Exascale Multiphysics Nuclear Reactor Simulations for Advanced Designs

ENRICO is a coupled application developed under the U.S. Department of Energy's Exascale Computing Project (ECP) targeting the modeling of advanced nuclear reactors. It couples radiation transport with heat and fluid simulation, including the high-fidelity, highresolution Monte-Carlo code Shift and the Computational fluid dynamics code NekRS. NekRS is a highly-performant open-source code for simulation of incompressible and low-Mach fluid flow, heat transfer, and combustion with a particular focus on turbulent flows in complex domains. It is based on rapidly convergent high-order spectral element discretizations that feature minimal numerical dissipation and dispersion. State-of-the-art multilevel preconditioners, efficient high-order time-splitting methods, and runtime-adaptive communication strategies are built on a fast OCCA-based kernel library, libParanumal, to provide scalability and portability across the spectrum of current and future high-performance computing platforms. On Frontier, Nek5000/RS has recently achieved an unprecedented milestone in breaching over 1 billion spectral elements and 350 billion degrees of freedom. Shift has demonstrated the capability to transport upwards of 1 billion particles per second in full core nuclear reactor simulations featuring complete temperature-dependent, continuous-energy physics on Frontier. Shift achieved a weak-scaling efficiency of 97.8% on 8192 nodes of Frontier and calculated 6 reactions in 214,896 fuel pin regions below 1% statistical error yielding first-of-a-kind resolution for a Monte Carlo transport application.

Hamilton, Steven P.↗

Rigid-Rod Sulfonated Polyamide as an Aqueous-Processable Binder for Li-Ion Battery Electrodes

Polymer binders are important components of most battery electrodes, ensuring high performance and long-term durability. Increasing demand for lithium-ion batteries in the automotive, stationary power, and portable electronics industries calls for a greener binder to replace poly(vinylidene difluoride) (PVDF). We evaluate the performance of aqueous solution-processed electrodes prepared with a rigid-rod polymer binder, poly(2,2'-disulfonyl-4,4'-benzidine terephthalamide) (PBDT). The polyamide backbone and double-helical configuration of PBDT give rise to its mechanical strength and rigidity, and its functional nature (H-bonding amides and sulfonates) can provide specific binding with electrode particles. LiFePO 4 electrodes prepared with 3 wt% PBDT show mechanical integrity and cycling stability, achieving over 1000 cycles at 4C rate with negligible capacity decay. These electrodes demonstrate comparable rate performance with their PVDF counterparts while eliminating fluorine from the electrode as well as the organic solvents needed for processing. Furthermore, this study reveals that PBDT holds great potential as a binder for advanced sustainable batteries.

25 ENERGY STORAGE↗

State-of-the-art Thin Film Electrolytes For Solid Oxide Fuel Cells

State-of-the-Art solid oxide fuel cells (SOFC) are amongst the main candidates for clean energy technology due to their high efficiency, fuel flexibility, low air pollution, and minimal greenhouse gas emission. However, high operational temperature of SOFC is a greater challenge in commercialization these devices for low cost and portable applications. High temperature operation of SOFC degrades its performance with aging, limits the selection of materials for fuel cell components, and increases the fabrication cost. Thus, there have been enormous efforts to improve the properties of existing materials and develop new materials for SOFC components in order to lower the operating temperature of SOFC. Recent advances in thin film technology have also been utilized to develop new materials with improved properties for SOFC. One of the key components in SOFC is the electrolyte and several research groups are working on developing new electrolyte materials. In this chapter, we will discuss the recent advances in thin film SOFC electrolytes. This extensive discussion includes the evolution of doped ceria, doped zirconia, and multilayer hetero-structured thin film electrolytes. The newly developed nanoscale thin films and multi-layer hetero-structures with improved oxygen ionic conductivity will have significant impact on SOFC devices.

Thevuthasan, Suntharampillai↗

Reconfigurable acquisition system with integrated optics for a portable flow cytometer

Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-color excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.

