Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “movement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Biomechanics of the Treadmill Locomotion on the International Space Station

Exercise prescriptions completed by International Space Station (ISS) crewmembers are typically based upon evidence obtained during ground-based investigations, with the assumption that the results of long-term training in weightlessness will be similar to that attained in normal gravity. Coupled with this supposition are the assumptions that exercise motions and external loading are also similar between gravitational environments. Normal control of locomotion is dependent upon learning patterns of muscular activation and requires continual monitoring of internal and external sensory input [1]. Internal sensory input includes signals that may be dependent on or independent of gravity. Bernstein hypothesized that movement strategy planning and execution must include the consideration of segmental weights and inertia [2]. Studies of arm movements in microgravity showed that individuals tend to make errors but that compensation strategies result in adaptations, suggesting that control mechanisms must include peripheral information [3-5]. To date, however, there have been no studies examining a gross motor activity such as running in weightlessness other than using microgravity analogs [6-8]. The objective of this evaluation was to collect biomechanical data from crewmembers during treadmill exercise before and during flight. The goal was to determine locomotive biomechanics similarities and differences between normal and weightless environments. The data will be used to optimize future exercise prescriptions. This project addresses the Critical Path Roadmap risks 1 (Accelerated Bone Loss and Fracture Risk) and 11 (Reduced Muscle Mass, Strength, and Endurance). Data were collected from 7 crewmembers before flight and during their ISS missions. Before launch, crewmembers performed a single data collection session at the NASA Johnson Space Center. Three-dimensional motion capture data were collected for 30 s at speeds ranging from 1.5 to 9.5 mph in 0.5 mph increments with a 12-camera system. During flight, each crewmember completed up to 6 data collection sessions spread across their missions, performing their normal exercise prescription for the test day, resulting in varying data collection protocols between sessions. Motion data were collected by a single HD video camera positioned to view the crewmembers' left side, and tape markers were placed on their feet, legs, and neck on specific landmarks. Before data collection, the crewmembers calibrated the video camera. Video data were collected during the entire exercise session at 30 Hz. Kinematic data were used to determine left leg hip, knee, and ankle range of motion and contact time, flight time, and stride time for each stride. 129 trials in weightlessness were analyzed. Mean time-normalized strides were found for each trial, and cross-correlation procedures were used to examine the strength and direction of relationships between segment movement pattern timing in each gravitational condition. Cross-correlation analyses between gravitational conditions revealed highly consistent movement patterns at each joint. Peak correlation coefficients occurred at 0% phase, indicating there were no lags in movement timing. Joint ranges of motion were similar between gravitational conditions, with some slight differences between subjects. Motion patterns in weightlessness were highly consistent at a given speed with those occurring in 1G, indicating that despite differing sensory input, subjects maintain running kinematics. The data suggest that individuals are capable of compensating for loss of limb weight when creating movement strategies. These results have important implications for creating training programs for use in weightlessness as practitioners can have greater confidence in running motions transferring across gravitational environments. Furthermore, these results have implications for use by researchers investigating motor control mechanisms and investigating hypotheses related to movement strategies when using sensory input that is dependent upon gravity.

DeWitt, John↗

Variable Vector Countermeasure Suit (V2Suit) for Space Habitation and Exploration

