Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample preparation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

The Thermodynamics of Crystallization and Phase-Separation in Melt-Derived Nuclear Waste Forms

This project aimed to gain detailed and fundamental understanding of the stability of glass waste forms to be used for safe and reliable encapsulation of nuclear waste. The focus was to understand thermodynamic and structural properties involved in crystallization and phase separation in melt-derived waste form glasses and glass-ceramics by studying a baseline glass composition with varying additives. This was achieved by combining neutron total scattering, advanced calorimetric measurements, and extensive modeling study. This project harnessed diverse and complementary approaches and expertise from four collaborating interdisciplinary institutions (two universities, one national laboratory, and one UK university partner). Samples were prepared at the national laboratory and exchanged with the two university institutions. The thermodynamic data obtained by various advanced calorimetry techniques were linked to the underlying short-range structure of waste forms measured by state-of-the-art neutron total scattering experiments. An important element of this project was extensive modeling to interpret and fundamentally understand the experimental results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A new capability facilitating nuclear materials research: the Activated Materials Laboratory at the Advanced Photon Source

The Activated Materials Laboratory (AML), located in the Long Beamline Building (LBB) of the Advanced Photon Source (APS) of Argonne National Laboratory (ANL), serves as a centralized radiological facility for preparing radioactive samples for APS beamline experiments. The AML is equipped to receive shipments, handle open-form radioactive materials, encapsulate samples, and transport samples to-and-from beamline end-stations. The AML works closely with users and the APS radiological safety committee to make sure the safe conduct of experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

193 mIr/ 192 Ir ratio from irradiation with various NCERC critical assemblies

Eight irradiations of K 2 IrCl 6 pellets were carried out with three critical assemblies: Flattop-Oy, Flattop-Pu and Godiva IV. One of the irradiations was performed with three pellets at different locations of the critical assembly, while the other irradiations with pellets at the center, but operating the critical assembly at different power and, respectively, different neutron flux. Counting samples were prepared from the irradiated pellets and X-ray spectra measured with silicone drift detectors. The 193 mIr/ 192 Ir ratio is reported for each irradiation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ATOMIC Simulations and Experimental Data for Basalt-like Compounds

This data consists of simulations and experimental measurements of laser-induced breakdown spectroscopy (LIBS). The simulations are produced by ATOMIC, a general purpose plasma modeling and kinetics code that has been designed to compute emission (or absorption) spectra from plasmas [2]. The makeup of the plasma was considered to be divided into some proportion water, some proportion Martian atmosphere (CO2), and some proportion target (from the rock or object impacted by the laser), where these proportions add to 1. Based on expert knowledge, the proportion of water was kept in the range [0.0,0.5] and the proportion of atmosphere was kept in the range [0.02, 0.9]. Our overall suite of simulations contains six sets of simulations that differ in which elements were considered to make up the target. Within each set, we used uniformly drawn temperatures and log mass densities within pre-specified ranges. The temperature range was [0.5,1.5] eV and the log (base 10) mass density range was [-7,-4]. The proportion of water, atmosphere, and target were drawn from a symmetric Dirichlet distribution, but draws in which the propor- tion of water or atmosphere exceeded the pre-specified limits were rejected from the design. Up to eleven constituent elements (Si, Al, Fe, Mg, Ca, O, Ti, Mn, Na, K, P) were considered for the target, as they are the most common elements found in basalt compounds and were used in [1]. For each run, the proportions of the constituent elements making up the target were drawn from a symmetric Dirichlet distribution. We ran 1,350 simulations that included nonzero proportions of all eleven elements. We also ran simulations which excluded some of these elements. In particular, we ran 1,000 simulations that only included nonzero proportions for the six most common elements (Si, Al, Fe, Mg, Ca, O). We also ran five sets, each with 500 simulations, that only included nonzero proportions for five of the six most common elements (but where all sets included O). Thus, we generated a total of 4,850 spectra representing basalt-like compounds in which the target was comprised of oxygen and between four and ten other elements. The ATOMIC code produced spectra over a range of 240nm - 880nm that roughly mimics the range collected by the ChemCam instrument on the Mars rover Curiosity. Each spectra had 32,000 wavelengths split across three spectrometer ranges (to mimic ChemCam). The experimental data, described in [1], measures a prepared basalt sample. All files are kept in directories whose names indicate the set of elements considered for the target with file names numbered to indicate the line in the design files used to produce the simulation. The designs are provided as text files with names indicating their purpose. The experimental data is provided as a CSV file which contains a header with measurement information, followed by a collection of 50 shots across a collection of wavelengths, along with the computed median and mean across shots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cellulose crystallinity index (CrI) of switchgrass measured by solid-state NMR

