Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements

Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg∙m -3 to 180 kg∙m -3 , and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: λ(ρ, T) = α 0 + α 1 ρ +α 2 T + α 3 T 3 +α 4 e - ($\frac{T-a_{5}}{a_{6}}$) 2 = where λ(ρ,T) is the predicted thermal conductivity (W∙m -1 ∙K -1 ), ρ is the bulk density (kg∙m -3 ), T is the mean temperature (K) and $a_i$ (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. λ(ρ, T) = α 0 + α 1 ρ +α 2 T One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs.

regression analysis↗

The Celestial Reference Frame at X/Ka-band (8.4/32 GHz)

A celestial reference frame at X/Ka-band (8.4/32 GHz) has been constructed using fifty-one 24-hour sessions with the Deep Space Network. We report on observations which have detected 436 sources covering the full 24 hours of right ascension and declinations down to -45 deg. Comparison of this X/Ka-band frame to the S/X-band (2.3/8.4 GHz) ICRF2 shows wRMS agreement of 200 micro-arcsec in a cos delta and 290 micro-arcsec in delta. There is evidence for zonal errors at the 100 micro-arcsec level. Known errors include limited SNR, lack of phase calibration, troposphere mismodelling, and limited southern geometry. The motivations for extending the ICRF to frequencies above 8 GHz are to access more compact source morphology for improved frame stability, to provide calibrators for phase referencing, and to support spacecraft navigation at Ka-band.

reference systems catalog↗

Use of Reference Frames for Interplanetary Navigation at JPL

Navigation of interplanetary spacecraft is typically based on range, Doppler, and differential interferometric measurements made by ground-based telescopes. Acquisition and interpretation of these observations requires accurate knowledge of the terrestrial reference frame and its orientation with respect to the celestial frame. Work is underway at JPL to reprocess historical VLBI and GPS data to improve realizations of the terrestrial and celestial frames. Improvements include minimal constraint alignment, improved tropospheric modeling, better orbit determination, and corrections for antenna phase center patterns.

International Celestial Reference Frame (ICRF)↗

The Celestial Reference Frame at X/Ka-band (8.4/32 GHz)

A celestial reference frame at X/Kaband (8.4/32 GHz) has been constructed using fiftyone 24-hour sessions with the Deep Space Network. We report on observations which have detected 436 sources covering the full 24 hours of right ascension and declinations down to -45 deg. Comparison of this X/Ka-band frame to the S/X-band (2.3/8.4 GHz) ICRF2 shows wRMS agreement of 200 micro-arcsec ( mu as) in alpha cos delta and 290 mu as in delta. There is evidence for zonal errors at the 100 mu as level. Known errors include limited SNR, lack of phase calibration, troposphere mismodelling, and limited southern geometry. The motivations for extending the ICRF to frequencies above 8 GHz are to access more compact source morphology for improved frame stability, to provide calibrators for phase referencing, and to support spacecraft navigation at Ka-band.

interferometry↗

Jupiter Global Reference Atmospheric Model (Jupiter-GRAM): User Guide

This Technical Memorandum (TM) presents the Jupiter Global Reference Atmospheric Model (Jupiter-GRAM) and the updated features of the GRAMs. Jupiter-GRAM is an engineering-oriented atmospheric model that estimates mean values of atmospheric properties for Jupiter. This TM summarizes the atmospheric data model in Jupiter-GRAM and provides a guide for the user to obtain, set up, and run the code in various configurations. Additional details regarding the Jupiter-GRAM input and output files and how to interpret Jupiter-GRAM results are also provided.

atmospheric models↗

Earth Global Reference Atmospheric Model (Earth-GRAM): User Guide

This Technical Memorandum (TM) presents the Earth Global Reference Atmospheric Model (Earth-GRAM) and the updated features of the GRAMs. Earth-GRAM is an engineering-oriented atmospheric model that estimates mean values and statistical variations of atmospheric properties for Earth. This TM summarizes the atmospheric data model in Earth-GRAM and provides a guide for the user to obtain, set up, and run the code in various configurations. Additional details regarding the Earth-GRAM input and output files and how to interpret Earth-GRAM results are also provided.

