Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Plasma tomographic reconstruction from tangentially viewing camera with background subtraction

Light reflections are one of the main and often underestimated issues of plasma emissivity reconstruction in visible light spectral range. Metallic and other specular components of tokamak generate systematic errors in the optical measurements that could lead to wrong interpretation of data. Our analysis is performed at data from the tokamak COMPASS. It is a D-shaped tokamak with specular metallic vessel and possibility of the H-mode plasma. Data from fast visible light camera were used for tomographic reconstruction with background reflections subtraction to study plasma boundary. In this article, we show that despite highly specular tokamak wall, it is possible to obtain a realistic reconstruction. The developed algorithm shows robust results despite of systematic errors in the optical measurements and calibration. The motivation is to obtain an independent estimate of the plasma boundary shape.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron source reconstruction from pinhole imaging at National Ignition Facility

The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the ignition stage of inertial confinement fusion (ICF) implosions at NIF. Since the neutron source is small (∼100 μm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-μm resolution are 20-cm long, single-sided tapers in gold. These apertures, which have triangular cross sections, produce distortions in the image, and the extended nature of the pinhole results in a non-stationary or spatially varying point spread function across the pinhole field of view. In this work, we have used iterative Maximum Likelihood techniques to remove the non-stationary distortions introduced by the aperture to reconstruct the underlying neutron source distributions. We present the detailed algorithms used for these reconstructions, the stopping criteria used and reconstructed sources from data collected at NIF with a discussion of the neutron imaging performance in light of other diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

Modeling and characterizing anisotropic inclusion orientation in heterogeneous material via directional cluster functions and stochastic microstructure reconstruction

We present a framework to model and characterize the microstructure of heterogeneous materials with anisotropic inclusions of secondary phases based on the directional correlation functions of the inclusions. Specifically, we have devised an efficient method to incorporate both directional two-point correlation functions S{sub 2} and directional two-point cluster functions C{sub 2} that contain non-trivial topological connectedness information into the simulated annealing microstructure reconstruction procedure. Our framework is applied to model an anisotropic aluminum alloy and the accuracy of the reconstructed structural models is assessed by quantitative comparison with the actual microstructure obtained via x-ray tomography. We show that incorporation of directional clustering information via C{sub 2} significantly improves the accuracy of the reconstruction. In addition, a set of analytical “basis” correlation functions are introduced to approximate the actual S{sub 2} and C{sub 2} of the material. With the proper choice of basis functions, the anisotropic microstructure can be represented by a handful of parameters including the effective linear sizes of the iron-rich and silicon-rich inclusions along three orthogonal directions. This provides a general and efficient means for heterogeneous material modeling that enables one to significantly reduce the data set required to characterize the anisotropic microstructure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A novel electron density reconstruction method for asymmetrical toroidal plasmas

A novel reconstruction method is developed for acquiring the electron density profile from multi-channel interferometric measurements of strongly asymmetrical toroidal plasmas. It is based on a regularization technique, and a generalized cross-validation function is used to optimize the regularization parameter with the aid of singular value decomposition. The feasibility of method could be testified by simulated measurements based on a magnetic configuration of the flexible helical-axis heliotron device, Heliotron J, which has an asymmetrical poloidal cross section. And the successful reconstruction makes possible to construct a multi-channel Far-infrared laser interferometry on this device. The advantages of this method are demonstrated by comparison with a conventional method. The factors which may affect the accuracy of the results are investigated, and an error analysis is carried out. Based on the obtained results, the proposed method is highly promising for accurately reconstructing the electron density in the asymmetrical toroidal plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction 3-dimensional image from 2-dimensional image of status optical coherence tomography (OCT) for analysis of changes in retinal thickness

Optical Coherence Tomography is often used in medical image acquisition to diagnose that change due easy to use and low price. Unfortunately, this type of examination produces a two-dimensional retinal image of the point of acquisition. Therefore, this study developed a method that combines and reconstruct 2-dimensional retinal images into three-dimensional images to display volumetric macular accurately. The system is built with three main stages: data acquisition, data extraction and 3-dimensional reconstruction. At data acquisition step, Optical Coherence Tomography produced six *.jpg images of each patient were further extracted with MATLAB 2010a software into six one-dimensional arrays. The six arrays are combined into a 3-dimensional matrix using a kriging interpolation method with SURFER9 resulting 3-dimensional graphics of macula. Finally, system provides three-dimensional color graphs based on the data distribution normal macula. The reconstruction system which has been designed produces three-dimensional images with size of 481 × 481 × h (retinal thickness) pixels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface reconstructions in molecular beam epitaxy of SrTiO{sub 3}

