Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “magnetization measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Suppression of Heating of Coronal Loops Rooted in Opposite Polarity Sunspot Umbrae

EUV observations of active region (AR) coronae reveal the presence of loops at different temperatures. To understand the mechanisms that result in hotter or cooler loops, we study a typical bipolar AR, near solar disk center, which has moderate overall magnetic twist and at least one fully developed sunspot of each polarity. From AIA 193 and 94 Å images we identify many clearly discernible coronal loops that connect plage or a sunspot of one polarity to an opposite-­polarity plage region. The AIA 94 Å images show dim regions in the umbrae of the spots. To see which coronal loops are rooted in a dim umbral area, we performed a non-linear force‐free field (NLFFF) modeling using photospheric vector magnetic field measurements obtained with the Heliosesmic Magnetic Imager (HMI) onboard SDO. The NLFFF model, validated by comparison of calculated model field lines with observed loops in AIA 193 and 94 Å, specifies the photospheric roots of the model field lines. Some model coronal magnetic field lines arch from the dim umbral area of the positive-polarity sunspot to the dim umbral area of a negative-polarity sunspot. Because these coronal loops are not visible in any of the coronal EUV and X-ray images of the AR, we conclude they are the coolest loops in the AR. This result suggests that the loops connecting opposite polarity umbrae are the least heated because the field in umbrae is so strong that the convective braiding of the field is strongly suppressed.

sunspot↗

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand’s Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the fundamental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scattering provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon's internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (GMn) to unprecedented Q2 using Durand's method, also known as the "ratio" method. Systematic errors are greatly reduced by ext

Datta, Provakar↗

[Measurement of left atrial and ventricular volumes in real-time 3D echocardiography. Validation by nuclear magnetic resonance]

The measurement of the left ventricular ejection fraction is important for the evaluation of cardiomyopathy and depends on the measurement of left ventricular volumes. There are no existing conventional echocardiographic means of measuring the true left atrial and ventricular volumes without mathematical approximations. The aim of this study was to test anew real time 3-dimensional echocardiographic system of calculating left atrial and ventricular volumes in 40 patients after in vitro validation. The volumes of the left atrium and ventricle acquired from real time 3-D echocardiography in the apical view, were calculated in 7 sections parallel to the surface of the probe and compared with atrial (10 patients) and ventricular (30 patients) volumes calculated by nuclear magnetic resonance with the simpson method and with volumes of water in balloons placed in a cistern. Linear regression analysis showed an excellent correlation between the real volume of water in the balloons and volumes given in real time 3-dimensional echocardiography (y = 0.94x + 5.5, r = 0.99, p < 0.001, D = -10 +/- 4.5 ml). A good correlation was observed between real time 3-dimensional echocardiography and nuclear magnetic resonance for the measurement of left atrial and ventricular volumes (y = 0.95x - 10, r = 0.91, p < 0.001, D = -14.8 +/- 19.5 ml and y = 0.87x + 10, r = 0.98, P < 0.001, D = -8.3 +/- 18.7 ml, respectively. The authors conclude that real time three-dimensional echocardiography allows accurate measurement of left heart volumes underlying the clinical potential of this new 3-D method.

Non-NASA Center↗

Detailed report on the measurement of the positive muon anomalous magnetic moment to 0.20 ppm

We present details on a new measurement of the muon magnetic anomaly, a μ =(g μ −2)/2. The result is based on positive muon data taken at Fermilab’s Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses 3.1 GeV/c polarized muons stored in a 7.1-m-radius storage ring with a 1.45 T uniform magnetic field. The value of a μ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using nuclear magnetic resonance. The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure a μ =116592057(25)×10 −11 (0.21 ppm). This is the world’s most precise measurement of this quantity and represents a factor of 2.2 improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield a μ (FNAL)=116592055(24)×10 −11 (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is a μ (exp)=116592059(22)×10 −11 (0.19 ppm).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the local measurement of electric currents and magnetic fields using Thomson scattering in Weibel-unstable plasmas

Here, we demonstrate the capability of the Thomson Scattering (TS) diagnostic to measure locally the microscopic electron and ion currents in counter-streaming plasmas unstable to the Weibel or current-filamentation instability. Synthetic TS spectra are calculated with particle distribution functions obtained from particle-in-cell simulations and used to accurately reproduce the simulated currents. We show that this technique allows accurate local measurements of the magnetic field, thus opening the way for the complete experimental characterization of the growth rate, saturation, and nonlinear dynamics of electromagnetic instabilities in plasmas. We illustrate the application of this diagnostic to experimental TS data, which yields local measurements of the magnetic field in Weibel-unstable plasmas and indicates that the magnetic energy density reaches ~1% of the kinetic energy density of the flows, in agreement with previous numerical studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An imaging vector magnetograph for the next solar maximum

