Results of experiments to simulate radiant heating of propellant in a nuclear light bulb engine using a D-C arc radiant energy source
Simulating radiant heating of propellant stream of nuclear light bulb engine
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Simulating radiant heating of propellant stream of nuclear light bulb engine
Residential homes and light commercial buildings usually require substantial heat and electricity simultaneously. A combined heat and power system enables more efficient and environmentally friendly energy usage than that achieved when heat and electricity are produced in separate processes. However, due to financial and space constraints, residential and light commercial buildings often limit the use of traditional large-scale industrial equipment. Here we develop a micro–combined heat and power system powered by an opposed-piston engine to simultaneously generate electricity and provide heat to residential homes or light commercial buildings. The developed prototype attains the maximum AC electrical efficiency of 35.2%. The electrical efficiency breaks the typical upper boundary of 30% for micro–combined heat and power systems using small internal combustion engines (i.e., <10 kW). Moreover, the developed prototype enables maximum combined electrical and thermal efficiencies greater than 93%. The prototype is optimally designed for natural gas but can also run renewable biogas and hydrogen, supporting the transition from current conventional fossil fuels to zero carbon emissions in the future. The analysis of the unit’s decarbonization and cost-saving potential indicate that, except for specific locations, the developed prototype might excel in achieving decarbonization and cost savings primarily in US northern and middle climate zones.
A crucial point for further development of engines is the optimization of its heat exchangers which operate under oscillatory flow conditions. It has been found that the most important thermodynamic uncertainties in the Stirling engine designs for space power are in the heat transfer between gas and metal in all engine components and in the pressure drop across the heat exchanger components. So far, performance codes cannot predict the power output of a Stirling engine reasonably enough if used for a wide variety of engines. Thus, there is a strong need for better performance codes. However, a performance code is not concerned with the details of the flow. This information must be provided externally. While analytical relationships exist for laminar oscillating flow, there has been hardly any information about transitional and turbulent oscillating flow, which could be introduced into the performance codes. In 1986, a survey by Seume and Simon revealed that most Stirling engine heat exchangers operate in the transitional and turbulent regime. Consequently, research has since focused on the unresolved issue of transitional and turbulent oscillating flow and heat transfer. Since 1988, the University of Minnesota oscillating flow facility has obtained experimental data about transitional and turbulent oscillating flow. However, since the experiments in this field are extremely difficult, lengthy, and expensive, it is advantageous to numerically simulate the flow and heat transfer accurately from first principles. Work done at the University of Minnesota on the development of such a numerical simulation is summarized.
A gaseous H2/O2 rocket engine was constructed at the NASA-Lewis to provide a high heat flux source representative of the heat flux to the blades in the high pressure fuel turbopump (HPFTP) during startup of the space shuttle main engines. The high heat flux source was required to evaluate the durability of thermal barrier coatings being investigated for use on these blades. The heat transfer, and specifically, the heat flux to tubes located at the throat of the test rocket engine was evaluated and compared to the heat flux to the blades in the HPFTP during engine startup. Gas temperatures, pressures and heat transfer coefficients in the test rocket engine were measured. Near surface metal temperatures below thin thermal barrier coatings were also measured at various angular orientations around the throat tube to indicate the angular dependence of the heat transfer coefficients. A finite difference model for a throat tube was developed and a thermal analysis was performed using the measured gas temperatures and the derived heat transfer coefficients to predict metal temperatures in the tube. Near surface metal temperatures of an uncoated throat tube were measured at the stagnation point and showed good agreement with temperatures predicted by the thermal model. The maximum heat flux to the throat tube was calculated and compared to that predicted for the leading edge of an HPFTP blade. It is shown that the heat flux to an uncooled throat tube is slightly greater than the heat flux to an HPFTP blade during engine startup.
Explore the source record for details and available documents.
A transient technique was used to measure heat transfer coefficients on stator airfoils in a high-temperature annular cascade at real engine conditions. The transient response of thin film thermocouples on the airfoil surface to step changes in the gas stream temperature was used to determine these coefficients. In addition, gardon gages and paired thermocouples were also utilized to measure heat flux on the airfoil pressure surface at steady state conditions. The tests were conducted at exit gas stream Reynolds numbers of one-half to 1.9 million based on true chord. The results from the transient technique show good comparison with the steady-state results in both trend and magnitude. In addition, comparison is made with the STAN5 boundary layer code and shows good comparison with the trends. However, the magnitude of the experimental data is consistently higher than the analysis.
