Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fueling stations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

ION Engineering Commercial Carbon Capture Design & Costing (C3DC) (Final Report)

ION Engineering LLC (ION) has coupled its proven, solvent-based CO 2 capture technology with an exceptionally qualified design and engineering team to complete a pre FEED for a 300-megawatt equivalent commercial-scale CO 2 capture plant for Gerald Gentleman Station’s (GGS) Generation Unit 2 (GGS2). The remarkable team was comprised of ION, Nebraska Public Power District (NPPD), Sargent & Lundy (S&L) with continued support from Koch Modular Process Systems (KMPS), and Siemens. The overall objective of the project was to provide the engineering design and cost estimate at an American Association of Cost Engineers (AACE) Class 3 estimate, resulting in accuracy ranges of -20 to +30% for the capital cost estimate. The project team was successful in completing this objective and was able to overcome the challenges that were presented during the process. A conservative interest rate of 7.0% with a financing term of 20 years was used based on interest rates utilized by S&L for this level of study. The resulting annualization factor is multiplied by the total EPC cost to calculate an annualized capital expenditure. It is estimated that the carbon capture facility treating a 300 MWe slipstream will capture 1.9 million tonnes per year of CO 2 at a capacity factor of 85%. The resulting cost of capture for the CO 2 island was determined to be $\$$36.55/tonne. Utilizing an interest rate of 4.5%, supported by historical rates for previous large capital projects in the power industry, reduces the cost of capture to $32.52/tonne. These cost of capture numbers continue to further ION’s case for commercial deployment of ION’s solvent technology.

20 FOSSIL-FUELED POWER PLANTS↗

Sub-Nanometer Nanoclusters of Copper Atop Single-Atom Copper Moieties toward Electrochemical CO 2 Hydrogenation to Methane

The electrochemical CO 2 reduction (eCO 2 R) offers a compelling route for converting CO 2 into value-added fuels and chemicals. Among CO 2 -derived products, methane (CH 4 ) occupies a distinct position, serving both as a key intermediate for emerging cascade electro-oxidation to oxygenates and as a strategically important extraterrestrial fuel that can be generated in situ from off-planet CO 2 resources. Although Cu-based catalysts capable of selectively producing CH 4 have been reported, they seldom sustain high selectivity at practically relevant current densities. Here, we created a single-step co-pyrolysis strategy toward generating and anchoring Cu sub-nanometer clusters (Cu SNC ) atop Cu-N x single-atom (SA) motifs embedded within N-doped carbon (NC), with controllable nanostructures through tuning of the synthesis parameters. Complementary spectroscopic analyses and density functional theory (DFT) calculations help reveal a structure−activity correlation that could guide the catalyst design. The Cu SNC @NC sample synthesized at 550 °C pyrolysis temperature (best described and modeled as Cu 3 -CuN 4 domains) represents the most effective combination of cluster size, metal-nitrogen coordination, and adsorption energetics needed to selectively promote CH 4 generation versus other eCO 2 R products. Incorporating pulsed electrolysis and hydrophobicity-modulated transport tuning at the triple-phase boundary (TPB) further enhanced CH 4 production achieving a partial CH 4 current density of ∼321 mA cm −2 , 53% Faradaic efficiency (FECH 4 ), and less than 4% combined FE for other eCO 2 R products, simplifying downstream CH 4 purification or upgrading. This work establishes generalizable principles for controlling Cu cluster atomicity and metal−nitrogen coordination, both of which are recognized determinants of CH 4 -efficient eCO 2 R.