We show that reflection high-energy electron diffraction (RHEED) can be used as a highly sensitive tool to track surface and resulting film stoichiometry in adsorption-limited molecular beam epitaxy of (001) SrTiO{sub 3} thin films. Even under growth conditions that yield films with a lattice parameter that is identical to that of stoichiometric bulk crystals within the detection limit of high-resolution x-ray diffraction (XRD), changes in surface reconstruction occur from (1 × 1) to (2 × 1) to c(4 × 4) as the equivalent beam pressure of the Ti metalorganic source is increased. These surface reconstructions are correlated with a shift from mixed SrO/TiO{sub 2} termination to pure TiO{sub 2} termination. The crossover to TiO{sub 2} surface termination is also apparent in a phase shift in RHEED oscillations observed at the beginning of growth. Comparison with prior results for carrier mobilities of doped films shows that the best films are grown under conditions of a TiO{sub 2}-saturated surface [c(4 × 4) reconstruction] within the XRD growth window.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An improved phase shift reconstruction algorithm of fringe scanning technique for X-ray microscopy

The X-ray phase imaging method has been applied to observe soft biological tissues, and it is possible to image the soft tissues by using the benefit of the so-called “Talbot effect” by an X-ray grating. One type of the X-ray phase imaging method was reported by combining an X-ray imaging microscope equipped by a Fresnel zone plate with a phase grating. Using the fringe scanning technique, a high-precision phase shift image could be obtained by displacing the grating step by step and measuring dozens of sample images. The number of the images was selected to reduce the error caused by the non-sinusoidal component of the Talbot self-image at the imaging plane. A larger number suppressed the error more but increased radiation exposure and required higher mechanical stability of equipment. In this paper, we analyze the approximation error of fringe scanning technique for the X-ray microscopy which uses just one grating and proposes an improved algorithm. We compute the approximation error by iteration and substitute that into the process of reconstruction of phase shift. This procedure will suppress the error even with few sample images. The results of simulation experiments show that the precision of phase shift image reconstructed by the proposed algorithm with 4 sample images is almost the same as that reconstructed by the conventional algorithm with 40 sample images. We also have succeeded in the experiment with real data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Symmetry-dependent interfacial reconstruction to compensate polar discontinuity at perovskite oxide interfaces (LaAlO{sub 3}/SrTiO{sub 3} and LaAlO{sub 3}/CaTiO{sub 3})

We report the crystal symmetry-dependency of the interfacial reconstruction to relieve the polar discontinuity at the complex oxide heterointerfaces. We chose LaAlO{sub 3}/SrTiO{sub 3} and LaAlO{sub 3}/CaTiO{sub 3} interfaces as model systems, where the neutral TiO{sub 2} and the positive LaO{sup +} layers form the polar discontinuity at the interface with TiO{sub 2}-terminated (001) cubic SrTiO{sub 3} and orthorhombic CaTiO{sub 3}. Using scanning transmission electron microscopy, we observed that the interlayer distance abnormally increased at the interface. We performed the first-principles calculations to understand the detailed atomic displacement at the interfaces having no oxygen vacancy and intermixing. Our results show that cations were reconstructed in different ways depending on the crystal symmetry through the octahedral tilts and atomic displacements to compensate the polar discontinuity at the interfaces. Our results imply that the interfacial reconstructions have to be considered along with the ionic compensation (intermixing) and electronic compensation (two dimensional electron gas) to fully understand the interfacial phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Class of backpropagation techniques for limited-angle reconstruction in microwave tomography

Filtered backpropagation (FBPP) is a well-known technique used in Diffraction Tomography (DT). For accurate reconstruction using FBPP, full 360° angular coverage is necessary. However, it has been shown that using some inherent redundancies in the projection data in a tomographic setup, accurate reconstruction is still possible with 270° coverage which is called the minimal-scan angle range. This can be done by applying weighing functions (or filters) on projection data of the object to eliminate the redundancies and accurately reconstruct the image from 270° coverage. This paper demonstrates procedures to generate many general classes of these weighing filters. These are all equivalent at 270° coverage but vary in performance at lower angular coverages and in presence of noise. This paper does a comparative analysis of different filters when angular coverage is lower than minimal-scan angle of 270°. Simulation studies have been done to find optimum weight filters for sub-minimal angular coverage (<270°)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimized molecular reconstruction procedure combining hybrid reverse Monte Carlo and molecular dynamics