A transient technique was used to measure heat transfer coefficients on stator airfoils in a high-temperature annular cascade at real engine conditions. The transient response of thin film thermocouples on the airfoil surface to step changes in the gas stream temperature was used to determine these coefficients. In addition, gardon gages and paired thermocouples were also utilized to measure heat flux on the airfoil pressure surface at steady state conditions. The tests were conducted at exit gas stream Reynolds numbers of one-half to 1.9 million based on true chord. The results from the transient technique show good comparison with the steady-state results in both trend and magnitude. In addition, comparison is made with the STAN5 boundary layer code and shows good comparison with the trends. However, the magnitude of the experimental data is consistently higher than the analysis.
The industries examined in this report primarily rely on moderate-temperature heat provided by gas- or coal-fired boilers and combined heat and power (CHP) plants, delivered through standard process steam systems. High-temperature energy demands are often industry-specific and typically exceed the capabilities of high-temperature gas-cooled reactors (HTGRs). While it is technically feasible to replace process steam from fossil-based heat sources with nuclear energy, certain industries, such as methanol production and pulp and paper, face technoeconomic challenges in integrating nuclear energy without major changes or a technological shift. This is mainly due to the limited external energy demand remaining after the use of internal byproducts, waste heat recovery, and simple efficiency improvements. Achieving full decarbonization of these processes with nuclear energy would require significant technological advancements, involving experimental technology and substantial investments, making widespread adoption in existing industrial plants unlikely in the near term. This study reviews TES options in the context of enabling a flexible CHP supply while maintaining a steady nuclear heat input. Heat storage systems that interface between the reactor primary fluid and the CHP system offer superior performance and flexibility. Specifically, steam extraction downstream of the reheater with a two-tank molten-salt TES appears as the best solution regarding thermodynamic system benefits and system drawbacks. Using selected system configurations, a conceptual design of an industrial energy park was developed for industries with varying energy demands, such as steel production plants utilizing electric arc furnaces (EAFs) and chemical plants, as well as for those with constant energy demands, like petroleum refineries. This design highlights the capabilities of TES and explores its potential business cases. The study also conceptually develops the potential for integrating additional energy sources with nuclear systems through the implementation of TES. The potential of the HTGR-TES-CHP system was also evaluated considering key uncertainties such as industrial demand profiles, external grid access availability, and eligible tax credit levels, using the Holistic Energy Resource Optimization Network. Sensitivity of net present value to these uncertainties was analyzed to determine the optimal number of nuclear reactors (and CHP systems) and the suitable TES capacity. The results were interpreted from a decision-maker’s perspective, focusing on three key areas: deployment strategy (oversized units vs. undersized units with TES support), industrial process characteristics (thermal-intensive single profiles vs. electricity-intensive combined profiles), and operational goals (maximizing profits vs. minimizing natural gas (NG) consumption or external grid dependence). The optimization results indicate that the HTGR-TES-CHP system significantly reduces reliance on NG boilers for individual industrial processes by 9-60% (in NG capacity factor), with an average reduction of 38%, compared to standalone NG boiler operation case (Business As Usual [BAU]). For combined industrial processes, the reduction ranges from 37-77%, with an average of 60%. Additionally, the system greatly reduces dependence on external grids. In meeting industrial electrical demands, a 33-100% self-sufficient internal electricity supply is achieved for single industrial process, with an average of 74%, compared to the BAU scenario, where 100% of electricity is imported. For combined processes, 35-100% of internal electricity demands are met by the reactor, with an average of 73%. At last, the relative NG price levels at which the proposed HTGR-TES-CHP system can cost-effectively enter the market currently dominated by existing NG boilers were estimated. For a moderate HTGR CAPEX level ($\$$2500/kWth, $\$$6329/kWe), the analysis suggests that NG prices must be 2.5 to 7 times higher than HTGR variable operating and maintenance costs for single industrial process, and 5.5 to 9.5 times higher for a combined process scenario. Tax credit modeling shows that the Investment Tax Credit significantly reduces the price threshold needed to break even, making the system competitive with NG boilers in certain cases.
