification methods and applications, briefly covering de novo algorithms and tools, and focusing in more depth on recent applications from venomics, metaproteomics, forensics, and characterization of antibody drugs.

proteomics, mass spectrometry, forensics, de novo ↗

Sputter-Deposited Mo Thin Films: Multimodal Characterization of Structure, Surface Morphology, Density, Residual Stress, Electrical Resistivity, and Mechanical Response

Multimodal datasets of materials are rich sources of information which can be leveraged for expedited discovery of process–structure–property relationships and for designing materials with targeted structures and/or properties. For this data descriptor article, we provide a multimodal dataset of magnetron sputter-deposited molybdenum (Mo) thin films, which are used in a variety of industries including high temperature coatings, photovoltaics, and microelectronics. In this dataset we explored a process space consisting of 27 unique combinations of sputter power and Ar deposition pressure. Here, the phase, structure, surface morphology, and composition of the Mo thin films were characterized by x-ray diffraction, scanning electron microscopy, atomic force microscopy, and Rutherford backscattering spectrometry. Physical properties—namely, thickness, film stress and sheet resistance—were also measured to provide additional film characteristics and behaviors. Additionally, nanoindentation was utilized to obtain mechanical load-displacement data. The entire dataset consists of 2072 measurements including scalar values (e.g., film stress values), 2D linescans (e.g., x-ray diffractograms), and 3D imagery (e.g., atomic force microscopy images). An additional 1889 quantities, including film hardness, modulus, electrical resistivity, density, and surface roughness, were derived from the experimental datasets using traditional methods. Minimal analysis and discussion of the results are provided in this data descriptor article to limit the authors’ preconceived interpretations of the data. Overall, the data modalities are consistent with previous reports of refractory metal thin films, ensuring that a high-quality dataset was generated. The entirety of this data is committed to a public repository in the Materials Data Facility.

36 MATERIALS SCIENCE↗

Clinical potential of mass spectrometry-based proteogenomics

Cancer genomics research aims to advance personalized oncology by finding and targeting genetic alterations associated with cancers. In genome-driven oncology, treatments are selected for individual patients based on the genomic sequence of their tumor. This personalized oncology approach has prolonged survival for subsets of cancer patients. However, many patients do not respond to the predicted therapies based on genomic profiles of their tumors. Recent studies pairing genomic and proteomic analyses in the same tumors have shown that the proteome encodes novel information that is not discerned through genomic analysis alone. This has led to the concept of “proteogenomics,” in which both types of data are leveraged for a more complete view of tumor biology that may more effectively match cancer patients to efficacious treatments. Technological advances in methods for quantifying proteins, including targeted mass spectrometry, have opened a path for the clinical translation of proteogenomic findings into clinical research. We discuss the added value of a combined proteogenomics approach over the current genome-centric approach in characterizing human cancers, and summarize current efforts to incorporate targeted proteomic measurements based on multiple reaction monitoring mass spectrometry (MRM) into the clinical laboratory to facilitate clinical proteogenomics.

Zhang, Bing↗

Unique & challenging aspects of plutonium metal standards exchange program for actinide measurements

The Los Alamos National Laboratory exchange program is the only program of its kind for the distribution of plutonium (Pu) standards materials with a range of impurity contents to multiple laboratories for destructive measurements of elemental concentration. This paper discusses statistical methods used to address challenges in Pu metal exchange data by way of two case studies. Challenges include how to evaluate a data set when a large fraction of the values are minimum detection limits (MDLs), and how to determine potential outliers with limited in-formation on the true spread of the data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contaminant profiles in Southeast Asian immigrants consuming fish from polluted waters in northeastern Wisconsin