We report an efficient atom-scale reconstruction method that consists of combining the Hybrid Reverse Monte Carlo algorithm (HRMC) with Molecular Dynamics (MD) in the framework of a simulated annealing technique. In the spirit of the experimentally constrained molecular relaxation technique [Biswas et al., Phys. Rev. B 69, 195207 (2004)], this modified procedure offers a refined strategy in the field of reconstruction techniques, with special interest for heterogeneous and disordered solids such as amorphous porous materials. While the HRMC method generates physical structures, thanks to the use of energy penalties, the combination with MD makes the method at least one order of magnitude faster than HRMC simulations to obtain structures of similar quality. Furthermore, in order to ensure the transferability of this technique, we provide rational arguments to select the various input parameters such as the relative weight ω of the energy penalty with respect to the structure optimization. By applying the method to disordered porous carbons, we show that adsorption properties provide data to test the global texture of the reconstructed sample but are only weakly sensitive to the presence of defects. In contrast, the vibrational properties such as the phonon density of states are found to be very sensitive to the local structure of the sample.

36 MATERIALS SCIENCE↗

Forward problem solution as the operator of filtered and back projection matrix to reconstruct the various method of data collection and the object element model in electrical impedance tomography

Back projection reconstruction has been implemented to get the dynamical image in electrical impedance tomography. However the implementation is still limited in method of adjacent data collection and circular object element model. The study aims to develop the methods of back projection as reconstruction method that has the high speed, accuracy, and flexibility, which can be used for various methods of data collection and model of the object element. The proposed method uses the forward problem solution as the operator of filtered and back projection matrix. This is done through a simulation study on several methods of data collection and various models of the object element. The results indicate that the developed method is capable of producing images, fastly and accurately for reconstruction of the various methods of data collection and models of the object element.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of finite spatial coherence on ptychographic reconstruction

X-ray ptychography is an ultrahigh-resolution scanning coherent diffractive imaging technique, allowing quantitative measurements of extended samples and a simultaneous reconstruction of the illuminating wavefront. Recent development of the mixed-state reconstruction algorithm has triggered a certain interest in utilizing partially coherent X-ray sources for ptychography. Here, we study how finite spatial coherence influences the reconstructed image of a test structure. Our work shows that use of a highly coherent illumination provides images with better spatial resolution and fewer artefacts than the approach with partial coherence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstruction of chaotic saddles by classification of unstable periodic orbits: Kuramoto-Sivashinsky equation

The unstable periodic orbits (UPOs) embedded in a chaotic attractor after an attractor merging crisis (MC) are classified into three subsets, and employed to reconstruct chaotic saddles in the Kuramoto-Sivashinsky equation. It is shown that in the post-MC regime, the two chaotic saddles evolved from the two coexisting chaotic attractors before crisis can be reconstructed from the UPOs embedded in the pre-MC chaotic attractors. The reconstruction also involves the detection of the mediating UPO responsible for the crisis, and the UPOs created after crisis that fill the gap regions of the chaotic saddles. We show that the gap UPOs originate from saddle-node, period-doubling, and pitchfork bifurcations inside the periodic windows in the post-MC chaotic region of the bifurcation diagram. The chaotic attractor in the post-MC regime is found to be the closure of gap UPOs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Micro-stress dominant displacive reconstructive transition in lithium aluminate

It is supposed that diffusive reconstructive transitions usually take place under hydrostatic pressure or low stresses, and displacive reconstructive phase transitions easily occur at nonhydrostatic pressure. Here, by in-situ high pressure synchrotron X-ray diffraction and single-crystal Raman scattering studies on lithium aluminate at room temperature, we show that the reconstructive transition mechanism is dependent on the internal microscopic stresses rather than the macroscopic stresses. In this case, even hydrostatic pressure can favor the displacive transition if the compressibility of crystal is anisotropic. During hydrostatic compression, γ-LiAlO{sub 2} transforms to δ-LiAlO{sub 2} at about 4 GPa, which is much lower than that in previous nonhydrostatic experiments (above 9 GPa). In the region where both phases coexist, there are enormous microscopic stresses stemming from the lattice mismatch, suggesting that this transition is displacive. Furthermore, the atomic picture is drawn with the help of the shear Raman modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using spherical harmonic decomposition

