Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Behavioral Determinants of Canadian Radiation Oncologists’ Use of Single Fraction Palliative Radiation Therapy for Uncomplicated Bone Metastases

A mainstay therapy for pain relief from uncomplicated bone metastases is external beam radiation therapy. Single fraction radiation therapy (SFRT) is more convenient and cost-effective, causes fewer acute side effects, and is equivalent to multiple fraction radiation therapy for pain relief. Despite these advantages, radiation oncologists seldom prescribe SFRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Content-aware foveated camera for multi-target tracking

Modern image sensors deliver substantial space-time bandwidth, yet indiscriminate acquisition often overwhelms memory, computation, and downstream perception. We present a content-aware, multi-foveated camera that dynamically reallocates sensing and magnification to multiple regions of interest (ROIs). A phase-only spatial light modulator (SLM) serves as a solid-state, inertia-free beam-steering and lens element, enabling per-frame field-of-view (FOV) reconfiguration and content-aware target tracking. By interleaving frames across foveae, our system preserves a wide-FOV situational context while refreshing each ROI at high rates, thereby reducing data volume without degrading task performance. We constructed a prototype employing a single-SLM, single-sensor architecture and demonstrated its application in real-time multi-object tracking with dynamic ROI maintenance across multiple viewpoints. The approach offers a general pathway to integrate detection, tracking, and segmentation algorithms in the acquisition loop, shifting workload from post hoc processing to intelligent capture.

Zang, Zihan [Univ. of California, Los Angeles, CA ↗

Measurement of nuclear interaction cross sections towards neutron-skin thickness determination

The accuracy of reaction theories used to extract properties of exotic nuclei from scattering experiments is often unknown or not quantified, but of utmost importance when, e.g., constraining the equation of state of asymmetric nuclear matter from observables as the neutron-skin thickness. In order to test the Glauber multiple-scattering model, the total interaction cross section of 12 C on carbon targets was measured at initial beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The measurements were performed during the first experiment of the newly constructed R 3 B (Reaction with Relativistic Radioactive Beams) experiment after the start of FAIR Phase-0 at the GSI/FAIR facility with beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The combination of the large-acceptance dipole magnet GLAD and a newly designed and highly efficient Time-of-Flight detector enabled a precise transmission measurement with several target thicknesses for each initial beam energy with an experimental uncertainty of ±0.4%. A comparison with the Glauber model revealed a discrepancy of around 3.1% at higher beam energies, which will serve as a crucial baseline for the model-dependent uncertainty in future fragmentation experiments.

Astronomy & Astrophysics↗

Driving in the dark: Deciphering nighttime driver detection of free-ranging roadside wildlife

Wildlife-vehicle collisions are dangerous for motorists; however, few studies have addressed driver detection of roadside animals, and none have evaluated detection of free-ranging wildlife. Here, we used 24 volunteer drivers, infrared videography, a 75-km route, and free-ranging wildlife to quantify factors influencing (1) probability of wildlife detection, (2) detection distance, and (3) probability of dangerous encounters (i.e., detection distance < distance required for braking) for multiple species at night in South Carolina, USA. Detection probability of white-tailed deer (Odocoileus virginianus) was impacted by multiple driver, animal, and roadside factors. Deer detection distances increased by 20.99 m when drivers used high-beam headlights and 23.36 m when deer were moving but decreased by 0.71 m for every minute into a drive. Every encounter with wild pigs (Sus scrofa) and most encounters with small mammals were considered dangerous. Our findings suggest most drivers cannot safely detect deer, wild pigs, and small mammals at night.