Researchers describe the conceptual design of a new imaging vector magnetograph currently being constructed at the University of Hawaii. The instrument combines a modest solar telescope with a rotating quarter-wave plate, an acousto-optical tunable prefilter as a blocker for a servo-controlled Fabry-Perot etalon, CCD cameras, and on-line digital image processing. Its high spatial resolution (1/2 arcsec pixel size) over a large field of view (5 by 5 arcmin) will be sufficient to significantly measure, for the first time, the magnetic energy dissipated in major solar flares. Its millisecond tunability and wide spectral range (5000 to 7000 A) enable nearly simultaneous vector magnetic field measurements in the gas-pressure-dominated photosphere and magnetically-dominated chromosphere, as well as effective co-alignment with Solar-A's X ray images. Researchers expect to have the instrument in operation at Mees Solar Observatory (Haleakala) in early 1991. They have chosen to use tunable filters as wavelength-selection elements in order to emphasize the spatial relationships between magnetic field elements, and to permit construction of a compact, efficient instrument. This means that spectral information must be obtained from sequences of images, which can cause line profile distortions due to effects of atmospheric seeing.

Mickey, D. L.↗

Ion-Scale Secondary Flux Ropes Generated by Magnetopause Reconnection as Resolved by MMS

New Magnetospheric Multiscale (MMS) observations of small-scale (approx. 7 ion inertial length radius) flux transfer events (FTEs) at the dayside magnetopause are reported. The 1O km MMS tetrahedron size enables their structure and properties to be calculated using a variety of multispacecraft techniques, allowing them to be identified as flux ropes, whose flux content is small (approx. 22 kWb).The current density, calculated using plasma and magnetic field measurements independently, is found to be filamentary. lntercomparison of the plasma moments with electric and magnetic field measurements reveals structured non-frozen-in ion behavior. The data are further compared with a particle-in-cell simulation. It is concluded that these small-scale flux ropes, which are not seen to be growing, represent a distinct class of FTE which is generated on the magnetopause by secondary reconnection.

Eastwood, J. P.↗

Laser-driven quasi-static B-fields for magnetized high-energy-density experiments

We present measurements of magnetic fields generated in laser-driven coil targets irradiated by laser pulses of nanosecond duration, 1.053 μm wavelength, 500 J energy, and ∼1015 W/cm2 intensity, at the LULI2000 facility. Using two perpendicular probing axes, proton deflectometry is used to characterize the coil current and static charge at different times. Results reveal various deflection features that can be unambiguously linked to a looping quasi-steady current of well-understood polarity or to a static charging of the coil surface. Measured currents are broadly consistent with predictions from a laser-driven diode-current source and lumped circuit model, supporting the quasi-steady assessment of the discharges. Peak magnetic fields of ∼50 T at the center of 500-μm-diameter coils, obtained at the moderate laser intensity, open up the use of such laser-driven coil targets at facilities worldwide to study numerous phenomena in magnetized high-energy-density plasmas, and its potential applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision Measurement of the Neutron Magnetic Form Factor via the Ratio Method at Jefferson Lab Hall A

Protons and neutrons, collectively known as nucleons, are composed of quarks and gluons. The Sachs electromagnetic form factors encode information about the spatial distributions of charge and magnetization in the nucleon, particularly at low momentum transfer. In particular, the neutron magnetic form factor (GMn) provides crucial information about the distribution of magnetization inside the neutron and helps constrain theoretical models of nucleon structure. Quasi-elastic electron scattering from deuterium was measured up to Q^2=13.5 GeV^2 using the Super BigBite Spectrometer in Hall A at Jefferson Lab. In this work, the neutron magnetic form factor GMn was extracted at Q^2 = 3.0 GeV^2 and Q^2=4.5 GeV^2 using the Ratio Method. These results represent a subset of the full dataset collected in this experiment, which extended to significantly higher Q^2. The extracted GMn values agree with the existing global fit within approximately two standard deviations at Q^2=3.0 and show excellent agreement at Q^2=4.5. The measurements achieved systematic uncertainties of about 2% and statistical uncertainties below 0.5%, among the most precise determinations of GMn at these kinematics. These results demonstrate the robustness of the experimental technique and provide an important validation point for future extractions at higher Q^2, where data remain scarce. In addition, the GRINCH heavy gas Cherenkov detector—a key component of the experimental apparatus—was commissioned and achieved an electron detection efficiency of approximately 97%, supporting reliable particle identification. Together, the analysis presented here advances both our understanding of nucleon structure and the validation of the experimental methods and instrumentation used to access it.

