Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Arkansas Residential Energy Code Field Study (Baseline Report)

A research project in the State of Arkansas identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in May 2015 and continued through October 2015. During this period, research teams visited 226 homes during various stages of construction, resulting in a substantial data set based on observations made directly in the field. Analysis of the data has led to a better understanding of the energy features present in homes, and indicates over $300,000 in potential annual savings to Arkansas homeowners that could result from increased code compliance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metal Hydride Compressor for High-Pressure (875 bar) Hydrogen Delivery

Metal hydride hydrogen compression utilizes a reversible heat-driven interaction of a hydride-forming metal alloy with hydrogen gas. This paper reports on the development of a laboratory scale two-stage Metal Hydride Compressor (MHC) system with a feed pressure of 150 bar delivering high purity H2 gas at outlet pressures up to 875 bar. Stage 1 and stage 2 AB 2 metal hydrides are identified based on experimental characterization of the pressure-composition-temperature (PCT) behavior of candidate materials. The selected metal hydrides are each combined with expanded natural graphite, increasing the thermal conductivity of the composites by an order of magnitude. These composites are integrated in two compressor beds with internal heat exchangers that alternate between hydrogenation and dehydrogenation cycles by thermally cycling between 20 °C and 150 °C. The prototype compressor achieved compression of hydrogen from 150 bar to 700 bar with an average flow rate of 33.6 g/hr.

08 HYDROGEN↗

Turbulent Magnetic Relaxation in Pulsar Wind Nebulae

We present a model for magnetic energy dissipation in a pulsar wind nebula. A better understanding of this process is required to assess the likelihood that certain astrophysical transients may be powered by the spin-down of a “millisecond magnetar.” Examples include superluminous supernovae, gamma-ray bursts, and anticipated electromagnetic counterparts to gravitational wave detections of binary neutron star coalescence. Our model leverages recent progress in the theory of turbulent magnetic relaxation to specify a dissipative closure of the stationary magnetohydrodynamic (MHD) wind equations, yielding predictions of the magnetic energy dissipation rate throughout the nebula. Synchrotron losses are self-consistently treated. To demonstrate the model’s efficacy, we show that it can reproduce many features of the Crab Nebula, including its expansion speed, radiative efficiency, peak photon energy, and mean magnetic field strength. Unlike ideal MHD models of the Crab (which lead to the so-called σ -problem), our model accounts for the transition from ultra to weakly magnetized plasma flow and for the associated heating of relativistic electrons. We discuss how the predicted heating rates may be utilized to improve upon models of particle transport and acceleration in pulsar wind nebulae. We also discuss implications for the Crab Nebula’s γ -ray flares, and point out potential modifications to models of astrophysical transients invoking the spin-down of a millisecond magnetar.

79 ASTRONOMY AND ASTROPHYSICS↗

Alcator C-Mod: Research in support of ITER and steps beyond

This paper presents an overview of recent highlights from research on Alcator C-Mod. Significant progress has been made across all research areas over the last two years, with particular emphasis on divertor physics and power handling, plasma-material-interaction studies, ELM-suppressed pedestal dynamics, core transport and turbulence, and RF heating and current drive utilizing Ion Cyclotron and Lower Hybrid tools. Specific results of particular relevance to ITER include: inner wall SOL transport studies that have led, together with results from other experiments, to the change of the detailed shape of the inner wall in ITER; runaway electron studies showing that the critical electric field required for runaway generation is much higher than predicted from collisional theory; core tungsten impurity transport studies reveal that tungsten accumulation is naturally avoided in typical C-Mod conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A modified Monte Carlo model for the ionospheric heating rates

A Monte Carlo method is adopted as a basis for the derivation of the photoelectron heat input into the ionospheric plasma. This approach is modified in an attempt to minimize the computation time. The heat input distributions are computed for arbitrarily small source elements that are spaced at distances apart corresponding to the photoelectron dissipation range. By means of a nonlinear interpolation procedure their individual heating rate distributions are utilized to produce synthetic ones that fill the gaps between the Monte Carlo generated distributions. By varying these gaps and the corresponding number of Monte Carlo runs the accuracy of the results is tested to verify the validity of this procedure. It is concluded that this model can reduce the computation time by more than a factor of three, thus improving the feasibility of including Monte Carlo calculations in self-consistent ionosphere models.

Mayr, H. G.↗

A modified Monte Carlo model for the ionospheric heating rates.

A Monte Carlo method is adopted as a basis for the derivation of the photoelectron-heat input into the ionospheric plasma. Since a great number of Monte Carlo runs are required normally for the computation of the heating rates, this approach is modified in an attempt to minimize the computation time. The heat-input distributions are computed for arbitrarily small source elements that are spaced apart at distances corresponding to the photoelectron dissipation range. By means of a nonlinear interpolation procedure their individual heating-rate distributions are utilized to produce synthetic ones that fill the gaps between the Monte Carlo generated distributions. By varying these gaps and the corresponding number of Monte Carlo runs the accuracy of the results is tested to verify the validity of this procedure. It is concluded that this model can reduce the computation time by as much as an order of magnitude, thus improving the feasibility of including Monte Carlo calculations in self-consistent ionosphere models.

