Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

DEEP Solar: Data DrivEn Modeling and Analytics for Enhanced System Layer ImPlementation

Realizing the SETO 2030 mission of reducing solar energy costs to 3-5 c/kWh will require innovative enabling research on effective, cost-efficient integration of local PV within distribution systems. However, the intermittent and variable nature of PVs compels operators to impose conservative hosting capacity constraints. Given the extremely high variability of (intermittent and unpredictable) solar energy generation, relaxing the capacity constraints (which are currently around 15%) and achieving 100% or greater integration of renewables will require a fundamental transformation of the power grid via the utilization of exponentially larger amounts of AMI enabled fine-grained data. To address the challenges in increasing the penetration of renewable energy based DERs, this project envisions an Enhanced System Layer (ESL) at the distribution network level that is reliable, cost-effective and scalable to millions of Distributed Energy Resources (DERs)/devices. This includes developing: 1) Transformative and highly scalable machine learning based predictive analytics tools that plug into distribution system planning and provide real-time situational awareness at the distribution level for short and long-term operational planning. The tools will be built using novel data-driven energy models of millions of active nodes with AMI, 2) Adaptive stochastic analysis and optimization algorithms for real-time grid operations, 3) Dynamic Scenario Analysis using parallel Cloudenabled implementations with < 1 minute computational cycle times.

14 SOLAR ENERGY↗

A Simple and Accurate Energy-Detector-Based Transient Waveform Detection for Smart Grids: Real-World Field Data Performance

Integration of distributed energy sources, advanced meshed operation, sensors, automation, and communication networks all contribute to autonomous operations and decision-making processes utilized in the grid. Therefore, smart grid systems require sophisticated supporting structures. Furthermore, rapid detection and identification of disturbances and transients are a necessary first step towards situationally aware smart grid systems. This way, high-level monitoring is achieved and the entire system kept operational. Even though smart grid systems are unavoidably sophisticated, low-complexity algorithms need to be developed for real-time sensing on the edge and online applications to alert stakeholders in the event of an anomaly. In this study, the simplest form of anomaly detection mechanism in the absence of any a priori knowledge, namely, the energy detector (also known as radiometer in the field of wireless communications and signal processing), is investigated as a triggering mechanism, which may include automated alerts and notifications for grid anomalies. In contrast to the mainstream literature, it does not rely on transform domain tools; therefore, utmost design and implementation simplicity are attained. Performance results of the proposed energy detector algorithm are validated by real power system data obtained from the DOE/EPRI National Database of power system events and the Grid Signature Library.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Best Practices for Resilience in Smart Grid-Interactive Efficient Buildings

The Federal Energy Management Program (FEMP) supports federal agencies' energy decisions with information and guidance on design, funding, and operations to ensure federal buildings are efficient and resilient. The modernization of building infrastructure and the evolution of buildings to support decarbonization involves complex implementation of multiple components across several systems. This includes energy-efficient equipment, on-site energy generation and storage systems, and control systems. These systems have operational modes that can operate more efficiently if they are able to behave responsively to the conditions of the electrical grid. These grid-interactive efficient buildings (GEB) allow facilities to manage power demand according to operational constraints and market signals issued by grid operators. With proper design and planning, these same capabilities have the potential to enable building and facility resilience - coordinating with microgrids, maintaining power on critical circuits to sustain essential operations, and monitoring building health and safety status during an outage. By managing the load of buildings, GEBs can also reduce the cost of backup generation and make better use of renewable power sources on site. This document outlines some of the processes and considerations to guide the design and operation of GEBs in ways that promote facility resilience.