Data obtained from an extensive investigation of the cooling characteristics of four multicylinder, liquid-cooled engines have been analyzed and a correlation of both the cylinder-head temperatures and the coolant heat rejections with the primary engine and coolant variables was obtained. The method of correlation was previously developed by the NACA from an analysis of the cooling processes involved in a liquid-cooled-engine cylinder and is based on the theory of nonboiling, forced-convection heat transfer. The data correlated included engine power outputs from 275 to 1860 brake horsepower; coolant flows from 50 to 320 gallons per minute; coolants varying in composition from 100 percent water to 97 percent ethylene glycol and 3 percent water; and ranges of engine speed, manifold pressure, carburetor-air temperature, fuel-air ratio, exhaust-gas pressure, ignition timing, and coolant temperature. The effect on engine cooling of scale formation on the coolant passages of the engine and of boiling of the coolant under various operating conditions is also discussed.
The Cummins SuperTruck II program has completed the planned technical work on the project. This work includes Demonstrating 50% BTE on the engine-only, 55% BTE for an engine with waste heat recovery, and 125% improvement in vehicle freight efficiency. The engine system included a high efficiency diesel engine integrated with a state-of-the-art waste heat recovery (WHR) system and an advanced aftertreatment system capable of meeting the current emissions standards.
This project with Cummins supports the development of next generation heavy duty diesel engines that can achieve a 50% or better Break Thermal Efficiency (BTE). The fuel efficiency roadmap for the 50% BTE engine considers six main areas for efficiency improvement in the baseline engine, several of which involve making more efficient use of thermal energy (heat) in the engine. Increased operating temperatures and improved thermal management are expected to enable significant increases in $power$ $density$, thus resulting in greater power output for the same sized engine or engine downsizing (or light weighting) for the same power output. However, it has become apparent that several key components will be exposed to temperatures beyond the capabilities of current engine and exhaust materials, requiring the availability of the next generation of high temperature materials to allow the engine to reach the targeted efficiencies, commercially viable durability, and emission targets. The objective of this project was to identify and/or develop key materials, and evaluate their critical properties to enable the design and development of a lightweight, higher efficiency engine, with enhanced temperature capability and reduced heat-loss to the atmosphere in order to facilitate waste heat recovery and improved efficiency. An increase in the temperature capability of exhaust manifold materials, and piston materials were identified as having a positive influence on the efficiency of the next generation diesel engines. Since the current materials (High SiMo cast irons used in exhaust manifolds, and 4140 steel in pistons) are already operating near their limits of their temperature and strength capabilities, it was determined that new materials with the right combination of properties are required for these components. Oxidation and constrained thermal fatigue tests were used to down-select CF8C plus (CF8CP), a cast austenitic stainless steel, for exhaust manifolds capable of operating at higher temperatures. A prototype exhaust manifold was fabricated using CF8CP and successfully tested in a marine engine. A functionally graded multiple-layer thermal barrier coating system was designed with four layers of mixed bondcoat alloy (NiCoCrAlYHfSi) and yttria stabilized zirconia (YSZ) and was shown to reduce the effective thermal conductivity of the coating-substrate (steel and Ti-6Al-4V) system. The graded alloy and YSZ mixture were intended to achieve better match of thermal expansion coefficient (CTE) and minimize thermal stresses. Such coatings can increase the temperature capability of pistons fabricated from steel and Ti-alloys. Effect of oil additives and friction conformal contact friction tests showed there was a 15-30% reduction in friction by the polymer-graphite composite coating compared to the uncoated steel piston. Standalone Mn-P coating had little beneficial impact. Changing the oil from CJ-4 to PC-11 had little impact on the friction behavior in boundary lubrication. Wear behavior was tested under a point contact configuration with a high contact pressure. The candidate CK-4 oil showed similar or slightly better lubricity compared to the CJ-4 oil while the candidate FA-4 oil decisively increased the piston skirt wear. Although both coatings prevented scuffing failure observed for the uncoated steel skirt in a base oil without an additive package, they surprisingly caused a higher piston wear rate when tested in any of the fully formulated engine oil. The detrimental impact was attributed to the Mn-P film, either as a standalone coating, or a coating interlayer. The porous and brittle Mn-P film was broken during the wear test and the released hard Mn-P grains are suspected to cause third-body abrasion to accelerate the wear process. This work also evaluated the feasibility of developing an improved high temperature, low mass, cost-neutral turbocharger compressor wheel for heavy-duty engine applications from TiAl using additive manufacturing, utilizing its unique ability to fabricate high strength, low weight structures. This work has shown that the phase transforming nature of the TiAl alloys enable obtaining equiaxed microstructures in the as-built state without the need for tedious beam parameter manipulations. The HIPed structures have good RT tensile properties that will enable them to be surface machined to the required tolerance that can 2 then be heat treated to obtain the desired microstructures. Additionally, the negligible residual stresses stemming from the high build chamber temperatures ensure the parts are formed without cracks (one of the major issues in traditional manufacturing of these intermetallics).
