Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “silicon detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Fabrication of an Absorber-Coupled MKID Detector and Readout for Sub-Millimeter and Far-Infrared Astronomy

We have fabricated absorber-coupled microwave kinetic inductance detector (MKID) arrays for sub-millimeter and farinfrared astronomy. Each detector array is comprised of lambda/2 stepped impedance resonators, a 1.5μm thick silicon membrane, and 380μm thick silicon walls. The resonators consist of parallel plate aluminum transmission lines coupled to low impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The Al transmission lines simultaneously act to absorb optical power and are designed to have a surface impedance and filling fraction so as to match the impedance of free space. Our novel fabrication techniques demonstrate high fabrication yield of MKID arrays on large single crystal membranes and sub-micron front-to-back alignment of the microstrip circuit.

far-infrared↗

Images of the future - Two decades in astronomy

Future instruments for the 100-10,000 A UV-wavelength region will require detectors with greater quantum efficiency, smaller picture elements, a greater wavelength range, and greater active area than those currently available. After assessing the development status and performance characteristics of vidicons, image tubes, electronographic cameras, digicons, silicon arrays and microchannel plate intensifiers presently employed by astronomical spacecraft, attention is given to such next-generation detectors as the Mosaicked Optical Self-scanned Array Imaging Camera, which consists of a photocathode deposited on the input side of a microchannel plate intensifier. The problems posed by the signal processing and data analysis requirements of the devices foreseen for the 21st century are noted.

Weistrop, D.↗

Microwave Power Detection With Voltage-Gated Graphene

Commercially available, chemical vapor deposition grown, graphene has been used to realizevoltage-gate tunable, microwave power detectors. Corbino disc structures with chrome/gold contacts havebeen fabricated on top of graphene deposited on P-type silicon substrates with silicon dioxide gate oxides.Devices of varying sizes were used to detect a 433.92 MHz signal. These test structures exhibited a peak power detection sensitivity of 3.25 mV/mW at 292 K and 5.43 mV/mW at 80 K. The improved graphene detectors exceed the sensitivity of previously reported graphene detectors, 0.86 mV/mW, as well as previously explored carbon nanotube bolometers, 0.36 mV/mW

Michael R. Gasper↗

The Event Detection System in the NEXT-White Detector

This article describes the event detection system of the NEXT-White detector, a 5 kg high pressure xenon TPC with electroluminescent amplification, located in the Laboratorio Subterráneo de Canfranc (LSC), Spain. The detector is based on a plane of photomultipliers (PMTs) for energy measurements and a silicon photomultiplier (SiPM) tracking plane for offline topological event filtering. The event detection system, based on the SRS-ATCA data acquisition system developed in the framework of the CERN RD51 collaboration, has been designed to detect multiple events based on online PMT signal energy measurements and a coincidence-detection algorithm. Implemented on FPGA, the system has been successfully running and evolving during NEXT-White operation. The event detection system brings some relevant and new functionalities in the field. A distributed double event processor has been implemented to detect simultaneously two different types of events thus allowing simultaneous calibration and physics runs. This special feature provides constant monitoring of the detector conditions, being especially relevant to the lifetime and geometrical map computations which are needed to correct high-energy physics events. Other features, like primary scintillation event rejection, or a double buffer associated with the type of event being searched, help reduce the unnecessary data throughput thus minimizing dead time and improving trigger efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Polarimetry with an Active-Matrix Pixel Proportional Counter

We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33+/- 0.03, confirming previous reports of the high polarization sensitivity of a finely segmented pixel proportional counter. The detector described here has a geometry suitable for the focal plane of an astronomical X-ray telescope. Amorphous silicon readout technology will enable additional extensions and improvements.

