Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rotation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

NGC 1866: First Spectroscopic Detection of Fast-rotating Stars in a Young LMC Cluster

High-resolution spectroscopic observations were taken of 29 extended main-sequence turnoff (eMSTO) stars in the young (∼200 Myr) Large Magellanic Cloud (LMC) cluster, NGC 1866, using the Michigan/ Magellan Fiber System and MSpec spectrograph on the Magellan -Clay 6.5 m telescope. These spectra reveal the first direct detection of rapidly rotating stars whose presence has only been inferred from photometric studies. The eMSTO stars exhibit H α emission (indicative of Be-star decretion disks), others have shallow broad H α absorption (consistent with rotation ≳150 km s{sup −1}), or deep H α core absorption signaling lower rotation velocities (≲150 km s{sup −1}). The spectra appear consistent with two populations of stars—one rapidly rotating, and the other, younger and slowly rotating.

79 ASTRONOMY AND ASTROPHYSICS↗

Integration of vestibular and head movement signals in the vestibular nuclei during whole-body rotation

Single-unit recordings were obtained from 107 horizontal semicircular canal-related central vestibular neurons in three alert squirrel monkeys during passive sinusoidal whole-body rotation (WBR) while the head was free to move in the yaw plane (2.3 Hz, 20 degrees /s). Most of the units were identified as secondary vestibular neurons by electrical stimulation of the ipsilateral vestibular nerve (61/80 tested). Both non-eye-movement (n = 52) and eye-movement-related (n = 55) units were studied. Unit responses recorded when the head was free to move were compared with responses recorded when the head was restrained from moving. WBR in the absence of a visual target evoked a compensatory vestibulocollic reflex (VCR) that effectively reduced the head velocity in space by an average of 33 +/- 14%. In 73 units, the compensatory head movements were sufficiently large to permit the effect of the VCR on vestibular signal processing to be assessed quantitatively. The VCR affected the rotational responses of different vestibular neurons in different ways. Approximately one-half of the units (34/73, 47%) had responses that decreased as head velocity decreased. However, the responses of many other units (24/73) showed little change. These cells had signals that were better correlated with trunk velocity than with head velocity. The remaining units had responses that were significantly larger (15/73, 21%) when the VCR produced a decrease in head velocity. Eye-movement-related units tended to have rotational responses that were correlated with head velocity. On the other hand, non-eye-movement units tended to have rotational responses that were better correlated with trunk velocity. We conclude that sensory vestibular signals are transformed from head-in-space coordinates to trunk-in-space coordinates on many secondary vestibular neurons in the vestibular nuclei by the addition of inputs related to head rotation on the trunk. This coordinate transformation is presumably important for controlling postural reflexes and constructing a central percept of body orientation and movement in space.

Non-NASA Center↗

Experimental Evaluation of a Residential Refrigerator with a Novel Rotating Heat Exchanger as an Evaporator

Residential refrigerator designs have improved significantly over the recent years to achieve the required federal minimum energy standard and match with consumer expectations. Designers have been able to use innovative design features and components; however, evaporator designs have lagged in performance improvement due to the need to properly manage frost and maximize the freezer interior volume. Rotating Heat Exchangers (RHX) provide an innovative solution that addresses both of these concerns. The rotation of the fins results in continuous disruption to the boundary layer, hence reducing the overall thermal resistance. Thus, for the same capacity, the heat transfer area can be greatly reduced. Furthermore, the rotation inhibits frost growth on the fins and reduces the time and frequency of defrosting. In this paper, we present an experimental evaluation of the RHX in a benchtop refrigerant loop system showing results for different operating configurations. Cooling capacity, cooling COP, and overall energy consumption are investigated. High-speed imaging is also used to capture frost growth patterns over time on the RHX fins in the presence and absence of rotation. The results show that the rotating heat exchanger evaporator is capable of meeting the 100 W capacity requirement of residential refrigerators, while offering the potential of significant reduction in defrost energy consumption.