Recent immigrants to the USA from Southeast Asia may be at higher risk of exposure to fish-borne contaminants including polychlorinated biphenyls (PCBs), p, p'-dichlorodiphenyldichloroethene (DDE) and methylmercury (MeHg) because of their propensity to engage in subsistence fishing. Exposure to contaminants was assessed in men and women of Hmong descent living in Green Bay, Wisconsin, where the Fox River and lower Green Bay are contaminated with PCBs, and to a lesser extent with mercury. Serum samples from 142 people were analyzed for PCBs and p,p'-DDE by capillary column gas chromatography with electron capture detection (ECD). Whole blood was analyzed for total mercury by cold vapor atomic absorption spectrometry and atomic fluorescence spectroscopy. Lipid-adjusted total PCB concentrations ranged from 8.7 to 3,091 ng/g (full range of the data), with a geometric mean of 183.6 ng/g (estimated after eliminating one outlier). DDE ranged from 0.3 to 7,083 (full range of the data) with a geometric mean of 449.8 ng/g (estimated after eliminating two outliers). Men had higher PCB and DDE concentrations than women. Serum PCB concentrations were significantly correlated with fish consumption (r=0.43, p<0.0001), whereas DDE concentrations were not (r=0.09,p=0.29). Instead, serum DDE was strongly associated with the number of years spent in a Thai refugee camp before immigrating to the USA (r=0.60;p<0.0001). PCB congeners 138, 153, 118 and 180 accounted for a smaller percentage of the total PCBs than has been reported in other fish-eating populations, and several lightly chlorinated congeners were present in relatively large amounts. Mercury exposure was low in this population. In conclusion, Hmong immigrants in northeastern Wisconsin are at risk of elevated PCB exposure from consumption of locally caught fish. The pattern of exposure is somewhat different than patterns in other fish-eating populations, possibly due to use of Aroclor 1242 by the paper industry in this region.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Resolution Desorption Electrospray Ionization Mass Spectrometry for Chemical Characterization of Organic Aerosols

Characterization of the chemical composition and chemical transformations of secondary organic aerosol (SOA) is both a major challenge and the area of greatest uncertainty in current aerosol research. This study presents the first application of desorption electrospray ionization combined with high-resolution mass spectrometry (DESI-MS) for detailed chemical characterization and studies of chemical aging of OA collected on Teflon substrates. DESI-MS offers unique advantages both for detailed characterization of chemically labile components in OA that cannot be detected using more traditional electrospray ionization mass spectrometry (ESI-MS) and for studying chemical aging of OA. DESI-MS enables rapid characterization of OA samples collected on substrates by eliminating the sample preparation stage. In addition, it enables detection and structural characterization of chemically labile molecules in OA samples by minimizing the residence time of analyte in the solvent. SOA produced by the ozonolysis of limonene (LSOA) was allowed to react with gaseous ammonia. Chemical aging resulted in measurable changes in the optical properties of LSOA observed using UV- visible spectroscopy. DESI-MS combined with tandem mass spectrometry experiments (MS/MS) enabled identification of species in aged LSOA responsible for absorption of the visible light. Detailed analysis of the experimental data allowed us to identify chemical changes induced by reactions of LSOA constituents with ammonia and distinguish between different mechanisms of chemical aging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methods and Challenges in the Determination of Molecular Weight Metrics of Bio-oils

The analyses of thermochemically-derived bio-oil properties and composition are challenging due to the diversity of compounds present and the reactivity of the oils. There are currently a variety of techniques used and no standard method established for the analysis of the molecular weight distribution, weight average molecular weight (Mw) and other molecular weight metrics of bio-oils. This review focuses on the challenges and variation in methodologies employed for the analysis of bio-oils on the basis of molecular weight, particularly by gel permeation chromatography (GPC). GPC is the most practical means for determination of molecular weight metrics of bio-oils but needs to be refined using appropriate standards and/or detectors to ensure consistency and accurate quantification of molecular weight metrics. Future method development for a robust technique with accurate and comparable molecular weight data should focus on GPC with multiple detection methodology on whole bio-oils, verified relative to another technique such as mass spectrometry (MS). MS techniques, such as Fourier transform-ion cyclotron resonance (FT-ICR MS), have also been utilized for the determination of molecular weight distribution of bio-oils and are briefly addressed in this review. Many MS methods can provide extensive characterization and structural speciation of components in bio-oils, and while accurate molecular weight metrics can be obtained with the appropriate use of ionization techniques and optimized parameters to ensure appropriate range of m/z and signals representative of abundance, MS is not a robust or an economically practical method for routine molecular weight analyses. Physical separation techniques such as preparative scale GPC, distillation, and liquid-liquid extraction methods are also briefly addressed in this review in the context of molecular weight analyses.

