Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

High resolution laser induced fluorescence Doppler velocimetry utilizing saturated absorption spectroscopy

A high resolution laser induced fluorescence (LIF) system has been developed to measure the flow velocity field of neutral particles in an electron-cyclotron-resonance argon plasma. The flow velocity has been determined by the Doppler shift of the LIF spectrum, which is proportional to the velocity distribution function. Very high accuracy in velocity determination has been achieved by installing a saturated absorption spectroscopy unit into the LIF system, where the absolute value and scale of laser wavelength are determined by using the Lamb dip and the fringes of a Fabry-Perot interferometer. The minimum detectable flow velocity of a newly developed LIF system is {+-}2 m/s, and this performance remains unchanged in a long-time experiment. From the radial measurements of LIF spectra of argon metastable atoms, it is found that there exists an inward flow of neutral particles associated with neutral depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-contrast imaging and tomography at 60 keV using a conventional x-ray tube source

Phase-contrast imaging at laboratory-based x-ray sources using grating interferometers has been developed over the last few years for x-ray energies of up to 28 keV. Here, we show first phase-contrast projection and tomographic images recorded at significantly higher x-ray energies, produced by an x-ray tube source operated at 100 kV acceleration voltage. We find our measured tomographic phase images in good agreement with tabulated data. The extension of phase-contrast imaging to this significantly higher x-ray energy opens up many applications of the technique in medicine and industrial nondestructive testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase transition dynamics and gravitational waves

During a first-order phase transition, gravitational radiation is generated either by bubble collisions or by turbulence. For phase transitions which took place at the electroweak scale and beyond, the signal is expected to be within the sensitivity range of planned interferometers such as LISA or BBO. We review the generation of gravitational waves in a first-order phase transition and discuss the dependence of the spectrum on the dynamics of the phase transition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled analysis of high and low frequency resonant ultrasound spectroscopy: Application to the detection of defects in ceramic balls

A coupled analysis of high and low frequency resonant ultrasound spectroscopy of spheroidal modes is presented in this paper. Experimentally, by using an ultrasonic probe for the excitation (piezoelectric transducer) and a heterodyne optic probe for the receiver (interferometer), it was possible to take spectroscopic measurements of spheroidal vibrations over a large frequency range of 100 kHz-45 MHz in a continuous regime. This wide analysis range enabled variations in velocity due to the presence of defects to be differentiated from the inherent characteristics of the balls and consequently, it offers the possibility of detecting cracks independently of production variations. This kind of defect is difficult to detect because the C-shaped surface crack is very small and narrow (500x5 {mu}m{sup 2}), and its depth does not exceed 50 {mu}m. The proposed methodology can excite spheroidal vibrations in the ceramic balls and detect such vibrations over a large frequency range. On the one hand, low frequency resonances are used in order to estimate the elastic coefficients of the balls according to various inspection depths. This method has the advantage of providing highly accurate evaluations of the elastic coefficients over a wide frequency range. On the other hand, high frequency vibrations are considered because they are similar to the surface waves propagating in the surface zone of the ceramic balls and consequently can be used to detect C-crack defects.

36 MATERIALS SCIENCE↗

Hyperthermal atomic oxygen source for near-space simulation experiments

A hyperthermal atomic oxygen (AO) beam facility has been developed to investigate the collisions of high-velocity AO atoms with vapor-phase counterflow. Application of 4.5 kW, 2.4 GHz microwave power in the source chamber creates a continuous discharge in flowing O{sub 2} gas. The O{sub 2} feedstock is introduced into the source chamber in a vortex flow to constrain the plasma to the center region, with the chamber geometry promoting resonant excitation of the TM{sub 011} mode to localize the energy deposition in the vicinity of the aluminum nitride (AlN) expansion nozzle. The approximately 3500 K environment serves to dissociate the O{sub 2}, resulting in an effluent consisting of 40% AO by number density. Downstream of the nozzle, a silicon carbide (SiC) skimmer selects the center portion of the discharge effluent, prior to the expansion reaching the first shock front and rethermalizing, creating a beam with a derived 2.5 km s{sup -1} velocity. Differential pumping of the skimmer chamber, an optional intermediate chamber and reaction chamber maintains a reaction chamber pressure in the mid-10{sup -6} to mid-10{sup -5} Torr range. The beam has been characterized with regard to total AO beam flux, O{sub 2} dissociation fraction, and AO spatial profile using time-of-flight mass spectrometric and Kapton-H erosion measurements. A series of reactions AO+C{sub n}H{sub 2n} (n=2-4) has been studied under single-collision conditions using mass spectrometric product detection, and at higher background pressure detecting dispersed IR emissions from primary and secondary products using a step-scan Michelson interferometer. In a more recent AO crossed-beam experiment, number densities and predicted IR emission intensities have been modeled using the direct simulation Monte Carlo technique. The results have been used to guide the experimental conditions. IR emission intensity predictions are compared to detected signal levels to estimate absolute reaction cross sections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Inner Environment of Protoplanetary Disks With Near-infrared Spectro-interferometry