60 APPLIED LIFE SCIENCES↗

A Micro-Thermionic Ionization Source for Chemical Detection

The major goal of this project was to develop an ionization-based detector that could be integrated into the portable gas chromatography systems currently produced by Defiant Technologies. This new detector would allow Defiant to analyze a broader range of analytes and enter new markets. There was also an interest in testing the new ionization source in an ion mobility spectrometer (IMS) that is produced by Sandia National Laboratories. Not only could this eliminate the need for a radioactive material in the IMS, it would offer Defiant the opportunity to add a whole new product line to their chemical analysis systems. Significant progress was made in the development of a thermionic ionization source (TIS) and detector. Using a MEMs heater was an attractive concept, but it proved to be an unfruitful approach because of the fragility of the devices at elevated temperatures. A rugged alternative heater was developed using nichrome wire and alumina tubes. These heaters are simple to make, and, for low quantity production, will be considerably cheaper to construct than MEMs devices. This work has provided a firm basis for follow-on projects. There is now a solid concept for constructing heater elements where, prior to this work, there was only the hope that MEMs heaters would work. In addition, the electrometer that was developed works better than the commercial rack-mounted system that was originally used in this study. Overcoming these two obstacles provides a clear technical approach for product development. There will be follow on efforts at Defiant Technologies to refine the development of the thermal ionization detector. Designs are being made to combine the TIS and electrometer electronics into a single package with a simple-to-replace TIS element. Further work will also focus on integrating this new detector into portable gas chromatography products and testing to optimize the performance.

47 OTHER INSTRUMENTATION↗

Simulating Scenes In Outer Space

Multimission Interactive Picture Planner, MIP, computer program for scientifically accurate and fast, three-dimensional animation of scenes in deep space. Versatile, reasonably comprehensive, and portable, and runs on microcomputers. New techniques developed to perform rapidly calculations and transformations necessary to animate scenes in scientifically accurate three-dimensional space. Written in FORTRAN 77 code. Primarily designed to handle Voyager, Galileo, and Space Telescope. Adapted to handle other missions.

Callahan, John D.↗

Development of a miniaturized, light-weight magnetic sector for a field-portable mass spectrograph

A miniaturized, lightweight magnetic sector for a focal plane mass spectrograph (Mattauch-Herzog design) has been designed and fabricated by using a new high-energy-product magnet material (Nd-B-Fe alloy) and a high permeability magnet yoke material (V-Co-Fe alloy). The magnetic sector weighs less than 10 kg, has a focal plane of 5.1 cm in length, and covers a nominal mass range of 40-240 amu. Such a magnetic sector, in conjunction with an array detector and a short microbore capillary column, is well suited for the development of a field-portable gas chromatograph-mass spectrometer instrument of high performance.

Sinha, M. P.↗

Next generation optical instruments and space experiment based on the LDEF thermal control surfaces experiment (S0069)

The Thermal Control Surfaces Experiment (TCSE) was a successful experiment to study the effects of the space environment on thermal control surfaces using in-space optical properties measurements combined with post-flight analyses. The TCSE reflectometer performed well on the LDEF mission demonstrating that a portable compact integrating sphere spectroreflectometer can be built that is rugged and space rated. Since the retrieval of the TCSE package from space, several other instruments have evolved from its pioneering technologies. These are the Optical Properties Monitor (OPM), the Laboratory Portable SpectroReflectometer (LPSR), and the Space Portable SpectroReflectometer (SPSR). These instruments and experiment packages are described.

Wilkes, Donald R.↗

Implementing Multidisciplinary and Multi-Zonal Applications Using MPI

Multidisciplinary and multi-zonal applications are an important class of applications in the area of Computational Aerosciences. In these codes, two or more distinct parallel programs or copies of a single program are utilized to model a single problem. To support such applications, it is common to use a programming model where a program is divided into several single program multiple data stream (SPMD) applications, each of which solves the equations for a single physical discipline or grid zone. These SPMD applications are then bound together to form a single multidisciplinary or multi-zonal program in which the constituent parts communicate via point-to-point message passing routines. Unfortunately, simple message passing models, like Intel's NX library, only allow point-to-point and global communication within a single system-defined partition. This makes implementation of these applications quite difficult, if not impossible. In this report it is shown that the new Message Passing Interface (MPI) standard is a viable portable library for implementing the message passing portion of multidisciplinary applications. Further, with the extension of a portable loader, fully portable multidisciplinary application programs can be developed. Finally, the performance of MPI is compared to that of some native message passing libraries. This comparison shows that MPI can be implemented to deliver performance commensurate with native message libraries.

Fineberg, Samuel A.↗

Tools to Rapidly and Effectively Parallelise Serial FORTRAN Codes Using Either MPI or OpenMP

Significant progress has been made in hardware and software technologies, as a result the use of efficient standard message passing communication calls in parallel application codes has greatly assisted in reducing execution times. In addition, the introduction of OpenMP, an industrial standard for shared memory programming with directives addresses the issue of portability and also provides a means to deliver respectable performance. In general however, the manual parallelisation of a user's application code using either message passing or directives is still a very costly and error-prone process.