building decarbonization↗

Mathematical Models for Optimization of Grid-Integrated Energy Storage Systems

Energy storage has been proven to yield positive effects on planning, operation and control of electric grids. It has become a crucial task to properly model the energy storage systems (ESS) under the framework of grid optimization on transmission and distribution networks including microgrids. This paper presents a review on mathematical models and test cases of ESSs used for grid optimization studies, where the network constraints of power systems are included. The existing ESS models are mainly classified into two categories – linear and nonlinear models. The two main categories are further divided into several subcategories respectively; such as mixed-integer linear and convex nonlinear sub-categories. Based on the review and discussions, this paper aims at providing suggestions for choosing proper ESS models for specific grid optimization studies considering the chosen power network model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large Angle Deviation in Grid-Following IBRs Upon Grid Voltage Dip

In the 2021 Texas Odessa large-scale solar PV tripping events, phase-locked-loop (PLL) loss of synchronism is identified as a major cause of solar PV tripping. When solar PVs detected a large phase angle deviation (e.g., 10 degrees), tripping commands were initiated. Here, the large phase angle deviation was triggered by a transmission line fault 200 miles away, which in turn led to approximately 30% voltage drop in the 345-kV system. This paper offers a plausible reason why grid-following inverter-based resources (IBRs) may experience a large angle deviation upon grid voltage dip. Critical operating conditions contributing to such phenomena are identified via analysis and their effects are demonstrated using electromagnetic transient (EMT) simulation. Furthermore, the effect of converter control, e.g., grid-following control vs. grid-forming control, is examined. It is found from EMT simulation results that frequency and voltage control are helpful in mitigating angle deviation. Furthermore, linear block diagrams are derived to examine why frequency control can effectively suppress large angle deviation.

14 SOLAR ENERGY↗

Modeling Flow and Particle Deposition in a Spent Nuclear Fuel Assembly

CFD (Computational Fluid Dynamic) simulation of aerosol-laden natural convective flow and particle deposition in a spent fuel storage canister with 37 assemblies is currently computationally prohibitive. PWR (Pressurized Water Reactor) assemblies have up to 289 pins or tubes with several spacer grids to align the pins. Spacer grids with mixing vanes induce swirling during operation to increase heat transfer. Each spacer grid contains hundreds of small structures such as retaining clips, channel walls, and openings. The largest canisters store 37 PWR assemblies thus, there are numerous pins, tubes, and spacer grids for which the flow region between and around these structures needs to be determined along with the movement and deposition of aerosol particles. Because of the complicated geometry, modeling the intricate flow even for just one assembly is currently impractical. Nonetheless, we are developing techniques for a practical model to assess the natural aerosol particle deposition process in a canister in the event that a release occurs from one or more fuel pins. In the previous work it was demonstrated that CFD can model the flow through a PWR spacer grid with mixing vanes, including particle deposition, in a reasonable amount of time on a personal computer. In this work, the analysis is extended to include the bypass region between an assembly and the canister basket walls. It is shown that the flow velocity in the bypass region is about three times that of the interstitial region between the pins. The lengths before and after the spacer grid are also extended to determine when the flow becomes fully developed. In addition, the approach of computationally “stitching together” segments of an assembly is demonstrated with the plan to ultimately model a full assembly. The fraction of particles that are deposited in a segment with a spacer grid is determined as a function of particle size and flow velocity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Energy consumption and charging load profiles from long-haul truck electrification in the United States

Abstract The urgent need to decarbonize the transportation sector combined with falling battery prices has spurred industry and policy interest in long-haul truck electrification. The charging behavior and resulting loads from electrified long-haul freight trucks are crucial for the smooth operation of the electric grid and have far-reaching environmental impacts (e.g., greenhouse gas and other air pollutant emissions). However, the aggregate energy impact of a fleetwide shift to electrified long-haul freight trucking has not been explored. This study combines electric truck design scenarios, bottom-up truck weight modeling, vehicle energy modeling, large-scale truck traffic data, and simulation of likely operation and charging behaviors to estimate end-use energy consumption and location-specific hourly charging loads for a national fleet of long-haul electric trucks. Relative to a fleet of future diesel trucks, electrification would reduce direct end-use energy consumption by 0.9 × 10 18 J (0.9 quadrillion BTU), but electrification might increase life cycle energy consumption depending on the electricity source. The electricity required to charge long-haul electric trucks is equivalent to five percent of annual electricity consumption in the United States (US). The simulated truck charging loads peak during the day across the US grid regions, but the charging peaks’ exact timing is sensitive to when trucks are dispatched for operation. The load shapes suggest that electric trucks’ charging loads can coincide with peaks in solar power generation, and planning could enable on- or off-site integration between truck charging stations and renewable electricity generation.

