Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high - contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

A New Crater Near Insight: Implications for Seismic Impact Detectability on Mars

A new 1.5 m diameter impact crater was discovered on Mars only ~40 km from the InSight lander. Context camera images constrained its formation between 21 February and 6 April 2019; follow-up High Resolution Imaging Science Experiment images resolved the crater. During this time period, three seismic events were identified in InSight data. We derive expected seismic signal characteristics and use them to evaluate each of the seismic events. However, none of them can definitively be associated with this source. Atmospheric perturbations are generally expected to be generated during impacts; however, in this case, no signal could be identified as related to the known impact. Using scaling relationships based on the terrestrial and lunar analogs and numerical modeling, we predict the amplitude, peak frequency, and duration of the seismic signal that would have emanated from this impact. The predicted amplitude falls near the lowest levels of the measured seismometer noise for the predicted frequency. Hence, it is not surprising this impact event was not positively identified in the seismic data. Finding this crater was a lucky event as its formation this close to InSight has a probability of only ~0.2, and the odds of capturing it in before and after images are extremely low. We revisit impact-seismic discriminators in light of real experience with a seismometer on the Martian surface. Using measured noise of the instrument, we revise our previous prediction of seismic impact detections downward, from ~a few to tens, to just ~2 per Earth year, still with an order of magnitude uncertainty.

I. J. Daubar↗

Navigation of the EPOXI Spacecraft to Comet Hartley 2

On November 4, 2010, the EPOXI spacecraft flew by the comet Hartley 2, marking the fourth time that a NASA spacecraft successfully captured high resolution images of a cometary nucleus. EPOXI is the extended mission of the Deep Impact mission, which delivered an impactor on comet Tempel-1 on July 4, 2005. EPOXI officially started in September 2007 and eventually took over 3 years of flight time and had 3 Earth gravity assists to achieve the proper encounter conditions. In the process, the mission was redesigned to accommodate a new comet as the target and changes in the trajectory to achieve better imaging conditions at encounter. Challenges in navigation of the spacecraft included precision targeting of several Earth flybys and the comet encounter, uncertainties in determining the ephemeris of the comet relative to the spacecraft, and the high accuracy trajectory knowledge needed to image the comet during the encounter. This paper presents an overview of the navigation process used for the mission.

Deep Impact (DI)↗

NASA Tech Briefs, October 2008

Topics covered include: Control Architecture for Robotic Agent Command and Sensing; Algorithm for Wavefront Sensing Using an Extended Scene; CO2 Sensors Based on Nanocrystalline SnO2 Doped with CuO; Improved Airborne System for Sensing Wildfires; VHF Wide-Band, Dual-Polarization Microstrip-Patch Antenna; Onboard Data Processor for Change-Detection Radar Imaging; Using LDPC Code Constraints to Aid Recovery of Symbol Timing; System for Measuring Flexing of a Large Spaceborne Structure; Integrated Formation Optical Communication and Estimation System; Making Superconducting Welds between Superconducting Wires; Method for Thermal Spraying of Coatings Using Resonant-Pulsed Combustion; Coating Reduces Ice Adhesion; Hybrid Multifoil Aerogel Thermal Insulation; SHINE Virtual Machine Model for In-flight Updates of Critical Mission Software; Mars Image Collection Mosaic Builder; Providing Internet Access to High-Resolution Mars Images; Providing Internet Access to High-Resolution Lunar Images; Expressions Module for the Satellite Orbit Analysis Program Virtual Satellite; Small-Body Extensions for the Satellite Orbit Analysis Program (SOAP); Scripting Module for the Satellite Orbit Analysis Program (SOAP); XML-Based SHINE Knowledge Base Interchange Language; Core Technical Capability Laboratory Management System; MRO SOW Daily Script; Tool for Inspecting Alignment of Twinaxial Connectors; An ATP System for Deep-Space Optical Communication; Polar Traverse Rover Instrument; Expert System Control of Plant Growth in an Enclosed Space; Detecting Phycocyanin-Pigmented Microbes in Reflected Light; DMAC and NMP as Electrolyte Additives for Li-Ion Cells; Mass Spectrometer Containing Multiple Fixed Collectors; Waveguide Harmonic Generator for the SIM; Whispering Gallery Mode Resonator with Orthogonally Reconfigurable Filter Function; Stable Calibration of Raman Lidar Water-Vapor Measurements; Bimaterial Thermal Compensators for WGM Resonators; Root Source Analysis/ValuStream[Trade Mark] - A Methodology for Identifying and Managing Risks; Ensemble: an Architecture for Mission-Operations Software; Object Recognition Using Feature-and Color-Based Methods; On-Orbit Multi-Field Wavefront Control with a Kalman Filter; and The Interplanetary Overlay Networking Protocol Accelerator.

