Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “improvements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Beam Current Improvements on the Axcelis Optima HD Imax Implanter

The ability to use large molecular species such as octadecaborane (B{sub 18}H{sub 22}) has been investigated at semiconductor device manufacturers as a way to significantly increase wafer throughput relative to standard high current ion implanters. Over the past two years, improvements in the machine design to support the use of B{sub 18}H{sub 22} have led to beam current increases of 50% from 30 pmA to 45 pmA of boron at an equivalent boron energy of 4 keV. This boron energy is required by p{sup +} doping of dual poly gate (DPG) structures in DRAM. Beam current has also been significantly improved at the low equivalent boron energies anticipated to be required by 32 nm processes for PMOS source/drain extensions (SDE). For example, at 250 eV equivalent beam energy, a 100% increase in cluster boron beam current has been attained.This paper describes the techniques by which these beam current improvements were accomplished, primarily through the refinement of ion beam optics. Other techniques for increasing overall tool productivity are also described, such as beam utilization and overall operational improvements. Wafer throughputs are presented for critical p{sup +} implant processes such as dual poly gate (DPG), source/drain (S/D), source drain extension (SDE) and S/D contact. The higher throughputs resulting from these changes are translated into a cost per wafer (CPW) model and it is demonstrated that an increase in average beam current is the largest contributor to a reduction in CPW.

36 MATERIALS SCIENCE↗

A metrological large range atomic force microscope with improved performance

A metrological large range atomic force microscope (Met. LR-AFM) has been set up and improved over the past years at Physikalisch-Technische Bundesanstalt (PTB). Being designed as a scanning sample type instrument, the sample is moved in three dimensions by a mechanical ball bearing stage in combination with a compact z-piezostage. Its topography is detected by a position-stationary AFM head. The sample displacement is measured by three embedded miniature homodyne interferometers in the x, y, and z directions. The AFM head is aligned in such a way that its cantilever tip is positioned on the sample surface at the intersection point of the three interferometer measurement beams for satisfying the Abbe measurement principle. In this paper, further improvements of the Met. LR-AFM are reported. A new AFM head using the beam deflection principle has been developed to reduce the influence of parasitic optical interference phenomena. Furthermore, an off-line Heydemann correction method has been applied to reduce the inherent interferometer nonlinearities to less than 0.3 nm (p-v). Versatile scanning functions, for example, radial scanning or local AFM measurement functions, have been implemented to optimize the measurement process. The measurement software is also improved and allows comfortable operations of the instrument via graphical user interface or script-based command sets. The improved Met. LR-AFM is capable of measuring, for instance, the step height, lateral pitch, line width, nanoroughness, and other geometrical parameters of nanostructures. Calibration results of a one-dimensional grating and a set of film thickness standards are demonstrated, showing the excellent metrological performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emittance improvement efforts on the 15-20 mA dc H{sup -} multicusp source

A 15 mA beam from the 15-20 mA dc H{sup -} multicusp source has been obtained at China Institute of Atomic Energy. In order to improve the emittance of extracted beam from this new multicusp source, some measures have been taken, i.e., increasing the length of the ion source body, improving the vacuum in the extraction area, injecting cesium vapor into the ion source, etc. The hardware, including the lengthened source body, the improved back cover and cesium heating system, and the extraction vacuum box, will be described. Initial results for these efforts aimed at emittance improvement will also be given in the paper.

43 PARTICLE ACCELERATORS↗

Tailoring the laser pulse shape to improve the quality of the self-injected electron beam in laser wakefield acceleration

In laser wakefield acceleration, tailoring the shape of the laser pulse is one way of influencing the laser-plasma interaction and, therefore, of improving the quality of the self-injected electron beam in the bubble regime. Using three-dimensional particle-in-cell simulations, the evolution dynamics of the laser pulse and the quality of the self-injected beam, for a Gaussian pulse, a positive skew pulse (i.e., one with sharp rise and slow fall), and a negative skew pulse (i.e., one with a slow rise and sharp fall) are studied. It is observed that with a negative skew laser pulse there is a substantial improvement in the emittance (by around a factor of two), and a modest improvement in the energy-spread, compared to Gaussian as well as positive skew pulses. However, the injected charge is less in the negative skew pulse compared to the other two. It is also found that there is an optimal propagation distance that gives the best beam quality; beyond this distance, though the energy increases, the beam quality deteriorates, but this deterioration is least for the negative skew pulse. Thus, the negative skew pulse gives an improvement in terms of beam quality (emittance and energy spread) over what one can get with a Gaussian or positive skew pulse. In part, this is because of the lesser injected charge, and the strong suppression of continuous injection for the negative skew pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvement of light extraction efficiency and reduction of driving voltage in organic light emitting diodes using a plasmonic crystal