The "Variable Vector Countermeasure Suit (V2Suit) for Space Habitation and Exploration" is a visionary system concept that will revolutionize space missions by providing a platform for integrating sensors and actuators with daily astronaut intravehicular activities to improve human health and performance. The V2Suit uses control moment gyroscopes (CMGs) within a miniaturized module placed on body segments to provide a "viscous resistance" during movements and a countermeasure to the sensorimotor and musculoskeletal adaptation performance decrements that manifest themselves while living and working in microgravity and during gravitational transitions during long-duration spaceflight, including post-flight recovery and rehabilitation. Through an integrated design, system initialization, and control systems approach the V2Suit is capable of generating this "viscous resistance" along an arbitrarily specified direction of "down." When movements are made, for example, parallel to that "down" direction a resistance is applied, and when the movement is perpendicular to that direction no resistance is applied. The V2Suit proposes to be a countermeasure to this spaceflight-related adaptation and de-conditioning and the unique sensorimotor characteristics associated with living and working in 0-G, which are critical for future long-duration space missions.This NIAC Phase I project focused on detailing several aspects of the V2Suit concept, including human-system integration, system architecture, computer aided design (CAD) modeling, and closed-loop simulation and analysis. In addition, early-stage breadboard prototyping of several aspects of the V2Suit system modules enabled characterization of expected performance and identified areas for further research and development to enable operational implementation of the V2Suit. In particular, potential challenges with integration of commercial-off-the-shelf components were identified. The key enabler for operational use and adoption of the V2Suit is a low-profile body worn form factor that does not interfere with normal, everyday movements and interfaces adequately with the body as to provide the generated gyroscopic torque for the perceptions of movement with a "viscous resistance." These aspects were investigated through mockups using a life-size mannequin, and through body attachment mechanisms on the breadboard prototype. Through the evaluation and investigation of commercially-available components, as well as an identification of desirable form factors, CAD models of the V2Suit modules were developed. These models included all of the required elements and spin motors, flywheel masses, gimbal motors, slip rings, inertial measurement units, motor controllers, and the required mounting brackets/hardware and cabling. The configuration and orientation of the control moment gyroscopes (CMGs) was specified according to results from the modeling, simulation and analysis. Two revisions of the CAD model were investigated through closed-loop simulation of the CMGs, and their ability to generate a resultant reaction force during movement and null undesirable torques due to changes in the direction of the angular momentum vector as a result of the normal body movements.

space missions↗

Design and Development of a Robotic Exoskeleton Device for use in Glove Boxes - 20374

Glovebox operators in nuclear facilities often operate under radioactive environment and typically perform monotonous, dull and repetitive work. This can result in muscle fatigue leading to increased levels of accidents. Current research work aims in assisting the glovebox operators by designing a novel upper limb exoskeleton device to reduce injuries and increase worker efficiency. Almost none of the commercially available hand and upper body exoskeletons are directly suitable for use in gloveboxes. This explains the novelty of the present work in developing a wearable powered robotic exoskeleton device. The device consists of electronics, motors and spring systems mounted on adjustable plates and is supported by a stationary frame behind the worker. The device is intended to be portable and adjustable according to the operator height. The elbow has a flexion movement assisted with motor control by way of a Bowden cable system. The system is floated on a spring and pulley combination that allows for extra safety and smoothness of operation. The end points are fixed near the pivot points to help minimize unwanted movement/torque. The extension movement of the upper and lower arm are assisted by gravity and a counter spring. The shoulder and upper arm movement are held in a neutral position with a spring system for counter balance allowing small movements within the glovebox. This initial concept considers only the vertical movement of the arm. The abduction and adduction movement will not be assisted or impeded by the over shoulder plate or at the forearm plate allowing for full range of motion. Several glovebox aspects such as the level of task assistance, ergonomic design, minimum hindrance in dexterity/operator movements and tear resistance for hazardous safety reasons will be considered in the design of the exoskeleton. Computer models will be simulated to test the load levels and stress conditions on the exoskeleton to enhance the designs. The exoskeleton focusses on major muscular involvement reduction through weight offset and active assistance with minimal parts and hence the device is derived with several joint links and contains both passive and active joints. The paper details the various stages in the design development and prototype testing of the exoskeleton device. Upon successful prototype device development, human testing will be conducted in a replica of the SRS-235F hot cell facility constructed at FIU-ARC. The final stage of the project will be potential testing/deployment of the exoskeleton device in one of the glovebox facilities in Savannah River Nuclear Waste site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Molecular Dynamics Studies of Proton Transport in Hydrogenase and Hydrogenase Mimics

Protons are used throughout the biological world for a number of functions, from charge balance to energy carriers. Metalloenzymes use protons as energy carriers and control proton movement both temporally and spatially. Despite the interest and need for controlled proton movement in other systems, the scientific community has not been able to develop extensive general rules for developing synthetic proton pathways. In part this is due to the challenging nature of studying these large and complex molecules experimentally, although experiments have gleaned extensive critical insight. While computational methods are also challenging because of the large size of the molecules, they have been critical in advancing our knowledge of proton movement through pathways, but even further, they have advanced our knowledge in how protonation and proton movement is correlated with large and small scale molecular motions and electron movement. These studies often complement experimental studies but provide insight and depth simply not possible in many cases in the absence of theory. In this chapter, we will discuss advances and methods used in understanding proton movement in hydrogenases.

