Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hot wire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Quiet Spacecraft Cabin Ventilation Fan: Acoustic Measurements Results

A quiet spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were – static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the acoustic measurements as part of a series of reports.

Small Fan Noise↗

Quiet Spacecraft Cabin Ventilation Fan: Aerodynamic Measurements Results

A metal spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were – static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the aerodynamic measurements as part of a series of reports.

o Small Fan Noise, Testing, Duct Modes↗

Preliminary Measurements on the BOLT Geometry in the Supersonic Low Disturbance Tunnel

Experiments were performed in the Mach 3.5 Supersonic Low Disturbance Tunnel on the BOundary-Layer Transition (BOLT) geometry. The goal of this campaign was to assess changes to the transition front by varying the freestream noise and the model surface quality. The model was printed of polycarbonate and is 30% scale of the flight geometry. It was tested under noisy and quiet conditions at different streamwise positions in the tunnel and was also tested before and after improvements were made to the model surface through sanding and gap reduction. Pitch and yaw angles were nominally zero. The model surface temperature was measured using infrared thermography and thermocouples as the unit Reynolds number was swept from 4.75 – 15.8 × 10 6 m −1 . Boundary-layer transition was observed near the midspan of the model for unit Reynolds numbers above 10×10 6 m −1 in quiet flow, while transition was already observed on the shoulders below 5×10 6 m −1 in noisy flow. The model surface enhancements improved the symmetry of the transition front for quiet flow but made only slight differences for noisy flow. In quiet flow, the impact of streamwise positioning on transition was more significant on the model shoulders compared to the central region. The difference in the shoulder heating was likely due to variation in noise radiated from the nozzle sidewalls. The total temperature and initial wall temperatures were near 300 K and 293 K, respectively, which generally resulted in negative convective heat-flux values into the model. Hot-wire anemometry was also utilized to characterize the freestream and to conduct a planar survey near the base of the model for the 7.92 × 10 6 m −1 quiet condition. The survey captured the thickening of the boundary layer at the centerline and the vortical nature of the flow outboard of it. Spectral analysis of the mass-flux fluctuations near the midspan demonstrates that the boundary layer is laminar and suggests that the thick boundary layer caused the relatively warm centerline observed in the infrared images.

boundary layer transition↗

Preliminary Measurements on the BOLT Geometry in the Supersonic Low Disturbance Tunnel

Experiments were performed in the Mach 3.5 Supersonic Low Disturbance Tunnel on the BOundary-Layer Transition (BOLT) geometry. The goal of this campaign was to assess changes to the transition front by varying the freestream noise and the model surface quality. The model was printed of polycarbonate and is 30% scale of the flight geometry. It was tested under noisy and quiet conditions at different streamwise positions in the tunnel and was also tested before and after improvements were made to the model surface through sanding and gap reduction. Pitch and yaw angles were nominally zero. The model surface temperature was measured using infrared thermography and thermocouples as the unit Reynolds number was swept from 4.75 -- 15.8 x 10^6 m^{-1}. Boundary-layer transition was observed near the midspan of the model for unit Reynolds numbers above 10 x 10^6 m^{-1} in quiet flow, while transition was already observed on the shoulders below 5 x 10^6 m^{-1} in noisy flow. The model surface enhancements improved the symmetry of the transition front for quiet flow but made only slight differences for noisy flow. In quiet flow, the impact of streamwise positioning on transition was more significant on the model shoulders compared to the central region. The difference in the shoulder heating was likely due to variation in noise radiated from the nozzle sidewalls. The total temperature and initial wall temperatures were near 300 K and 293 K, respectively, which generally resulted in negative convective heat-flux values into the model. Hot-wire anemometry was also utilized to characterize the freestream and to conduct a planar survey near the base of the model for the 7.92 x 10^6 m^{-1} quiet condition. The survey captured the thickening of the boundary layer at the centerline and the vortical nature of the flow outboard of it. Spectral analysis of the mass-flux fluctuations near the midspan demonstrates that the boundary layer is laminar and suggests that the thick boundary layer caused the relatively warm centerline observed in the infrared images.

boundary layer transition↗

Implementation of an Experimental Setup Based on the Three-Omega Method for Thermal Conductivity Measurements of Molten Salts