Report describes tests of dual-throat rocket engine burning hydrogen in oxygen. In tests, heat-flux profiles measured in inner nozzle and outer chamber. Dual-throat engine being considered for advanced space transportation. Consisting of two combustion chambers in series operating separately or together, engine makes it possible to change mode of operation in flight to obtain performance in most advantageous regime. Produces high thrust at sea level or low thrust with higher performance at high altitudes or in space.
This paper investigates the effects of implementing Heat Pipe Turbine Vane (HPTV) cooling in the NASA N+3 engine. The HPTV can be thought of as a heat pipe in the shape of a turbine vane, functioning as both an aerodynamic body and heat exchanger. The heat-absorbing section of the HPTV remains fixed in the vanes of the high pressure turbine (HPT), while the heat-rejecting section can be placed in any stage of the low pressure turbine (LPT) as well as the bypass stream. The optimal location of the condensing (heat-rejecting) section is shown to be in the bypass stream for both HPT stages. The thrust specific fuel consumption increased by 0.2%, which is mainly attributed to the elimination of air cooling in the second stage HPT vanes combined with the transfer of energy from the main gas path to elsewhere in the cycle. Air cooling is also eliminated in the first stage HPT vanes, but this cooling air is nonchargeable. A preliminary design is proposed and shown to demonstrate the desired performance and operates below all the heat flux limitations in the first stage HPT . The design in the second stage HPT exceeds a limiting phenomenon but is expected to be remedied by changing the working fluid.
Explore the source record for details and available documents.
Two dual-stream, heated jet, Compact Jet Engine Simulator (CJES) units are designed for wind tunnel acoustic experiments involving a Hybrid Wing Body (HWB) vehicle. The newly fabricated CJES units are characterized with a series of acoustic and flowfield investigations to ensure successful operation with minimal rig noise. To limit simulator size, consistent with a 5.8% HWB model, the CJES units adapt Ultra Compact Combustor (UCC) technology developed at the Air Force Research Laboratory. Stable and controllable operation of the combustor is demonstrated using passive swirl air injection and backpressuring of the combustion chamber. Combustion instability tones are eliminated using nonuniform flow conditioners in conjunction with upstream screens. Through proper flow conditioning, rig noise is reduced by more than 20 dB over a broad spectral range, but it is not completely eliminated at high frequencies. The low-noise chevron nozzle concept designed for the HWB test shows expected acoustic benefits when installed on the CJES unit, and consistency between CJES units is shown to be within 0.5 dB OASPL.
Diffusion analysis on radiant heat transfer from gaseous nuclear fuel container to annulus of flowing hydrogen
Heat and mass transfer characteristics of axial- flow liquid-core nuclear rocket engine employing radiation heat transfer
A method of operating a vehicle including an engine, a transmission, an exhaust gas heat recovery (EGHR) heat exchanger, and an oil-to-water heat exchanger providing selective heat-exchange communication between the engine and transmission. The method includes controlling a two-way valve, which is configured to be set to one of an engine position and a transmission position. The engine position allows heat-exchange communication between the EGHR heat exchanger and the engine, but does not allow heat-exchange communication between the EGHR heat exchanger and the oil-to-water heat exchanger. The transmission position allows heat-exchange communication between the EGHR heat exchanger, the oil-to-water heat exchanger, and the engine. The method also includes monitoring an ambient air temperature and comparing the monitored ambient air temperature to a predetermined cold ambient temperature. If the monitored ambient air temperature is greater than the predetermined cold ambient temperature, the two-way valve is set to the transmission position.