Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Machine learning-based ethylene concentration estimation, real-time optimization and feedback control of an experimental electrochemical reactor

With the increase in electricity supply from clean energy sources, electrochemical reduction of carbon dioxide (CO 2 ) has received increasing attention as an alternative source of carbon-based fuels. As CO 2 reduction is becoming a stronger alternative for the clean production of chemicals, the need to model, optimize and control the electrochemical reduction of the CO 2 process becomes inevitable. However, on one hand, a first-principles model to represent the electrochemical CO 2 reduction has not been fully developed yet because of the complexity of its reaction mechanism, which makes it challenging to define a precise state-space model for the control system. On the other hand, the unavailability of efficient concentration measurement sensors continues to challenge our ability to develop feedback control systems. Gas chromatography (GC) is the most common equipment for monitoring the gas product composition, but it requires a period of time to analyze the sample, which means that GC can provide only delayed measurements during the operation. Moreover, the electrochemical CO 2 reduction process is catalyzed by a fast-deactivating copper catalyst and undergoes a selectivity shift from the product-of-interest at the later stages of experiments, which can pose a challenge for conventional control methods. To this end, machine learning (ML) techniques provide a potential approach to overcome those difficulties due to their demonstrated ability to capture the dynamic behavior of a chemical process from data. Motivated by the above considerations, we propose a machine learning-based modeling methodology that integrates support vector regression and first-principles modeling to capture the dynamic behavior of an experimental electrochemical reactor; this model, together with limited gas chromatography measurements, is employed to predict the evolution of gas-phase ethylene concentration. The model prediction is directly used in a proportional-integral (PI) controller that manipulates the applied potential to regulate the gas-phase ethylene concentration at energy-optimal set-point values computed by a real-time process optimizer (RTO). Specifically, the RTO calculates the operation set-point by solving an optimization problem to maximize the economic benefit of the reactor. Finally, suitable compensation methods are introduced to further account for the experimental uncertainties and handle catalyst deactivation. The proposed modeling, optimization, and control approaches are the first demonstration of active control for a CO 2 electrolyzer and contribute to the automation and scale-up efforts for electrified manufacturing of fuels and chemicals starting from CO 2 .

42 ENGINEERING↗

Electrochemical Detection of Oxycodone and Its Main Metabolites with Nafion-Coated Single-Walled Carbon Nanotube Electrodes

Oxycodone is a strong opioid frequently used as an analgesic. Although proven efficacious in the management of moderate to severe acute pain and cancer pain, use of oxycodone imposes a risk of adverse effects such as addiction, overdose, and death. Fast and accurate determination of oxycodone blood concentration would enable personalized dosing and monitoring of the analgesic as well as quick diagnostics of possible overdose in emergency care. However, in addition to the parent drug, several metabolites are always present in the blood after a dose of oxycodone, and to date, there is no electrochemical data available on any of these metabolites. In this paper, a single-walled carbon nanotube (SWCNT) electrode and a Nafion-coated SWCNT electrode were used, for the first time, to study the electrochemical behavior of oxycodone and its two main metabolites, noroxycodone and oxymorphone. Both electrode types could selectively detect oxycodone in the presence of noroxycodone and oxymorphone. However, we have previously shown that addition of a Nafion coating on top of the SWCNT electrode is essential for direct measurements in complex biological matrices. Therefore, in this work, the Nafion/SWCNT electrode was further characterized and used for measuring clinically relevant concentrations of oxycodone in buffer solution. The limit of detection for oxycodone with the Nafion/SWCNT sensor was 85 nM, and the linear range was 0.5–10 μM in buffer solution. Furthermore, this study shows that the fabricated Nafion/SWCNT sensor has potential to be applied in clinical concentration measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multifunctional Nanowire/film Composites based Bi-modular Sensors for In-situ and Real-time High Temperature Gas Detection