09 BIOMASS FUELS↗

Light Exposure Promotes Degradation of Intermediates and Growth of Phosphine-Ligated Gold Clusters

Subnanometer clusters exhibit unique properties not observed at the bulk or nanometer scale. Many applications, however, require clusters to be monodisperse in size and composition.While substantial progress has been made empirically on producing specific-sized gold clusters using different ligands, the mechanisms of cluster formation remain insufficiently understood. Using high mass-resolution electrospray ionization mass spectrometry (ESI-MS), we characterized the formation of cationic triphenylphosphine-ligated gold clusters [Aux(PPh3)y z+] in solution. Our data provides evidence that small hydrogen-containing intermediate “building blocks” (i.e., Au2(PPh3)2H+, Au4(PPh3)4H+, and Au7(PPh3)7H5 2+) are responsible for the growth of larger gold clusters (i.e., Au6(PPh3)6 2+ and Au8(PPh3)7 2+) over several hours. In addition, intermediate degradation and cluster growth are shown to be dependent on irradiation of the reacting solution with light. Specifically, the rate of growth of large clusters is demonstrated to scale with the intensity of light exposure. Complementary theoretical calculations were also performed that provide molecular-level insight into the nature of the bonding between the hydrogens and gold atoms in the intermediate Au-phosphine clusters. Collectively, our joint experimental and theoretical findings advance the understanding of the factors at play in the size-selective synthesis of ligated gold clusters in solution.

Hewitt, Michael A.↗

Production of {sup 177}Lu, a potential radionuclide for diagnostic and therapeutic applications

{sup 177g}Lu (T{sub 1/2}=6.647d; E{sub β{sup −max}}=498.3KeV, I{sub β{sup −total}}=100%; E{sub γ} = 112.9498 keV, I{sub γ} = 6.17%; E{sub γ} = 208.3662 keV, I {sub γ} = 10.36%) is widely used in many clinical procedures due to its excellent decay characteristics. Production cross-sections of the {sup nat}Yb(d,x){sup 177g}Lu reactions have been measured from a 24-MeV deuteron energy down to the threshold by using a stacked-foil activation technique combined with high resolution γ-ray spectrometry. An overall good agreement is found with some of the earlier measurements, whereas a partial agreement is obtained with the theoretical data extracted from the TENDL-2013 library. Physical thick target yield for the {sup 177g}Lu radionuclide was deduced using the measured cross-sections. The deduced yield curves indicate that a low energy (<11 MeV) cyclotron and a highly enriched {sup 176}Yb target could be used to obtain {sup 177g}Lu with negligible impurity from {sup 177m}Lu.

07 ISOTOPE AND RADIATION SOURCES↗

Cyclotron produced {sup 67}Ga, a potential radionuclide for diagnostic and therapeutic applications

Production cross-sections of the {sup nat}Zn(d,x){sup 67}Ga reactions have been measured from a 24-MeV deuteron energy down to the threshold by using a stacked-foil activation technique combined with HPGe γ-ray spectrometry. An overall good agreement is found with some of the earlier measurements, whereas a partial agreement is obtained with the theoretical data extracted from the TENDL-2013 library. Physical thick target yield for the {sup 67}Ga radionuclide was deduced using the measured cross-sections, and found in agreement with the directly measured yield available in the literature. This study reveals that a low deuteron energy (<11 MeV) cyclotron and an enriched {sup 66}Zn target could be used to obtain {sup 67}Ga in no carrier added form.