CH4 production↗

Effect of pore fluid chemistry on the mechanical behavior of a divalent compacted bentonite, an experimental and constitutive study

Ongoing research in isolating high-level nuclear waste and spent fuel has highlighted compacted bentonite as a suitable material for engineered barrier systems in deep geological repositories due to its extraordinary swelling and retention properties. This research focuses on the chemo-mechanical behavior of compacted bentonite exposed to different pore fluids with different concentrations and loading conditions. The study involves swelling pressure and compressibility experiments along with mineralogy analysis employing X-ray diffraction (XRD) and Cation exchange. The tests were conducted on BCV (a Mg/Ca- bentonite) compacted at a dry density of 1.48 ± .02 Mg/m 3 . An advanced chemical-mechanical constitutive model for unsaturated highly expansive clays was adopted to simulate the material response and better understand its behavior. The model is able to account for the main phenomena at both macro and microstructural levels and the interactions between them. The model successfully replicated experimental observations. The XRD analyses support the macroscopic observation, indicating that salinity impacts crystalline swelling as demonstrated by the reduction of basal spacing from 19.27 Å to 15.68 Å when the osmotic suction increases from 0 MPa to 33 MPa. The results suggested that the osmotic pressure generated by the concentration in the pore fluids promotes a reduction in swelling pressures, swelling strains, and crystalline swelling of clay minerals. Also, it affects the pre-consolidation stress and the compressibility of the compacted samples. In conclusion, it was also observed that both solution type and solution concentration impact the clay swelling pressure.

Chemo-mechanical constitutive model↗

Geologic hydrogen: a review of resource potential, subsurface dynamics, exploration, production, transportation, and research opportunities

Hydrogen is a versatile resource with critical roles in decarbonization, industrial manufacturing, and energy integration. However, most hydrogen today is produced from fossil fuels, resulting in high emissions and energy consumption. Although low-carbon hydrogen production methods, such as steam methane reforming with carbon capture and renewable-powered electrolysis, are advancing, their high costs hinder large-scale deployment. Identifying alternative pathways for producing low-cost, low-emission hydrogen is therefore essential. Geologic hydrogen, referring to natural and stimulated hydrogen generated in the Earth's subsurface, has attracted growing attention as a potential source of sustainable, economically viable, and environmentally favorable hydrogen. This paper provides a comprehensive review of geologic hydrogen, covering its resource potential, origins, migration and trapping mechanisms, exploration techniques, production strategies, and pipeline transportation. It also identifies key knowledge gaps and proposes a roadmap for future research. The review indicates that geologic hydrogen has vast resource potential and can leverage existing subsurface technologies and geophysical exploration methods. However, major challenges persist, including uncertain hydrogen generation rates, limited understanding and control of serpentinization processes, costly transportation infrastructure, the lack of validated techno-economic analysis, and potential social and environmental issues. As the field is still in its early stages, progress will require interdisciplinary collaboration spanning geoscience, engineering, economics, environmental science, and policy and regulation.

42 ENGINEERING↗

Filer City Biomass Carbon Removal and Storage (BiCRS) Net-Negative Study

NorthStar Clean Energy Company (NorthStar) conducted the Filer City Biomass Carbon Removal and Storage (BiCRS) Net-Negative Study to develop a conceptual design and cost estimate for retrofitting the TES Filer City Station with post-combustion carbon capture technology in Mainstee Michigan. The Filer City BiCRS Net-Negative Study allowed NorthStar and team to confirm the commercial feasibility of a post-combustion carbon capture system applied to biomass-fired boilers. At the time of the study, there were no operating facilities in the world with carbon capture applied to flue gas from woody biomass as proposed for Filer City. Due to the solvent-agnostic nature of B&W’s SolveBright™ technology, the team determined that multiple amines, both traditional and proprietary, would be capable of 95% CO 2 capture efficiency with the steam available from Filer City’s existing boilers after modifications to burn 100% biomass. Based on the cost estimates produced, NorthStar can now confirm the Filer City BiCRS Project is economically viable with a combination of tax credits available from the Inflation Reduction Act of 2022 and high-quality Carbon Dioxide Removal Credits sold on the Voluntary Carbon Market. The Filer City BiCRS project is uniquely positioned to become one of the first projects to capture and sequester large volumes of CO 2 from a biogenic source, removing existing CO 2 from the atmosphere. The unlimited version of the Filer City Biomass Carbon Removal and Storage (BiCRS) Net-Negative Study Final Technical Report is attached.

