Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Buckling tests of three 4.6 meter diameter aluminum honeycomb sandwich conical shells loaded under external pressure

Three aluminum honeycomb sandwich conical shells with a 120 apex angle and a 4.6-m (15.0-ft) base diameter were loaded to failure by a uniform external pressure. The cones differed from one another only in the thickness of their respective face sheets. Test specimen details, test procedure, and test results are discussed. Both buckling and prebuckling data are compared with appropriate theoretical predictions, and good agreement was obtained between test and theory. Extensive imperfection measurements were made and reported on the three cones in the as fabricated condition.

Anderson, J. K.↗

A description and some measured acoustic characteristics of the Langley 220 cubic meter reverberation chamber

An initial acoustic calibration was performed for the NASA Langley Research Center reverberation chamber located on the aircraft Noise Reduction Laboratory. The physical characteristics of the chamber and measured data for the ambient acoustic levels, reverberation times, reflection coefficients, the spatial uniformity of acoustic energy as measured in the 1/3-octave bands from 40 Hz to 10 KHz and acoustic power levels of a standard source are described. Measured power levels compared very well with those published for the ILG standard source. The measured data indicate that for broadband noise fields, the reverberation room has acceptable acoustic performance in the frequency range from 100 Hz to 8 KHz.

Mueller, A. W.↗

Pressure-viscosity measurements for several lubricants to 550 meganewtons per square meter /80,000 PSI/ and 149 C /300 F/

The viscosities of a number of liquid lubricants and lubricant formulations, determined as function of pressure, temperature, and shear stress by means of a high-pressure capillary viscometer, are reviewed. Where possible, these results are compared with those obtained by other techniques (optical elastohydrodynamics, oscillating crystal, and low shear capillary viscometry).

Jones, W. R., Jr.↗

Meter-wavelength VLBI. I - Cassiopeia A

Very-long-baseline interferometric observations of the supernova remnant Cassiopeia A, at 74 MHz with a 12,000-wavelength baseline and at 111 MHz with a 18,500-wavelength baseline, are reported. The fringe amplitudes are strongly varying on a time scale of about 15 to 30 minutes, which is attributed to much the same complex structure as that observed at higher frequencies, plus one other compact source. Due to the poor (u, nu)-plane coverage, the location of the extra source can not be isolated unambiguously, but possibilities are suggested. The source must lie outside the supernova remnant shell, possibly associated with a concentration of emission north of the shell, or lying outside the gap in the northeastern side of the shell. The flux and spectral index deduced for the compact source depend on the assumed size, with a range of 100 Jy and 500 Jy at 74 MHz. If the source is associated with the supernova explosion, it must have been traveling at least 5000 km/sec.

Hutton, L. K.↗

Airloads near the open port of a one-meter airborne telescope

An infrared telescope is mounted in a cavity in the fuselage of a C-141 airplane. The cavity is sealed off from the rest of the fuselage and can be opened to the outside for viewing. A retractable porous spoiler is installed ahead of the opening to inhibit cavity resonance. The paper presents the mean pressures, pressure fluctuations, spectra, phase, and coherence of the pressures in the cavity and on the fuselage near the cavity, along with pertinent acceleration and torque information for the aircraft structure and telescope. It is shown that a moderate spoiler extension controls resonance in normal flight attitudes and produces a cavity environment with approximately the same turbulence intensity as an attached turbulent boundary layer.

Buell, D. A.↗

Design of a graphite/epoxy metering truss for the Large Space Telescope

This paper presents the design development of a truss-type structure which utilizes graphite/epoxy as the primary material system. A review is given of an on-going NASA sponsored program to develop a structural assembly which is required to have a very high degree of dimensional stability. Methods of material characterization and selection are given along with property data such as strength, stiffness, outgassing and thermal expansion. Finite element (NASTRAN) analysis will be discussed and deflection plots of the lowest mode frequencies will be presented. Proposed full scale tests: static, dynamic, and thermal/vacuum will be described.

Oken, S.↗

Inlet noise on 0.5-meter-diameter NASA QF-1 fan as measured in an unmodified compressor aerodynamic test facility and in an anechoic chamber

Narrowband analysis revealed grossly similar sound pressure level spectra in each facility. Blade passing frequency (BPF) noise and multiple pure tone (MPT) noise were superimposed on a broadband (BB) base noise. From one-third octave bandwidth sound power analyses the BPF noise (harmonics combined), and the MPT noise (harmonics combined, excepting BPF's) agreed between facilities within 1.5 db or less over the range of speeds and flows tested. Detailed noise and aerodynamic performance is also presented.

Gelder, T. F.↗

Structure of atmospheric turbulence in the friction layer below 500 meters

Measurements of wind direction and speed, vertical velocity, and temperature were made from several levels of the 444 m tower near Oklahoma City. Turbulence quantities were calculated from the covariances between observed variables over periods ranging from 5 min to 1 hr. It was found that in some cases parameters such as mean wind speed, shearing stress, and vertical heat flux could be expressed by simple equations for periods of 15 min to 1 hr. Changes in these quantities with time are related to changes in vertical motion and stability. Power spectra were calculated for sequential 15 min, 30 min, and 1 hr periods. The effects of stability, wind speed, and surface roughness on the spectra of longitudinal and lateral velocity were examined, along with the effect of height on the spectrum of vertical velocity. This region was shown to be composed of a lower region in which mechanical turbulence dominates and an upper region dominated by convective turbulence.