Here we present a curated dataset of switchgrass cellulose crystallinity index (CrI) measured using solid state nuclear magnetic resonance (NMR) spectroscopy. Seventy-two topline switchgrass lines grown in greenhouse were collected and ground to -20/+80 mesh. The switchgrass was then Soxhlet-extracted with toluene/ethanol for 24 h to remove extractives. The extractives-free switchgrass was holopulped by using peracetic acid at 5 g loading per g biomass and the solution consistency was adjusted to 5% with DI water. Holopulping was conducted at room temperature for 24 h with stirring. The obtained holocellulose was washed excessively with DI water and air-dried at room temperature for 24 h. The dried holocellulose was treated with hydrochloric acid (2.5 M) for 2 h to remove hemicellulose. The isolated cellulose was collected by filtration, rinsed with DI water, and used to analyze cellulose crystallinity by solid-state NMR. The NMR samples were prepared by packing the moisturized cellulose into 4-mm cylindrical Zirconia MAS rotors. Cross polarization/magic angle spinning (CP/MAS) NMR analysis of cellulose was carried out on a Bruker Avance III 400-MHz spectrometer operating at 100.59 MHz for 13C in a Bruker double-resonance MAS probe head at spinning speeds of 8 kHz. The CP/MAS experiments utilized a 5 ms (90°) proton pulse, 1.5 ms contact pulse, 4 s recycle delay and 4000 scans. The cellulose crystallinity index was determined from the areas of the cellulose crystalline C4 signal (δ 86-92 ppm) over the entire C4 regions (δ 79-92 ppm) in the NMR spectra.

Cellulose, crystallinity index, switchgrass, solid↗

Investigation of the thermal decomposition of Pu(IV) oxalate: a transmission electron microscopy study

The degradation of the internal structure of plutonium (IV) oxalate during calcination was investigated with Transmission Electron Microscopy (TEM), electron diffraction, Electron Energy-Loss Spectroscopy (EELS), and 4D Scanning TEM (STEM). TEM lift-outs were prepared from samples that had been calcined at 300°C, 450°C, 650°C and 950°C. The resulting phase at all calcination temperatures was identified as PuO 2 with electron diffraction. The grain size range was obtained with high-resolution TEM. In addition, 4D STEM images were analyzed to provide grain size distributions. In the 300°C calcined sample, the grains were <10 nm in diameter, at 650°C, the grains ranged from 10 to 20 nm, and by 950°C, the grains were 95–175 nm across. Using the Kolmogorov-Smirnov (K-S) two sample test, it was shown that morphological measurements obtained from 4D-STEM provided statistically significant distributions to distinguish samples at the different calcination conditions. Using STEM-EELS, carbon was shown to be present in the low temperature calcined samples associated with oxalate but had formed carbon (possibly graphite) deposits in the 950°C calcined sample. This work highlights the new methods of STEM-EELS and 4D-STEM for studying the internal structure of special nuclear materials (SNM).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detection of Foreign Materials on Broiler Breast Meat Using a Fusion of Visible Near-Infrared and Short-Wave Infrared Hyperspectral Imaging

Foreign material (FM) found on a poultry product lowers the quality and safety of the product. We developed a fusion method combining two hyperspectral imaging (HSI) modalities in the visible-near infrared (VNIR) range of 400–1000 nm and the short-wave infrared (SWIR) range of 1000–2500 nm for the detection of FMs on the surface of fresh raw broiler breast fillets. Thirty different types of FMs that could be commonly found in poultry processing plants were used as samples and prepared in two different sizes (5 × 5 mm 2 and 2 × 2 mm 2 ). The accuracies of the developed Fusion model for detecting 2 × 2 mm 2 pieces of polymer, wood, and metal were 95%, 95%, and 81%, respectively, while the detection accuracies of the Fusion model for detecting 5 × 5 mm 2 pieces of polymer, wood, and metal were all 100%. The performance of the Fusion model was higher than the VNIR- and SWIR-based detection models by 18% and 5%, respectively, when F1 scores were compared, and by 38% and 5%, when average detection rates were compared. The study results suggested that the fusion of two HSI modalities could detect FMs more effectively than a single HSI modality.

36 MATERIALS SCIENCE↗

An A- and B-Site Substitutional Study of SrFeO3−δ Perovskites for Solar Thermochemical Air Separation

An A‑ and B‑site substitutional study of SrFeO3−δ perovskites (A’xA1−xB’yB1−yO3−δ, where A = Sr and B = Fe) was performed for a two‑step solar thermochemical air separation cycle. The cycle steps encompass (1) the thermal reduction of A’xSr1−xB’yFe1−yO3−δ driven by concentrated solar irradiation and (2) the oxidation of A’xSr1−xB’yFe1−yO3−δ in air to remove O2, leaving N2. The oxidized A’xSr1−xB’yFe1−yO3−δ is recycled back to the first step to complete the cycle, resulting in the separation of N2 from air and concentrated solar irradiation. A-site substitution fractions between 0 ≤ x ≤ 0.2 were examined for A’ = Ba, Ca, and La. B-site substitution fractions between 0 ≤ y ≤ 0.2 were examined for B’ = Cr, Cu, Co, and Mn. Samples were prepared with a modified Pechini method and characterized with X-ray diffractometry. The mass changes and deviations from stoichiometry were evaluated with thermogravimetry in three screenings with temperature- and O2 pressure-swings between 573 and 1473 K and 20% O2/Ar and 100% Ar at 1 bar, respectively. A’ = Ba or La and B’ = Co resulted in the most improved redox capacities amongst temperature- and O2 pressure-swing experiments.