Black, J. K.↗

The AMACStar ASIC for the HL-LHC ATLAS ITk Strip detector: design, verification, testing, and quality assurance

For the high-luminosity upgrade to the LHC (HL-LHC), the ATLAS detector at CERN requires an all-new inner detector, the Inner Tracker (ITk). The ITk Strip subdetector is made up of silicon modules, which include three types of radiation-hard ASICs. One of these is the Autonomous Monitor and Control (AMAC). The AMAC is manufactured by Global Foundries using 130 nm CMOS8RF DM technology and is approximately 3 by 5 mm in size. This ASIC autonomously monitors the temperatures, voltages, and currents in the module components while controlling critical values in order to prevent these quantities from reaching dangerous levels. The final design, AMACStar, was verified, tested, and ensured to perform all necessary functions. A quality control procedure using an in-house probe station set-up was developed in order to ensure that every individual chip on each wafer of AMACStars required by the ITk Strip project met performance requirements. The average per wafer yield of usable AMACStars is 92.33%, exceeding the design-specific 90% yield estimated for project costing. This estimate was based on actual yields for similar designs in this process.

Analogue electronic circuits↗

A silicon surface barrier telescope for solar particles identification

From the results three conclusions can be made: (1) the detector system described and tested is capable of good charge resolution from He to Al although beyond Ne the statistic is very poor; (2) in the high gain mode, isotopic resolution has been achieved for Li-6/Li-7 Be-7/Be-9; (3) the much higher yield of He over He and of Be-9 over Be-10 in these types of nuclear reactions prevents obtaining experimental evidence of those isotopes, although it is believed that, at least He-3/He-4 can be resolved under other more favorable conditions (i.e., solar He-3-rich events).

Sequeiros, J.↗

Novel multi-channel skipper-CCD packages for dark matter searches

The next generation of skipper Charge Coupled Device (skipper-CCD) experiments for rare-event searches will bring new challenges for the packaging and read-out of the detectors. Scaling the active mass and simultaneously reducing the experimental backgrounds in two orders of magnitude will require a novel high-density Silicon-based package, that must be massively produced and stored. In this work, we present the design, first production, and testing of multi-channel Silicon packages with photon shielding, along with the outlook for the next steps toward producing 1500 wafers that will add up to a 10 kg skipper-CCD detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon Photo-Multiplier Readouts for Scintillators in High-Energy Astronomy

New scintillator materials have recently been shown to hold great potential for low-cost, reliable gamma-ray detectors in high-energy astronomy. New devices for the detection of scintillation light promise to make scintillator-based instruments even more attractive by reducing mass and power requirements,in particular, silicon photo-multipliers (SiPMs) are starting to become commercially available that offer gains and quantum efficiencies similar to those of photo-multiplier tubes (PMTs), but with greatly reduced mass, high ruggedness, low voltage requirements, and no sensitivity to magnetic fields. We have conducted laboratory tests of a sample of commercially available SiPMs coupled to LaBr3;Ce, a scintillator of relevance to to future high-energy astrophysics missions. We present results for gamma-ray spectroscopy. compare the SiPM performance to that of a PMT, and discuss the extent to which SiPMs offer significant advantages for scintillator-based space missions.

Bloser, Peter F.↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗

WIRE-21 Experiment Irradiation Conditions and In-Situ Data Collection

This report summarizes the in situ data collected during three cycles of irradiation (~75 days) of the Wireless Instrumented Removable Beryllium Experiment 2021 (WIRE-21) in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR). The experiment was designed primarily to evaluate the effects of high neutron flux and fluence on the performance of wireless temperature and pressure sensors being developed by Westinghouse Electric Company (WEC). WEC’s sensors could provide critical data regarding the evolution of centerline temperatures and pressurization due to fission gas release during fuel operation in light-water reactors (LWRs) or various advanced reactor applications. In addition to WEC’s wireless sensors, many other sensors were interrogated, including thermocouples, self-powered neutron detectors (SPNDs), distributed fiber optic temperature sensors, and passive neutron flux wires and silicon carbide thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

Camera memory study for large space telescope

Specifications were developed for a memory system to be used as the storage media for camera detectors on the large space telescope (LST) satellite. Detectors with limited internal storage time such as intensities charge coupled devices and silicon intensified targets are implied. The general characteristics are reported of different approaches to the memory system with comparisons made within the guidelines set forth for the LST application. Priority ordering of comparisons is on the basis of cost, reliability, power, and physical characteristics. Specific rationales are provided for the rejection of unsuitable memory technologies. A recommended technology was selected and used to establish specifications for a breadboard memory. Procurement scheduling is provided for delivery of system breadboards in 1976, prototypes in 1978, and space qualified units in 1980.