This final report to the Department of Energy/National Energy Technology Laboratory for DE-FE0000870 covers the period from 2009 to June, 2013 and summarizes the main research accomplishments, which can be divided in sensing materials innovation, bimodular sensor demonstration, and new understanding and discoveries. As a matter of fact, we have successfully completed all the project tasks in June 1, 2013, and presented the final project review presentation on the 9th of July, 2013. Specifically, the major accomplishments achieved in this project include: 1) Successful development of a new class of high temperature stable gas sensor nanomaterials based on composite nano-array strategy in a 3D or 2D fashion using metal oxides and perovskite nanostructures. 2) Successful demonstration of bimodular nanosensors using 2D nanofibrous film and 3D composite nanowire arrays using electrical resistance mode and electrochemical electromotive force mode. 3) Series of new discoveries and understandings based on the new composite nanostructure platform toward enhancing nanosensor performance in terms of stability, selectivity, sensitivity and mass flux sensing. In this report, we highlight some results toward these accomplishments.

47 OTHER INSTRUMENTATION↗

Ultrasensitive biochemical sensing device and method of sensing analytes

Systems and methods biochemically sense a concentration of a ligand using a sensor having a substrate having a metallic nanoparticle array formed onto a surface of the substrate. A light source is incident on the surface. A matrix is deposited over the nanoparticle array and contains a protein adapted to binding the ligand. A detector detects s-polarized and p-polarized light from the reflective surface. Spacing of nanoparticles in the array and wavelength of light are selected such that plasmon resonance occurs with an isotropic point such that -s and -p polarizations of the incident light result in substantially identical surface Plasmon resonance, wherein binding of the ligand to the protein shifts the resonance such that differences between the -S and -P polarizations give in a signal indicative of presence of the ligand.

47 OTHER INSTRUMENTATION↗

Interface Characterization within a Nuclear Fuel Plate

To predict the performance of nuclear fuels and materials, irradiated fuel plates must be characterized efficiently and accurately in highly radioactive environments. The characterization must take place remotely and work in settings largely inhospitable to modern digital instrumentation. Characterization techniques based on non-contacting laser sensing methods enable remote operation in a robust manner within a hot-cell environment. Laser characterization instrumentation can offer high spatial resolution and remain effective for scanning large areas. A laser shock (LS) system is currently being developed as a post-irradiation examination (PIE) technique in the hot fuel examination facility (HFEF) at the Idaho National Laboratory (INL). The laser shock technique will characterize material properties and failure loads/mechanisms in various composite components and materials such as plate fuel and next-generation fuel forms in high radiation areas. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel–clad bond. As part of the laser shock system, a laser-based ultrasonic C-scan system will be used to detect and characterize debonding caused by the application of the laser shock. The laser shock system has been used to characterize the resulting bond strength within plate fuels which have been fabricated using different fabrication processes. The results of this study will be to select the fabrication process that provides the strongest interface.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Robust fluorescent calcium coordination polymers as Cu 2+ sensors with high sensitivity and fast response

A three-dimensional (3D) and highly fluorescent calcium-based coordination polymer (Ca-CP) has been synthesized and structurally characterized. Furthermore, built on a strongly fluorescent (FL) chromophore ligand, [Ca(H 2 tcbpe)(H 2 O) 2 ] (1) (H 4 tcbpe = 4',4''',4''''',4'''''''-(ethene-1,1,2,2-tetrayl)tetrakis(([1,1'-biphenyl]-4-carboxylic acid))) is highly luminescent. Photoluminescence (PL) studies indicate that 1 undergoes a bathochromic shift in emission energy from blue to green color upon outgassing or under mechanic force. Notably, 1 exhibits selective FL sensing for Cu 2+ ions with a detection limit (LOD) of 0.064 ppm, far below the U.S. WHO and EPA standard for drinking water. Detailed investigation of the sensing mechanism reveals that uncoordinated COO– groups in 1 play a major role in recognizing Cu 2+ ions.