01 COAL, LIGNITE, AND PEAT↗

Speciation mapping of the oxidation layer on aged uranium dioxide using scanning transmission x-ray spectromicroscopy

In this study, UO 2 was aged in humid air and prepared as a thin section using a focused ion beam (FIB) instrument. The specimen was measured using synchrotron radiation spectromicroscopy techniques at the Beamline 11.0.2 STXM end station of the Advanced Light Source (ALS). Non-negative matrix factorization (NMF) methods were used to identify and map three component x-ray absorption near-edge structure (XANES) spectra in the oxygen K-edge data, revealing a surface layer of U 4 O 9 with a thickness of 206 ± 21 nm, and the bulk of the sample remaining as UO 2 . Uranium N 4,5 -edge XANES spectromicroscopy supports these results. The diffusion-controlled parabolic rate constant for UO 2 oxidation to U 4 O 9 was calculated from the observed layer thickness and compared to literature values. Complementary transmission electron microscopy (TEM) was used to image the sample and identify the phases present in various regions, confirming the STXM results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Autonomous Aerial Power Plant Inspection in GPS-denied Environments

Inspection of coal-fired power plants is frequently dangerous, includes difficult places to reach, and can turn expensive due to the downtimes and cost of inspection crew. Robotic systems have shown capabilities to address some of these issues, but most of the current robotic inspection technology in power plants is designed for specific components. Conversely, recent advances in machine vision have empowered aerial platforms for long-range, remotely-controlled, GPS-based inspections of industrial plants. This capability has led to wide spread utilization of aerial robots (commonly termed Drones, UVS or UAS) platforms for inspection in less challenging environments where both collision avoidance, and GPS reception are not significant issues. The challenge in adapting airborne technology for power plant inspection lies in internal structures and the complex network of piping, and distribution systems, which impose significant risks for collision and can hinder the reception and transmission of GPS signals. The current state of the art in aerial inspection technology within the energy sector is controlled via radio control, and utilizes GPS-based navigation, for inspection of large-scale plants such as offshore platforms and wind turbine parks. Nevertheless, close-range and autonomous inspection in the GPS-denied environments of power plants has not yet been achieved, as it requires precise guidance and navigation with real-time situational awareness and obstacle avoidance capabilities. This endeavor introduced the use of rotary wing flying robots, due to their station keeping and vertical take-off capabilities for power plant components inspection. To enable close quarter inspection two methods were used. One method uses the 3D CAD (Three-dimensional Computer-Aided Design) model of the asset to inspect to generate the UAV’s inspection path. To acquire, analyze and process the 3D model, first, the STL file is produced to obtain surface points and vectors normal to the surface. Later, by introducing other variables such as wall offset and a controlled trajectory between each outline and each subsequent layer, the flight path is generated. The proposed framework will generate a path that will pass as close as desired from the surface and navigate in intricate environments. A second method, use advanced manufacturing techniques such as CNC (Computer Numerical Control) and additive manufacturing. Once the inspection flight path is obtained, vision-based navigation systems are employed to have the UAV autonomously tracking the provided trajectory. Finally, Artificial Intelligence-enabled developments are in charge of detecting cracks and corrosion in structural components of power plants. The proposed methods are validated in simulations, laboratory and industrial setups, where it is shown that the developed systems acting together enable close-quarter autonomous aerial inspection and mapping in power plant assets. The system can be further improved by adding more sensors to navigate in different GPS-denied environments, with non-homogeneous lighting conditions, dust and in general situations where vision-based systems may fail.