Atmospheric Models↗

Venus Global Reference Atmospheric Model (Venus-GRAM): User Guide

This Technical Memorandum (TM) presents the Venus Global Reference Atmospheric Model (Venus-GRAM) and the updated features of the GRAMs. Venus-GRAM is an engineering-oriented atmospheric model that estimates mean values and statistical variations of atmospheric properties for Venus. This TM summarizes the atmospheric data model in Venus-GRAM and provides a guide for the user to obtain, set up, and run the code in various configurations. Additional details regarding the Venus-GRAM input and output files and how to interpret Venus-GRAM results are also provided.

atmospheric models↗

Mars Global Reference Atmospheric Model (Mars-GRAM): User Guide

This Technical Memorandum (TM) presents the Mars Global Reference Atmospheric Model (Mars-GRAM) and the updated features of the GRAMs. Mars-GRAM is an engineering-oriented atmospheric model that estimates mean values and statistical variations of atmospheric properties for Mars. This TM summarizes the atmospheric data model in Mars-GRAM and provides a guide for the user to obtain, set up, and run the code in various configurations. Additional details regarding the Mars-GRAM input and output files and how to interpret Mars-GRAM results are also provided.

atmospheric models↗

Mars Global Reference Atmospheric Model (Mars-GRAM) 2024: User Guide

This Technical Memorandum (TM) presents the Mars Global Reference Atmospheric Model (Mars-GRAM) 2024 and its updated features. Mars-GRAM is an engineering-oriented atmospheric model that estimates mean values and statistical variations of atmospheric properties for Mars. This TM summarizes the atmospheric data model in Mars-GRAM and provides a guide for the user to obtain, set up, and run the code in various configurations. Additional details regarding the Mars-GRAM input and output files and how to interpret Mars-GRAM results are also provided.

atmospheric density↗

Isotopic exchange on solid-phase micro extraction fiber in sediment under stagnant conditions: Implications for field application of performance reference compound calibration

An overlooked issue for field application of in situ performance reference compound (PRC) calibration methods is the validity of the assumption that both the sorption of a target compound and desorption of its corresponding PRC follow the first-order kinetics with the same rate constants under stagnant conditions. In the present study, disposable polydimethylsiloxane fibers of 2 sizes (7 and 35 µm) impregnated with 8 13 C-labeled or deuterated PRCs were statically deployed into different marine sediments, from which the kinetics for sorption of the target compounds and desorption of the PRCs were characterized. Nonsymmetrical profiles were observed for exchange of the target analytes and their corresponding PRCs in sediment under stagnant conditions. Further, the hysteretic desorption of PRCs in the kinetic regime may be ascribed to the low chemical potential between the fiber and sediment porewater, which reflects the inability of water molecules to rapidly diffuse through sediment to solvate the PRCs in the aqueous layer around the fiber surface. A moderate correlation (r = 0.77 and r = 0.57, p < 0.05 for both regressions) between the PRC-calibrated equilibrium concentrations of 1,1-dichloro-2,2-bis-(chlorophenyl) ethylene (p,p'-DDE) and polychlorinated biphenyl (PCB)-153 and the lipid normalized levels in worms (Neanthes arenaceodentata) was obtained in co-exposure tests under simulating field conditions, probably resulting from slightly overestimated bioavailability because of the hysteretic desorption of PRCs and toxic effects. Environ Toxicol Chem 2016;35:1978–1985. © 2015 SETAC

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volumetric Density-Equalizing Reference Map with Applications

The density-equalizing map, a technique developed for cartogram creation, has been widely applied to data visualization but only for 2D applications. Here, we propose a novel method called the volumetric density-equalizing reference map (VDERM) for computing density-equalizing map for volumetric domains. Given a prescribed density distribution in a volumetric domain in $\mathbb{R}^3$, the proposed method continuously deforms the domain, with different volume elements enlarged or shrunk according to the density distribution. With the aid of the proposed method, medical and sociological data can be visualized via deformations of 3D objects. The method can also be applied to adaptive remeshing and shape modeling. Furthermore, by exploiting the time-dependent nature of the proposed method, applications to shape morphing can be easily achieved. Experimental results are presented to demonstrate the effectiveness of the proposed method.