36 MATERIALS SCIENCE↗

Design of a portable optical emission tomography system for microwave induced compact plasma for visible to near-infrared emission lines

A new non-invasive diagnostic system is developed for Microwave Induced Plasma (MIP) to reconstruct tomographic images of a 2D emission profile. A compact MIP system has wide application in industry as well as research application such as thrusters for space propulsion, high current ion beams, and creation of negative ions for heating of fusion plasma. Emission profile depends on two crucial parameters, namely, the electron temperature and density (over the entire spatial extent) of the plasma system. Emission tomography provides basic understanding of plasmas and it is very useful to monitor internal structure of plasma phenomena without disturbing its actual processes. This paper presents development of a compact, modular, and versatile Optical Emission Tomography (OET) tool for a cylindrical, magnetically confined MIP system. It has eight slit-hole cameras and each consisting of a complementary metal–oxide–semiconductor linear image sensor for light detection. The optical noise is reduced by using aspheric lens and interference band-pass filters in each camera. The entire cylindrical plasma can be scanned with automated sliding ring mechanism arranged in fan-beam data collection geometry. The design of the camera includes a unique possibility to incorporate different filters to get the particular wavelength light from the plasma. This OET system includes selected band-pass filters for particular argon emission 750 nm, 772 nm, and 811 nm lines and hydrogen emission H{sub α} (656 nm) and H{sub β} (486 nm) lines. Convolution back projection algorithm is used to obtain the tomographic images of plasma emission line. The paper mainly focuses on (a) design of OET system in detail and (b) study of emission profile for 750 nm argon emission lines to validate the system design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a lab-scale, high-resolution, tube-generated X-ray computed-tomography system for three-dimensional (3D) materials characterization

The design and construction of a modular high resolution X-ray computed tomography (XCT) system is highlighted in this paper. The design approach is detailed for meeting a specified set of instrument performance goals tailored towards experimental versatility and high resolution imaging. The XCT tool is unique in the detector and X-ray source design configuration, enabling control in the balance between detection efficiency and spatial resolution. The system package is also unique: The sample manipulation approach implemented enables a wide gamut of in situ experimentation to analyze structure evolution under applied stimulus, by optimizing scan conditions through a high degree of controllability. The component selection and design process is detailed: Incorporated components are specified, custom designs are shared, and the approach for their integration into a fully functional XCT scanner is provided. Custom designs discussed include the dual-target X-ray source cradle which maintains position and trajectory of the beam between the two X-ray target configurations with respect to a scintillator mounting and positioning assembly and the imaging sensor, as well as a novel large-format X-ray detector with enhanced adaptability. The instrument is discussed from an operational point of view, including the details of data acquisition and processing implemented for 3D imaging via micro-CT. The performance of the instrument is demonstrated on a silica-glass particle/hydroxyl-terminated-polybutadiene (HTPB) matrix binder PBX simulant. Post-scan data processing, specifically segmentation of the sample's relevant microstructure from the 3D reconstruction, is provided to demonstrate the utility of the instrument. - Highlights: • Custom built X-ray tomography system for microstructural characterization • Detector design for maximizing polychromatic X-ray detection efficiency • X-ray design offered for maximizing X-ray flux with respect to imaging resolution • Novel lab-scale XCT data acquisition and data processing methods • 3D characterization of glass-bead mock plastic-bonded-explosive stimulant.

36 MATERIALS SCIENCE↗

Chiral response of a twisted bilayer of hexagonal boron nitride

Here, we propose a bilayer structure made of two twisted hexagonal boron nitride (hBN) slabs for realizing tunable chirality in this work. Our numerical results show that a maximum circular dichroism as high as 0.84 can be achieved with the bilayer structure. The chiral response of the proposed structure comes from the combined effects of polarization conversion of circularly polarized wave with the top slab and selective transmission of linearly polarized wave with the bottom slab. Besides, the chirality can be actively controlled by adjusting the optic axis orientation of the top hBN slab. Finally, the bilayer structure is possible to be built with other suitable materials, metamaterials and microstructures for functioning chiral response in different wavebands. Therefore, the results in this work may provide some important hints for the design of novel chiral response sensors for optical, chemical and biological sensing.