01 COAL, LIGNITE, AND PEAT↗

Atikokan Digital Twin: Machine learning in a biomass energy system

The Atikokan Generating Station, operated by Ontario Power Generation, has a 200 MW, biomass-fired tower boiler that operates on a dispatch schedule with a five-minute cycle. The boiler is generally operated in the range of 40–100 MW using two of five burner levels. In order to optimize boiler performance, we propose the implementation of a unique digital twin. Our digital twin abstraction couples Bayesian inference from science-based models and from observations (machine learning) with decision theory to predict operating-variable set points that optimize the physical asset (the boiler) in the presence of uncertainty (artificial intelligence). We focus this paper on the continuous Bayesian machine learning part of the Atikokan Digital Twin; we discuss decision theory in a companion paper. We identify and learn about 12 operational, model, and measured-output parameters and their uncertainties from high-fidelity, science-based simulations of the Atikokan boiler and from the observed measurements at the power plant. Since the goal of the Atikokan Digital Twin is to implement it online in real time, we require fast function evaluations for the quantities of interest extracted from the simulations in the Bayesian analysis. We use Gaussian process regression/interpolation to create accurate, robust surrogate models. We define the Bayesian priors and likelihood function and solve for the posterior distributions of the 12 parameters. Here we then propagate these distributions (i.e., parameters with uncertainty) into the predicted distributions of 790 quantities of interest to learn about the relative importance of various sources of error including experimental, model, and operating-parameter errors.

09 BIOMASS FUELS↗

Efficient screening of rare large pit anomalies on polished surfaces using a minimalist sampling scheme

Lawrence Livermore National Laboratory (LLNL) has made significant strides in generating clean energy through its inertial confinement fusion (ICF) experiments. These experiments rely on high-density carbon (HDC) coated shells to encapsulate the fusion fuel. The success of these experiments is heavily dependent on the surface quality of these shells, as even minor imperfections, such as deep pits, can negatively impact fusion yield. Ensuring the required smoothness involves an extensive surface-finishing process that spans approximately 20 stages, making it both time-intensive and resource-demanding. A critical challenge in this process is the need for high-resolution scans to detect rare deep pits, which can be costly and impractical if performed on every shell. This highlights the necessity of developing more efficient scanning methods to optimize time and cost without compromising accuracy. To address these challenges, we introduce a novel approach that employs the multivariate Dvoretzky–Kiefer–Wolfowitz (DKW) inequality to provide a probabilistic upper bound on the error in estimating pit distribution characteristics via a Kernel Density Estimator (KDE). This error bound enables efficient and reliable estimation of pit distribution characteristics at a specified statistical confidence level using a minimal number of surface scans. The integrated DKW-KDE approach was validated through surface-finishing experiments across two batches of HDC-coated shells, demonstrating consistent and robust performance across multiple stages of the surface-finishing experiments. The validation studies suggest that the integrated DKW-KDE approach achieves comparable accuracy in estimating the risk of deleterious large pits with six scans, thus conserving time and resources. Further evaluations show that performance remains consistent across batches and over multiple polishing stages. In conclusion, based on these findings, one can leverage the minimal-scan insights to strategically improve the bottleneck inspection process, thus enhancing the productivity and quality of shell polishing and similar challenging manufacturing processes.

Inertial confinement fusion↗

CO 2 to Bioplastics: Beneficial Re-use of Carbon Emissions from Coal-fired Power Plants using Microalgae

This project sought to address the technical and economic barriers to carbon dioxide (CO 2 ) capture and utilization using microalgae. Specifically, a dual photobioreactor (PBR)/open raceway pond (ORP) cultivation system was evaluated with respect to capital and operational costs, productivity, and culture health, and compared to an ORP-only cultivation system. In the dual (or “hybrid”) system, a cyclic flow PBR was used to provide inoculum for two open raceway ponds after each harvest, with the hypothesis that this PBR + pond system should result in improved performance compared to traditional raceway ponds. Two other raceway ponds were operated conventionally as a control, the experiments being performed at Duke Energy’s East Bend Station in northern KY using coal-derived flue gas as the CO 2 source. Although algae productivity achieved was mediocre due to the fact that the experiments had to be performed late in the growing season when climatic conditions were not optimal for high growth, the hybrid cultivation system showed a higher level of algae productivity (statistically significant) compared to the traditional ponds. In order to realize the maximum value of the algal biomass produced, fractionation of the biomass was examined. Bioplastic compounding and material characterization was subsequently performed using three feed stocks: whole biomass, lipid-extracted biomass and the proteinaceous residue from full fractionation. In general, the whole and lipid-extracted biomass gave similar results in terms of the properties of the resulting bioplastics, while the proteinaceous residue showed promise for the production of a polybutylene adipate terephthalate (PBAT) blend. Finally, sustainability assessment of a putative biorefinery system was conducted, including techno-economic and life cycle impact assessment. Nine different production scenarios were considered, comprising combinations of the three different biomass growth architectures (ORP, PBR and dual PBR-ORP systems) coupled with three different algae biomass processing pathways (drying only, lipid extraction and fractionation). Results show that the minimum selling price of the bioplastic feed stock (BPFS) is within the realm of economic competition with prices as low as $970 USD tonne -1 . Additionally, life cycle impact assessment results indicate drastic improvements in performance of the produced BPFS, with reductions in greenhouse gas emissions ranging between 67 and 116% compared to a petroleum based plastic feedstock.

