Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “renewable variable generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Extended-Term Dynamic Simulations with High Penetrations of Photovoltaic Generation.

The uncontrolled intermittent availability of renewable energy sources makes integration of such devices into today's grid a challenge. Thus, it is imperative that dynamic simulation tools used to analyze power system performance are able to support systems with high amounts of photovoltaic (PV) generation. Additionally, simulation durations expanding beyond minutes into hours must be supported. This report aims to identify the path forward for dynamic simulation tools to accom- modate these needs by characterizing the properties of power systems (with high PV penetration), analyzing how these properties affect dynamic simulation software, and offering solutions for po- tential problems. We present a study of fixed time step, explicit numerical integration schemes that may be more suitable for these goals, based on identified requirements for simulating high PV penetration systems. We also present the alternative of variable time step integration. To help determine the characteristics of systems with high PV generation, we performed small signal sta- bility studies and time domain simulations of two representative systems. Along with feedback from stakeholders and vendors, we identify the current gaps in power system modeling including fast and slow dynamics and propose a new simulation framework to improve our ability to model and simulate longer-term dynamics.

14 SOLAR ENERGY↗

Demand Response in Bangalore: Implications for Electricity System Operations

Recent Greening the Grid studies for India highlight the benefits of flexible resources for integrating variable renewable energy onto India’s electricity system. India’s ambitious renewable energy targets, which are particularly focused on renewable resource states such as Karnataka, will face fewer challenges when combined with new planning and operational strategies and technologies. This report explores one such strategy - demand response - by which the system operator shifts load throughout a day to minimize system wide production costs. To explore this strategy, we added demand response resources to Karnataka’s electricity system in a production cost model of India, using load shifting potential analyzed by Lawrence Berkeley National Labs. We then investigated the impacts of increasing demand response capacity under several renewable resource scenarios. Our results show the addition of demand response enables fuel shifting from high-marginal-cost and emissions-intensive subcritical coal and diesel generation to zero-marginal-cost and emissions-free renewable generation. Accordingly, the value that demand response provides to the system increases as the renewable penetration increases. In addition to reducing production costs and emissions, demand response reduces the time that thermal generators spend at their minimum output levels, which typically represents a less efficient and costlier operational state. Agricultural load shifting provides greater value to the system than residential, commercial, or industrial loads. Agricultural demand response is more flexible than other sectors because it is not exposed to subdaily operational constraints and it can operate for more hours per day without impacting customer satisfaction. Further, the first increment of demand response that is added to a system provides the greatest value; further additions provide additional benefits but have a decreasing impact. The insights we discuss could be leveraged by system planners and operators in other jurisdictions, particularly those facing significant renewable energy penetrations, to develop their own demand response programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Supercapacitor to Provide Ancillary Services With Control Coordination

This paper proposes a dynamic frequency support scheme of a supercapacitor energy storage system (SCESS) in coordination with run-of-the-river-based pumped storage hydropower (PSH) to enhance the short-term frequency stability in a power system that has a high penetration of renewable energy. To achieve this, the proposed coordinated frequency controller (CFC) enables the SCESS and PSH plant to provide the frequency response. The CFC scheme employs a dynamic droop characteristic in parallel with an integral controller and a distribution function. The dynamic droop characteristic determines the power production for frequency regulation employing a variable gain, which varies with the total capacity of the frequency control units and magnitude of the system frequency error with time; the gain increases with the frequency error, and thereby, arresting the frequency nadir at a higher level than in the conventional droop characteristic. In addition, the distribution function dispatches the power from the dynamic droop and integral controller to the control units in proportion to their headrooms; furthermore, the distribution function considers a sudden loss of generation from an SCESS by its operational constraint during the frequency support. Thus, the proposed dynamic frequency support scheme can enhance the short-term frequency stability for a frequency event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling transmission line constraints in two-stage robust unit commitment problem

Integration of renewable energy sources and demand response poses new challenges to system operators as they increase the uncertainty of the power supply and demand. Recently, robust optimization techniques are applied to the unit commitment problem with uncertainty as an alternative to the stochastic programming approaches. However, it remains challenging to solve the robust unit commitment model with full transmission line constraints. In this paper, we propose novel acceleration techniques for solving two-stage robust unit commitment problem with consideration of full transmission line constraints. We use 1) the cutting-plane algorithm for the master problem, which dynamically includes critical transmission line constraints, and 2) column-generation methods, including the branch-and-price-and-cut algorithm and heuristic approaches, for the subproblems, which add only necessary transmission line dual variables on the fly. Furthermore, computational results for the modified IEEE 118-bus system show that the combination of the cutting-plane algorithm and the heuristic column-generation approach greatly reduces the total solution time of the two-stage robust unit commitment problem.