14 SOLAR ENERGY↗

Bismuth Subcarbonate Decorated Reduced Graphene Oxide Nanocomposite for the Sensitive Stripping Voltammetry Analysis of Pb(II) and Cd(II) in Water

In this paper, bismuth subcarbonate (BiO)2CO3-reduced graphene oxide nanocomposite incorporated in Nafion matrix ((BiO)2CO3-rGO-Nafion) was synthesized and further applied, for the first time, in the sensitive detection of Pb(II) and Cd(II) by square-wave anodic stripping voltammetry (SWASV). The as-synthesized nanocomposites were characterized by energy-dispersive spectroscopy (EDS), Raman spectroscopy, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). (BiO)2CO3 composite plays a key role in the improvement of the detection sensitivity, which can form multicomponent alloy with cadmium and lead. Additionally, the unique structure of rGO can enlarge the surface area and provide abundant active sites. Moreover, Nafion incorporation in the nanocomposite can effectively increase the adhesion and mechanical strength of the film, and further improve the preconcetration ability due to the cation-exchange capacity of its abundant sulfonate groups. As expected, the (BiO)2CO3-rGO/Nafion nanocomposite-modified glassy carbon electrode ((BiO)2CO3-rGO-Nafion/GCE) achieved low detection limits of 0.24 μg/L for Pb(II) and 0.16 μg/L for Cd(II), in the linear range of 1.0–60 μg/L, and showed some excellent performance, such as high stability, good selectivity, and sensitivity. Finally, synthetic water samples were prepared and further used to verify the practicability of the (BiO)2CO3-rGO-Nafion/GCE with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Engineering cellular metabolism for targeted biosynthesis can require extensive design-build-test-learn (DBTL) cycles as the engineer works around the cell's survival requirements. Alternatively, carrying out DBTL cycles in cell-free environments can accelerate this process and alleviate concerns with host compatibility. A promising approach to cell-free metabolic engineering (CFME) leverages metabolically active crude cell extracts as platforms for biomanufacturing and for rapidly discovering and prototyping modified proteins and pathways. Realizing these capabilities and optimizing CFME performance requires methods to characterize the metabolome of lysate-based cell-free platforms. That is, analytical tools are necessary for monitoring improvements in targeted metabolite conversions and in elucidating alterations to metabolite flux when manipulating lysate metabolism. In this work, metabolite analyses using high-performance liquid chromatography (HPLC) coupled with either optical or mass spectrometric detection were applied to characterize metabolite production and flux in E. coli S30 lysates. Specifically, this report describes the preparation of samples from CFME lysates for HPLC analyses using refractive index detection (RID) to quantify the generation of central metabolic intermediates and by-products in the conversion of low-cost substrates (i.e., glucose) to various high-value products. The analysis of metabolite conversion in CFME reactions fed with 13 C-labeled glucose through reversed-phase liquid chromatography coupled to tandem mass spectrometry (MS/MS), a powerful tool for characterizing specific metabolite yields and lysate metabolic flux from starting materials, is also presented. Altogether, applying these analytical methods to CFME lysate metabolism enables the advancement of these systems as alternative platforms for executing faster or novel metabolic engineering tasks.

59 BASIC BIOLOGICAL SCIENCES↗

Altering translation allows E. coli to overcome chemically stabilized G-quadruplexes

Genomic DNA from each sample was prepared using the Wizard Genomic DNA Purification Kit (Promega) and after, DNA was quantified using the QuantiFluor ONE dsDNA System (Promega). Genomic DNA underwent shearing to ~200 bp fragments via sonication and the gDNA fragments were prepared for sequencing using the NEBNext Ultra II DNA Library Prep Kit for Illumina (NEB). Bead-based size selection was used to select ~200 bp fragments and the fragments then underwent a splinkerette PCR using a Tn5-enriching forward primer and custom reverse primers for multiplexing. A final bead-based size selection was used to select for the correct length DNA. DNA was sequenced at the University of Michigan Advanced Genomics Core using Illumina sequencing with a custom read primer reading the last 10 nt of the transposon. PhiX174 DNA spike was added to the run to ensure sufficient sequence diversity on the flow cell. Then, a custom index read primer and standard Illumina primer were used to sequence the index reads and PhiX174, respectively.