Jin, Hao-Qiang↗

Real-Time Payload Control and Monitoring on the World Wide Web

World Wide Web (W3) technologies such as the Hypertext Transfer Protocol (HTTP) and the Java object-oriented programming environment offer a powerful, yet relatively inexpensive, framework for distributed application software development. This paper describes the design of a real-time payload control and monitoring system that was developed with W3 technologies at NASA Ames Research Center. Based on Java Development Toolkit (JDK) 1.1, the system uses an event-driven "publish and subscribe" approach to inter-process communication and graphical user-interface construction. A C Language Integrated Production System (CLIPS) compatible inference engine provides the back-end intelligent data processing capability, while Oracle Relational Database Management System (RDBMS) provides the data management function. Preliminary evaluation shows acceptable performance for some classes of payloads, with Java's portability and multimedia support identified as the most significant benefit.

Sun, Charles↗

Supplemental Systems for Unattended UF6 Cylinder Monitoring

Cylinder assay and mass measurements, the mainstay of enrichment plant verification efforts have historically been performed by International Atomic Energy Agency (IAEA) inspectors using portable equipment. For the sake of efficiency, accuracy, and timeliness, such equipment is being supplanted by unattended measurement stations. Ancillary systems must be employed with such stations to ensure that measured parameters are properly recorded, cylinders are positively identified, operations occur according to procedure, and no tampering takes place in the inspectors’ absence. Depending on the facility, it may prove feasible to track cylinders from the measurement vicinity to their storage locations using surveillance. This paper will provide a cursory description of the various subsystems associated with Pacific Northwest National Laboratory’s Integrated Cylinder Verification Station and how inattention to the requirements of such systems could seriously diminish the capability of the integrated whole.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Autonomous Magnetometer Rotorcraft For Wide Area Assessment

Large areas across the United States and internationally are potentially contaminated with unexploded ordinance (UXO), with some ranges encompassing tens to hundreds of thousands of acres. Technologies are needed which will allow for cost effective wide area scanning with (1) near 100% coverage and (2) near 100% detection of subsurface ordnance or features indicative of subsurface ordnance. The current approach to wide area assessment is a multi-level one, in which medium - altitude fixed wing optical imaging is used for an initial site assessment. This assessment is followed with low altitude manned helicopter based magnetometry. Subsequent to this wide area assessment targeted surface investigations are performed using either towed geophysical sensor arrays or man portable sensors. In order to be an effective tool for small UXO detection, the sensing altitude for magnetic site investigations needs to be on the order of 1 to 3 meters. These altitude requirements mean that manned helicopter surveys will generally only be feasible in large, open and relatively flat terrains. While such surveys are effective in mapping large areas relatively fast there are substantial mobilization/demobilization, staffing and equipment costs associated with these surveys, resulting in costs of approximately $100-$150/acre. In addition, due to the low altitude there are substantial risks to pilots and equipment. Surface towed arrays provide highresolution maps but have other limitations, e.g. in their ability to navigate rough terrain effectively. Thus there is a need for other systems, which can be used for effective data collection. An Unmanned Aerial Vehicle (UAV) magnetometer platform is an obvious alternative. The motivation behind such a system is that it reduces risk to operators, is lower in initial and Operational and Maintenance (O&M) costs (and can thus potentially be applied to smaller sites) and has the potential of being more effective in terms of detection and possibly characterization (through the use of dynamic acquisition, i.e. survey mission in-flight reprioritization).

58 GEOSCIENCES↗

Use of XRF to characterize pre-Hanford orchards in the 100-OL-1 operable unit - 15717