97 MATHEMATICS AND COMPUTING↗

Block Design with Common Reference Samples Enables Robust Large-Scale Label-Free Quantitative Proteome Profiling

Label-free quantitative proteomics has become an increasingly popular tool for profiling global protein abundances. However, one major weakness is the potential performance drift of the LC-MS platform over time, which in turn limits its utility for analyzing large-scale sample sets. To address this, in this work we introduce an experimental and data analysis scheme based on a block-design with common controls within each block for enabling LC-MS-based large-scale label-free quantification. In this scheme, a large number of samples (e.g., >100 samples) are analyzed in smaller, and more manageable blocks, minimizing instrument drift and variability within a block. Furthermore, each designated block also contains common controls (or reference) samples for normalization within and across blocks. We demonstrated the effectiveness of this method by profiling the proteome response of human macrophage THP-1 cells to 11 engineered nanomaterials (ENMs) at two different doses. A total of 116 samples were analyzed in six blocks, yielding an average coverage of 4500 proteins per sample. The data revealed consistent quantification of proteins across all six blocks, as shown by highly stable quantification of house-keeping proteins in all samples and high levels of quantification correlation among samples from different blocks. The data also demonstrated that label-free quantification is robust and accurate enough to quantify even very subtle abundance changes as well as large fold-changes without potential ratio compression as often encountered with isobaric labeling. Our streamlined workflow is easy to implement and can be readily adapted to other large cohort studies for reproducible label-free proteome quantification.

59 BASIC BIOLOGICAL SCIENCES↗

Cited Reference Analysis in a National Laboratory to Assess Journal Usage

Librarians at a large, federally funded, multidisciplinary research organization sought to assess the value provided by the library’s collections. One method for capturing this value includes determining how well their library’s collections meet researcher needs, as expressed by the materials those researchers choose to cite in the production of new scholarly communications. A cited reference analysis was performed on the publications originating from the institution to provide the necessary data for the assessment, as well as to aid in the creation of a core list of journals which will inform future collection development efforts. Overall, this paper fills a gap in the library and information science literature by addressing the citation behaviors of researchers at a large multidisciplinary government research facility, a setting that has not been examined previously.

99 GENERAL AND MISCELLANEOUS↗

Uncertainty evaluation in reference material characterization by double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS)

Double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is one of the most important measurement methods in the establishment of measurement standards for inorganic analysis. However, there is still no good consensus on approaches for uncertainty evaluation in double ID-ICP-MS. Particularly, approaches to treating the instrumental isotopic fractionation (IIF) phenomenon and correlation between uncertainty sources are diverse and often unclear in the literature. Here, an approach for uncertainty evaluation in double ID-ICP-MS measurements is described. Using three certified reference materials (CRMs), it is shown that the IIF effects cancel out and should not be included in the uncertainty budget. Further, a consistent way of considering correlated sources of uncertainty to prevent double counting of uncertainties is described in detail along with an example of measuring the mass fraction of magnesium in an oyster powder CRM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of loads from HAWC2 and OpenFAST for the IEA Wind 15 MW Reference Wind Turbine