Source record↗

VLA Imaging of Protoplanetary Environments

We continue to use the Very Large Array (VLA) of the National Radio Astronomy Observatories (NRAO) to make high resolution images of thermal emission in the protoplanetary environment of nearby young stars. The VLA provides two unique capabilities. First, the angular resolution for imaging thermal emission is unmatched by any other facility. For the A array, the synthesized beam at a wavelength of 7 mm corresponds to a linear scale similar to the orbital radius of Jupiter at the distance of nearby dark clouds Eke Taurus. Second, the long millimeter wavelengths accessible to the VLA are particularly advantageous at this high resolution since the emission is (almost) entirely optically thin and probes the full disk column, including the innermost regions that remain opaque to shorter wavelengths.

Wilner, David J.↗

Mars: Compositional variability of ferric/ferrous minerals and polar volatiles from groundbased imaging spectroscopy

In an attempt to further constrain the ferric and ferrous mineralogy of Mars, Bell et al. (1989; 1990) obtained high resolution imaging spectroscopic data of much of the Martian surface in the visible and near-infrared (0.4-1.1 micron) during the 1988 opposition. Preliminary analysis of these data showed further evidence of crystalline hematite absorption features at 0.8-0.9 microns and 0.6-0.7 microns. Additionally, the 0.6-0.7 micron Fe(III) band was shown to vary across the surface, with a substantial correlation with albedo in the region studied. Calibration of this 1988 data set (along with a similar data set obtained during the 1990 opposition) has been ongoing, and some of the most recent results of the analysis of these data using linear spectral mixture modeling are reported.

Bell, James F., III↗

Windy Mars: A Dynamic Planet as Seen by the HiRISE Camera

With a dynamic atmosphere and a large supply of particulate material, the surface of Mars is heavily influenced by wind-driven, or aeolian, processes. The High Resolution Imaging Science Experiment (HiRISE) camera on the Mars Reconnaissance Orbiter (MRO) provides a new view of Martian geology, with the ability to see decimeter-size features. Current sand movement, and evidence for recent bedform development, is observed. Dunes and ripples generally exhibit complex surfaces down to the limits of resolution. Yardangs have diverse textures, with some being massive at HiRISE scale, others having horizontal and cross-cutting layers of variable character, and some exhibiting blocky and polygonal morphologies. 'Reticulate' (fine polygonal texture) bedforms are ubiquitous in the thick mantle at the highest elevations.

Mars↗

High speed PLIF study of the Richtmyer–Meshkov instability upon re-shock

The Richtmyer–Meshkov instability (RMI) of a twice-shocked gas interface is researched using high-speed planar-laser induced fluorescence (PLIF) in the Wisconsin Shock Tube Laboratory’s vertical shock tube. The initial condition (IC) is a shear layer with broadband diffuse perturbations at the interface between a helium-acetone mixture and argon. This IC is accelerated by a shock of nominal strength M = 1.8, and then accelerated again by the transmitted shock that reflects off the end wall of the tube. An estimate of the light gas mole fraction is extracted from high-speed imaging using an iterative process that accounts for the nonlinear temperature dependence of the acetone’s fluorescence quantum yield (FQY) and absorption cross-section. A vorticity deposition model for the initial growth rate after reshock is compared with the Mikaelian model for re-shock. Previously used in literature, the number of generations is shown to naturally arise from a normalisation of the scalar transport equation. A self-similar analysis is then further performed using the mole fraction data to explore the evolution of the RMI after reshock and the higher order moments of the light gas mole fraction are compared with a proposed model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