Evaporator↗

Algorithm for Unfolding Current from Faraday Rotation Measurement

Various methods are described to translate Faraday rotation measurements into a useful representation of the dynamic current under investigation[1]. For some experiments, simply counting the “fringes” up to the turnaround point in the recorded Faraday rotation signal is sufficient in determining the peak current within some allowable fringe uncertainty. For many other experiments, a higher demand for unfolding the entire dynamic current profile is required. In such cases, investigators often rely extensively on user interaction on the Faraday rotation data by visually observing the data and making logical decisions on what appears to be turnaround points and/or inflections in the signal. After determining extrema, inflection points, and locations, a piece-wise, ΔI/Δt, representation of the current may be revealed with the proviso of having a reliable Verdet constant of the Faraday fiber or medium and time location for each occurring fringe. In this paper, a unique software program is reported which automatically decodes the Faraday rotation signal into a time-dependent current representation. System parameters such as the Faraday fiber’s Verdet constant and number of loops in the sensor are the only user-interface inputs. The central aspect of the algorithm utilizes a short-time Fourier transform (STFT) which reveals much of the Faraday rotation’s hidden detail necessary for unfolding the dynamic current measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A reevaluation of the assignment of the vibrational fundamentals and the rotational analysis of bands in the high-resolution infrared spectra of trans- and cis- 1,3,5-hexatriene

Assignments of the vibrational fundamentals of cis- and trans-1,3,5-hexatriene are reevaluated with new infrared and Raman spectra and with quantum chemical predictions of intensities and anharmonic frequencies. The rotational structure is analyzed in the high-resolution (0.0013-0.0018 cm -1) infrared spectra of three C-type bands of the trans isomer and two C-type bands of the cis isomer. The bands for the trans isomer are at 1010.96 cm-1 (v14), 900.908 cm-1 (v16), and 683.46 cm-1 (v17). Ground state (GS) rotational constants have been fitted to the combined ground state combination differences (GSCDs) for the three bands of the trans isomer. The bands for the cis isomer are at 907.70 cm-1 (v33) and 587.89 cm-1 (v35). GS rotational constants have been fitted to the combined GSCDs for the two bands of the cis isomer and compared with those obtained from microwave spectroscopy. Small inertial defects in the GSs confirm that both molecules are planar. Upper state rotational constants were fitted for all five bands.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wave-particle Interactions In Rotating Mirrors

Wave-particle interactions in E×B rotating plasmas feature an unusual effect: particles are diffused by waves in both potential energy and kinetic energy. This wave-particle interaction generalizes the alpha channeling effect, in which radio frequency waves are used to remove alpha particles collisionlessly at low energy. In rotating plasmas, the alpha particles may be removed at low energy through the loss cone, and the energy lost may be transferred to the radial electric field. This eliminates the need for electrodes in the mirror throat, which have presented serious technical issues in past rotating plasma devices. A particularly simple way to achieve this effect is to use a high azimuthal mode number perturbation on the magnetic field. Rotation can also be sustained by waves in plasmas without a kinetic energy source. This type of wave has been considered for plasma centrifuges used for isotope separation. Energy may also be transferred from the electric field to particles or waves, which may be useful for ion heating and energy generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental and theoretical investigations of rotating algae biofilm reactors (RABRs): Areal productivity, nutrient recovery, and energy efficiency

Microalgae biofilms have been demonstrated to recover nutrients from wastewater and serve as biomass feedstock for bioproducts. However, there is a need to develop a platform to quantitatively describe microalgae biofilm production, which can provide guidance and insights for improving biomass areal productivity and nutrient uptake efficiency. Here, this paper proposes a unified experimental and theoretical framework to investigate algae biofilm growth on a rotating algae biofilm reactor (RABR). Experimental laboratory setups are used to conduct controlled experiments on testing environmental and operational factors for RABRs. We propose a differential–integral equation‐based mathematical model for microalgae biofilm cultivation guided by laboratory experimental findings. The predictive mathematical model development is coordinated with laboratory experiments of biofilm areal productivity associated with ammonia and inorganic phosphorus uptake by RABRs. The unified experimental and theoretical tool is used to investigate the effects of RABR rotating velocity, duty cycle (DC), and light intensity on algae biofilm growth, areal productivity, nutrient uptake efficiency, and energy efficiency in wastewater treatment. Our framework indicates that maintaining a reasonable light intensity range improves biomass areal productivity and nutrient uptake efficiency. Our framework also indicates that faster RABR rotation benefits biomass areal productivity. However, maximizing the nutrient uptake efficiency requires a reasonably low RABR rotating speed. Energy efficiency is strongly correlated with RABR rotating speed and DC.