Heuristic algorithms↗

Chapter 2: Thermal Energy Storage for Energy Decarbonization

Thermal energy storage (TES) deployed with concentrating solar power (CSP) has shown value and capabilities in generating dispatchable power. It has attracted significant interest for potential roles in energy storage for various capacities and applications. Energy storage plays an important role in expanding renewable generation and is becoming indispensable in future carbon-free electric power. TES development and deployment provide various possibilities for electric storage and have shown advantages in capacity and flexibility to support renewable integration. In addition, renewable energy integrated with a low-cost TES system can potentially provide a reliable thermal energy supply to displace fossil fuels for broad decarbonization. Varieties of TES technologies and developments breed new areas of growth in TES materials, designs, components, and system configurations, which provide opportunities for substantial cost reduction and performance improvements to meet the technoeconomic challenges in practical applications. This chapter will describe recent progress in thermal energy storage research and development and primarily focus on sensible heat storage and its applications in supplying reliable electricity and industry process heat by integrating with variable renewable energy.

concentrating solar thermal power↗

Generating Electricity with Hydraulically Amplified Self-Healing Electrostatic (HASEL) Transducers

This study identifies hydraulically amplified self-healing electrostatic (HASEL) transducers as electricity generators, contrary to their conventional role as actuators. HASELs are soft, variable-capacitance transducers inspired by biological muscles which were developed to mimic the flexibility and functionality of natural muscle tissues. This research characterizes HASELs as generators by reversing their energy conversion mechanism—generating electricity through mechanical deformation. The study assesses the practical laboratory performance of HASELs by analytic modeling and experimental evaluation. Outcomes of the study include the following: (i) up to 2.5 mJ per cycle per 50 mm wide HASEL pouch of positive net energy generation in experimental testing—corresponding to an energy density of 2.0 mJ cm−3; (ii) a maximum theoretical energy density of 4.2 mJ cm−3; (iii) the electromechanical characteristics governing efficient conversion; and (iv) design considerations to enhance HASEL generator performance in future applications. This study broadens HASEL’s applicability and utility as a multi-functional transducer for renewable energy and general adaptive electricity generation.

13 HYDRO ENERGY↗

Statistical Characterization of Solar Photovoltaic Power Variability at Small Timescales: Preprint

Integrating large amounts of variable and uncertain solar photovoltaic power into the electricity grid is a growing concern for power system operators in a number of different regions. Power system operators typically accommodate variability, whether from load, wind, or solar, by carrying reserves that can quickly change their output to match the changes in the solar resource. At timescales in the seconds-to-minutes range, this is known as regulation reserve. Previous studies have shown that increasing the geographic diversity of solar resources can reduce the short term-variability of the power output. As the price of solar has decreased, the emergence of very large PV plants (greater than 10 MW) has become more common. These plants present an interesting case because they are large enough to exhibit some spatial smoothing by themselves. This work examines the variability of solar PV output among different arrays in a large ({approx}50 MW) PV plant in the western United States, including the correlation in power output changes between different arrays, as well as the aggregated plant output, at timescales ranging from one second to five minutes.