Satnik, Maria [College of William and Mary, Willia↗

Low-temperature spin dynamics in the TmFeO 3 orthoferrite with a non-Kramers ion

We investigate the magnetic dynamics of the orthorhombic perovskite TmFeO 3 at low temperatures, below the spin reorientation transition at TSR≈80 K, by means of time-of-flight neutron spectroscopy. We find that the magnetic excitation spectrum combines two emergent collective modes associated with different magnetic sublattices. The Fe subsystem orders below TN~632 K into a canted antiferromagnetic structure and exhibits sharp, high-energy magnon excitations. We describe them using linear spin-wave theory, and reveal a pronounced anisotropy between in- and out-of-plane exchange interactions, which was mainly neglected in previous reports on the spin dynamics in orthoferrites. At lower energies, we find two crystalline electrical field (CEF) excitations of Tm3+ ions at energies of ~2 and 5 meV. In contrast to the sister compound YbFeO 3 , where the Yb 3+ ions form quasi-one-dimensional chains along the c axis, the Tm excitations show dispersion along both directions in the (0KL) scattering plane. Analysis of the neutron scattering polarization factor reveals a longitudinal polarization of the 2 meV excitation. To evaluate the effect of the CEF on the Tm 3+ ions, we perform point-charge model calculations, and their results quantitatively capture the main features of Tm single-ion physics, such as energies, intensities, and polarization of the CEF transitions, and the type of magnetic anisotropy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Small-scale variations in the galactic magnetic field - The rotation measure structure function and birefringence in interstellar scintillations

The structure function of rotation measures of extragalactic sources and birefringence in interstellar scintillations are used to investigate variations in the interstellar magnetic field on length scales of about 0.01-100 pc and 10 to the 11th cm, respectively. Model structure functions are derived for the case of a power-law power spectrum of irregularities in the quantity (n(e)B), and an estimate for the structure function is computed for several regions of the sky using data on extragalactic sources. The results indicate an outer angular scale for rotation measure (RM) variations of not less than about 5 deg (a linear scale of about 9-90 pc at a distance of 0.1-1 kpc). There is also evidence for RM variations on angular scales as small as 1 arcmin, but it cannot be determined whether these are intrinsic to the source or caused by the interstellar medium. The effect of a random, Faraday-active medium on the diffraction of radio waves is derived, and an upper limit to the variations in n(e)B on a length scale of 10 to the 11th cm is obtained from available observations.

Simonetti, J. H.↗

Optical position measurement for a Large Gap Magnetic Suspension System

This paper describes the design of an optical position measurement system which is being built as part of the NASA Langley Large Gap Magnetic Suspension System (LGMSS). The LGMSS is a five degree-of-freedom, large-gap magnetic suspension system which is being built for Langley Research Center as part of the Advanced Controls Test Facility (ACTF). The LGMSS consists of a planar array of electromagnets which levitate and position a cylindrically shaped model containing a permanent magnet core. The optical position measurement system provides information on the location and orientation of the model to the LGMSS control system to stabilize levitation of the model.

Welch, Sharon S.↗

The Galileo plasma wave investigation

The purpose of the Galileo plasma wave investigation is to study plasma waves and radio emissions in the magnetosphere of Jupiter. The plasma wave instrument uses an electric dipole antenna to detect electric fields, and two search coil magnetic antennas to detect magnetic fields. The frequency range covered is 5 Hz to 5.6 MHz for electric fields and 5 Hz to 160 kHz for magnetic fields. Low time-resolution survey spectrums are provided by three on-board spectrum analyzers. In the normal mode of operation the frequency resolution is about 10 percent, and the time resolution for a complete set of electric and magnetic field measurements is 37.33 s. High time-resolution spectrums are provided by a wideband receiver. The wideband receiver provides waveform measurements over bandwidths of 1, 10, and 80 kHz. Compared to previous measurements at Jupiter this instrument has several new capabilities. These new capabilities include (1) both electric and magnetic field measurements to distinguish electrostatic and electromagnetic waves, (2) direction finding measurements to determine source locations, and (3) increased bandwidth for the wideband measurements.

Gurnett, D. A.↗

Joint and angle-covariant spin measurements with a quadrupole magnetic field

We study a Stern-Gerlach type setup, with a quadrupole magnetic field, for neutral particles of arbitrary spin. The Hamiltonian is of a form proposed for joint measurements of the incompatible observables. The measurement results are discussed, showing the limitation of such Hamiltonians. Some remarks are made on the relevance of covariance as a criterion for measurement schemes.

Martens, Hans↗

Magneto-optical study of Nb thin films for superconducting qubits

Among the recognized sources of decoherence in superconducting qubits, the spatial inhomogeneity of the superconducting state and the possible presence of magnetic-flux vortices remain comparatively underexplored. Niobium is commonly used as a structural material in transmon qubits that host Josephson junctions, and excess dissipation anywhere in the transmon can become a bottleneck that limits overall quantum performance. The metal/substrate interfacial layer may simultaneously host pair-breaking loss channels (e.g., two-level systems, TLS) and control thermal transport, thereby affecting dissipation and temperature stability. Here, we use quantitative magneto-optical imaging of the magnetic-flux distribution to characterize the homogeneity of the superconducting state and the critical current density, $j_{c}$, in niobium films fabricated under different sputtering conditions. The imaging reveals distinct flux-penetration regimes, ranging from a nearly ideal Bean critical state to strongly nonuniform thermo-magnetic dendritic avalanches. By fitting the measured magnetic-induction profiles, we extract $j_{c}$ and correlate it with film physical properties and with measured qubit internal quality factors. Our results indicate that the Nb/Si interlayer can be a significant contributor to decoherence and should be considered an important factor that must be optimized.

Datta, Amlan [Ames Lab; Iowa State U.]↗