09 BIOMASS FUELS↗

From rotating to charged black holes and back again

The mild form of the Weak Gravity Conjecture (WGC) requires higher derivative corrections to extremal charged black holes to increase their charge-to-mass ratio. This allows decay via emission of a smaller extremal black hole. In this paper, we investigate if similar constraints hold for extremal rotating black holes. We do so by considering the leading higher derivative corrections to the four-dimensional Kerr black hole and five-dimensional Myers-Perry black hole. We use a known mapping of these rotating solutions to a four-dimensional non-rotating dyonic Kaluza-Klein black hole and impose the WGC on this charged solution. Going back again to the rotating solutions, this fixes the sign of the corrections to the rotating extremality bounds. The sign of the corrections is non-universal, depending on the black hole under consideration. We argue that this is not at odds with black hole decay, because of the presence of a superradiant instability that persists in the extremal limit. When this instability is present, the WGC is implied for the four-dimensional charged black hole.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Imaging of the Coronary Venous System: Validation of Three-Dimensional Rotational Venous Angiography Against Dual-Source Computed Tomography

Information on the anatomy of the cardiac venous system (CVS) is increasingly important for cardiac resynchronization therapy or percutaneous transvenous mitral valve annuloplasty. Three-dimensional (3D) imaging can further improve the understanding of the relationship of cardiac structures. This study was performed to validate the accuracy of rotational coronary sinus angiography (CSA) displaying the 3D anatomy of the CVS compared to ECG-gated, contrast-enhanced, cardiac dual-source computed tomography (DSCT). Five domestic pigs (60 kg) underwent DSCT using a standardized examination protocol. Using a standard C-arm for fluoroscopy, a rotational CSA was obtained and 3D-image reconstructions performed. Side branches were identified using both methods and enumerated. Vessel visibility was estimated for each side branch and great cardiac vein/anterior interventricular vein. Also, vessel diameters were measured at distinct landmarks, i.e., side branching. The amount of contrast medium was determined and the effective radiation exposure of both methods was calculated. There was no significant difference regarding the vessel diameter of the great cardiac vein/anterior interventricular vein or its side branches. Also, estimation of vessel visibility was not different between the two imaging modalities. Estimated radiation exposure and amount of contrast medium were lower for rotational CSA. In conclusion, a 3D reconstruction of rotational CSA images is possible. All parts of the CVS are well depicted, allowing a 3D overview of the CVS anatomy. On-site 3D visualization might improve decision making during cardiac interventions. In contrast to DSCT, rotational CSA does not demonstrate the anatomy of the mitral annulus or the course of the left circumflex artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Value of Rotational Venography Versus Anterior–Posterior Venography in 100 Consecutive IVC Filter Retrievals

PurposeAccurately detecting inferior vena cava (IVC) filter complications is important for safe and successful retrieval as tip-embedded filters require removal with non-standard techniques. Venography prior to IVC filter retrieval has traditionally used a single anterior–posterior (AP) projection. This study compares the utility of rotational venography to AP venography prior to IVC filter removal.Materials and MethodsThe rotational venograms from 100 consecutive IVC filter retrievals over a 35-month period were evaluated retrospectively. The AP view of the rotational venogram was examined separately from the full series by a radiologist blinded to alternative imaging and operative findings. The venograms were evaluated for tip embedding, filter fracture, filter thrombus, and IVC thrombus. Statistical analysis was performed.ResultsUsing operative findings and peri-procedural imaging as the reference standard, tip embedding occurred in 59 of the 100 filters (59 %). AP venography was used to correctly identify 31 tip-embedded filters (53 % sensitivity) with two false positives (95 % specificity) for an accuracy of 70 %. Rotational venography was used to correctly identify 58 tip-embedded filters (98 % sensitivity) with one false positive (98 % specificity) for an accuracy of 98 %. A significant difference was found in the sensitivities of the two diagnostic approaches (P < .01). Other findings of thrombus and filter fracture were not significantly different between the two groups.ConclusionRotational venograms allow for more accurate detection of tip-embedded IVC filters compared to AP views alone. As this determines the approach taken, rotational venograms are helpful if obtained prior to IVC filter retrieval.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing nitrous oxide emissions and optimizing nitrogen-use efficiency in dryland crop rotations with different nitrogen rates