42 ENGINEERING↗

Synthesis and utilization of carbon nanotubes for fabrication of electrochemical biosensors

Graphical abstract: Carbon nanotubes. - Highlights: • This review discusses synthesis and applications of carbon nanotubes sensors. • The review summarizes contributions of carbon nanotube to electrochemical biosensor. • Good electrical conductivity makes carbon nanotubes a good material for biosensors. • Carbon nanotubes promotes electron transfer that aids biosensing of biomolecules. - Abstract: This review summarizes the most recent contributions in the fabrication of carbon nanotubes-based electrochemical biosensors in recent years. It discusses the synthesis and application of carbon nanotubes to the assembly of carbon nanotube-based electrochemical sensors, its analytical performance and future expectations. An increasing number of reviews and publications involving carbon nanotubes sensors have been reported ever since the first design of carbon nanotube electrochemical biosensors. The large surface area and good electrical conductivity of carbon nanotubes allow them to act as “electron wire” between the redox center of an enzyme or protein and an electrode's surface, which make them very excellent material for the design of electrochemical biosensors. Carbon nanotubes promote the different rapid electron transfers that facilitate accurate and selective detection of cytochrome-c, β-nicotinamide adenine dinucleotide, hemoglobin and biomolecules, such as glucose, cholesterol, ascorbic acid, uric acid, dopamine pesticides, metals ions and hydrogen peroxide.

36 MATERIALS SCIENCE↗

Highly birefringent suspended-core photonic microcells for refractive-index sensing

An in-line photonic microcell with a highly birefringent suspended microfiber core is fabricated by locally heating and pressurizing selected air-holes of an endless single mode photonic crystal fiber. The microfiber core has rhombus-like cross-sectional geometry and could achieve a high birefringence of up to 10{sup −2}. The microfiber core is fixed at the center of the microcell by thin struts attached to an outer jacket tube, which protects and isolates the microfiber from environmental contaminations. Highly sensitive and robust refractive index sensors based on such microcells are experimentally demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3-D Volumetric Gamma-ray Imaging and Source Localization with a Mobile Robot - 18124

Radiation detection has largely been a manual inspection process with point sensors such as Geiger-Muller counters and scintillation spectrometers to date. While their observations of source proximity prove useful, they lack the directional information necessary for efficient source localization and characterization in cluttered environments with multiple radiation sources. The recent commercialization of Compton gamma cameras provides directional information to the broader radiation detection community for the first time. This paper presents the integration of a Compton gamma camera with a self-localizing ground robot for accurate 3D radiation mapping. Using the position and orientation of the robot, radiation images from the gamma camera are accumulated over a traversed path in a shared frame of reference to construct a consistent voxel grid-based radiation map. The peaks of the map at pre-specified energy windows are selected as the source location estimates, which are compared to the ground truth source locations. The proposed approach localizes multiple sources to within an average of 0.2 m in two 5 x 4 m{sup 2} and 14 x 6 m{sup 2} laboratory environments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accelerated Irradiation Testing and Post-Irradiation Characterization: U.S.-Based Capabilities for Advanced Nuclear Systems and Radioisotope Production

Irradiation experiments and post-irradiation examinations, together referred to as irradiation testing (IRT), are prerequisites for nuclear fuel and material qualification for the deployment of new and advanced reactors, as well as radioisotope production, thereby ensuring regulatory compliance. Qualified research and test reactors (RTRs) and testing facilities are essential to enable IRT to verify performance and safety under prototypical reactor conditions. In the past, qualification of new fuels or structural materials required about 20 years. Synergist strategies, advanced tools, and qualified methods are needed to greatly reduce this timeframe of IRT and radioisotope production. This study, termed accelerated-IRT, focuses on identifying gaps and leveraging U.S.-based RTRs and material testing capabilities, leveraging the preliminary evaluation and qualification of selected RTRs to provide a generic as well as specific-case solution paths forward, ensuring adherence to stringent regulatory standards. Furthermore, IRT and radioisotope production utilizing qualified RTRs necessarily includes modeling and simulation to support the design (i.e. neutronics, thermal, and structural aspects) and manufacturing of irradiation test specimens, vehicles, capsules, apparatuses, and flow loops. In addition, IRT can be improved by applying advanced manufacturing techniques and in-pile sensors and instrumentation, as discussed in this study.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation-Hardened Circuitry Using Mask-Programmable Analog Arrays (September 2014 Milestone Report)