Two-dimensional periodic corrugation was introduced into the surface of metallic cathodes of organic light-emitting diodes (OLEDs) to extract surface plasmon energy, which is trapped in that surface, as free-space photons. The dependence of the improvement factor of the emission efficiency on the modulation depth of the corrugation was systematically investigated. The corrugation was fabricated by using a colloidal lithography technique, which can be easily applied to a wide area. The obtained maximum improvement factor in current efficiency was 1.67 for an OLED with a 40 nm modulation depth, whereas the improvement in power efficiency was 2.35 for an OLED with a 60 nm modulation depth. We attributed the former improvement factor purely to optical effects and the latter to both optical and electrical effects, namely, a reduction of the electrical resistance of the organic layers due to the introduced corrugation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

How much improvement in thermoelectric performance can come from reducing thermal conductivity?

Large improvements in the performance of thermoelectric materials have come from designing materials with reduced thermal conductivity. Yet as the thermal conductivity of some materials now approaches their amorphous limit, it is unclear if microstructure engineering can further improve thermoelectric performance in these cases. In this contribution, we use large data sets to examine 300 compositions in 11 families of thermoelectric materials and present a type of plot that quickly reveals the maximum possible zT that can be achieved by reducing the thermal conductivity. This plot allows researchers to quickly distinguish materials where the thermal conductivity has been optimized from those where improvement can be made. Moreover, through these large data sets we examine structure-property relationships to identify methods that decrease thermal conductivity and improve thermoelectric performance. We validate, with the data, that increasing (i) the volume of a unit cell and/or (ii) the number of atoms in the unit cell decreases the thermal conductivity of many classes of materials, without changing the electrical resistivity.

36 MATERIALS SCIENCE↗

A comparative study of lock-in-amplifiers and improved duffing chaotic oscillators for the detection and processing of weak signals

The measurement of multiphase flow parameters is of great importance in a wide range of industries. In the measurement of multiphase, the signals from the sensors are extremely weak and often buried in strong background noise. It is thus desirable to develop effective signal processing techniques that can detect the weak signal from the sensor outputs. In this paper, two methods, i.e., lock-in-amplifier (LIA) and improved Duffing chaotic oscillator are compared to detect and process the weak signal. For sinusoidal signal buried in noise, the correlation detection with sinusoidal reference signal is simulated by using LIA. The improved Duffing chaotic oscillator method, which based on the Wigner transformation, can restore the signal waveform and detect the frequency. Two methods are combined to detect and extract the weak signal. Simulation results show the effectiveness and accuracy of the proposed improved method. The comparative analysis shows that the improved Duffing chaotic oscillator method can restrain noise strongly since it is sensitive to initial conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasound guided fluorescence molecular tomography with improved quantification by an attenuation compensated born-normalization and in vivo preclinical study of cancer

Ultrasound imaging, having the advantages of low-cost and non-invasiveness over MRI and X-ray CT, was reported by several studies as an adequate complement to fluorescence molecular tomography with the perspective of improving localization and quantification of fluorescent molecular targets in vivo. Based on the previous work, an improved dual-modality Fluorescence-Ultrasound imaging system was developed and then validated in imaging study with preclinical tumor model. Ultrasound imaging and a profilometer were used to obtain the anatomical prior information and 3D surface, separately, to precisely extract the tissue boundary on both sides of sample in order to achieve improved fluorescence reconstruction. Furthermore, a pattern-based fluorescence reconstruction on the detection side was incorporated to enable dimensional reduction of the dataset while keeping the useful information for reconstruction. Due to its putative role in the current imaging geometry and the chosen reconstruction technique, we developed an attenuation compensated Born-normalization method to reduce the attenuation effects and cancel off experimental factors when collecting quantitative fluorescence datasets over large area. Results of both simulation and phantom study demonstrated that fluorescent targets could be recovered accurately and quantitatively using this reconstruction mechanism. Finally, in vivo experiment confirms that the imaging system associated with the proposed image reconstruction approach was able to extract both functional and anatomical information, thereby improving quantification and localization of molecular targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvement of graphene field-effect transistors by hexamethyldisilazane surface treatment