In this paper, I review how optical spectro-interferometry has become a particularly well-suited technique to study the close environment of young stars by spatially resolving both their infrared continuum and line emission regions. I summarize the ways optical interferometers have brought major insights about our understanding of the inner part of circumstellar disks, a region in which the first stages of planet formation are thought to occur. In particular, I emphasize how new methods are now enabling to probe the hot gas emission, in addition to the circumstellar dust.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and characterization of supersonic nozzles for wide focus laser-plasma interactions

In this work we optimize the contour of supersonic nozzles to produce long and stable gas jets suitable to be used in loose focus laser-plasma applications. The nozzle design method takes into account the inclusion of a boundary layer that increases the length of the usable gas jet. Two 8 mm supersonic nozzles were characterized, one with a Mach number of 3 and another with a Mach number of 6, using a Mach-Zehnder interferometer performed with a He:Ne 4 cm expanded laser beam. The experimental results confirm that the inclusion of the boundary layer produces an 8 mm constant longitudinal density profile for the nozzle with a Mach number of 6 (NM6) and a 4.5 mm constant longitudinal density profile for the nozzle with a Mach number of 3 (NM3).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High temperature dilatation measurements by in situ laser interferometry under high magnetic field

This article contains a description of a laser interferometer coupled with a furnace for in situ dilatation measurements under high magnetic field. The apparatus fits an 18 T superconducting magnet with a 32 mm diameter room temperature bore. This optical method was chosen for dilatation measurements because it is not perturbated by the magnetic field. The measured sample can be heated up to 1500 K under a controlled atmosphere, and heating and cooling rates can be varied within a range of 10 K/s. The resolution is below 50 nm. As an example of using in situ dilatation measurements to follow phase transformations, the increase in the ferrite/austenite transformation temperature in pure iron in a magnetic field up to 16 T was experimentally evidenced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Descriptions of a linear device developed for research on advanced plasma imaging and dynamics

The research on advanced plasma imaging and dynamics (RAPID) device is a newly developed linear electron cyclotron resonance (ECR) plasma device. It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. A 6 kW 2.45 GHz magnetron is used to produce steady-state ECR plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). The cylindrical stainless steel vacuum chamber is 300 mm in diameter and 750 mm in length and has eight radial and ten axial ports including 6-in. and 8-in. viewing windows for heating and diagnostics. Experimental observation of ECR plasma heating has been recently carried out during the initial plasma operation. The main diagnostic systems including a 94 GHz heterodyne interferometer, a high-resolution 25 channel one-dimensional array spectrometer, a single channel survey spectrometer, and an electric probe have been also prepared. The RAPID device is a flexible simulator for the understanding of tokamak edge plasma physics and new diagnostic system development. In this work, we describe the RAPID device and initial operation results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the electron density in a microwave plasma torch at atmospheric pressure

The electron density in a microwave plasma torch at atmospheric pressure was measured with a Mach-Zehnder interferometer. The electron density is on the order of 10{sup 17}/cm{sup 3}, one order higher than that deduced from the Stark broadening of spectral lines, and increases with the increase in the microwave power. The spatial distribution of the electron density was obtained. The highest electron density locates at the symmetrical axis of the plasma torch and decreases radially. It was found that the electron density fluctuates within a range of 0.3 with the time under the same experimental conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fundamental experiments in velocimetry

One can understand what velocimetry does and does not measure by understanding a few fundamental experiments. Photon Doppler Velocimetry (PDV) is an interferometer that will produce fringe shifts when the length of one of the legs changes, so we might expect the fringes to change whenever the distance from the probe to the target changes. However, by making PDV measurements of tilted moving surfaces, we have shown that fringe shifts from diffuse surfaces are actually measured only from the changes caused by the component of velocity along the beam. This is an important simplification in the interpretation of PDV results, arising because surface roughness randomizes the scattered phases.

66↗

LINE-IMAGING ORVIS MEASUREMENTS OF INTERFEROMETRIC WINDOWS UNDER QUASI-ISENTROPIC COMPRESSION

A line-imaging optically recording velocity interferometer system (ORVIS) has been implemented on the Veloce pulsed power generator to enable measurement of spatially resolved velocity histories of materials under dynamic compression. Interferometric windows are regularly used to maintain the high-pressure state of shock and ramp (quasi-isentropic) loaded materials. Although imaging through a shock or fast ramp (<=10 ns) loaded window material has been reasonably successful, for slower ramp loading (approx440 ns) experiments, the elastic-plastic yielding of the window has an adverse effect on return light to the line-imaging ORVIS. The results of quasi-isentropic loading experiments with various interferometric windows such as LiF, PMMA, NaCl, quartz and sapphire are presented.