Clementine High Resolution Camera Mosaicking Project

This report constitutes the final report for NASA Contract NASW-5054. This project processed Clementine I high resolution images of the Moon, mosaicked these images together, and created a 22-disk set of compact disk read-only memory (CD-ROM) volumes. The mosaics were produced through semi-automated registration and calibration of the high resolution (HiRes) camera's data against the geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic produced by the US Geological Survey (USGS). The HiRes mosaics were compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution nadir-looking observations. The images were spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel for sub-polar mosaics (below 80 deg. latitude) and using the stereographic projection at a scale of 30 m/pixel for polar mosaics. Only images with emission angles less than approximately 50 were used. Images from non-mapping cross-track slews, which tended to have large SPICE errors, were generally omitted. The locations of the resulting image population were found to be offset from the UV/Vis basemap by up to 13 km (0.4 deg.). Geometric control was taken from the 100 m/pixel global and 150 m/pixel polar USGS Clementine Basemap Mosaics compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Radiometric calibration was achieved by removing the image nonuniformity dominated by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap, that approximately transform the 8-bit HiRes data to photometric units. The sub-polar mosaics are divided into tiles that cover approximately 1.75 deg. of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. Polar mosaics are tiled into squares 2250 pixels on a side, which spans approximately 2.2 deg. Two mosaics are provided for each pole: one corresponding to data acquired while periapsis was in the south, the other while periapsis was in the north. The CD-ROMs also contain ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files.

Source record↗

High signal-to-noise ratio differential conductance spectroscopy

The scanning tunneling microscope (STM) has enabled manipulation and interrogation of surfaces with atomic-scale resolution. Electronic information about a surface is obtained by combining the imaging capability of the STM with scanning tunneling spectroscopy, i.e., measurement of current-voltage (I/V) characteristics of the surface. We propose a change in the STM feedback loop that enables capturing a higher quality dI/dV image. A high frequency dither voltage is added to the bias voltage of the sample, and the fundamental frequency component of the resulting current is demodulated. The in-phase component of this signal is then plotted along with the X and Y position data, constructing the dI/dV image. Here, we show that by incorporating notch filters in the STM feedback loop, we may utilize a high-amplitude dither voltage to significantly improve the quality of the obtained dI/dV image.

42 ENGINEERING↗

Mapping Competitive Reduction upon Charging in LiNi 0.8 Co 0.15 Al 0.05 O 2 Primary Particles

Side reactions involving surface reduction play a critical role in the failure of LiNi 0.8 Co 0.15 Al 0.05 O 2 to reach its theoretical capacity as a cathode material for Li-ion batteries. While macroscopic consequences are known, the underlying nanoscopic mechanisms are not fully elucidated. By coupling X-ray spectroscopy with several X-ray microscopy modalities, we have spatially resolved the extent of Ni oxidation at several states of charge and uncovered heterogeneity that is hidden when considering ensemble measurements alone. The use of morphologically controlled particles enabled high-resolution imaging of these materials, uncovering gradients of Ni oxidation states within individual primary particles. At high states of charge, these gradients revealed regions of possible oxygen deficiency extending deeper into the particle than previously observed. Surface-sensitive X-ray coupled scanning tunneling microscopy allows oxidation states to be measured at the material's surface, showing predominantly Ni II in the first atomic layer and mixtures of Ni II with Ni III /Ni IV already appearing 1.5 nm into the particle. These results reveal the subtle interplay between irreversible surface transformations and the bulk reactions that ultimately define function, which will refine strategies of surface passivation that are key to overcoming current performance limitations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent Neutrino Cross-section Results from MicroBooNE