Hoffman, C. P.↗

Fabrication of an Absorber-Coupled MKID Detector and Readout for Sub-Millimeter and Far-Infrared Astronomy

We have fabricated absorber-coupled microwave kinetic inductance detector (MKID) arrays for sub-millimeter and far-infrared astronomy. Each detector array is comprised of lambda/2 stepped impedance resonators, a 1.5 micrometer thick silicon membrane, and 380 micrometer thick silicon walls. The resonators consist of parallel plate aluminum transmission lines coupled to low impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The Al transmission lines simultaneously act to absorb optical power and are designed to have a surface impedance and filling fraction so as to match the impedance of free space. Our novel fabrication techniques demonstrate high fabrication yield of MKID arrays on large single crystal membranes and sub-micron front-to-back alignment of the microstrip circuit.

Brown, Ari-David↗

The Solar Neutron TRACking (SONTRAC) Instrument for the Detection of Fast Neutrons

Fast neutrons (energies >0.5 MeV) contribute to the radiation exposure of space hardware and astronaut crew, enable greater understanding of planetary atmospheric and surface compositions and allow unique measurements of solar particle acceleration. Neutrons are challenging to detect and measurements of them typically suffer from high background rates. High energy neutrons (>50 MeV) pose even more challenges, because the traditional double-scatter technique based on a time-of-flight (ToF) measurement. These measurements are challenging due to size constraints on satellites, particularly newer small satellites. The SOlar Neutron TRACking instrument (SONTRAC) is a small satellite neutron detector that utilizes fine-grained scintillating fiber bundles with 1-mm pitch silicon photomultiplier (SiPM) array readout. Signal processing is accomplished with multichannel ASICs. SONTRAC is able to image fast neutron (between 20-200 MeV) scatters in a compact scalable package. We discuss below the numerous applications of this technology and recent progress on the development and performance characteristics of the prototype instrument.

Georgia A de Nolfo↗

4-Dimensional Trackers

4-dimensional (4D) trackers with ultra fast timing (10-30 ps) and very fine spatial resolution (O(few $\mu$m)) represent a new avenue in the development of silicon trackers, enabling new physics capabilities beyond the reach of the existing tracking detectors. This paper reviews the impact of integrating 4D tracking capabilities on several physics benchmarks both in potential upgrades of the HL-LHC experiments and in several detectors at future colliders, and summarizes the currently available sensor technologies as well as electronics, along with their limitations and directions for R$\&$D.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro-Spec: an Integrated, Direct-Detection Spectrometer for Far-Infrared and Submillimeter Astronomy

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

microwave kinetic inductance detectors (MKIDs)↗

Design of a Cryogenic Scintillation Neutrino Detector at the Spallation Neutron Source

We successfully verified in the following three aspects the feasibility of using a cryogenic scintillating crystal-based neutrino detector at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, for the detection of low-mass dark matter particles and non-standard neutrino interactions (NSIs), as part of the detector R&D effort of the COHERENT experiment. First, we demonstrated the possibility of using silicon photomultipliers (SiPMs) at cryogenic temperatures to replace traditional photomultiplier tubes (PMTs) as light sensors. Second, we verified that the high light yield of undoped CsI crystals measured above 13 keVee at 77 K still holds down to 5.9 keVee. Third, we successfully measured nuclear quenching factor of undoped cryogenic CsI at the Triangle Universities Nuclear Laboratory with the help from our Duke collaborators. The first achievement resulted in a publication in European Physics Journal C. The second resulted in an arXiv pre-print, which is under journal review. The last one indicates that the performance of the proposed detector may be better than what was assumed in the literature. The analysis is in the final stage and will result in another journal publication. In addition, two graduate students involved in this project graduated with master’s degrees during the project period. Both decided to continue their research as PhD students. One open-source data analysis code package was created and is publicly available on GitHub. A set of tutorials about Monte Carlo simulation of radiation interacting with detectors were created on YouTube, receiving more than 100,000 views.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