Electron Transport↗

Interpreting the spatial distribution of soil properties with a physically-based distributed hydrological model

Digital soil maps are commonly data-driven as the development of physically-based models for soil mapping is difficult due to the complexity of soils. However, physically-based hydrologic models have been successful in simulating water dynamics. Since water movement is a major driver of pedogenesis, the physical rules that govern water movement might help explain and predict the spatial variation of soil properties. Here, we demonstrate the novel use of a physically-based, distributed hydrologic model to inform the spatial distribution of soil properties. The Distributed Hydrology Soil Vegetation Model (DHSVM) was utilized to simulate soil moisture content (SM) and water table depth (WTD) in two hillslope catchments under pasture and forest management wherein hydrologic model outputs were then compared with soil properties measured in situ. SM sensors and wells were installed in both catchments to validate simulations of soil water movement via Nash-Sutcliffe Efficiency (E). In-situ observations were made at 87 sites within both catchments to study the connection between simulated water movement (SM and WTD) and observed soil properties, namely the depth and thickness of the argillic (Bt), fragic (Btx), and C horizons, and the depth of redoximorphic features. The simulated time series of SM and WTD were also clustered per season using Dynamic Time Warping (DTW), which identified similarity among time series at varying timescales. Model validation suggested that simulations of surficial SM (0–20 cm) were reasonable (E = 0.45), however, simulated subsurface SM (45–60 cm) and WTD were not sufficiently accurate. The thickness of Btx horizons were spatially grouped into different populations by SM clusters from every season except spring. For the other properties, only SM dynamics of specific seasons grouped into significantly different populations, suggesting that the explanatory power of simulated water movement varies seasonally and was greater during winter. Here, we show clusters of simulated SM separated soil properties into statistically different populations, showing that hydrologic models could inform areas that followed different water dynamics related to pedogenic trajectories and related biogeochemical processes not necessarily simulated by the model. As such, physically-based modeling of water dynamics can, therefore, inform and advance digital soil mapping by linking water movement patterns stemming from hydrologic model outputs to spatial patterns of soil properties and pedogenesis.

54 ENVIRONMENTAL SCIENCES↗

Quantification of Organ Motion During Chemoradiotherapy of Rectal Cancer Using Cone-Beam Computed Tomography

Purpose: There has been no previously published data related to the quantification of rectal motion using cone-beam computed tomography (CBCT) during standard conformal long-course chemoradiotherapy. The purpose of the present study was to quantify the interfractional changes in rectal movement and dimensions and rectal and bladder volume using CBCT and to quantify the bony anatomy displacements to calculate the margins required to account for systematic ({Sigma}) and random ({sigma}) setup errors. Methods and Materials: CBCT images were acquired from 16 patients on the first 3 days of treatment and weekly thereafter. The rectum and bladder were outlined on all CBCT images. The interfraction movement was measured using fixed bony landmarks as references to define the rectal location (upper, mid, and low), The maximal rectal diameter at the three rectal locations was also measured. The bony anatomy displacements were quantified, allowing the calculation of systematic ({Sigma}) and random ({sigma}) setup errors. Results: A total of 123 CBCT data sets were analyzed. Analysis of variance for standard deviation from planning scans showed that rectal anterior and lateral wall movement differed significantly by rectal location. Anterior and lateral rectal wall movements were larger in the mid and upper rectum compared with the low rectum. The posterior rectal wall movement did not change significantly with the rectal location. The rectal diameter changed more in the mid and upper than in the low rectum. No consistent relationship was found between the rectal and bladder volume and time, nor was a significant relationship found between the rectal volume and bladder volume. Conclusions: In the present study, the anterior and lateral rectal movement and rectal diameter were found to change most in the upper rectum, followed by the mid rectum, with the smallest changes seen in the low rectum. Asymmetric margins are warranted to ensure phase 2 coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Esophageal Tumor Motion on Cine-Magnetic Resonance Imaging