MicroBooNE is a liquid argon time projection chamber that operates in the Booster Neutrino Beam at Fermilab. The detector provides high-resolution imaging of neutrino interactions with a low threshold and full angular coverage. Thanks to a high event rate and several years of continuous operation, the MicroBooNE collaboration has obtained the world’s largest dataset of neutrino-argon scattering events. A detailed understanding of these interactions, especially the impact of nuclear physics effects, will be critical to the success of future precision neutrino oscillation efforts, particularly the argon-based Deep Underground Neutrino Experiment (DUNE) and the Short-Baseline Neutrino (SBN) program. This talk presents an overview of the latest neutrino-argon cross section measurements in MicroBooNE, including measurements of protons produced in muon neutrino interactions, measurements of the electron neutrino inclusive cross section, and progress towards measurements of rare channels.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SIRTF - Capabilities for planetary science

Major research areas of the Space Infrared Telescope Facility (SIRTF) are discussed which include Kuiper-belt comets, IR spectroscopy of comets, and circumstellar planetary debris disks. SIRTF instrumentation will include the infrared array camera (IRAC) and multiband imaging photometer (MIP). The IRAC uses large area, 2D infrared array detectors to provide wide-field (7 arcmin) and diffraction-limited imaging over the spectral region from 2 to 30 microns. The MIP will provide background-limited imaging and photometry over the wavelength range from 30 to 200 microns, wide-field, high resolution imaging from 50 to 120 microns, and broad band photometry and mapping from 200 to 700 microns.

Cruikshank, D. P.↗

Wavelet Compression of Satellite-Transmitted Digital Mammograms

Breast cancer is one of the major causes of cancer death in women in the United States. The most effective way to treat breast cancer is to detect it at an early stage by screening patients periodically. Conventional film-screening mammography uses X-ray films which are effective in detecting early abnormalities of the breast. Direct digital mammography has the potential to improve the image quality and to take advantages of convenient storage, efficient transmission, and powerful computer-aided diagnosis, etc. One effective alternative to direct digital imaging is secondary digitization of X-ray films. This technique may not provide as high an image quality as the direct digital approach, but definitely have other advantages inherent to digital images. One of them is the usage of satellite-transmission technique for transferring digital mammograms between a remote image-acquisition site and a central image-reading site. This technique can benefit a large population of women who reside in remote areas where major screening and diagnosing facilities are not available. The NASA-Lewis Research Center (LeRC), in collaboration with the Cleveland Clinic Foundation (CCF), has begun a pilot study to investigate the application of the Advanced Communications Technology Satellite (ACTS) network to telemammography. The bandwidth of the T1 transmission is limited (1.544 Mbps) while the size of a mammographic image is huge. It takes a long time to transmit a single mammogram. For example, a mammogram of 4k by 4k pixels with 16 bits per pixel needs more than 4 minutes to transmit. Four images for a typical screening exam would take more than 16 minutes. This is too long a time period for a convenient screening. Consequently, compression is necessary for making satellite-transmission of mammographic images practically possible. The Wavelet Research Group of the Department of Electrical Engineering at The Ohio State University (OSU) participated in the LeRC-CCF collaboration by providing advanced compression technology using wavelet transform. OSU developed a time-efficient software package with various wavelets to compress a serious of mammographic images. This documents reports the result of the compression activities.