54 ENVIRONMENTAL SCIENCES↗

A research program to measure the lifetime of spin polarized fuel

The use of spin polarized fuel could increase the deuterium-tritium (D-T) fusion cross section by a factor of 1.5 and, owing to alpha heating, increase the fusion power by an even larger factor. Issues associated with the use of polarized fuel in a reactor are identified. Theoretically, nuclei remain polarized in a hot fusion plasma. The similarity between the Lorentz force law and the Bloch equations suggests polarization can be preserved despite the rich electromagnetic spectrum present in a magnetic fusion device. The most important depolarization mechanisms can be tested in existing devices. The use of polarized deuterium and 3 He in an experiment avoids the complexities of handling tritium, while encompassing the same nuclear reaction spin-physics, making it a useful proxy to study issues associated with full D-T implementation. 3 He fuel with 65% polarization can be prepared by permeating optically-pumped 3 He into a shell pellet. Dynamically polarized 7 Li-D pellets can achieve 70% vector polarization for the deuterium. Cryogenically-frozen pellets can be injected into fusion facilities by special injectors that minimize depolarizing field gradients. Alternatively, polarized nuclei could be injected as a neutral beam. Once injected, the lifetime of the polarized fuel is monitored through measurements of escaping charged fusion products. Multiple experimental scenarios to measure the polarization lifetime in the DIII-D tokamak and other magnetic-confinement facilities are discussed, followed by outstanding issues that warrant further study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effects of exposure to LN2 temperatures and 2.5 suns solar radiation on 30-cm ion thruster performance

An experimental test program was developed to demonstrate all 30 cm Hg-ion bombardment thruster functions over the thermal environment of several proposed missions. A 30 cm thruster with grids dished 1.25 cm and instrumented with 31 thermocouples, was placed in a vacuum tank equipped with minus 196 C walls. Cold storage of a thruster was simulated and temperatures as low as minus 100 C were attained on the thruster. The thruster started successfully from these cold conditions. The thruster operating at both half and full beam power was exposed to 2.5 suns on axis solar simulation. Various thruster thermal configurations, used to simulate multiple thruster operation, were tested at the above conditions. The results of these tests are reported herein.

Mirtich, M. J.↗

The effects of exposure to LN2 temperatures and 2.5 suns solar radiation on 30-cm ion thruster performance

An experimental test program was developed to demonstrate all 30 cm Hg-ion bombardment thruster functions over the thermal environment of several proposed missions. A 30 cm thruster with grids dished 1.25 cm and instrumented with 31 thermocouples, was placed in a vacuum tank equipped with -196 C walls. Cold storage of a thruster was simulated and temperatures as low as -100 C were attained on the thruster. The thruster started successfully from these cold conditions. The thruster operating at both half and full beam power was exposed to 2.5 suns on axis solar simulation. Various thruster thermal configurations, used to simulate multiple thruster operation, were tested at the above conditions. The results of these tests are reported herein.

Mirtich, M. J.↗

Land vehicle antennas for satellite mobile communications

Antenna designs applicable to future satellite mobile vehicle communications are examined. Microstrip disk, quadrifilar helix, cylindrical microstrip, and inverted V and U crossed-dipole low gain antennas (3-5 dBic) that provide omnidirectional coverage are described. Diagrams of medium gain antenna (9-12 dBic) concepts are presented; the antennas are classified into three types: (1) electronically steered with digital phase shifters; (2) electronically switched with switchable power divider/combiner; and (3) mechanically steered with motor. The operating characteristics of a conformal antenna with electronic beam steering and a nonconformal design with mechanical steering are evaluated with respect to isolation levels in a multiple satellite system. Vehicle antenna pointing systems and antenna system costs are investigated.

Haddad, H. A.↗

Hard ACTS to follow

The Advanced Communications Technology Satellite (ACTS), the third phase of NASA's 30/20 GHz satellite communications program, is praised for its frugal usage of both the geosynchronous orbital arch and the frequency spectrum resources necessary for communications satellites. Its objective is to verify Ka-band satellite communications concepts and to develop a flight and ground system for validation of the multibeam communications proof-of-concept technologies. The ACTS ground segment (comprised of four types of terminals) is designed to compliment the spacecraft for the SS launch in 1989. Precise coordination between the ground and spacecraft segments is performed by the baseband processor (BBP), which is an in-orbit switchboard, and the tracking error word, which enables the ground terminals to remain synchronized with onboard timing. Fixed spot beams and scan beams, comprising the two types of spot beams used, both operate at the same frequency and hence, conserve frequency resources. In addition, the time division multiple access serves to enhance system efficiency. It is concluded that Ka-band satellites are a practical approach to the better usage of those resources potentially threatened by communications satellites. Comprehensive graphs and block diagrams of the system are included.