Purpose: To quantify the movement of esophageal tumors noninvasively on cine-magnetic resonance imaging (MRI) by use of a semiautomatic method to visualize tumor movement directly throughout multiple breathing cycles. Methods and Materials: Thirty-six patients with esophageal tumors underwent MRI. Tumors were located in the upper (8), middle (7), and lower (21) esophagus. Cine-MR images were collected in the coronal and sagittal plane during 60 seconds at a rate of 2 Hz. An adaptive correlation filter was used to automatically track a previously marked reference point. Tumor movement was measured in the craniocaudal (CC), left–right (LR), and anteroposterior (AP) directions and its relationship along the longitudinal axis of the esophagus was investigated. Results: Tumor registration within the individual images was typically done at a millisecond time scale. The mean (SD) peak-to-peak displacements in the CC, AP, and LR directions were 13.3 (5.2) mm, 4.9 (2.5) mm, and 2.7 (1.2) mm, respectively. The bandwidth to cover 95% of excursions from the mean position (c95) was also calculated to exclude outliers caused by sporadic movements. The mean (SD) c95 values were 10.1 (3.8) mm, 3.7 (1.9) mm, and 2.0 (0.9) mm in the CC, AP, and LR dimensions. The end-exhale phase provided a stable position in the respiratory cycle, compared with more variety in the end-inhale phase. Furthermore, lower tumors showed more movement than did higher tumors in the CC and AP directions. Conclusions: Intrafraction tumor movement was highly variable between patients. Tumor position proved the most stable during the respiratory cycle in the end-exhale phase. A better understanding of tumor motion makes it possible to individualize radiation delivery strategies accordingly. Cine-MRI is a successful noninvasive modality to analyze motion for this purpose in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intracellular imaging of targeted proteins labeled with quantum dots

We developed a new method for imaging the movement of targeted proteins in living cancer cells with photostable and bright quantum dots (QDs). QDs were conjugated with various molecules and proteins, such as phalloidin, anti-tubulin antibody and kinesin. These bioconjugated QDs were mixed with a transfection reagent and successfully internalized into living cells. The movements of individual QDs were tracked for long periods of time. Phalloidin conjugated QDs bound to actin filaments and showed almost no movement. In contrast, anti-tubulin antibody conjugated QDs bound to microtubules and revealed dynamic movement of microtubules. Kinesin showed an interesting behavior whereby kinesin came to be almost paused briefly for a few seconds and then moved once again. This is in direct contrast to the smoothly continuous movement of kinesin in an in vitro assay. The maximum velocity of kinesin in cells was faster than that in the in vitro assay. These results suggest that intracellular movement of kinesin is different from that in the in vitro assay. This newly described method will be a powerful tool for investigating the functions of proteins in living cells.

60 APPLIED LIFE SCIENCES↗

Mechanisms of Semiconducting 2H to Metallic 1T Phase Transition in Two-dimensional MoS 2 Nanosheets

In the present work, phase transition mechanisms from semiconducting 2H phase to metallic 1T phase in MoS 2 nanosheets were studied using density functional theory (DFT) method. Various 2H→1T phase transition mechanisms that consist of nucleation and propagation steps, which simulated by collective rotational and rotational/translational movements, single atom translational movement, as well as the gliding movement of one row for sulfur (S) atoms, on both the basal plane and Mo- and S-edges with different S coverages were investigated. On the perfect basal plane, the 1T phase nucleation is unlikely due to the extremely high barrier of 2.25 eV/atom. Whereas the presence of defective S vacancies on the basal plane dramatically facilitate the 1T phase nucleation and propagation around the defective sites by the collective rotational movement of three S atoms. On the 2H phase basal plane with two S vacancies, the kinetic barriers for the 1T phase nucleation are as low as of 0.66~0.77 eV/atom. Like the promoting effect of S vacancies on the phase transition over the basal plane, DFT results suggest that the S coverage on the Mo- and S-edges will affect the 1T phase nucleation and propagation. The 1T phase nucleation starting with the translational movement of single S atom on the bare Mo-edge and the gliding movement of an entire row of S atoms on the S-edge with 50%S coverage are kinetically favorable. While the 1T phase formation at the Mo-edge with 50%S coverage and the S-edge with 100% S coverage are unlikely. The present work not only confirms the important role of S vacancies/coverages in the 2H-1T phase transition, but also provides new insight into how and where the 2H-1T phase transition occurs at the atomic level, which also sheds light on the general phase transition mechanism for two-dimensional transition metal dichalcogenide materials. The work was financially supported by the National Natural Science Foundation of China (No. 21476012, 21571012, and 91534201). Q. Jin appreciates the joint Ph.D. scholarship support from the China Scholarship Council. The computing time was granted by a scientific theme user proposal in the William R. Wiley Environmental Molecular Sciences Laboratory (EMSL), which is a U.S. Department of Energy national scientific user facility located at PNNL in Richland, Washington. D. Mei is supported by the US Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences.