We report the improvement of the electrical characteristics of graphene field-effect transistors (FETs) by hexamethyldisilazane (HMDS) treatment. Both electron and hole field-effect mobilities are increased by 1.5 × –2×, accompanied by effective residual carrier concentration reduction. Dirac point also moves closer to zero Volt. Time evolution of mobility data shows that mobility improvement saturates after a few hours of HMDS treatment. Temperature-dependent transport measurements show small mobility variation between 77 K and room temperature (295 K) before HMDS application. But mobility at 77 K is almost 2 times higher than mobility at 295 K after HMDS application, indicating reduced carrier scattering. Performance improvement is also observed for FETs made on hydrophobic substrate–an HMDS-graphene-HMDS sandwich structure. Raman spectroscopic analysis shows that G peak width is increased, G peak position is down shifted, and intensity ratio between 2D and G peaks is increased after HMDS application. We attribute the improvements in electronic transport mainly to enhanced screening and mitigation of adsorbed impurities from graphene surface upon HMDS treatment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved optogalvanic detection with voltage biased Langmuir probes

Optogalvanic detectors show great potential for infrared spectroscopy, especially in cavity enhanced techniques where they, in contrast to ordinary absorption detectors, can perform intracavity measurements. This enables them to utilize the signal-to-noise ratio improvement gained from the extended effective path length inside an optical cavity, without losing signal strength due to the limited amount of light exiting through the rear mirror. However, if optogalvanic detectors are to become truly competitive, their intrinsic sensitivity and stability has to be improved. This, in turn, requires a better understanding of the mechanisms behind the generation of the optogalvanic signal. The study presented here focuses on an optogalvanic detector based on a miniaturized stripline split-ring resonator plasma source equipped with Langmuir probes for detecting the optogalvanic signal. In particular, the effect of applying a constant bias voltage to one of the probes is investigated, both with respect to the sensitivity and stability, and to the mechanism behind the generation of the signal. Experiments with different bias voltages at different pressures and gas composition have been conducted. In particular, two different gas compositions (pure CO{sub 2} and 0.25% CO{sub 2} in 99.75% N{sub 2}) at six different pressures (100 Pa to 600 Pa) have been studied. It has been shown that probe biasing effectively improves the performance of the detector, by increasing the amplitude of the signal linearly over one order of magnitude, and the stability by about 40% compared with previous studies. Furthermore, it has been shown that relatively straightforward plasma theory can be applied to interpret the mechanism behind the generation of the signal, although additional mechanisms, such as rovibrational excitation from electron-molecule collisions, become apparent in CO{sub 2} plasmas with electron energies in the 1–6 eV range. With the achieved performance improvement and the more solid theoretical framework presented here, stripline split-ring resonator optogalvanic detectors can evolve into a compact, inexpensive, and easy-to-operate alternative for future infrared spectrometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved scaling of temperature-accelerated dynamics using localization

While temperature-accelerated dynamics (TAD) is a powerful method for carrying out non-equilibrium simulations of systems over extended time scales, the computational cost of serial TAD increases approximately as N{sup 3} where N is the number of atoms. In addition, although a parallel TAD method based on domain decomposition [Y. Shim et al., Phys. Rev. B 76, 205439 (2007)] has been shown to provide significantly improved scaling, the dynamics in such an approach is only approximate while the size of activated events is limited by the spatial decomposition size. Accordingly, it is of interest to develop methods to improve the scaling of serial TAD. As a first step in understanding the factors which determine the scaling behavior, we first present results for the overall scaling of serial TAD and its components, which were obtained from simulations of Ag/Ag(100) growth and Ag/Ag(100) annealing, and compare with theoretical predictions. We then discuss two methods based on localization which may be used to address two of the primary “bottlenecks” to the scaling of serial TAD with system size. By implementing both of these methods, we find that for intermediate system-sizes, the scaling is improved by almost a factor of N{sup 1/2}. Some additional possible methods to improve the scaling of TAD are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prompt core confinement improvement across the L–H transition in DIII-D: Profile stiffness, turbulence dynamics, and isotope effect