Moy, L.↗

A high resolution spectrometer for EUV/FUV wavelengths

The most efficient of the various configurations considered for a high-resolution spaceborne spectrometer for point-source astronomy in the 400-1200-A wavelength region which will fit within an envelope defined by the projected Spartan space platform is a multiple Rowland circle spectrograph, with each of four toroidal gratings respectively intercepting a fraction of the primary mirror beam. Each spectrometer can accept a rather slowly diverging beam, reducing grating aberrations, without further efficiency loss due to additional reflections or magnification. The line densities, detector size, pixel size, etc., of the detector for this instrument are dependent on the drift rate of the space platform; a design optimized for an uncorrected 4-arcsec drift is presented.

Hurwitz, Mark↗

Synthetic-Aperture Coherent Imaging From A Circular Path

Imaging algorithms based on exact point-target responses. Developed for use in reconstructing image of target from data gathered by radar, sonar, or other transmitting/receiving coherent-signal sensory apparatus following circular observation path around target. Potential applications include: Wide-beam synthetic-aperture radar (SAR) from aboard spacecraft in circular orbit around target planet; SAR from aboard airplane flying circular course at constant elevation around central ground point, toward which spotlight radar beam pointed; Ultrasonic reflection tomography in medical setting, using one transducer moving in circle around patient or else multiple transducers at fixed positions on circle around patient; and Sonar imaging of sea floor to high resolution, without need for large sensory apparatus.

Jin, Michael Y.↗

Quantum cascade light emitting diodes based on type-2 quantum wells

The authors have demonstrated room-temperature CW operation of type-2 quantum cascade (QC) light emitting diodes at 4.2 (micro)m using InAs/InGaSb/InAlSb type-2 quantum wells. The type-2 QC configuration utilizes sequential multiple photon emissions in a staircase of coupled type-2 quantum wells. The device was grown by molecular beam epitaxy on a p-type GaSb substrate and was compared of 20 periods of active regions separated by digitally graded quantum well injection regions. The maximum average output power is about 250 (micro)W at 80 K, and 140 (micro)W at 300 K at a repetition rate of 1 kHz with a duty cycle of 50%.

Light Emitting Diodes↗

Twin Telescope Tests: Assessing Station Oriented Systematic Errors

Each of NASA’s three Deep Space Network sites has multiple large antennas capable of acquiring VLBI data. The long range plan is to have four 34-meter beam waveguide antennas at each site. At present Goldstone has three, Canberra has three, and Madrid has two with two more under construction. These antennas offer the opportunity to do connected element interferometry (CEI) over the few hundred meter baselines within each complex. Given that all antennas within a site are of nominally the same structural design, are run off the same clock, observe through almost the same atmosphere, and are subject to almost the same geophysics, doing CEI experiments is an excellent way to probe the limits of VLBI accuracy and expose station-specific systematic errors. This paper will report the results of just such tests which achieved about 0.2 mm baseline precision per pass. Some stations exhibit more than 1 mm systematics. Based on this data we will discuss the implications for whether the IAG’s goal of 1 mm station stability in VLBI geodesy is possible for large antennas.

Jacobs, Christopher↗

Super-strong magnetic field-dominated ion beam dynamics in focusing plasma devices