Molybdenum disulfide, phase transition, sulfur vac↗

Diabatic error and propagation of Majorana zero modes in interacting quantum dots systems

Motivated by recent experimental progress in realizing Majorana zero modes (MZMs) using quantum dot systems, we investigate the diabatic errors associated with the movement of those MZMs. The movement is achieved by tuning time-dependent gate potentials applied to individual quantum dots, effectively creating a moving potential wall. To probe the optimized movement of MZMs, we calculate the experimentally accessible time-dependent fidelity and local density-of-states using many-body time-dependent numerical methods. Furthermore, our analysis reveals that an optimal potential wall height is crucial to preserve the well-localized nature of the MZM during its movement. Moreover, we analyze diabatic errors in realistic quantum-dot systems, incorporating the effects of repulsive Coulomb interactions and disorder in both hopping and pairing terms. Additionally, we provide a comparative study of diabatic errors arising from the simultaneous versus sequential tuning of multiple gates during the MZMs movement. Finally, we estimate the timescale required for MZM transfer in a six-quantum-dot system, demonstrating that MZM movement is feasible and can be completed well within the qubit's operational lifetime in practical quantum-dot setups.

Density of states↗

From deep TLS validation to ensembles of atomic models built from elemental motions

Procedures are described for extracting the vibration and libration parameters corresponding to a given set of TLS matrices and their simultaneous validation. Knowledge of these parameters allows the generation of structural ensembles corresponding to these matrices. The translation–libration–screw model first introduced by Cruickshank, Schomaker and Trueblood describes the concerted motions of atomic groups. Using TLS models can improve the agreement between calculated and experimental diffraction data. Because the T, L and S matrices describe a combination of atomic vibrations and librations, TLS models can also potentially shed light on molecular mechanisms involving correlated motions. However, this use of TLS models in mechanistic studies is hampered by the difficulties in translating the results of refinement into molecular movement or a structural ensemble. To convert the matrices into a constituent molecular movement, the matrix elements must satisfy several conditions. Refining the T, L and S matrix elements as independent parameters without taking these conditions into account may result in matrices that do not represent concerted molecular movements. Here, a mathematical framework and the computational tools to analyze TLS matrices, resulting in either explicit decomposition into descriptions of the underlying motions or a report of broken conditions, are described. The description of valid underlying motions can then be output as a structural ensemble. All methods are implemented as part of the PHENIX project.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-45: Design and Study of An In-House Respiratory Gating Phantom Platform for Gated Radiotherapy