Keck, James L.↗

Diazotroph diversity across a land-management gradient

Soil diazotrophs are ubiquitous bacteria and archaea responsible for converting atmospheric nitrogen into plant-available ammonium. This process, if properly harnessed, can ameliorate excessive fertilizer inputs in conventional agricultural systems. However, the effect of diazotroph biodiversity on free-living nitrogen fixation (FLNF) is poorly understood. Here, we characterized diazotroph biodiversity across a land-management intensity gradient, determining the interactive effects of land management and diazotroph biodiversity on their ecosystem functioning (FLNF). Subsequently, we evaluated the functional redundancy of diazotroph biodiversity on FLNF in-vitro by performing a biodiversity reduction assay with chloroform fumigation, incubating soils with chloroform for either 24 or 72 hours. We estimated diazotroph biodiversity for both in-situ and chloroform-fumigated samples by preparing and sequencing nifH gene libraries. The raw sequencing data of our nifH library is deposited here.

Kristy, Brandon↗

Infrared absorptivities of transition metals at room and liquid-helium temperatures.

Evaluation of experimental data concerning the normal spectral absorptivities of the transition metals, nickel, iron, platinum, and chromium, at both room and liquid-helium temperatures in the wavelength range from 2.5 to 50 microns. The absorptivities were derived from reflectivity measurements made relative to a room-temperature vapor-deposited gold reference mirror. The absorptivity of the gold reference mirror was measured calorimetrically, by use of infrared laser sources. Investigation of various methods of sample-surface preparation resulted in the choice of a vacuum-annealing process as the final stage. The experimental results are discussed on the basis of the anomalous-skin-effect theory modified for multiple conduction bands. As predicted, the results approach a single-band model toward the longer wavelengths. Agreement between theory and experiment is considerably improved by taking into account the modification of the relaxation time due to the photon-electron-phonon interaction proposed by Holstein (1954) and Gurzhi (1958); but, particularly at helium temperatures, the calculated curve is consistently below the experimental results.

Jones, M. C.↗

Superconductivity in sputtered CuMO6S8

Samples were prepared by melting the metals, followed by annealing to various temperatures. The result was a structurally weak material. Sputtered films on sapphire substrates were prepared and studied. The substrates give the films mechanical strength and permit easy attachment of electrical leads. Materials were characterized by X-ray diffraction, electron microscopy, electrical resistance vs. temperature, and critical current measurements. Some of the results on CuMo6S8 are presented.

Alterovitz, S.↗

X-ray topographic observations of magnetic domains in Czochralski-grown nickel single crystals in anomalous transmission geometry

The anomalous transmission effect has been observed in nickel single crystals grown by the Czochralski technique. Sample crystals prepared for X-ray topography are 1.5 to 2.5 cm in diameter and thicker than 0.4 mm; the product of the ordinary linear absorption coefficient and thickness ranges from 17 to 45 for Cu K-alpha radiation. Topographs taken with an asymmetric-crystal-topographic (ACT) camera have revealed extremely straight line images and rectangular arrangements of short line-segment images, along with the images of crystal imperfections. The line images change their arrangement upon application of magnetic fields. These images are attributed to magnetic domains in the interior of crystals. The formation of domain walls near the crystal surface is also observed and distinguished clearly from magnetic domains in the bulk with the use of the ACT camera.

Kuriyama, M.↗

Origin of 78235, a lunar norite cumulate

A chemical and petrographic study is reported of the phases from the rock 78235 which was returned on the Apollo 17 mission. Petrographic analysis of the thin sections from the bounder confirm its cumulate origin. In order to develop further the crystallization history for 78235, its subsequent shock history, and its relationship to other lunar crustal rocks, orthopyroxene, plagioclase, glass, and whole-rock samples were prepared and analyzed for major, minor, and trace elements. It is speculated that an early fractional crystallization event producing a layer of orthopyroxene-plagioclase cumulate with varying amounts of trapped liquid took place within 20 km of the surface of the moon.

Winzer, S. R.↗

Space fabrication demonstration system

The development effort on the composite beam cap fabricator was completed within cost and close to abbreviated goals. The design and analysis of flight weight primary and secondary beam builder structures proceeded satisfactorily but remains curtailed until further funding is made available to complete the work. The induction fastening effort remains within cost and schedule constraints. Tests of the LARC prototype induction welder is continuing in an instrumented test stand comprised of a Dumore drill press (air over oil feed for variable applied loads) and a dynamometer to measure actual welding loads. Continued testing shows that the interface screening must be well impregnated with resin to ensure proper flow when bonding graphite-acrylic lap shear samples. Specimens prepared from 0.030 inch thick graphite-polyethersulfone are also available for future induction fastening evaluation.

Source record↗