This is a report of the activities involving Task 2 of the NEET 2 project Radiation Hardened Circuitry Using Mask-Programmable Analog Arrays. Using the analog blocks available in our currently pre-configured Via-Configured Array (VCA), we will perform a detailed schematic design of our system to include the signal-processing blocks for temperature, radiation and pressure. Control and data acquisition will be implemented with the Spartan-6 Field-Programmable Gate Array (FPGA) as well as wired serial communications with a remote computer to be used with this project. In addition, batteries and associated voltage regulators will be selected for powering the system. Fabrication may include a polyimide, printed circuit board (PCB) for improved radiation and temperature tolerance. The PCB will go through a layout process by one of the organizations we utilize for this function and be fabricated by another external vendor. Population of the system board will be performed using one of our in-house technicians or an outside vendor we commonly use. Five prototype systems (sensors, electronics board, battery power supply, and personal computer (PC) serial communications port) will be constructed to support the testing objectives of this work. Quality assurance will be performed at each step by both the submitters and the vendors.

36 MATERIALS SCIENCE↗

Advanced Manufacturing for Thermal and Environmental Control Systems: Achieving National Energy Goals

This project was part of a regional initiative in the five counties of Central New York (CNY) that received funding from the U.S. Department of Energy (DOE) and four other federal agencies through the 2012 Advanced Manufacturing Jobs and Innovation Accelerator Challenge (AMJIAC). The CNY initiative was focused on cultivating the emergent regional cluster in “Advanced Manufacturing for Thermal and Environmental Control (AM-TEC).” As one component of the CNY AM-TEC initiative, the DOE-funded project supported five research & development seed projects that strategically targeted: 1) needs and opportunities of CNY AM-TEC companies, and 2) the goal of DOE’s Advanced Manufacturing Office (AMO) to reduce energy consumption by 50% across product life-cycles over 10 years. The project also sought to fulfill the AMO mission of developing and demonstrating new, energy-efficient processing and materials technologies at a scale adequate to prove their value to manufacturers and spur investment. The five seed projects demonstrated technologies and processes that can reduce energy intensity and improve production as well as use less energy throughout their lifecycles. The project was conducted over three years in two 18-month budget periods. During the first budget period, two projects proposed in the original AMJAIC application were successfully completed: Seed Project 1 focused on saving energy in heat transfer processes via development of nano structured surfaces to significantly increase heat flux; Seed Project 2 addressed saving energy in data centers via subzero cooling of the computing processors. Also during the first budget period, a process was developed and executed to select a second round of seed projects via a competitive request for proposals from regional companies and university collaborators. Applicants were encouraged to form industry-academic partnerships to leverage experience and resources of public and private sectors in the CNY region. Proposals were evaluated by a national panel of experts. Three projects were selected for awards and were completed successfully during the second budget period: Seed Project 3 focused on enabling self-powered furnaces to permit residents to shelter in place during power outages; Seed Project 4 addressed development of a novel method of controlling air conditioning systems that could enable flexible load matching in market segments not possible with existing technologies; and Seed Project 5 focused on the creation of smarter occupancy sensors to enable effective highly localized demand based ventilation.

30 DIRECT ENERGY CONVERSION↗

Sensors with Intelligent Measurement Platform for Monitoring and Control in Distribution Circuits

This paper presents a medium-voltage intelligent measurement platform that provides post-processing of raw measurements received from commercially-available voltage/current sensors to enhance accuracy and bandwidth of the monitoring system. Furthermore, this platform integrates into a Data Distribution Service (DDS) messaging bus for distributed control and interoperability. The authors present the design, specifications, and major components included in the platform, and argue for applications and use cases that most benefit from this new approach. A laboratory testbed has been created to demonstrate the functionality, for which test results are presented for selected test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quenching of photoluminescence in a Zn-MOF sensor by nitroaromatic molecules

We uncover the exact mechanisms that lead to a quenching of the photoluminescence in a Zn-based metal organic framework (MOF) material upon nitroaromatic molecule adsorption. We present evidence based on ab initio simulations, coupled with in situ IR spectroscopy and photoluminescence measurements, showing that quenching occurs as the result of a shift of the lowest unoccupied orbital from the MOF host to the guest molecule. Our results provide a mechanistic understanding of quenching of photoluminescence in MOFs and are of importance for chemical sensing applications, where they aid the design of novel MOFs with increased sensing selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