14 SOLAR ENERGY↗

Operational Impacts of Operating Reserve Demand Curves on Production Cost and Reliability: Preprint

The electric power industry landscape is continually evolving. As emerging technologies such as wind, solar, electric vehicles, and energy storage systems become more cost-effective and present in the system, traditional power system operating strategies will need to be reevaluated. The presence of wind and solar generation (commonly referred to as variable generation) may result in an increase in the variability and uncertainty of the net load profile. One mechanism to mitigate this is to schedule and dispatch additional operating reserves. These operating reserves aim to ensure that there is enough capacity online in the system to account for the increased variability and uncertainty occurring at finer temporal resolutions. A new operating reserve strategy, referred to as flexibility reserve, has been introduced in some regions. A similar implementation is explored in this paper, and its implications on power system operations are analyzed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Land use and turbine technology influences on wind potential in the United States

As clean energy ambitions have expanded, critically evaluating renewable energy supply has become increasingly important to the energy research community and stakeholders. This study examines the onshore wind resource potential for the conterminous United States and its sensitivity to siting constraints and turbine technology innovation. We compile localized regulatory information and use high-resolution data to present multiple siting regimes covering relatively constrained to unconstrained potentials. Our efforts reveal high sensitivity to these variables and sizable uncertainty in the overall wind energy resource potential. Specifically, we find that siting constraints may shift the total capacity available to commercial wind energy by 2.3–15.1 TW. Furthermore, our results illustrate that technology advancement could require larger setbacks from buildings and infrastructure, reducing the total available capacity potential by 20% relative to estimates using current technology, but that this reduction is largely offset by increased generation such that the net effect on generation is 1%. The observed sensitivity to and uncertainty resulting from the variables we analyze suggest there is value in continued study and development of increasingly sophisticated approaches to characterizing wind resource potential.

14 SOLAR ENERGY↗

Flexible Coal: Evolution from Baseload to Peaking Plant (Brochure)

Twenty-first century power systems, with higher penetration levels of low-carbon energy, smart grids, and other emerging technologies, will favor resources that have low marginal costs and provide system flexibility (e.g., the ability to cycle on and off to follow changes in variable renewable energy plant output). Questions remain about both the fate of coal plants in this scenario and whether they can cost-effectively continue to operate if they cycle routinely. The experience from the CGS plant demonstrates that coal plants can become flexible resources. This flexibility - namely the ability to cycle on and off and run at lower output (below 40% of capacity) - requires limited hardware modifications but extensive modifications to operational practice. Cycling does damage the plant and impact its life expectancy compared to baseload operations. Nevertheless, strategic modifications, proactive inspections and training programs, among other operational changes to accommodate cycling, can minimize the extent of damage and optimize the cost of maintenance. CGS's cycling, but not necessarily the associated price tag, is replicable. Context - namely, power market opportunities and composition of the generation fleet - will help determine for other coal plants the optimal balance between the level of cycling-related forced outages and the level of capital investment required to minimize those outages. Replicating CGS's experience elsewhere will likely require a higher acceptance of forced outages than regulators and plant operators are accustomed to; however, an increase in strategic maintenance can minimize the impact on outage rates.

01 COAL, LIGNITE, AND PEAT↗

Flexible Coal: An Example Evolution from Baseload to Peaking Plant (Presentation)

Twenty-first century power systems, with higher penetration levels of low-carbon energy, smart grids, and other emerging technologies, will favor resources that have low marginal costs and provide system flexibility (e.g., the ability to cycle on and off to follow changes in variable renewable energy plant output). Questions remain about both the fate of coal plants in this scenario and whether they can cost-effectively continue to operate if they cycle routinely. The experience from the CGS plant demonstrates that coal plants can become flexible resources. This flexibility - namely the ability to cycle on and off and run at lower output (below 40% of capacity) - requires limited hardware modifications but extensive modifications to operational practice. Cycling does damage the plant and impact its life expectancy compared to baseload operations. Nevertheless, strategic modifications, proactive inspections and training programs, among other operational changes to accommodate cycling, can minimize the extent of damage and optimize the cost of maintenance. CGS's cycling, but not necessarily the associated price tag, is replicable. Context - namely, power market opportunities and composition of the generation fleet - will help determine for other coal plants the optimal balance between the level of cycling-related forced outages and the level of capital investment required to minimize those outages. Replicating CGS's experience elsewhere will likely require a higher acceptance of forced outages than regulators and plant operators are accustomed to; however, an increase in strategic maintenance can minimize the impact on outage rates.