01 COAL, LIGNITE, AND PEAT↗

Wastewater Recycling Using a Hygroscopic Cooling System

This project by the Energy & Environmental Research Center (EERC), Baltimore Aircoil Company (BAC), and Great River Energy (GRE) evaluated the concept of recycling wastewater at a coal-fired power plant using a hygroscopic cooling system, which is an evaporative cooling technology analogous to conventional cooling towers, except that sparingly soluble dissolved solids are precipitated and removed as waste solids instead of purging them with a liquid blowdown stream. This technology can maximize the use of plant makeup water by obtaining useful evaporative cooling from wastewater while minimizing the volume of wastes needing disposal. Experimental activities were conducted in two phases, a laboratory-based evaluation of the properties of wastewater from the host site, GRE’s Coal Creek Station near Underwood, North Dakota, and a field test of a small pilot hygroscopic cooling system at the host site power plant. Findings from the laboratory study informed the design of the pilot system and the system’s field test performance served as the basis for a techno-economic analysis (TEA) of the hygroscopic recycling concept. At the preferred operating conditions identified during the TEA, the wet-bulb approach temperature of the tower was 7.3°C (13°F) and the volume of blowdown produced by the plant was reduced to 5.4% of its incoming volume. Waste solids produced during field testing were classified as nonhazardous waste based on the measured hazardous element content and evaluation of their leaching potential. However, to qualify as a solid for landfill disposal i.e., as determined by the U.S. Environmental Protection Agency’s paint filter test, it appears that a dewatering step beyond hydrocyclone separation is needed. The baseline levelized cost of wastewater disposal (LCWD) for hygroscopic wastewater recycling was estimated to be $\$ $3.69–$\$ $3.72 per m3 of plant blowdown. Capital cost was estimated to contribute over 54% to the LCWD, and parameters that impact capital cost such as the heat exchange coil material of construction and the tower’s wet-bulb approach temperature were identified as having the greatest impact on overall LCWD. A LCWD estimate prepared for the same application but using thermomechanical brine evaporation was almost 40% higher than that calculated for hygroscopic cooling, despite recovering distilled-quality water for reuse, while the LCWD for disposal-only, deep well injection was estimated to be 30% lower compared to hygroscopic wastewater recycling.

01 COAL, LIGNITE, AND PEAT↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO 2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-Fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO 2 ) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO 2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Application of a Heat Integrated Post-combustion CO 2 Capture System with Hitachi Advanced Solvent into Existing Coal-Fired Power Plant (Final Technical Report)

