Predictors of Trigeminal Neuropathy After Radiosurgery for Vestibular Schwannomas
Purpose: To analyze the relationship between dosimetric characteristics and symptoms related to trigeminal neuropathy (TN) observed after radiosurgery (RS) for vestibular schwannomas (VS); to propose guidelines to optimize planification in VS RS regarding TN preservation; and to detail the mechanism of TN impairment after VS RS. Methods and Materials: One hundred seventy-nine patients treated between 2011 and 2013 for VS RS and without trigeminal impairment before RS were included in a retrospective study. Univariate and multivariate analyses were performed to determine predictors of TN among characteristics of the patients, the dosimetry, and the VS. Results: There were 20 Koos grade 1, 99 grade 2, 57 grade 3, and 3 grade 4. Fourteen patients (7.8%) presented a transitory or permanent TN. Between the patients with and without TN after VS RS, there was no significant difference regarding dosimetry or VS volume itself. Significant differences (univariate analysis P<.05, Mann-Whitney test) were found for parameters related to the cisternal portion of the trigeminal nerve: total integrated dose, maximum dose, mean dose, volume of the Vth nerve (Vol{sub v}), and volume of the Vth nerve receiving at least 11 Gy (Vol{sub Vcist>11Gy}), but also for maximal dose to the Vth nerve nucleus and intra-axial portion (Dose max{sub Vax}). After multivariate analysis, the best model predicting TN included Vol{sub Vcist>11Gy} (P=.0045), Dose max{sub Vax} (P=.0006), and Vol{sub v} (P=.0058). The negative predictive value of this model was 97%. Conclusions: The parameters Vol{sub Vcist>11Gy}, Dose max{sub Vax}, and Vol{sub v} should be checked when designing dosimetry for VS RS.