Neutron, gamma-ray, and x-ray imaging are important diagnostic tools at the National Ignition Facility (NIF) for measuring the two-dimensional (2D) size and shape of the neutron producing region, for probing the remaining ablator and measuring the extent of the DT plasmas during the stagnation phase of Inertial Confinement Fusion implosions. Due to the difficulty and expense of building these imagers, at most only a few two-dimensional projections images will be available to reconstruct the three-dimensional (3D) sources. In this work, we present a technique that has been developed for the 3D reconstruction of neutron, gamma-ray, and x-ray sources from a minimal number of 2D projections using spherical harmonics decomposition. We present the detailed algorithms used for this characterization and the results of reconstructed sources from experimental neutron and x-ray data collected at OMEGA and NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstruction-stabilized epitaxy of LaCoO 3 /SrTiO 3 (111) heterostructures by pulsed laser deposition

Unlike widely explored complex oxide heterostructures grown along [001], the study of [111]-oriented heterointerfaces is very limited thus far. One of the main challenges is to overcome the polar discontinuity that hinders the epitaxy of atomically sharp interfaces. Here, by taking LaCoO 3 /SrTiO 3 (111) as a prototype, we show that the reconstruction, which effectively compensates the surface polarity, can stabilize the epitaxy of the heterostructure with polar discontinuity. A reconstructed substrate surface is prepared, while the growth is controlled to form reconstruction on the film surface. To suppress the chemical diffusion across the interface, the growth is interrupted between each unit cell layer to allow the lattice relaxation at a lowered temperature. In this way, high quality two-dimensional growth is realized and the heterointerfaces exhibit sharpness at the atomic scale. As a result, our work provides a path to precisely control the growth of complex oxide heterostructures along polar orientations that exhibit emergent quantum phenomena.

36 MATERIALS SCIENCE↗

Effect of reflections on 2D tomographic reconstructions of filtered cameras and on interpreting spectroscopic measurements in the JET ITER-like wall divertor

Considering reflections from metallic wall surfaces in generation of tomographic reconstructions of the tangentially viewing, visible-range spectroscopic divertor cameras in JET has been observed to yield enhanced spatial accuracy and significant reduction of emission artifacts in experimentally resolved 2D line emission distributions. Neglection of reflections in the tomography process was found to lead to overestimation of the emission near the wall surfaces by up to a factor of 4, as well as to formation of bright emission artifacts between the main emission regions and the wall surfaces, comprising locally up to 50% of the emission. Mimicking divertor spectroscopy measurements by integrating the tomographic reconstructions along vertical lines-of-sight implies that reflections comprise 15%–25% of the observed line-integrated emission peaks. Additionally, the spatial differences in the reflection contribution between the different lines-of-sight are less pronounced than in the 2D reconstructions due to the dominance of the brightest emission regions through which the spectroscopic lines-of-sight pass. However, postprocessing EDGE2D-EIRENE simulations using the CHERAB code and synthetic spectroscopy suggests a decrease of the spectroscopically inferred divertor electron temperature by up to 75%, when redistribution of the observed light due to reflections is considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of 3D cryoEM single-particle reconstruction correctness and handedness with Ewald's sphere correction

The correct description of quantum scattering places the observed scattering contributions on the Ewald's sphere and its Friedel mate copy. In electron microscopy, due to the large radius of the Ewald's sphere, these scattering contributions are typically merged during data analysis. We present an approach that separates and factorizes those contributions into real and imaginary components of the image. When an inverted solution is calculated, the map derived from the real component of the image generates an inverted solution, while the map derived from the imaginary component of the image generates an inverted and sign-flipped solution. Therefore, the sign of correlation between reconstructions derived from the real and imaginary components provides the automatic determination of handedness and additional validation for the quality of 3D reconstructions. The factorization and its implementation are robust enough to be routinely used in single-particle reconstructions, even at resolutions below the limit where the curvature of the Ewald's sphere affects the overall signal-to-noise ratio.

Chemistry↗