Prior to 1943, Hanford site included several small towns with approximately 5,000 acres of orchards; at the time lead arsenate (PbHAsO{sub 4}) was the most commonly used pesticide. High concentration of lead and arsenic have been recorded where trees and stumps are still visible. Pre-Hanford orchards have been designated as 100-OL-1 Operable Unit. An Optimization study evaluated optimal counting time and position of the XRF from soils collected at the site. A Pilot Study included the evaluation of a field portable x-ray fluorescence (XRF) analyzer determining if performance results meet quality assurance criteria for cleanup. XRF has only previously been used as a screening tool. Four Decision Units (DUs) are to be analyzed: Ol-14. OL-32. OL-IU6-4 and OL-FR2-1. The DUs vary in size and have had distinct historic activities; such as 46.4 acres OL-14 having a military camp in the 1950's unlike OL-FR2-1 having been disturbed as it is near the F area reactor. Together the DUs provide an adequate representation of the Operable Unit. Screening criteria for lead (250 mg/kg) and arsenic (20 mg/kg). Six samples were collected ranging above, at, and below the screening criteria of 250 mg/kg for Pb and 20 mg/kg for As at the Decision Units OL-14 and OL-IU6-4, and labeled respectively. Samples were hand sieved, homogenized and placed in sample cups. Three replicates were prepared for each sample. Each sample cup was analyzed 3 times for 30 sec. A Standard Reference Material (SRM) was analyzed after every 20 readings. Three samples were selected for 15, 30, 45, 60, 90, 120, 150 and 180 second fixed and variable analysis. Two transects at OL-14, and one at OL-IU6-4 were created by selecting locations 90. around ground zero at distances of 0.5, 1, 2, 4, 8 and 12 feet (16 ft for OL-14). Locations were scanned in triplicate for 60 seconds each. 4 Decision Units spanning roughly 370 acres were chosen to represent 100-OL-1 Operable Unit. 40 locations within each DU were selected using Visual Sample Plan (VSP) with a random start and systematic grid pattern. Each location would be analyzed with 3 replicates and a 60 second count time. The Standard Reference Material (SRM) and blank are analyzed after every 20 counts to ensure accuracy. Data is extracted from XRF to be implemented in GIS for visual representation of site with 1943 and 2013 aerial imagery. Discussion/Conclusion: - XRF provided a good indication of precision and accuracy relative to ICP with a linear correlation R{sup 2} value higher than anticipated at .9735; - MDL proved the detection limit is significantly lower than the screening criteria; - When comparing results from the first 40 locations of OL-14 to the total 80 locations of OL-14, the same variability was seen; - We expect high concentrations of Pb and As to be where past orchards are present though this does not occur as all sites. Significance: - XRF is competent for decision making as values fall within ±20% ICP data; - The highest concentrations are not where expected, which may be an issue for sites outside of Hanford that have had more development; - The size of the DU does not affect the number of samples measured. Future Work: - Verification and validation of the XRF Data (QA/QC); - Revise conceptual site model; - Statistical evaluations to investigate: Estimation of variability in surface soils, appropriate size for DU, and sample size per DU; - Coordinating sample results through CORE; - Displaying sample results in PHOENIX (GIS tool)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Medical Science DMZ

Objective We describe use cases and an institutional reference architecture for maintaining high-capacity, data-intensive network flows (e.g., 10, 40, 100 Gbpsþ) in a scientific, medical context while still adhering to security and privacy laws and regulations. Materials and Methods High-end networking, packet filter firewalls, network intrusion detection systems. Results We describe a “Medical Science DMZ” concept as an option for secure, high-volume transport of large, sensitive data sets between research institutions over national research networks. Discussion The exponentially increasing amounts of “omics” data, the rapid increase of high-quality imaging, and other rapidly growing clinical data sets have resulted in the rise of biomedical research “big data.” The storage, analysis, and network resources required to process these data and integrate them into patient diagnoses and treatments have grown to scales that strain the capabilities of academic health centers. Some data are not generated locally and cannot be sustained locally, and shared data repositories such as those provided by the National Library of Medicine, the National Cancer Institute, and international partners such as the European Bioinformatics Institute are rapidly growing. The ability to store and compute using these data must therefore be addressed by a combination of local, national, and industry resources that exchange large data sets. Maintaining data-intensive flows that comply with HIPAA and other regulations presents a new challenge for biomedical research. Recognizing this, we describe a strategy that marries performance and security by borrowing from and redefining the concept of a “Science DMZ”—a framework that is used in physical sciences and engineering research to manage high-capacity data flows. Conclusion By implementing a Medical Science DMZ architecture, biomedical researchers can leverage the scale provided by high-performance computer and cloud storage facilities and national high-speed research networks while preserving privacy and meeting regulatory requirements.

97 MATHEMATICS AND COMPUTING↗

Passenger Transmitters as A Possible Cause of Aircraft Fuel Ignition

An investigation was performed to study the potential for radio frequency (RF) power radiated from transmitting Portable Electronic Devices (PEDs) to create an arcing/sparking event within the fuel tank of a large transport aircraft. A survey of RF emissions from typical intentional transmitting PEDs was first performed. Aircraft measurements of RF coupling to the fuel tank and its wiring were also performed to determine the PEDs induced power on the wiring, and the re-radiated power within the fuel tank. Laboratory simulations were conducted to determine the required RF power level for an arcing/sparking event. Data analysis shows large positive safety margins, even with simulated faults on the wiring.

Nguyen, Truong X.↗