01 COAL, LIGNITE, AND PEAT↗

Flexible Coal: An Example Evolution from Baseload to Peaking Plant (Presentation)

Twenty-first century power systems, with higher penetration levels of low-carbon energy, smart grids, and other emerging technologies, will favor resources that have low marginal costs and provide system flexibility (e.g., the ability to cycle on and off to follow changes in variable renewable energy plant output). Questions remain about both the fate of coal plants in this scenario and whether they can cost-effectively continue to operate if they cycle routinely. The experience from the CGS plant demonstrates that coal plants can become flexible resources. This flexibility - namely the ability to cycle on and off and run at lower output (below 40% of capacity) - requires limited hardware modifications but extensive modifications to operational practice. Cycling does damage the plant and impact its life expectancy compared to baseload operations. Nevertheless, strategic modifications, proactive inspections and training programs, among other operational changes to accommodate cycling, can minimize the extent of damage and optimize the cost of maintenance. CGS's cycling, but not necessarily the associated price tag, is replicable. Context - namely, power market opportunities and composition of the generation fleet - will help determine for other coal plants the optimal balance between the level of cycling-related forced outages and the level of capital investment required to minimize those outages. Replicating CGS's experience elsewhere will likely require a higher acceptance of forced outages than regulators and plant operators are accustomed to; however, an increase in strategic maintenance can minimize the impact on outage rates.

01 COAL, LIGNITE, AND PEAT↗

Quantifying the value of hydropower in the electric grid : role of hydropower in existing markets.

The electrical power industry is facing the prospect of integrating a significant addition of variable generation technologies in the next several decades, primarily from wind and solar facilities. Overall, transmission and generation reserve levels are decreasing and power system infrastructure in general is aging. To maintain grid reliability modernization and expansion of the power system as well as more optimized use of existing resources will be required. Conventional and pumped storage hydroelectric facilities can provide an increasingly significant contribution to power system reliability by providing energy, capacity and other ancillary services. However, the potential role of hydroelectric power will be affected by another transition that the industry currently experiences - the evolution and expansion of electricity markets. This evolution to market-based acquisition of generation resources and grid management is taking place in a heterogeneous manner. Some North American regions are moving toward full-featured markets while other regions operate without formal markets. Yet other U.S. regions are partially evolved. This report examines the current structure of electric industry acquisition of energy and ancillary services in different regions organized along different structures, reports on the current role of hydroelectric facilities in various regions, and attempts to identify features of market and scheduling areas that either promote or thwart the increased role that hydroelectric power can play in the future. This report is part of a larger effort led by the Electric Power Research Institute with purpose of examining the potential for hydroelectric facilities to play a greater role in balancing the grid in an era of greater penetration of variable renewable energy technologies. Other topics that will be addressed in this larger effort include industry case studies of specific conventional and hydro-electric facilities, systemic operating constraints on hydro-electric resources, and production cost simulations aimed at quantifying the increased role of hydro.

13 HYDRO ENERGY↗

Chapter 2: Evaluating a Concentrating Solar Power Plantas an Extended-Duration Peaking Resource

We explore the ability of a concentrating solar power (CSP) plant with thermal energy storage (TES) to provide peaking capacity. We focus on future power systems, wherein net load patterns may be significantly different than they are today (e.g., due to higher renewable-energy penetrations). We examine 28 locations in the southwestern United States over an 18-year period. The hourly operation of the CSP plants are simulated to determine their potential to provide energy during an eight-hour peak-load window for each day up to 365 days per year. Our result shows that for the large majority of locations and years, CSP plants with certain configurations (i.e., in terms of solar field and TES sizes) can provide nearly 100% peak-load capacity. We examine also the amount of supplemental energy (e.g.,by using natural gas as a supplemental thermal-energy source) that would be required to ensure that a CSP plant could serve the eight highest-load hours of every day of the year. We find that in most cases, a CSP plant supplemented with natural gas would require less than 5% of the fuel that is used by a natural-gas fired power plant providing the same level of reliable capacity. A series of sensitivity analyses show that these results are robust to the number of peak-load hours and days that are considered and the configuration of the CSP plant.

capacity value↗

Optimizing Process Conditions during Catalytic Fast Pyrolysis of Pine with Pt/TiO 2 —Improving the Viability of a Multiple-Fixed-Bed Configuration