07 ISOTOPE AND RADIATION SOURCES↗

Neutral gas analysis for JET DT operation

Neutral gas analysis, the measurement and evaluation of total and partial pressures, is a key technique to study the impact of neutral gas dynamics on retention, recycling and release processes of fuel or impurity species in fusion devices. At JET, the experiment closest to ITER in terms of operating parameters and size, various detectors and techniques for partial pressure and total pressure measurements are deployed together to characterise neutral gas dynamics during and after plasma operation on various toroidal and poloidal locations. An extensive modification of JET's sub-divertor neutral gas diagnostic system aims at retaining and extending established measurement capabilities in the forthcoming Deuterium-Tritium (DT) experiments (DTE2). To achieve DT compatibility, a separation of radiation-sensitive electronics from the sensor and adequate radiation shielding is required, as well as utilisation of a DT compatible differential pumping system with adjustable throughput to account for the strong pressure variation in the sub-divertor region. Finally, the sub-divertor neutral gas diagnostic will be equipped with multiple Residual Gas Analysers (RGAs), utilising quadrupole mass spectrometry and electrostatic ion-trap-principles, all operating with remote electronics located behind the biological radiation shield. These RGAs will record data in a fast selected discrete mass mode during plasma pulses (cycle ~2 s) and will automatically switch back to continuous data recording (cycle ~100 s) afterwards. They will be complemented by a newly improved Penning gauge spectroscopy configuration in particular supporting the He and D 2 separation relevant for DT operation. The distance between these devices and their associated control unit is typically 15m . A newly developed RGA with a cable length of 80 m, compatible with the ITER environment, will also be employed for the first time. Finally, this set-up and its operation in DTE2 will provide vital input to the development of the ITER divertor RGA in the most relevant environment currently available.

47 OTHER INSTRUMENTATION↗

Improved genome annotation through untargeted detection of pathway-specific metabolites

Background: Mass spectrometry-based metabolomics analyses have the potential to complement sequence-based methods of genome annotation, but only if raw mass spectral data can be linked to specific metabolic pathways. In untargeted metabolomics, the measured mass of a detected compound is used to define the location of the compound in chemical space, but uncertainties in mass measurements lead to “degeneracies” in chemical space since multiple chemical formulae correspond to the same measured mass. We compare two methods to eliminate these degeneracies. One method relies on natural isotopic abundances, and the other relies on the use of stableisotope labeling (SIL) to directly determine C and N atom counts. Both depend on combinatorial explorations of the “chemical space” comprised of all possible chemical formulae comprised of biologically relevant chemical elements. Results: Of 1532 metabolic pathways curated in the MetaCyc database, 412 contain a metabolite having a chemical formula unique to that metabolic pathway. Thus, chemical formulae alone can suffice to infer the presence of some metabolic pathways. Of 248,928 unique chemical formulae selected from the PubChem database, more than 95% had at least one degeneracy on the basis of accurate mass information alone. Consideration of natural isotopic abundance reduced degeneracy to 64%, but mainly for formulae less than 500 Da in molecular weight, and only if the error in the relative isotopic peak intensity was less than 10%. Knowledge of exact C and N atom counts as determined by SIL enabled reduced degeneracy, allowing for determination of unique chemical formula for 55% of the PubChem formulae. Conclusions: To facilitate the assignment of chemical formulae to unknown mass-spectral features, profiling can be performed on cultures uniformly labeled with stable isotopes of nitrogen (15N) or carbon (13C). This makes it possible to accurately count the number of carbon and nitrogen atoms in each molecule, providing a robust means for reducing the degeneracy of chemical space and thus obtaining unique chemical formulae for features measured in untargeted metabolomics having a mass greater than 500 Da, with relative errors in measured isotopic peak intensity greater than 10%, and without the use of a chemical formula generator dependent on heuristic filtering. These chemical formulae can serve as indicators for the presence of particular metabolic pathways.

59 BASIC BIOLOGICAL SCIENCES↗