Tong, Fan (ORCID:0000000346613956)↗

Form EIA-923 Data

Form EIA-930 data collection provides a centralized and comprehensive source for hourly operating data about the high-voltage bulk electric power grid in the Lower 48 states. We collect the data from the electricity balancing authorities (BAs) that operate the grid.

17 WIND ENERGY↗

Form EIA-930 Data

Form EIA-930 data collection provides a centralized and comprehensive source for hourly operating data about the high-voltage bulk electric power grid in the Lower 48 states. We collect the data from the electricity balancing authorities (BAs) that operate the grid.

17 WIND ENERGY↗

Tuning Phase Lock Loop Controller of Grid Following Inverters by Reinforcement Learning to Support Networked Microgrid Operations

The dynamic operation of networked microgrids leads to varying topological configurations and generator commitments and dispatches. These variations correspond to systems with different electrical characteristics. The fixed control gains of high-speed power electronic devices may result in undesirable system performance when the electrical characteristics change significantly. As such, it is necessary to tune the control gains of power electronics devices to adapt to the changing system characteristics. This paper uses observer-based reinforcement learning to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing system strengths, that would be seen in networked microgrid operations. Simulation results using an operational electric distribution system, modeled as networked microgrids, are presented to demonstrate the need and effectiveness of the proposed adaptive controls.

networked microgrids, reinforcement learning, grid↗

Substation-Level Grid Topology Optimization Using Bus Splitting

Operations of substation circuit breakers are important for maintenance needs and topology reconfiguration in power systems. Bus splitting is one type of topology change where the two bus bars at a substation can become electrically disconnected under certain actions of circuit breakers. Because these events involve detailed substation modeling, they are typically not considered in routine power system operation and control. In this paper, an improved substation-level topology optimization framework is developed by expanding traditional line switching decisions by breaker-level bus splitting, which can further reduce grid congestion and generation costs. A tight McCormick relaxation is proposed to reformulate the bilinear terms in the resultant optimization problem to linear inequality constraints. Thus, a tractable mixed-integer linear program reformulation is attained that allows for efficient solutions in real-time operations. Numerical studies on the IEEE 14-bus and 118-bus systems demonstrate the computational performance and economic benefits of the proposed topology optimization approach.

bus split↗

VPP Participation Models: What is the Objective?

Virtual power plants (VPPs) can provide grid services by aggregating and controlling many distributed energy resources. However, their design, operation, level of participation, and outcomes depend on the regulatory and market environments they operate in, DER owner preferences, grid service value, and technical capabilities (e.g., communications, forecasting, controls, user interfaces). Although VPPs are inherently complex, they could enable high shares of behind-the-meter solar plus storage and reduce the cost of electrifying, e.g., personal vehicles and space heating.

demand response↗

Operation and Control of Soft Switching Solid State Transformer as a Virtual Synchronous Machine for Photovoltaic Application

Possibility for control and operation of a three-phase solid state soft switching transformer based as a virtual synchronous machine or synchronverter has been investigated in this paper. The soft switching solid state transformer is used as an interface between the ac grid and a photovoltaic power generation unit supported by a battery bank. The control architecture investigated in this paper is that of a synchronverter to achieve inertial support to the grid and local loads. The operation of the soft switching solid state transformer has also been investigated as a V S M during unbalanced/distorted grid voltage condition. Control objective to achieve oscillation free power transfer between the ports (photovoltaic, battery and grid) has been achieved. The presented architecture has been verified for several important case studies via numerical simulations based on MATLAB/Simulink domain.

