Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Is Robotic-Assisted Surgery Safe in the Elderly Population? An Analysis of Gynecologic Procedures in Patients ≥ 65 Years Old

Background: The elderly population is expanding worldwide but is underrepresented in clinical trials. We sought to assess the safety of robotic gynecologic surgery in an elderly cohort and to identify factors associated with unfavorable outcomes. Methods: All patients ≥ 65 years who underwent a robotically assisted procedure at a single institution between May 2007 to December 2016 were divided into three age groups: 65–74 (Group 1); 75–84 (Group 2); ≥ 85 (Group 3). Perioperative outcomes were recorded in patients who did not require conversion to laparotomy. We compared clinical variables among groups and performed multivariate logistic regression to detect variables associated with major complications (≥ Grade 3) or 90-day mortality. Results: We retrospectively identified 982 cases: 685 in Group 1; 249 in Group 2; 48 in Group 3. Median age = 71 years. Median BMI = 28.9. Malignancy was documented in 72.8% of cases; the majority were endometrial cancer (61.8%). Thirty-four patients (3.5%) were readmitted within 30 days. Seventy-seven (7.8%) had a postoperative complication, and 23 (2.3%) had a major complication. Ninety-day mortality was 0.5%. There was significant difference between groups with respect to body mass index (P = 0.026), ECOG PS (P ≤ 0.001), > 5 comorbidities (P = 0.005), hospital stay (P < 0.001), major complications (P = 0.001), and 90-day mortality (P < 0.001). On multivariable logistic regression, age ≥ 85 years was associated with major complications. Body mass index, age ≥ 85 years, and major complications were significantly associated with 90-day mortality. Conclusions: Robotic-assisted surgery appears to be safe in an elderly cohort. The incidence of overall and major complications is consistent with those reported in the literature. Patients ≥ 85 years old appear to be at higher risk of unfavorable outcomes.

60 APPLIED LIFE SCIENCES↗

Efficient Sampling Allocation Procedures for Optimal Quantile Selection

We propose a dynamic sampling allocation and selection paradigm for finding the alternative with the optimal quantile in a Bayesian framework. Myopic allocation policies (MAPs), analogous to existing methods in classic ranking and selection for selecting the alternative with the optimal mean, and computationally efficient selection policies are derived for selecting the alternative with the optimal quantile. Under certain conditions, we prove that the proposed MAPs and selection procedures are consistent, which means that the best quantile would be eventually correctly selected as the sample size goes to infinity. Numerical experiments demonstrate that the proposed schemes can significantly improve the performance.

Computer Science↗

Methods and Procedures for Shielding Analyses for the SNS

In order to provide radiologically safe Spallation Neutron Source operation, shielding analyses are performed according to Oak Ridge National Laboratory internal regulations and to comply with the Code of Federal Regulations. An overview of on-going shielding work for the accelerator facility and neutrons beam lines, methods, used for the analyses, and associated procedures and regulations is presented. Methods used to perform shielding analyses are described as well.

43 PARTICLE ACCELERATORS↗

Optimization of a Welding Procedure for Making Critical Aluminum Welds on the LBNF Absorber Core Block

The LBNF Absorber consists of thirteen 6061-T6 aluminum core blocks. The core blocks are water cooled with de-ionized (DI) water which becomes radioactive during beam operations. The cooling water flows through gun-drilled channels in the core blocks. A weld quality optimization was performed to produce National Aeronautical Standard 1514 Class I quality welds on the aluminum core blocks. This was not successful in all cases. An existing Gas Tungsten Arc Welding Procedure Specification was fine tuned to minimize, in most cases, and eliminate detect-able tungsten inclusions in the welds. All the weld coupons, however passed welding inspection as per the piping code: ASME B31.3 Normal Fluid Service. Tungsten electrode diameter, type, and manufacturer were varied. Some of the samples were pre-heated and others were not. It was observed that larger diameter electrodes, 5/32 in., with pre-heated joints resulted in welds with the least number of tungsten inclusions. It is hypothesized that thinner electrodes breakdown easily and get lodged into the weld pool during the welding process. This breakdown is further enhanced by the large temperature differential between the un-preheated sample and the hot electrode.

43 PARTICLE ACCELERATORS↗

Extending the Remote Control Capabilities in the CMS Detector Control System with Remote Procedure Call Services

The CMS Detector Control System (DCS) is implemented as a large distributed and redundant system, with applications interacting and sharing data in multiple ways. The CMS XML-RPC is a software toolkit implementing the standard Remote Procedure Call (RPC) protocol, using the Extensible Mark-up Language (XML) and a custom lightweight variant using the JavaScript Object Notation (JSON) to model, encode and expose resources through the Hypertext Transfer Protocol (HTTP). The CMS XML-RPC toolkit complies with the standard specification of the XML-RPC protocol that allows system developers to build collaborative software architectures with self-contained and reusable logic, and with encapsulation of well-defined processes. The implementation of this protocol introduces not only a powerful communication method to operate and exchange data with web-based applications, but also a new programming paradigm to design service-oriented software architectures within the CMS DCS domain. This paper presents details of the CMS XML-RPC implementation in WinCC Open Architecture (OA) Control Language using an object-oriented approach.