Recent interests in improving agricultural production while minimizing environmental footprints emphasized the need for research on management strategies that reduce nitrous oxide (N 2 O) emissions and increase nitrogen-use efficiency (NUE) of cropping systems. This study aimed to evaluate N 2 O emissions, annualized crop grain yield, emission factor, and yield-scaled- and NUE-scaled N 2 O emissions under continuous spring wheat (Triticum aestivum L.) (CW) and spring wheat-pea (Pisum sativum L.) (WP) rotations with four N fertilization rates (0, 50, 100, and 150 kg N ha(-1)). The N 2 O fluxes peaked immediately after N fertilization, intense precipitation, and snowmelt, which accounted for 75-85% of the total annual flux. Cumulative N 2 O flux usually increased with increased N fertilization rate in all crop rotations and years. Annualized crop yield and NUE were greater in WP than CW for 0 kg N ha(-1) in all years, but the trend reversed with 100 kg N ha(-1) in 2013 and 2015. Crop yield maximized at 100 kg N ha(-1), but NUE declined linearly with increased N fertilization rate in all crop rotations and years. As N fertilization rate increased, N fertilizer-scaled N2O flux decreased, but NUE-scaled N 2 O flux increased non-linearly in all years, regardless of crop rotations. The yield-scaled N 2 O flux decreased from 0 to 50 kg N ha -1 and then increased with increased N fertilization rate. Because of non-significant difference of N 2 O fluxes between 50 and 100 kg N ha(-1), but increased crop yield, N 2 O emissions can be minimized while dryland crop yields and NUE can be optimized with 100 kg N ha -1 , regardless of crop rotations.

54 ENVIRONMENTAL SCIENCES↗

Influence of Rotation Rate on Microstructure and Comprehensive Performance of FSWed Mg Alloy

Die-casting AZ31 Mg alloys were successfully friction stir welded at a constant welding speed and different rotation rates. More uniform and fine grains were obtained at the rotation rate of 1400 rpm due to more suitable temperature for dynamic recrystallization in this welding condition. In addition, the intensity of (0001) texture in stir zone increased with the increasing rotation rate. The results of mechanical property test indicated joint with rotation rate of 1400 rpm had better tensile property, which was associated with fine grains, uniform transition in the interface between thermo-mechanically affected zone and stir zone as well as more favorable Schmidt factor for basal slip and twinning. The corrosion resistance of joints increased with the increasing rotation rate, which is significantly related to the (0001) texture with basal plane parallel to the corroded surfaces.

36 MATERIALS SCIENCE↗

Weyl type spin–orbit coupled ferromagnetic Bose–Einstein condensates under rotation

Highlights: Spinor Bose–Einstein condensates with Weyl type spin–orbit coupling and rotation are considered. Different topological patterns are obtained in the full parameter space. Effects of spin-independent and spin-dependent interactions on the ground state are also discussed. -- Abstract: We investigate the ground state of ferromagnetic Bose–Einstein condensates with Weyl type spin–orbit coupling and rotation. When the spin–orbit coupling is strong, the ground state of the system exhibits square lattice phase for the non-rotation case, while two half-skyrmion chains can occur, which is perpendicular to each other, for the rotation case. For the weak spin–orbit coupling case, half-skyrmion displays the symmetrical arrangement around Mermin–Ho vortex at the center of condensates as the rotation frequency is increased. Moreover, the effects of spin-independent and spin-dependent interactions on the ground state are also studied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polymer coatings on zirconia microspheres via rotating flow fluid dynamics