Molten salt reactors (MSRs) are one of the most promising next-generation nuclear reactor designs which use molten salts as the fuel and coolant. To design, model, predict, license, and operate MSRs, the behavior of the fuel and coolant must be understood as a function of temperature and irradiation, i.e., burnup. Of particular importance and complexity is the reliable and reproducible measurement of thermal conductivity of molten salts at high temperatures (> 500 °C). Thermal conductivity provides information on the rate at which heat passes through a specified material and is dependent on chemical composition. Currently, in the national laboratory complex, several methods for measuring thermal conductivity on molten salt systems are under development, however, to date, consistent data have not been produced. Typically, thermal conductivity measurements of high-temperature melts have been conducted by using the Transient Hot Wire (THW) method where thermal conductivity is determined by the change in temperature over time at a certain distance from a heating wire. Another time-dependent technique is the laser flash method, commonly used for solid samples. Laser flash requires prior measurements of density and heat capacity to calculate the thermal conductivity of the sample, introducing additional measurement errors. Steady state and time-dependent measurements such as THW and laser flash have errors from convection and ambient temperature fluctuations (heat radiation). In order to produce high fidelity thermal conductivity data, a measurement technique needs to be developed that will reduce the effect of convection at high temperatures by measuring in a very fast time window. In addition, to measure on actinide and irradiated salts the sample size should be small. Therefore, this project aims to develop a frequency-domain technique based on the three-omega (3?) method, previously proven to work on solids, nanofluids and low temperature solar salts (25 to 250 °C). If the 3?-device can be designed with materials that can withstand high temperatures (>500 °C) and can be configured to reduce errors due to convection, then it would prove to be a valuable technique for ensuring thermal conductivity on molten salt systems needed for MSR development. For this proposal, the 3? instrument will be designed, assembled, and tested on non-radioactive salts before being used on actinide bearing salts. In addition, a thermal model will be developed to determine the thermal conductivity of the sample from the measured thermal oscillation of the sensor. Because 3? is a direct method that requires a small volume of sample and works in a very fast time window, it will aid in suppressing the interference due to convection which is ideal when working with high temperature liquid samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the recording of turbulent longitudinal and transverse fluctuations

A thorough understanding of the turbulent flow movements cannot be arrived at from investigations of the temporal mean values of the flows alone. Study of the fluctuation phenomena themselves is indispensable. Thus turbulence research entered a new promising stage when investigators started performing fluctuation measurements and basing theories on those measurements. The investigations of fluctuations carried out so far refer almost exclusively to the so-called isotropic turbulence. It represents a damping phenomenon; it is the simplest type of turbulence where merely the longitudinal fluctuations need to be measured. However, it is precisely nonisotropic turbulence which involves the most essential problem of the turbulent exchange movement and the turbulent apparent friction. Investigation of nonisotropic turbulence requires measurement of longitudinal and transverse fluctuations.

TURBULENCE MEASURING APPARATUS, HOT-WIRE↗

An inert gas purity tester

Hot titanium wire measurement of rare gas purity in glove boxes for alkali metal operations

HOT-WIRE MEASUREMENT↗

New devices for flow measurements: Hot film and burial wire sensors, infrared imagery, liquid crystal, and piezo-electric model

An experimental program aimed at identifying areas in low speed aerodynamic research where infrared imaging systems can make significant contributions is discussed. Implementing a new technique, a long electrically heated wire was placed across a laminar flow. By measuring the temperature distribution along the wire with the IR imaging camera, the flow behavior was identified.

Mcree, Griffith J., Jr.↗

Simple, Lightweight, Thermomechanical Coupling

Self-actuating thermal coupling device is light, and transfers heat efficiently. Coupling is thermostatic, making contact as necessary to maintain nearly steady temperature at hot side of interface. Hot pins on hot plate poised near cold pins on cold-plate. As temperature of hot plate rises, shape-memory wire contracts, drawing hot pin against cold pin. When temperature falls below critical level, wire expands, allowing hot pin to pull away. Critical temperature determined by composition of alloy.