43 PARTICLE ACCELERATORS↗

Practical procedures for sensor quality assessment

Sensors are increasingly deployed for process monitoring and control. These produce on-line measurements at a high frequency, in parallel with low-frequency laboratory measurements. Compared to laboratory practices, sensor data quality assessment and control practices are far less structured at most utilities. This leads to inaccurate sensor data with unknown uncertainty factors.This chapter shows how to establish standard operating procedures (SOPs) to support sensor data quality assessment and control and subsequent maintenance actions by producing relevant sensor metadata. Furthermore, SOPs are provided for the most commonly used wastewater quality sensors, inspired by utility and academic best practices. This chapter builds on definitions provided in Chapter 3 and provides additional definitions specifically related to sensors maintenance. Chapter 6 complements the methods in this chapter, which are based on reference measurements, with data-analytical techniques.

Alferes, Janelcy↗

The Oncor Geodatabase for the Columbia Estuary Ecosystem Restoration Program: Handbook of Data Reduction Procedures, Workbooks, and Exchange Templates

This Handbook of Data Reduction Procedures, Workbooks, and Exchange Templates is designed to support the Oncor geodatabase for the Columbia Estuary Ecosystem Restoration Program (CEERP). The following data categories are covered: water-surface elevation and temperature, sediment accretion rate, photo points, herbaceous wetland vegetation cover, tree plots and site summaries, fish catch and density, fish size, fish diet, fish prey, and Chinook salmon genetic stock identification. The handbook is intended for use by scientists collecting monitoring and research data for the CEERP. The ultimate goal of Oncor is to provide quality, easily accessible, geospatial data for synthesis and evaluation of the collective performance of CEERP ecosystem restoration actions at a program scale.

54 ENVIRONMENTAL SCIENCES↗

Brookhaven National Laboratory meteorological services instrument calibration plan and procedures

This document describes the Meteorological Services (Met Services) Calibration and Maintenance Schedule and Procedures, The purpose is to establish the frequency and mechanism for the calibration and maintenance of the network of meteorological instrumentation operated by Met Services. The goal is to maintain the network in a manner that will result in accurate, precise and reliable readings from the instrumentation.

54 ENVIRONMENTAL SCIENCES↗

Quality Assurance Procedures for ModCat Database Code Files

The Quality Assurance procedures used for the initial phase of the Model Catalog Project were developed to attain two objectives, referred to as “basic functionality” and “visualization.” To ensure the Monte Carlo N-Particle model input files posted into the ModCat database meet those goals, all models considered as candidates for the database are tested, revised, and re-tested.

MCNP↗

Production Pathways and Separation Procedures for High-Diagnostic-Value Activation Species, Fission Products, and Actinides Required for Preparation of Realistic Synthetic Post-Detonation Nuclear Debris: Status Report and FY16 Project Plan

The objective of this project is to provide a comprehensive study on the production routes and chemical separation requirements for activation products, fission products, and actinides required for the creation of realistic post-detonation surrogate debris. Isotopes that have been prioritized by debris diagnosticians will be examined for their ability to be produced at existing irradiation sources, production rates, and availability of target materials, and chemical separation procedures required to rapidly remove the products from the bulk target matrix for subsequent addition into synthetic debris samples. The characteristics and implications of the irradiation facilities on the isotopes of interest will be addressed in addition to a summary of the isotopes that are already regularly produced. This is a planning document only.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

PLAN-TA9-2443(U), Rev. B Remediated Nitrate Salt (RNS) Surrogate Formulation and Testing Standard Procedure

This document identifies scope and some general procedural steps for performing Remediated Nitrate Salt (RNS) Surrogate Formulation and Testing. This Test Plan describes the requirements, responsibilities, and process for preparing and testing a range of chemical surrogates intended to mimic the energetic response of waste created during processing of legacy nitrate salts. The surrogates developed are expected to bound1 the thermal and mechanical sensitivity of such waste, allowing for the development of process parameters required to minimize the risk to worker and public when processing this waste. Such parameters will be based on the worst-case kinetic parameters as derived from APTAC measurements as well as the development of controls to mitigate sensitivities that may exist due to friction, impact, and spark. This Test Plan will define the scope and technical approach for activities that implement Quality Assurance requirements relevant to formulation and testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WalkThrough Example Procedures for MAMA

This documentation is a growing set of walk through examples of analyses using the MAMA V2.0 software. It does not cover all the features or possibilities with the MAMA software, but will address using many of the basic analysis tools to quantify particle size and shape in an image. This document will continue to evolve as additional procedures and examples are added. The starting assumption is that the MAMA software has been successfully installed.

97 MATHEMATICS AND COMPUTING↗

Instrument Calibration and Certification Procedure

The Amptec 640SL-2 is a 4-wire Kelvin failsafe resistance meter, designed to reliably use very low-test currents for its resistance measurements. The 640SL-1 is a 2-wire version, designed to support customers using the Reynolds Industries type 311 connector. For both versions, a passive (analog) dual function DC Milliameter/Voltmeter allows the user to verify the actual 640SL output current level and the open circuit voltage on the test leads. This procedure includes tests of essential performance parameters. Any malfunction noticed during calibration, whether specifically tested for or not, shall be corrected before calibration continues or is completed.

47 OTHER INSTRUMENTATION↗