Purpose: The main purpose of this work was to develop an in-house low cost respiratory motion phantom platform for testing the accuracy of the gated radiotherapy system and analyze the dosimetric difference during gated radiotherapy. Methods: An in-house respiratory motion platform(RMP) was designed and constructed for testing the targeting accuracy of respiratory tracking system. The RMP consist of acrylic Chest Wall Platform, 2 DC motors, 4 IR sensors, speed controller circuit, 2 LED and 2 moving rods inside the RMP. The velocity of the movement can be varied from 0 to 30 cycles per minute. The platform mounted to a base using precision linear bearings. The base and platform are made of clear, 15mm thick polycarbonate plastic and the linear ball bearings are oriented to restrict the platform to a movement of approximately 50mm up and down with very little friction. Results: The targeting accuracy of the respiratory tracking system was evaluated using phantom with and without respiratory movement with varied amplitude. We have found the 5% dose difference to the PTV during the movement in comparison with stable PTV. The RMP can perform sinusoidal motion in 1D with fixed peak to peak motion of 5 to 50mm and cycle interval from 2 to 6 seconds. The RMP was designed to be able to simulate the gross anatomical anterior posterior motion attributable to respiration-induced motion of the thoracic region. Conclusion: The unique RMP simulates breathing providing the means to create a comprehensive program for commissioning, training, quality assurance and dose verification of gated radiotherapy treatments. Create the anterior/posterior movement of a target over a 5 to 50 mm distance to replicate tumor movement. The targeting error of the respiratory tracking system is less than 1.0 mm which shows suitable for clinical treatment with highly performance.

60 APPLIED LIFE SCIENCES↗

SU-E-J-211: Design and Study of In-House Software Based Respiratory Motion Monitoring, Controlling and Breath-Hold Device for Gated Radiotherapy

Purpose: The purpose of this present work was to fabricate an in-house software based respiratory monitoring, controlling and breath-hold device using computer software programme which guides the patient to have uniform breath hold in response to request during the gated radiotherapy. Methods: The respiratory controlling device consists of a computer, inhouse software, video goggles, a highly sensitive sensor for measurement of distance, mounting systems, a camera, a respiratory signal device, a speaker and a visual indicator. The computer is used to display the respiratory movements of the patient with digital as well as analogue respiration indicators during the respiration cycle, to control, breath-hold and analyze the respiratory movement using indigenously developed software. Results: Studies were conducted with anthropomophic phantoms by simulating the respiratory motion on phantoms and recording the respective movements using the respiratory monitoring device. The results show good agreement between the simulated and measured movements. Further studies were conducted for 60 cancer patients with several types of cancers in the thoracic region. The respiratory movement cycles for each fraction of radiotherapy treatment were recorded and compared. Alarm indications are provided in the system to indicate when the patient breathing movement exceeds the threshold level. This will help the patient to maintain uniform breath hold during the radiotherapy treatment. Our preliminary clinical test results indicate that our device is highly reliable and able to maintain the uniform respiratory motion and breathe hold during the entire course of gated radiotherapy treatment. Conclusion: An indigenous respiratory monitoring device to guide the patient to have uniform breath hold device was fabricated. The alarm feature and the visual waveform indicator in the system guide the patient to have normal respiration. The signal from the device can be connected to the radiation unit in near future to carry out the gated radiotherapy treatment.

60 APPLIED LIFE SCIENCES↗

NGEE Arctic Integrated Modeling (IM2): Improved subgrid hillslope hydrologic connectivity

This data product represents the integration of new code capability for arctic tundra hillslope hydrologic processes into the Energy Exascale Earth System Model (E3SM), through the E3SM Land Model (ELM) component. This code integration is the result of collaborative effort between the NGEE Arctic project and the E3SM project. The current ELM represents water movement primarily through vertical processes, such as precipitation, canopy interception, evaporation, infiltration, and soil water movement. Lateral water movement—such as surface runoff, subsurface flow, and river transport—plays a significant role in the hydrological cycle, especially in regions with varied topography. While E3SM includes a runoff routing component representing water transport in the river network, the lateral transport of water at the subgrid scale within the land model has previously not been taken into account. With the recent development of topographic units within the ELM subgrid data structure, there is an opportunity to simulate hillslope hydrologic connectivity by introducing water transport along topographic gradients. We expect that more realistic representation of hillslope hydrologic processes will lead to improved predictions of both soil water content and river network flows. Lateral transport of water at and near the surface is represented as a sub-grid process in this new code development. Water is tracked as it moves from higher to lower elevations within a gridcell. This capability uses the nested hierarchical sub-grid scheme within ELM to connect water fluxes from sub-grid elements with higher elevation to those with lower elevation. This data record consists of a single document (pdf format) that describes the theoretical basis for the hillslope hydrology processes added to ELM, and describes the modifications made to the ELM code. The Methods section of this metadata record includes a link to the public E3SM code repository where the exact code modifications as integrated in E3SM can be accessed. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