Milam, M. Bruce↗

Mechanical properties and microstructure of 316L stainless steel produced by hybrid manufacturing

Hybrid manufacturing is a combination of additive (deposition) and subtractive (machining) manufacturing in a single machine tool. Such a system can be used for near net shape manufacturing and component repair using either similar or dissimilar materials. Integrated into a single system, transition between additive and subtractive manufacturing can occur immediately and be leveraged to generate large components by alternating between the processes. In this investigation, we show how the interleaved capabilities can reduce overall cycle time by up to 68 %, improve average relative elongation to failure by 71 %, and reduce the average relative porosity fraction by 83 % when compared to traditional additive manufactured components. Results from this investigation builds the foundation needed for hybrid manufacturing to be applicable towards the manufacture of large complex components such as nosecones and marine propulsors.

36 MATERIALS SCIENCE↗

Evaluation of the time dependent surface shear stress in turbulent flows

The time dependent surface shear stress has been evaluated using surface heat transfer measurements. For fully developed turbulent pipe and open channel water flows, and incompressible and compressible turbulent boundary layer air flows the measurements indicate the absolute magnitude of the surface shear stress fluctuations will be greater than two times the mean values. The root-mean-square shear stress fluctuations were of the order of 0.2 to 0.4 times the mean surface shear values. Due to these large surface shear stress fluctuations and the nonlinear relation between heat transfer and shear stress, a special technique has been developed to evaluate the measurements. It was found that the non-linear averaging errors for a hot film-surface shear stress gauge in a fully developed pipe flow was of the order of 10 percent at low velocities. A hot wire-surface shear stress gauge was employed for measurements of turbulent boundary layers in air.

Sandborn, V. A.↗

Properties of a half-delta wing vortex

The mean flow and turbulence structure of a single longitudinal vortex generated by a half-delta wing placed at a small angle of attack were investigated. Particular consideration was given to the near-field properties of the generator in order to establish the role of the generator wake in the initial rolling-up of the vortex, as well as to the far-field properties so that the approach to equilibrium could be studied. Measurements were made on fine cross-plane grids at seven streamwise locations using hot cross wires. The results show that the point of maximum vorticity and the generator wake do not merge until a streamwise distance equivalent to three generator heights is reached. Comparison with previous data on vortices produced by double-branched generators confirmed that the present vortex had achieved a fully developed state, and at a relatively short streamwise distance.

Mehta, Rabindra D.↗

An "Inefficient Fin" Non-Dimensional Parameter to Measure Gas Temperatures Efficiently

A gas containment vessel that is not in thermal equilibrium with the bulk gas can affect its temperature measurement. The physical nature of many gas dynamics experiments often makes the accurate measurement of temperature a challenge. The environment itself typically requires that the thermocouple be sheathed, both to protect the wires and hot junction of the instrument from their environment, and to provide a smooth, rigid surface for pressure sealing of the enclosure. However, that enclosure may also be much colder than the gas to be sensed, or vice-versa. Either way, the effect of such gradients is to potentially skew the temperature measurements themselves, since heat may then be conducted by the instrument. Thermocouple designers traditionally address this problem by insulating the sheath from the thermocouple leads and hot junction as much as possible. The thermocouple leads are typically packed in a ceramic powder inside the sheath, protecting them somewhat from temperature gradients along the sheath, but there is no effective mechanism to shield the sheath from the enclosure body itself. Standard practice dictates that thermocouples be used in installations that do not present large thermal gradients along the probe. If this conduction dominates heat transfer near the tip of the probe, then temperature measurements may be expected to be skewed. While the same problem may be experienced in the measurement of temperature at various points within a solid in a gradient, it tends to be aggravated in the measurements of gas temperature, since heat transfer dependent on convection is often less efficient than conduction along the thermocouple. The proposed solution is an inefficient fin thermocouple probe. Conventional wisdom suggests that in many experiments where gas flows through an enclosure (e.g., flow in pipe, manifold, nozzle, etc.), the thermocouple be introduced flush to the surface, so as not to interfere with the flow. In practice, however, many such experiments take place where the flow is already turbulent, so that a protruding thermocouple probe has a negligible effect on the flow characteristics. The key question then becomes just how far into the flow should a thermocouple protrude in order to properly sense the gas temperature at that point. Modeling the thermocouple as an "inefficient fin" directly addresses this question. The appropriate assumptions in this case are: one-dimensional conduction along the fin; steady-state, constant, and homogeneous thermal conductivity; negligible radiation; and a uniform, constant heat transfer coefficient over the probe surface. It is noted that the nature of the ceramic-filled probe makes the key assumption of homogeneous thermal conductivity that much more conservative.

Lemieux, Patrick↗