36 MATERIALS SCIENCE↗

STUDY OF IRON UNDER HIGH PRESSURE CONDITIONS USING ISENTROPIC COMPRESSION

We use directly driven method to compress the iron along isentropic path. By adjusting the pulse intensity of laser to increase with time, we directly ablated the iron target with laser to achieve isentropic compression. Rear surface velocities of the iron targets were recorded by VISAR (Velocity Interferometer System for Any Reflector). The iron a (bcc) to epsilon(hcp) phase transformation was clearly observed. Experiment results were compared with simulations.

36 MATERIALS SCIENCE↗

A high-resolution two-dimensional imaging velocimeter

Velocity interferometers are typically used to measure velocities of surfaces at a single point or along an imaged line as a function of time. We describe an optical arrangement that enables high-resolution measurements of the two-dimensional velocity field across a shock front or shocked interface. The technique is employed to measure microscopic fluctuations in shock fronts that have passed through materials being considered as ablators for indirect-drive inertial confinement fusion. With picosecond time resolution the instrument captures velocity modes with wavelengths as short as 2.5 {mu}m at a resolution of {approx}10 m/s rms on velocity fields averaging many km/s over an 800 {mu}m field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Characterization of the plasma parameters of a capillary discharge-produced plasma channel waveguide to guide an intense laser pulse

We demonstrated the production of an optical waveguide in a capillary discharge-produced plasma using a cylindrical capillary. Plasma parameters of its waveguide were characterized by use of both a Nomarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 400 A. An ultrashort, intense laser pulse was guided by use of this plasma channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics for first plasma and development plan on KSTAR

The first plasma with target values of the plasma current and the pulse duration was finally achieved on June 13, 2008 in the Korea Superconducting Tokamak Advanced Research (KSTAR). The diagnostic systems played an important role in achieving successful first plasma operation for the KSTAR tokamak. The employed plasma diagnostic systems for the KSTAR first plasma including the magnetic diagnostics, millimeter-wave interferometer, inspection illuminator, H{sub {alpha}}, visible spectrometer, filterscope, and electron cyclotron emission (ECE) radiometer have provided the main plasma parameters, which are essential for the plasma generation, control, and physics understanding. Improvements to the first diagnostic systems and additional diagnostics including an x-ray imaging crystal spectrometer, reflectometer, ECE radiometer, resistive bolometer, and soft x-ray array are scheduled to be added for the next KSTAR experimental campaign in 2009.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Software Tool for Processing the Displacement Time Series Extracted from Raw Radar Data

The application of high-resolution radar waveform and interferometric principles recently led to the development of a microwave interferometer, suitable to simultaneously measuring the (static or dynamic) deflection of several points on a large structure. From the technical standpoint, the sensor is a Stepped Frequency Continuous Wave (SF-CW), coherent radar, operating in the K{sub u} frequency band.In the paper, the main procedures adopted to extract the deflection time series from raw radar data and to assess the quality of data are addressed, and the MATLAB toolbox developed is described. Subsequently, other functions implemented in the software tool (e.g. evaluation of the spectral matrix of the deflection time-histories, identification of natural frequencies and operational mode shapes evaluation) are described and the application to data recorded on full-scale bridges is exemplified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single frequency stable VCSEL as a compact source for interferometry and vibrometry

Developing an innovative PS-DAVLL (Polarization Switching DAVLL) method of frequency stabilization, which used a ferroelectric liquid crystal cell as quarter wave plate, rubidium cell and developed ultra-stable current source, allowed to obtain a frequency stability of 10{sup -9}(frequency reproducibility of 1,2centre dot10{sup -8}) and reductions in external dimensions of laser source. The total power consumption is only 1,5 Watt. Because stabilization method used in the frequency standard is insensitive to vibration, the semiconductor laser interferometer was built for measuring range over one meter, which can also be used in industry for the accurate measurement of displacements with an accuracy of 1[mum/m]. Measurements of the VCSEL laser parameters are important from the standpoint of its use in laser interferometry or vibrometry, like narrow emission line DELTAnu{sub FWHM} = 70[MHz] equivalent of this laser type and stability of linear polarization of VCSEL laser. The undoubted advantage of the constructed laser source is the lack of mode-hopping effect during continuous work of VCSEL.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