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0007395. In accordance with the Project Management Plan (PMP), Revision F dated 5/10/2019, and Statement of Project Objectives (SOPO) within, the University of Kentucky (UK) Center for Applied Energy Research (CAER) (Recipient) has successfully demonstrated a unique, versatile CO 2 capture system (CCS) using a heat integrated process combined with two-stage stripping for process intensification, heat recovery and demineralized (DM) water generation. This project involved the design, fabrication, installation, testing of and data analysis from the UK CAER 0.7 MWe small pilot scale CO2 capture process installed at Kentucky Utilities (KU) E.W. Brown Generating Station in Harrodsburg, KY. During each of the four project Budget Periods (BPs), UK CAER met all project deliverables, all project milestones, with National Energy Technology Laboratory (NETL) approved adjustments made to the campaign long-term hours during BP4. The CCS was constructed in modular skids. Two solvent campaigns were initially conducted; the first with a 30 wt% monoethanolamine (MEA) as a baseline, and the second with the Hitachi H3-1 advanced solvent. Additional tests were performed with two advanced solvents including CAER and Proprietary Solvent C. Short-period testing with a higher concentration of 40 wt% MEA was conducted to evaluate the potential saving with high alkalinity. From the various solvent campaigns, unique aspects of the UK CAER CCS technology, as well as its flexibility and versatility were experimentally validated and demonstrated. With respect to solvent evaluation efforts in identifying candidates with significant operational and capital cost savings potential, performance of solvents were evaluated to determine the energy requirements for regeneration; environmental impacts from secondary emissions and degradation products; degradation rates, solvent make-up rates and stability. The assessments were done from parametric tests that determined optimum operating conditions for the individual solvents to maximize process efficiency and minimize the parasitic load of the power plant, and from long term campaigns (1000 hours for 30 wt% MEA and 1000 hours for H3-1) which collectively informed the techno-economic analyses (TEA) of the process. The long term campaigns included corrosion studies which used three types of metal coupons in different sections of the process: (absorber, primary stripper, lean carbon-loaded and rich carbon loaded flow streams in process) to mimic heat and flow dynamics process equipment were exposed to. The estimated corrosion rates were used to elucidate corrosion mechanisms and to further guide process material selection for potential capital cost savings.

gas separation↗

Hydrodynamics of Two-Phase Flows through Porous Media in Microgravity: Packed Bed Reactor Experiment onboard of the International Space Station

The objective of the Packed Bed Reactor Experiment was to develop a fundamental understanding of the hydrodynamics of two-phase flow with no phase transition through porous media in microgravity. This work describes two experimental campaigns flown on the International Space Station (ISS) that were designed to achieve the objective. This work presents the results on flow patterns observed, two-phase flow pressure drop in porous media, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work is the first to present predictive correlations of the two-phase friction factor for the different regimes identified based on the superficial liquid and gas velocity in microgravity, the first to hypothesize the different regimes based on the change in slope of the pressure gradient versus flow rate plots, the first to address the effects of the capillarity on the pressure gradient and the first to measure column holdup and assess the effective porosity based on the packing and the trapped gas bubbles. Experimental data on pressure drop in gas (N2) – liquid (water) flow show the presence of four different flow regimes in microgravity. Dispersed bubble flow (DB) and pulse (P) flow regimes are detected at high liquid flow rates, whereas at low liquid flow rates “large bubble” or elongated bubble (LB) and “gas channeling” (GC) regimes are observed. For these different flow regimes, different two-phase flow friction factor and pressure gradient correlations are presented for the first time as a function of the gas and liquid modified Reynolds numbers and Suratman number. Within the viscous-capillary (V-C) regime, it is found that the capillary contribution is the dominant force that contributes to the pressure drop for the wetting case (glass). However, for the non-wetting packing (Teflon), the viscous contribution dominates. It was found that the gas hold-up and pressure drop are functions of bed history at low liquid and gas flow rates with the magnitude of the hysteresis decreasing with increasing flow rates. PBRE-2 results show that the capillary force is a strong function of the superficial liquid velocity but is a much weaker function of the superficial gas velocity and varies inversely with the particle diameter. Within the Viscous-Capillary (V-C) regime, over 90% of the pressure gradient is attributed to the capillary contribution in the gas continuous regime. However, in the large bubble regime, the viscous and capillary contributions were comparable. After the completion of PBRE-2 with glass spherical beads, another bed packed with alumina was installed. Pressure gradient data for the alumina packed bed (PBRE-Water Recovery) were transferred to the PI and were not analyzed by the authors of this work. The Packed Bed Reactor Experiment concluded its on-orbit operation after two successful campaigns of testing in 2017 and in 2021. The flight hardware was brought back from orbit and is being reconditioned for a series of future experiments referred to as PBRE-WRS in support of water recovery (WRS). The WRS series consists of testing different two-phase fluid system components and packed beds to assess their pressure gradient characteristics, which will be used for designing packed bed reactors for various applications relevant to life support. Although there is so much relevance of the experimental results obtained from the two PBRE campaign in microgravity to life support, these findings also apply to other applications that involve two phase flow in porous medium such as fuel cells, transport of nutrient to plants in space and other chemical and materials processing that involve two phase flows. These systems operate differently in microgravity because, due to the lack of buoyancy, the density difference between the phases becomes irrelevant and no longer leads to phase separation.