Zheng, Yuan F.↗

The X-Ray Surveyor Mission: A Concept Study

NASA's Chandra X-ray Observatory continues to provide an unparalleled means for exploring the high-energy universe. With its half-arcsecond angular resolution, Chandra studies have deepened our understanding of galaxy clusters, active galactic nuclei, galaxies, supernova remnants, neutron stars, black holes, and solar system objects. As we look beyond Chandra, it is clear that comparable or even better angular resolution with greatly increased photon throughput is essential to address ever more demanding science questions-such as the formation and growth of black hole seeds at very high redshifts; the emergence of the first galaxy groups; and details of feedback over a large range of scales from galaxies to galaxy clusters. Recently, we initiated a concept study for such a mission, dubbed X-ray Surveyor. The X-ray Surveyor strawman payload is comprised of a high-resolution mirror assembly and an instrument set, which may include an X-ray microcalorimeter, a high-definition imager, and a dispersive grating spectrometer and its readout. The mirror assembly will consist of highly nested, thin, grazing-incidence mirrors, for which a number of technical approaches are currently under development-including adjustable X-ray optics, differential deposition, and new polishing techniques applied to a variety of substrates. This study benefits from previous studies of large missions carried out over the past two decades and, in most areas, points to mission requirements no more stringent than those of Chandra.

Astronomy↗

Milli-Arcsecond (MAS) Imaging with SmallSat Enabled Super-resolution

The objective of this project is to demonstrate a new imaging technology with unprecedented capabilities for scientific exploration. This technology innovation will enable extremely high-resolution imaging capability, otherwise unattainable with conventional approaches. It is based on a unique combination of novel diffractive optical sensing (photon sieve), advanced image processing, and small satellite formation flying. The spatial resolution of current solar instruments are more than 100 times coarser than the size of energy dissipation features in coronal heating (<100 km) since conventional optics cannot be figured to near diffraction-limited accuracy at extreme ultraviolet (EUV) wavelengths. This project will demonstrate the feasibility of imaging of a few milli-arcseconds (MAS) to study the structure and development of these dissipation regions.

Farzad Kamalabadi↗

In situ characterization of laser-generated melt pools using synchronized ultrasound and high-speed X-ray imaging

Metal additive manufacturing is a fabrication method that forms a part by fusing layers of powder to one another. An energy source, such as a laser, is commonly used to heat the metal powder sufficiently to cause a molten pool to form, which is known as the melt pool. The melt pool can exist in the conduction or the keyhole mode where the material begins to rapidly evaporate. The interaction between the laser and the material is physically complex and difficult to predict or measure. Here, high-speed X-ray imaging was combined with immersion ultrasound to obtain synchronized measurements of stationary laser-generated melt pools. Furthermore, two-dimensional and three-dimensional finite-element simulations were conducted to help explain the ultrasonic response in the experiments. In particular, the time-of-flight and amplitude in pulse-echo configuration were observed to have a linear relationship to the depth of the melt pool. These results are promising for the use of ultrasound to characterize the melt pool behavior and for finite-element simulations to aid in interpretation.

42 ENGINEERING↗

Revealing melt flow instabilities in laser powder bed fusion additive manufacturing of aluminum alloy via in-situ high-speed X-ray imaging

Laser metal additive manufacturing technologies enable the fabrication of geometrically and compositionally complex parts unachievable by conventional manufacturing methods. However, the certification and qualification of additively manufactured parts are greatly hindered by the stochastic melt flow instabilities intrinsic to the process, which has not been explicitly revealed by direct observation. Here, we report the mechanisms of the melt flow instabilities in laser powder bed fusion additive manufacturing process revealed by in-situ high-speed high-resolution synchrotron X-ray imaging. Here we identified powder/droplet impact, significant keyhole oscillation, and melting-mode switching as three major mechanisms for causing melt flow instabilities. We demonstrated the detrimental consequences of these instabilities brought to the process, and presented new understanding on the melt flow evolution and keyhole oscillation. This work provides critical insights into process instabilities during laser metal additive manufacturing, which may guide the development of instability mitigation approaches. The results reported here are also important for the development and validation of high-fidelity computational models.

36 MATERIALS SCIENCE↗