Thornton, Peter E [ORNL] (ORCID:0000000247595158)↗

Source Physics Experiment: Rock Valley Interferometric Synthetic Aperture RADAR Earthquake Detection Study

Seismic signals from 1993 show a series of magnitude (Mw) 3.7 or less seismic events in Rock Valley on the Nevada National Security Site (NNSS). Historic synthetic aperture radar images of that location were found that could provide interferometric synthetic aperture radar (InSAR) measures of the ground height during 1993. Given this historic SAR imagery, we explore answering the question if ground movement from the 1993 Rock Valley earthquake activity could be sensed by remote sensing means. Finding earthquake surface movement would assist in locating the Rock Valley fault and the 1993 earthquake hypocenter where the Source Physics Experiment Phase III series of experiments will be conducted. In this report, we show that InSAR can sense very small height differences, and for the European Radar Satellite-1 InSAR collections during 1992 and 1993 over Rock Valley earth surface movements were measured with 8 mm uplift and 12.5 mm subsidence over isolated areas. One of these earth movement areas coincides with an InSAR image pair coherence drop between March 5, 1993 and June 18, 1993. The coherence drop is over an approximately 13 square km area south southeast of Skull Mountain centered at 36° 43' 30" N latitude and 116° 05' 00" W longitude. Measured small surface movement and a loss of InSAR coherence may be caused by the series of earthquakes. The location of these InSAR detections may also coincide with water drainage or erosion displacement. There are no records to disambiguate the earthquake and erosion earth surface motion possibilities. Therefore, the InSAR findings of earth surface movement by InSAR are inconclusive.

58 GEOSCIENCES↗

Active head rotations and eye-head coordination

It is pointed out that head movements play an important role in gaze. The interaction between eye and head movements involves both their shared role in directing gaze and the compensatory vestibular ocular reflex. The dynamics of head trajectories are discussed, taking into account the use of parameterization to obtain the peak velocity, peak accelerations, the times of these extrema, and the duration of the movement. Attention is given to the main sequence, neck muscle EMG and details of the head-movement trajectory, types of head model accelerations, the latency of eye and head movement in coordinated gaze, gaze latency as a function of various factors, and coordinated gaze types. Clinical examples of gaze-plane analysis are considered along with the instantaneous change of compensatory eye movement (CEM) gain, and aspects of variability.

Zangemeister, W. H.↗

Sensory and motor properties of the cerebellar uvula and modulus

The uvula and nodulus (vermal lobules 9 and 10) of the vestibulocerebellum are implicated by behavioral evidence in the control of eye and head movements and in the production of motion sickness. The uvula and nodulus could play a role in these functions through known output pathways. Purkinje cells in both structures project via the fastigial and vestibular nuceli to the ventral horn of the cervical spin cord, to oculomotor neurons, and to the emetic region of the reticular formation (ablation of which abolishes susceptability to motion sickness). Uvula and nodulus Purkinje cells will be analyzed in cats trained to make controlled head movements. The activity of these neurons is expected to modulate well during head and/or eye movements because the uvula and nodulus receive heavy projections from sources of visual, vestibular and neck proprioceptive information. How neuron activity contributes to movement and how different sensory inputs converge to influence this contribution may be determined by characterizing movement related properties of these neurons. A population of neurons that modulates powerfully to the conflict between different head movement signals that can cause motion sickness may be identified.

Robinson, F. R.↗

Observations, theoretical ideas and modeling of turbulent flows: Past, present and future

Turbulence was analyzed in a historical context featuring the interactions between observations, theoretical ideas, and modeling within three successive movements. These are identified as predominantly statistical, structural and deterministic. The statistical movement is criticized for its failure to deal with the structural elements observed in turbulent flows. The structural movement is criticized for its failure to embody observed structural elements within a formal theory. The deterministic movement is described as having the potential of overcoming these deficiencies by allowing structural elements to exhibit chaotic behavior that is nevertheless embodied within a theory. Four major ideas of this movement are described: bifurcation theory, strange attractors, fractals, and the renormalization group. A framework for the future study of turbulent flows is proposed, based on the premises of the deterministic movement.

Chapman, G. T.↗