Maas, S. J.↗

Meter-wavelength VLBI. III - Pulsars

Observations of pulsars, especially the Crab Nebula pulsar, made in very long baseline interferometry (VLBI) experiments are discussed. Based on a crude 144 MHz visibility curve which is consistent with a Gaussian brightness distribution, the measured visibilities at 196, 111, and 74 MHz were interpreted to yield apparent angular diameters (at half-power) of about 0.03 sec, 0.07 sec, and 0.18 sec, respectively. These sizes scale approximately as wavelength-squared, and the 74 MHz size agrees with recent observations using interplanetary scintillation techniques. The total flux densities lie on the extrapolation from higher frequencies of the pulsing flux densities. Variations in the total flux density up to 25 per cent were observed. A lack of fine structure other than the pulsar in the nebula is indicated by the simple visibility curves. The pulse shapes are similar to single-dish measurements at 196 MHz but reveal a steady, nonpulsing component at 111 MHz. The ratio of pulsing to total power was approximately equal to one-half but varied with time. It was found that four strong, low-dispersion pulsars were only slightly resolved.

Vandenberg, N. R.↗

Differential sound-level meter

Relative difference between sound-levels at two different microphone sites is measured precisely with circuit that continuously monitors gains of two acoustical channels. Difference between two pilot voltages is utilized in regulating loop to force gain of second channel to track gain of first channel.

Zuckerwar, A. J.↗

Solar meter with silicon photocell

Instrument for measuring light falling on given spot uses simple silicon photovoltaic cell as sensing element. It measures all light at location: direct, scattered, reflected, or reradiated. Silicon cell is coated with thick antireflecting layer of silicon monoxide and is enclosed in glass dome. Large heat sink reduces temperature fluctuations. Instrument is accurate within few percentage points over angle of Sun's arc across sky.

Yanow, G.↗

Radio frequency boresight analysis of the low cost 64-meter antenna

Configurations (two) of the reflector-only assemblies, using different width backup cones, are analyzed for RF boresight direction changes and wind distortions. The wider backup cone is best for minimum weight; however, there is an optimum weight which minimizes the RF boresight errors for a wind load that produces the maximum pitching moment of both configurations.

Katow, M. S.↗

Acoustic and aerodynamic performance of a variable-pitch 1.83-meter-(6-ft) diameter 1.20-pressure-ratio fan stage (QF-9)

Far field noise data and related aerodynamic performance are presented for a variable pitch fan stage having characteristics suitable for low noise, STOL engine application. However, no acoustic suppression material was used in the flow passages. The fan was externally driven by an electric motor. Tests were made at several forward thrust rotor blade pitch angles and one for reverse thrust. Fan speed was varied from 60 to 120 percent of takeoff (design) speed, and exhaust nozzles having areas 92 to 105 percent of design were tested. The fan noise level was at a minimum at the design rotor blade pitch angles of 64 deg for takeoff thrust and at 57 deg for approach (50 percent takeoff thrust). Perceived noise along a 152.4-m sideline reached 100.1 PNdb for the takeoff (design) configuration for a stage pressure ratio of 1.17 and thrust of 57,600 N. For reverse thrust the PNL values were 4 to 5 PNdb above the takeoff values at comparable fan speeds.

Glaser, F. W.↗

Acoustic and aerodynamic performance of a 1.5-pressure-ratio, 1.83-meter (6 ft) diameter fan stage for turbofan engines (QF-2)

The fan was externally driven by an electric motor. Design features for low-noise generation included the elimination of inlet guide vanes, long axial spacing between the rotor and stator blade rows, and the selection of blade-vane numbers to achieve duct-mode cutoff. The fan QF-2 results were compared with those of another full-scale fan having essentially identical aerodynamic design except for nozzle geometry and the direction of rotation. The fan QF-2 aerodynamic results were also compared with those obtained from a 50.8 cm rotor-tip-diameter model of the reverse rotation fan QF-2 design. Differences in nozzle geometry other than exit area significantly affected the comparison of the results of the full-scale fans.

Woodward, R. P.↗

Assembly and testing of a 1.8 by 3.7 meter Fresnel lens solar concentrator

A project was initiated to establish a technical data base on line focusing acrylic Fresnel lenses for use in a solar collector system that could generate temperatures in the range of 200 C to 370 C. The effort was originally directed toward electric power generation in the 100 to 10,000 kWe range using a distributed collector approach. However, as the program progressed, it centered on the development of a concentrator/collector subsystem concept that could meet the general requirement of thermal delivery within the 200 C to 370 C range. The expanded list of possible applications includes commercial heating/cooling and industrial process heat as well as electric power generation.

Robertson, J. E.↗

An analytical and experimental investigation of a 1.8 by 3.7 meter Fresnel lens solar concentrator

Line-focusing acrylic Fresnel lenses with application potential in the 200 to 370 C range are being analytically and experimentally evaluated. Investigations previously conducted with a 56 cm wide lens have been extended by the present study to experimentation/analyses with a 1.8 by 3.7 m lens. A measured peak concentration ratio of 64 with 90 percent of the transmitted energy focused into a 5.0 cm width was achieved. A peak concentration of 61 and a 90 percent target width of 4.5 cm were analytically computed. The experimental and analytical lens transmittance was 81 percent and 86 percent, respectively. The lens also was interfaced with a receiver assembly and operated in the collection mode. The collection efficiency ranged from 42 percent at 100 C to 26 percent at 300 C.

Hastings, L. J.↗