Mayr, H. G.↗

Flat plate collector performance determined experimentally with a solar simulator

The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program being conducted at Lewis will provide the basis for selecting collectors for use at Langley. The technology program includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented herein.

Vernon, R. W.↗

Flat-plate collector performance determined experimentally with a solar simulator

The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program is described which includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented. The collector performance obtained with the solar simulator will be correlated with data obtained by conducting tests outdoors at Lewis.

Vernon, R. W.↗

Transparent materials processing system

A zero gravity processing furnace system was designed that will allow acquisition of photographic or other visual information while the sample is being processed. A low temperature (30 to 400 C) test model with a flat specimen heated by quartz-halide lamps was constructed. A high temperature (400 to 1000 C) test model heated by resistance heaters, utilizing a cylindrical specimen and optics, was also built. Each of the test models is discussed in detail. Recommendations are given.

Hetherington, J. S.↗

Installation package maxi-therm S-101 heating module

The installation, operation and maintenance of the Maxi-Therm S-101 Thermosypnon Heating Module is described. The Maxi-Therm S-101 is a packaged unit, complete with air filter, blower, electrical controls, and a thermosyphon liquid to air heat exchanger. It is intended for use in residential solar heating systems and can utilize off-peak electrical power.

Source record↗

Cogeneration Technology Alternatives Study (CTAS). Volume 1: Summary

Various advanced energy conversion systems that can use coal or coal-derived fuels for industrial cogeneration applications were compared to provide information needed by DOE to establish research and development funding priorities for advanced-technology systems that could significantly advance the use of coal or coal-derived fuels in industrial cogeneration. Steam turbines, diesel engines, open-cycle gas turbines, combined cycles, closed-cycle gas turbines, Stirling engines, phosphoric acid fuel cells, molten carbonate fuel cells, and thermionics were studied with technology advancements appropriate for the 1985-2000 time period. The various advanced systems were compared and evaluated for wide diversity of representative industrial plants on the basis of fuel energy savings, annual energy cost savings, emissions savings, and rate of return on investment as compared with purchasing electricity from a utility and providing process heat with an on-site boiler. Also included in the comparisons and evaluations are results extrapolated to the national level.

Barna, G. J.↗

Thermal vacuum performance testing of the Space Shuttle Orbiter radiator system

A space shuttle orbiter system thermal vacuum performance test was conducted at NASA-Johnson Space Center in Chamber A of the space environment simulation laboratory. The test of objective was to verify the radiator system heat rejection performance capability utilizing two development and two flight radiator panels comprising one of the two Orbiter Freon-21 coolant loops. Radiator performance over the range of expected flight conditions was as predicted, and there was no degradation of performance after extended vacuum exposure.

Behrend, A. F., Jr.↗

Thermionic Energy Conversion (TEC) topping thermoelectrics

Performance expectations for thermionic and thermoelectric energy conversion systems are reviewed. It is noted that internal radiation effects diminish thermoelectric figures of merit significantly at 1000 K and substantially at 2000 K; the effective thermal conductivity contribution of intrathermoelectric radiative dissipation increases with the third power of temperature. It is argued that a consideration of thermoelectric power generation with high temperature heat sources should include utilization of thermionic energy conversion (TEC) topping thermoelectrics. However TEC alone or TEC topping more efficient conversion systems like steam or gas turbines, combined cycles, or Stirling engines would be more desirable generally.

Morris, J. F.↗

The use of a thermal utility with space-platform-mounted instruments

A thermal utility is a high-capacity heat transport system that serves as a common, temperature-controlled heat sink or source to more than one payload. The feasibility of using a thermal utility for space-platform-mounted instruments which have a range of temperature level and heat rejection requirements is examined and significant design parameters are identified. A baseline, pumped, two-phase heat transport system has been defined for NASA's proposed Space Platform, and its capability to satisfy the thermal requirements of a range of multidisciplinary instruments has been assessed.

Almgren, D. W.↗

Structure and dynamics of monsoon depressions: The Monex depression (July 1979)

Literature on monsoon formation is surveyed. Monsoon depressions over the Bay of Bengal are caused either by amplification of westward propagating weak disturbances or by downward propagation of the internal jet instability of the easterly jet. Barotropic instability of low level flow helps the growth of weak disturbances. Rapid growth of an already existing weak perturbation is due to CISK. If the disturbance attains adequate amplitude in the lower levels (either by downward propagation of wave energy of by CISK), the low level moisture convergence and latent heat of condensation are utilized more efficiently for the development of a vertically coupled deep disturbance, which along with upper level easterlies contributes to the westward propagation of the disturbance. Absence of strong vertical coupling leads to vertical tilt and decay of the disturbance.

Shukla, J.↗