High energy density physics is the field of physics dedicated to the study of matter and plasmas in extreme conditions of temperature, densities and pressures. It encompasses multiple disciplines such as material science, planetary science, laboratory and astrophysical plasma science. For the latter, high energy density states can be accompanied by extreme radiation environments and super-strong magnetic fields. The creation of high energy density states in the laboratory consists in concentrating/depositing large amounts of energy in a reduced mass, typically solid material sample or dense plasma, over a time shorter than the typical timescales of heat conduction and hydrodynamic expansion. Laser-generated, high current–density ion beams constitute an important tool for the creation of high energy density states in the laboratory. Focusing plasma devices, such as cone-targets are necessary in order to focus and direct these intense beams towards the heating sample or dense plasma, while protecting the proton generation foil from the harsh environments typical of an integrated high-power laser experiment. A full understanding of the ion beam dynamics in focusing devices is therefore necessary in order to properly design and interpret the numerous experiments in the field. In this work, we report a detailed investigation of large-scale, kilojoule-class laser-generated ion beam dynamics in focusing devices and we demonstrate that high-brilliance ion beams compress magnetic fields to amplitudes exceeding tens of kilo-Tesla, which in turn play a dominant role in the focusing process, resulting either in a worsening or enhancement of focusing capabilities depending on the target geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ANNIE: the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a Gadolinium-loaded water Cherenkov detector placed in the Booster Neutrino Beam (BNB) at the Fermi National Accelerator Laboratory, USA. The primary physics goal of ANNIE is to perform neutrino cross-section measurements that will constrain systematic uncertainties in the next generation of long-baseline neutrino experiments. The first measurement will be the multiplicity of final-state neutrons from neutrino-nucleus interactions in water. Alongside these measurements, ANNIE has achieved the first ever deployments of two novel detector technologies in a neutrino beam: Large Area Picosecond Photodetectors (LAPPDs) and Water-based Liquid Scintillator (WbLS). LAPPDs are micro-channel-plate-based devices that provide timing resolution of ~100 picoseconds and sub-centimeter spatial resolution. WbLS combines the low attenuation and Cherenkov production of pure water with the high light-yield and low detection threshold of liquid scintillator. This talk will discuss the status of ANNIE's physics and R&D measurements.

43 PARTICLE ACCELERATORS↗

Dissipative Reactions with Intermediate-Energy Beams: A Novel Approach to Populate Complex-Structure States in Rare Isotopes

A novel pathway for the formation of multiparticle-multihole excited states in rare isotopes is reported from highly energy- and momentum-dissipative inelastic-scattering events measured in reactions of an intermediate-energy beam of 38 Ca on a Be target. The negative-parity, complex-structure final states in 38 Ca are observed following the in-beam γ-ray spectroscopy of events in the 9 Be( 38 Ca, 38 Ca + γ)X reaction in which the scattered projectile loses longitudinal momentum of order Δp || = 700 MeV/c. Here, the characteristics of the observed final states are discussed and found to be consistent with the formation of excited states involving the rearrangement of multiple nucleons in a single, highly energetic projectile-target collision. Unlike the far-less-dissipative, surface-grazing reactions usually exploited for the in-beam γ-ray spectroscopy of rare isotopes, these more energetic collisions appear to offer a practical pathway to nuclear-structure studies of more complex multiparticle configurations in rare isotopes—final states conventionally thought to be out of reach with high-luminosity fast-beam-induced reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intracavity Rayleigh/Mie Scattering for Multipoint, Two-Component Velocity Measurement

A simultaneous multi-point two-component Doppler velocimeter is described. The system uses two optical cavities: a Fabry-Perot etalon and an optical cavity for collecting and re-circulating the Rayleigh/Mie scattered light that is collected from the measurement volume in two parallel, but opposite directions. Single-pulse measurements of two orthogonal components of the velocity vector in a supersonic free jet were performed to demonstrate the technique. The re-circulation of the light rejected by the interferometer input mirror also increased the signal intensity by a factor of 3.5. 2005 Optical Society of America Interferometric Rayleigh scattering has previously been used for single-point velocity measurements in unseeded gas flow. However, this past work has generally been limited to probing with continuous-wave lasers resulting in time-averaged measurements of velocity. Multiple velocity components have been measured simultaneously by separate instruments.1,2 It has also been demonstrated that two orthogonal velocity components can be measured simultaneously at one point using one interferometer by reflecting back the probing laser beam, although this approach results in directional ambiguity of the flow velocity vector.3 This measurement ambiguity was removed by prior knowledge of the approximate magnitude and sign of the velocity components. Furthermore, it was shown that multiple points could be measured simultaneously with a Rayleigh scattering interferometric approach, but only one component of velocity was measured.4 Another method of performing multiple component velocity measurements with Rayleigh scattering uses a pair of cameras to image the flow, one of which views the flow through an iodine gas filter. This iodine-filter technique has the advantage of allowing high-resolution velocity imaging, but it generally has a lower dynamic range.

Bivolaru, Daniel↗