Conventional tristructural isotropic (TRISO) coatings for nuclear fuels require multi-step and expensive formation processes; any breakage of the coatings may lead to fission species release. Polymer derived ceramic (PDC) coatings can be a suitable alternative to address these issues. In this study, allylhydridopolycarbosilane (SMP-10) coatings were created on yttria stabilized zirconia (YSZ) microspheres using a Rotating Flow Fluid Dynamics (RFFD) coating method. The effects of curing temperature, rotation speed, and coating cycle/time on the coating were analyzed. Surface functionalization of YSZ microspheres with NaOH resulted in good adhesion between the polymer precursor and the YSZ kernel particles. Spectroscopy analysis revealed complete curing of SMP-10 coated YSZ at 160 °C. Rotation speed and coating time significantly affect the coating characteristics. After 3 cycles at lower rotation speed (50 rpm) for 10 min each, the coating obtained was uniform and homogeneous. In comparison, the coating showed almost 10 times less eccentricity at a high rotation speed of 300 rpm. Compared with the coatings prepared at 300 rpm condition, the coatings have higher sphericity and lower eccentricity at 50 rpm. Overall, this study provides a novel and effective route for fabricating and curing SMP-10 precursor coatings on YSZ microspheres.

Ravi, Nivetha [University of Alabama, Birmingham]↗

Roles of the {beta} subunit hinge domain in ATP synthase F{sub 1} sector: Hydrophobic network formed by introduced {beta}Phe174 inhibits subunit rotation

The ATP synthase {beta} subunit hinge domain ({beta}Phe148 {approx} {beta}Gly186, P-loop/{alpha}-helixB/loop/{beta}-sheet4, Escherichia coli residue numbering) dramatically changes in conformation upon nucleotide binding. We previously reported that F{sub 1} with the {beta}Ser174 to Phe mutation in the domain lowered the {gamma} subunit rotation speed, and thus decreased the ATPase activity [M. Nakanishi-Matsui, S. Kashiwagi, T. Ubukata, A. Iwamoto-Kihara, Y. Wada, M. Futai, Rotational catalysis of Escherichia coli ATP synthase F{sub 1} sector. Stochastic fluctuation and a key domain of the {beta} subunit, J. Biol. Chem. 282 (2007) 20698-20704.]. Homology modeling indicates that the amino acid replacement induces a hydrophobic network, in which the {beta}Met159, {beta}Ile163, and {beta}Ala167 residues of the {beta} subunit are involved together with the mutant {beta}Phe174. The network is expected to stabilize the conformation of {beta}{sub DP} (nucleotide-bound form of the {beta} subunit), resulting in increased activation energy for transition to {beta}{sub E} (empty {beta} subunit). The modeling further predicts that replacement of {beta}Met159 with Ala or Ile weakens the hydrophobic network. As expected, these two mutations experimentally suppressed the ATPase activities as well as subunit rotation of {beta}S174F. Furthermore, the rotation rate decreased with the increase of the strength in the hydrophobic network. These results indicate that the smooth conformational change of the {beta} subunit hinge domain is pertinent for the rotational catalysis.

60 APPLIED LIFE SCIENCES↗

H{sup +} and Na{sup +} are involved in flagellar rotation of the spirochete Leptospira