Here, we elaborate on the nature of the prompt core confinement improvement observed at the L–H transition in DIII-D, which is a long-standing issue unsolved for more than two decades and can impact future fusion reactor performance. Dynamic transport analysis suggests the essential role of the profile stiffness for understanding the mechanism of the prompt core confinement improvement. Beam emission spectroscopy shows that transport reduction at the core cannot be explained only by the ion scale turbulence density fluctuation suppression. Properties of nonlocal confinement improvement across the L–H transition are experimentally assessed in hydrogen (H) and deuterium (D) plasmas. Prompt core confinement improvement is found to be more rapid in the lighter hydrogen isotope.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unsupervised Learning for Improved Gamma-Ray Spectrometry in Pixelated Cadmium Zinc Telluride (CZT) Detectors

Machine learning has been found to be ubiquitously useful across many industries, presenting an opportunity to improve radiation detection performance using data-driven algorithms. Improved detector resolution can aid in the detection, identification, and quantification of radionuclides. Here, in this work, a novel, data-driven, unsupervised learning approach is developed to improve detector spectral characteristics by learning, and subsequently rejecting, poorly performing regions of the pixelated detector. Feature engineering is used to fit individual characteristic photo peaks to a Doniach lineshape with a linear background model. Then, principal component analysis is used to learn a lower-dimension latent space representation of each photo peak where the pixels are clustered, and subsequently ranked, based on the cluster mean distance to an optimal point. Pixels within the worst cluster(s) are rejected to improve the full-width at half-maximum (FWHM) by 10% to 15% (relative to the bulk detector) at 50% net efficiency when applied to training data obtained from measurements of a 100 μCi 154 Eu source using a H3D M400i pixelated cadmium zinc telluride detector. These results compare well with, but do not outperform, a greedy algorithm that accumulates pixels in order of FWHM from lowest to highest used as a benchmark. In the future, this approach can be extended to include the detector energy and angular response. Finally, the model is applied to newly seen natural and enriched uranium spectra relevant for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving the space surveillance telescope's performance using multi-hypothesis testing

The Space Surveillance Telescope (SST) is a Defense Advanced Research Projects Agency program designed to detect objects in space like near Earth asteroids and space debris in the geosynchronous Earth orbit (GEO) belt. Binary hypothesis test (BHT) methods have historically been used to facilitate the detection of new objects in space. In this paper a multi-hypothesis detection strategy is introduced to improve the detection performance of SST. In this context, the multi-hypothesis testing (MHT) determines if an unresolvable point source is in either the center, a corner, or a side of a pixel in contrast to BHT, which only tests whether an object is in the pixel or not. The images recorded by SST are undersampled such as to cause aliasing, which degrades the performance of traditional detection schemes. The equations for the MHT are derived in terms of signal-to-noise ratio (S/N), which is computed by subtracting the background light level around the pixel being tested and dividing by the standard deviation of the noise. A new method for determining the local noise statistics that rejects outliers is introduced in combination with the MHT. An experiment using observations of a known GEO satellite are used to demonstrate the improved detection performance of the new algorithm over algorithms previously reported in the literature. The results show a significant improvement in the probability of detection by as much as 50% over existing algorithms. In addition to detection, the S/N results prove to be linearly related to the least-squares estimates of point source irradiance, thus improving photometric accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

IMPROVED MEASUREMENTS OF THE TEMPERATURE AND POLARIZATION OF THE COSMIC MICROWAVE BACKGROUND FROM QUaD

We present an improved analysis of the final data set from the QUaD experiment. Using an improved technique to remove ground contamination, we double the effective sky area and hence increase the precision of our cosmic microwave background (CMB) power spectrum measurements by approx30% versus that previously reported. In addition, we have improved our modeling of the instrument beams and have reduced our absolute calibration uncertainty from 5% to 3.5% in temperature. The robustness of our results is confirmed through extensive jackknife tests, and by way of the agreement that we find between our two fully independent analysis pipelines. For the standard six-parameter LAMBDACDM model, the addition of QUaD data marginally improves the constraints on a number of cosmological parameters over those obtained from the WMAP experiment alone. The impact of QUaD data is significantly greater for a model extended to include either a running in the scalar spectral index, or a possible tensor component, or both. Adding both the QUaD data and the results from the Arcminute Cosmology Bolometer Array Receiver experiment, the uncertainty in the spectral index running is reduced by approx25% compared to WMAP alone, while the upper limit on the tensor-to-scalar ratio is reduced from r < 0.48 to r < 0.33 (95% c.l.). This is the strongest limit on tensors to date from the CMB alone. We also use our polarization measurements to place constraints on parity-violating interactions to the surface of last scattering, constraining the energy scale of Lorentz violating interactions to <1.5 x 10{sup -43} GeV (68% c.l.). Finally, we place a robust upper limit on the strength of the lensing B-mode signal. Assuming a single flat band power between l = 200 and l = 2000, we constrain the amplitude of B-modes to be <0.57 muK{sup 2} (95% c.l.).