Reference wind turbines (RWTs) that reflect the state-of-the-art of current wind energy technology are necessary in order to properly evaluate innovative methods in wind turbine design and evaluation. The International Energy Agency (IEA) Wind Technology Collaboration Platform (TCP) Task 37 has recently developed a new RWT geared towards offshore floating-foundation applications: the IEA Wind 15 MW. The model has been implemented in two aeroelastic codes, OpenFAST and HAWC2, based on an underlying common ontology. However, these toolchains result in slightly different structural parameters, and the two codes utilise different structural models. Thus, to increase the utility of the model, it is necessary to compare the aeroelastic responses. This paper compares aeroelastic loads calculated using different fidelities of the blade model in OpenFAST (ElastoDyn and BeamDyn) and HAWC2 (prismatic Timoshenko without torsion and Timoshenko with fully populated stiffness matrix), where both codes use the DTU Basic controller and the same turbulence boxes to reduce discrepancies. The aeroelastic responses to steady wind, step wind and turbulent wind (per IEC 61400-1 wind class IB) are considered. The results indicate a generally good agreement between the loads dominated by aerodynamic thrust and force, especially for the no-torsion blade models. Discrepancies were observed in other load channels, partially due to differences in the asymmetric loading of the rotor and partially due to differing closed-loop dynamics, and they will be the subject of future investigations.

17 WIND ENERGY↗

Investigation of Thulium and Other Rare Earth Element Mass Fractions in NIST SRM 1632a Bituminous Coal Reference Material by Quadrupole ICP-MS

Inductively coupled plasma-mass spectrometry after lithium metaborate fusion and digestion was used to measure the rare earth element (REE) mass fractions of several reference materials including NIST SRM 1632a, a historical bituminous Pennsylvania seam coal. While most of the REE mass fractions measured in this study were consistent with the published consensus data, the measured mass fraction of thulium for NIST SRM 1632a was consistently lower compared with the published data. Chondrite normalisation of the published consensus data for NIST SRM 1632a produced a positive thulium anomaly (Tm = 1.78), which is inconsistent with a terrestrial source of sediment. The Normalisation of REE mass fractions collected in this study produced no significant Tm anomaly (Tm = 0.93), which agrees with the sedimentary depositional environment of coal. Therefore, a revised mass fraction of 0.16 mg kg -1 Tm in NIST SRM 1632a is recommended.

58 GEOSCIENCES↗

Ni/NiO Reference Electrode Potential Measurements in Molten CaCl 2 –CaO

A direct oxide reduction (DOR) process is used to reduce PuO 2 to Pu metal via Ca metal. Molten CaCl 2 is commonly used as the electrolyte for this reaction. As the DOR reaction proceeds, CaO accumulates in the salt and must be measured in real-time to know when the reaction has gone to completion. Open circuit potential (OCP) was measured in this report between a reference electrode consisting of Ni/NiO contained in a MgO tube and a tungsten working electrode. Two methods of CaO additions were performed over several experiments, and both methods correlated to a 0.11 to 0.23 V decrease in OCP up to 14.4 wt% CaO. CaO concentrations were separately measured via sampling and acid-base titration. A plot of OCP versus concentration of CaO fits the Nernst equation with the CaO powder additions up to 5.2 wt% and also at the higher end of the CaO pellet concentration range. While the MgO tubes were observed to be structurally stable in the molten salt, scanning electron microscopy and energy dispersive X-ray spectroscopy showed that Mg in the tubes had been partially replaced with Ca.

36 MATERIALS SCIENCE↗

Mitigating Electrochemical Impedance Spectroscopy Artifacts in PEMWE Reference Electrode Measurements

This study investigates strategies to improve the quality of electrochemical impedance spectroscopy (EIS) measurements using reference electrodes (RE) in proton exchange membrane water electrolyzers (PEMWE). We demonstrate that adding a low impedance wire in parallel to the RE significantly enhances signal accuracy, especially at high frequencies. Additionally, we identify electrical pad heaters as a source of measurement noise. EIS measurements fulfilling Kramers–Kronig validity criteria were only achieved in their absence. These insights advance the diagnostic capabilities of REs in water electrolyzers and support more reliable, spatially resolved analysis of electrochemical losses within the cell.

08 HYDROGEN↗