Leptospira is a spirochete possessing intracellular flagella. Each Leptospira flagellar filament is linked with a flagellar motor composed of a rotor and a dozen stators. For many bacterial species, it is known that the stator functions as an ion channel and that the ion flux through the stator is coupled with flagellar rotation. The coupling ion varies depending on the species; for example, H{sup +} is used in Escherichia coli, and Na{sup +} is used in Vibrio spp. to drive a polar flagellum. Although genetic and structural studies illustrated that the Leptospira flagellar motor also contains a stator, the coupling ion for flagellar rotation remains unknown. In the present study, we analyzed the motility of Leptospira under various pH values and salt concentrations. Leptospira cells displayed motility in acidic to alkaline pH. In the presence of a protonophore, the cells completely lost motility in acidic to neutral pH but displayed extremely slow movement under alkaline conditions. This result suggests that H{sup +} is a major coupling ion for flagellar rotation over a wide pH range; however, we also observed that the motility of Leptospira was significantly enhanced by the addition of Na{sup +}, though it vigorously moved even under Na{sup +}-free conditions. These results suggest that H{sup +} is preferentially used and that Na{sup +} is secondarily involved in flagellar rotation in Leptospira. The flexible ion selectivity in the flagellar system could be advantageous for Leptospira to survive in a wide range of environment. - Highlights: • This is a study on input energy for motility in the spirochete Leptospira. • Leptospira biflexa exhibited active motility in acidic to alkaline pH. • Both H{sup +} and Na{sup +} are involved in flagellar rotation in Leptospira. • H{sup +} is a primary energy source, but Na{sup +} can secondarily enhance motility.

60 APPLIED LIFE SCIENCES↗

Dosimetric Effect of Translational and Rotational Errors for Patients Undergoing Image-Guided Stereotactic Body Radiotherapy for Spinal Metastases

Purpose: To investigate the dosimetric effects of translational and rotational patient positioning errors on the treatment of spinal and paraspinal metastases using computed tomography image-guided stereotactic body radiotherapy. The results of this study provide guidance for the treatment planning process and recognition of the dosimetric consequences of daily patient treatment setup errors. Methods and Materials: The data from 20 patients treated for metastatic spinal cancer using image-guided stereotactic body radiotherapy were investigated in this study. To simulate the dosimetric effects of residual setup uncertainties, 36 additional plans (total, 756 plans) were generated for each isocenter (total, 21 isocenters) on the planning computed tomography images, which included isocenter lateral, anteroposterior, superoinferior shifts, and patient roll, yaw, and pitch rotations. Tumor volume coverage and the maximal dose to the organs at risk were compared with those of the original plan. Six daily treatments were also investigated to determine the dosimetric effect with or without the translational and rotational corrections. Results: A 2-mm error in translational patient positioning error in any direction can result in >5% tumor coverage loss and >25% maximal dose increase to the organs at risk. Rotational correction is very important for patients with multiple targets and for the setup of paraspinal patients when the isocenter is away from bony structures. Compared with the original plans, the daily treatment data indicated that translational adjustments could correct most of the setup errors to mean divergences of -1.4% for tumor volume coverage and -0.3% for the maximal dose to the organs at risk. Conclusion: For the best dosimetric results, spinal stereotactic treatments should have setup translational errors of {<=}1 mm and rotational errors of {<=}2 deg.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Translational and Rotational Errors on Complex Dose Distributions With Off-Line and On-Line Position Verification

Purpose: To investigate the influence of translational and rotational errors on prostate intensity-modulated radiotherapy (IMRT) with an integrated boost to the tumor and to evaluate the effect of the use of an on-line correction protocol. Methods and Materials: For 19 patients, who had been treated with prostate IMRT and fiducial marker-based position verification, highly inhomogeneous IMRT plans, including an integrated tumor boost, were made using varying margins (2, 4, 6, and 8 mm). The measured translational and rotational errors were used to calculate the dose using two positioning strategies: an off-line and an on-line protocol to correct the translational shifts. The estimated dose to the targets and the organs at risk was compared with the intended dose. Results: Residual deviations after off-line correction led to statistically significant, but very small, reductions in dose coverage. Even when a 2-mm margin was used, the average reduction in dose to 99% of the volume was 1.4 {+-} 1.9 Gy for the tumor, 1.5 {+-} 1.5 Gy for the prostate without seminal vesicles (boost volume), and 4.3 {+-} 4.6 Gy, including the seminal vesicles (clinical target volume). Patients with large systematic rotational errors demonstrated a substantial decrease in dose, especially for the clinical target volume. If an on-line correction protocol was used, the average mean dose and dose to 99% of the volume of the targets improved. However, the extensive dose reduction for patients with large rotational errors barely recovered with on-line correction. Conclusion: For complex prostate IMRT with an integrated tumor boost, the use of an on-line correction protocol yields little improvement without the correction of rotational errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