79 ASTRONOMY AND ASTROPHYSICS↗

Annealing a Follow-up Program: Improvement of the Dark Energy Figure of Merit for Optical Galaxy Cluster Surveys

The precision of cosmological parameters derived from galaxy cluster surveys is limited by uncertainty in relating observable signals to cluster mass. We demonstrate that a small mass-calibration follow-up program can significantly reduce this uncertainty and improve parameter constraints, particularly when the follow-up targets are judiciously chosen. To this end, we apply a simulated annealing algorithm to maximize the dark energy information at fixed observational cost, and find that optimal follow-up strategies can reduce the observational cost required to achieve a specified precision by up to an order of magnitude. Considering clusters selected from optical imaging in the Dark Energy Survey, we find that approximately 200 low-redshift X-ray clusters or massive Sunyaev-Zel'dovich clusters can improve the dark energy figure of merit by 50%, provided that the follow-up mass measurements involve no systematic error. In practice, the actual improvement depends on (1) the uncertainty in the systematic error in follow-up mass measurements, which needs to be controlled at the 5% level to avoid severe degradation of the results; and (2) the scatter in the optical richness-mass distribution, which needs to be made as tight as possible to improve the efficacy of follow-up observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AN IMPROVED SPECTROSCOPIC ANALYSIS OF DA WHITE DWARFS FROM THE SLOAN DIGITAL SKY SURVEY DATA RELEASE 4

We present an improved spectroscopic and photometric analysis of hydrogen-line DA white dwarfs from the Sloan Digital Sky Survey Data Release 4 (SDSS DR4) based on model atmospheres that include improved Stark broadening profiles with non-ideal gas effects. We also perform a careful visual inspection of all spectroscopic fits with high signal-to-noise ratios (S/Ns > 12) and present improved atmospheric parameters (T{sub eff} and log g) for each white dwarf. Through a comparison of spectroscopic and photometric temperatures, we report the discovery of 35 DA+DB/DC double degenerate candidates and two helium-rich DA stars. We also determine that a cutoff at S/N = 15 optimizes the size and quality of the sample for computing the mean mass of DA white dwarfs, for which we report a value of 0.613 M{sub sun}. We compare our results to previous analyses of the SDSS DR4 and find a good agreement if we account for the shift produced by the improved Stark profiles. Finally, the properties of DA white dwarfs in the SDSS are weighed against those of the Villanova White Dwarf Catalog sample of Gianninas et al. We find systematically lower masses (by about 3% on average), a difference that we trace back to the data reduction procedure of the SDSS. We conclude that a better understanding of these differences will be important to determine the absolute temperature scale and mean mass of DA white dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

Stability analysis of WEST L-mode discharges with improved confinement from boron powder injection

WEST L-mode plasmas with dominant electron heating and no core torque source have observed improvements in confinement during boron (B) powder injection. These results are reminiscent of previous powder injection experiments on other devices and gaseous impurity seeding experiments on WEST. During powder injection, the stored energy increased up to 25% due to enhanced ion and electron heat and particle confinement. The improvements in confinement were not indicative of an L-H transition. To identify the dominant mechanisms and the causality chain behind these improvements in confinement, we employ interpretative modeling using METIS, predictive integrated modeling using a high-fidelity plasma simulator (HFPS), and stand-alone gyrokinetic simulations using quasi-linear gyrokinetic code. Interpretative modeling with METIS allowed for the estimation of missing data while maintaining good overall consistency with experiment. These results provided the initial conditions for fully predictive flux driven simulations using the HFPS. From these simulations, quasi-linear gyrokinetic analysis was performed at ρ = 0.5 and ρ = 0.65. Collisionality was found to be a strong candidate for the turbulence suppression mechanism at ρ = 0.5, while a combination of collisionality and the T e /T i ratio was found to be the likely mechanism at ρ = 0.65. The results additionally suggested that increased Z eff (through main ion dilution) could play a role in the improved confinement, but this could not be confirmed due to a lack of experimental measurements. The modeling framework established here can now be used to evaluate and exploit a variety of future powder injection experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