grid current controller↗

Simulation of hydropower at subcontinental to global scales: a state-of-the-art review

Abstract Hydroelectric power is playing a new and often expanded role in the world’s major power grids, offering low carbon generating capacity in industrializing, dam-building economies while providing reserve and flexibility to co-manage fledgling wind and solar resources in high income countries. Driven by river flows, conventional hydropower is exposed to the vagaries of weather and climate, motivating drought and climate change hydropower impact studies at large spatial scales. Here we review methods of climate-driven hydropower simulation at large spatial scales, specifically multi-basin regions to global. We identify four types of approach based on complexity of tools and richness of data applied to the problem. Since the earliest attempts to model climate-driven hydropower at continental scale almost two decades ago, the field has transitioned from one of scientific curiosity to practical application, with studies increasingly motivated by the need to inform power grid expansion planning and operation. As the hydrological and water management models used in large-scale hydropower studies become more sophisticated, new opportunities will emerge to study the impacts of changing hydropower on power system reliability and performance at large power grid scale. To grasp these opportunities, the water resources community must continue to enhance data and models for representing river flows and anthropogenic water use and management at subcontinental to global scales.

13 HYDRO ENERGY↗

Threat Hunt Guide for BESS Environments

The rapid digitalization of the electric grid - driven by the integration of inverter-based resources (IBRs), battery energy storage systems (BESS), and advanced grid control platforms - has significantly enhanced grid efficiency, visibility, and flexibility. However, this evolution also introduces new cybersecurity risks, particularly through supply chain dependencies and operational blind spots at the grid edge. To address these challenges, Idaho National Laboratory (INL), through the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) Rapid Risk initiative, conducted a series of rapid risk assessment engagements with energy organizations across the United States. Drawing on lessons learned from these engagements, INL developed the following threat hunting guide for asset owners and operators (AOOs) to enhance their cybersecurity visibility within BESS and IBR systems. The guide demonstrates how to use passive network monitoring to baseline device behavior, detect adversarial activity, and investigate anomalies without disrupting operations. By implementing these practices, energy sector stakeholders can improve coordination between cybersecurity and operations teams and strengthen the resilience of distributed energy resources (DERs) within the modern power grid. Prior to implementing any network monitoring, packet capture, or threat hunting activity described in this guide, AOOs are strongly advised to review applicable governance frameworks, legal requirements, and organizational policies. This guide is intended for informational and educational purposes only. It does not replace compliance with any federal, state, or local cybersecurity mandates or industry standards. Implementation of described configurations, technologies, or analytic workflows is performed at the discretion and responsibility of the asset owner and operator.

25 - ENERGY STORAGE↗

Using Real-Time Electricity Prices to Leverage Electrical Energy Storage and Flexible Loads in a Smart Grid Environment Utilizing Machine Learning Techniques

With exposure to real-time market pricing structures, consumers would be incentivized to invest in electrical energy storage systems and smart predictive automation of their home energy systems. Smart home automation through optimizing HVAC (heating, ventilation, and air conditioning) temperature set points, along with distributed energy storage, could be utilized in the process of optimizing the operation of the electric grid. Using electricity prices as decision variables to leverage electrical energy storage and flexible loads can be a valuable tool to optimize the performance of the power grid and reduce electricity costs both on the supply and demand sides. Energy demand prediction is important for proper allocation and utilization of the available resources. Manipulating energy prices to leverage storage and flexible loads through these demand prediction models is a novel idea that needs to be studied. In this paper, different models for proactive prediction of the energy demand for an entire city using different machine learning techniques are presented and compared. The results of the machine learning techniques show that the proposed nonlinear autoregressive with exogenous inputs neural network model resulted in the most accurate predictions. These prediction models pave the way for the demand side to become an important asset for grid regulation by responding to variable price signals through battery energy storage and passive thermal energy storage using HVAC temperature set points.

25 ENERGY STORAGE↗