Catalytic fast pyrolysis (CFP) has been identified as a promising pathway for the production of renewable fuels and co-products. However, continued technology development is needed to increase process efficiency and reduce process costs. This report builds upon previous research in which a bifunctional metal–acid Pt/TiO 2 catalyst was utilized in a fixed-bed reactor operated with co-fed H 2 to improve product yield and reduce coke generation compared to conventional CFP methods. Here, we report further process optimization, in which we achieved similar CFP oil carbon efficiency (>35%) and CFP oil oxygen content (<20 wt %) to our previous report while reducing catalyst and equipment costs by increasing time-on-stream between regenerations by 40–95% and decreasing required regeneration time by more than a factor of 2. These process improvements were achieved by conducting parameter sweeps to determine optimum conditions for CFP and regeneration with key variables including pyrolysis temperature, catalytic upgrading temperature, hydrogen partial pressure, and regeneration oxygen concentration. Coupled with comprehensive oil analyses, these data provide foundational insight into the deoxygenation and coking chemistries for CFP under realistic process conditions while also advancing the technology through applied engineering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Models to Provide Predicted Ranges for Building-Human Interfaces: Preprint

Most building energy consumption dashboards provide only a snapshot of building performance; whereas some provide more detailed historic data with which to compare current usage. This paper will discuss the Building Agent(tm) platform, which has been developed and deployed in a campus setting at the National Renewable Energy Laboratory as part of an effort to maintain the aggressive energyperformance achieved in newly constructed office buildings and laboratories. The Building Agent(tm) provides aggregated and coherent access to building data, including electric energy, thermal energy, temperatures, humidity, and lighting levels, and occupant feedback, which are displayed in various manners for visitors, building occupants, facility managers, and researchers. This paper focuseson the development of visualizations for facility managers, or an energy performance assurance role, where metered data are used to generate models that provide live predicted ranges of building performance by end use. These predicted ranges provide simple, visual context for displayed performance data without requiring users to also assess historical information or trends. Several energymodelling techniques were explored including static lookup-based performance targets, reduced-order models derived from historical data using main effect variables such as solar radiance for lighting performance, and integrated energy models using a whole-building energy simulation program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Storage Opportunities and Capabilities in a Type 3 Wind Turbine Generator

Wind power plants and other renewable power plants with power electronic interfaces are capable of delivering frequency response (both governor and/or inertial response) to the grid by a control action; thus, the reduction of available online inertia as conventional power plants are retired can be compensated by designing renewable power plant controls to include frequency response. The source of energy to be delivered as inertial response is determined by the type of generation and control strategy chosen. The cost of energy storage is expected to drop over time, and global research activities on energy storage are very active, funded both by the private industry and governments. Different industry sectors (e.g., transportation, energy) are the major drivers of the recent storage research and development. This work investigates the opportunities and capabilities of deploying energy storage in renewable power plants. In particular, we focus on wind power plants with doubly-fed induction generators, or Type 3 wind turbine generator (WTGs). We find that the total output power of a system with Type 3 WTGs with energy storage can deliver a power boost during inertial response that is up to 45% higher than one without energy storage without affecting the torque limit, thus enabling an effective delivery of ancillary services to the grid.

17 WIND ENERGY↗

Renewable-battery hybrid power plants in congested electricity markets: Implications for plant configuration

Examining coupled renewable-battery power plants (“hybrids”) in congested areas provides insights into a future of increased wind and solar penetration. Our study focuses on two types of congested regions, Variable Renewable Energy (VRE)-rich Areas and Load Centers, and explores likely plant configuration choices for developers and transmission network planners. Here, this paper examines how hybrid value, comprising energy and capacity value, varies by plant configuration and congested region type considering factors such as storage duration, battery degradation, and ability to charge from the grid. We select plant locations from across the seven main U.S. independent system operators (ISOs). Hybrid value for each configuration is computed based on profit-maximizing plant operation given perfect foresight, according to observed wholesale power market real time prices from 2018 to 2021. In VRE-rich Areas, the median increase in energy value from extending storage duration from one to 4h is 29.4% for solar and 26.8% for wind, assuming low battery degradation costs and storage sized to 100% of the plant's nameplate generation capacity. Increasing storage duration beyond 4h does not substantially increase its value from energy markets, even in VRE-rich Areas. We find that solar hybrids reach a 90% capacity credit with 4h of storage, while wind hybrids require 8h of storage, based on the capacity factor of each hybrid during the top 100 net load hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