Packed Bed↗

Revolutionizing Energy Storage: AI, Automation, and Advanced Modeling as Catalysts for Next-Generation Breakthroughs

The Presidential Symposium (PRES) at the 2025 Fall Meeting, hosted by the President’s Office and Energy and Fuels Division, American Chemical Society (ACS) in Washington, DC, brought together a diverse group of chemists, engineers, and materials scientists working in battery materials & systems, automation and artificial intelligence from academia, industry, and national laboratories. The accelerating demand for high-performance, scalable, and sustainable energy storage has catalyzed a paradigm shift in how materials are dis-covered, devices are engineered, and systems are optimized. This Presidential Symposium, entitled “Revolutionizing Energy Storage: AI, Automation, and Advanced Modeling Driving Next-Gen Breakthroughs”, brings together global leaders to unveil transformative strategies anchored in the AAA framework: Artificial Intelligence, Automation, and Advanced Modeling. Artificial Intelligence is redefining the frontiers of energy storage by enabling predictive design, real-time optimization, and intelligent control across diverse chemistries and architectures. Automation is streamlining the synthesis, characterization, and testing of battery materials, dramatically accelerating innovation cycles and unlocking scalable solutions for grid and mobility applications. Advanced Modeling, spanning atomic to system-level scales, provides unprecedented insight into electrochemical dynamics, degradation pathways, and thermal behavior, particularly when coupled with physics-informed machine learning and digital twin technologies. Digital twins, in turn, leverage the AAA framework by integrating real-time data, physics-based models, and AI predictions into dynamic virtual replicas, enabling proactive diagnostics, optimization, and system resilience. Together, these synergistic pillars are not only re-shaping the scientific landscape but also forging a new era of reproducible, data-driven, and resilient energy storage innovation. In conclusion, this symposium marks a pivotal moment in the convergence of computational intelligence and experimental rigor, charting the course for next-generation breakthroughs in lithium-ion, solid-state, and flow battery technologies.

Artificial Intelligence (AI)↗

Chromium Tolerant, Highly Active and Stable Electrocatalytic Internal Surface Coating for Cathode of Commercial SOFCs (Final Report)

This project is aimed to develop a chromium (Cr) tolerant, highly active, and stable coating layer on the internal surfaces of the porous composite cathode from commercially available SOFCs. Such coating layer was developed using the additive manufacturing process of Atomic Layer Deposition (ALD) and has been applied on the cathode consisting of either an electronic conductor of LaxSr 1-x MnyO 3-δ (LSM) or mixed ionic and electronic conducting La x Sr 1-x Co y Fe 1-y O 3-δ (LSCF). PI's work has demonstrated that the internal surface of cathode from the commercial cells, can be further tailored using ALD coating to dramatically enhance the cell performance. For instance, ALD layer consisting heterostructured nano composite of nano-Pt and nano-(Mn 0.8 Co 0.2 ) 3 O 4 oxide on the internal surface of porous LSM/YSZ cathode from SOFCs, has resulted in the large reduction of the cell polarizations resistance by up to 53%, and enormous increase of power density over 370%. For the cells with LSCF/Sm 2 O 3 doped CeO 2 (SDC) cathode, the conformal layer of nano-composite consisting of superjacent CoOx and subjacent minimum amount of Pt nano-grains has resulted in the power density enhancement by 126% for the large scale industry tubular cells at 750°C, and both the performance enhancement and nanostructure of the ALD layer are stable over ~ 2000 h continuous operation performed at industry test station. In the meanwhile, those ALD coating layer developed by PI's work is also inherently Cr-tolerant, and could act as physical barrier for preventing Cr diffusion into the cathode backbone, so as to mitigate the Cr poisoning effect on the cathode. In this project, the impact of Cr on the performance of those ALD coated commercial cells has been evaluated. Based on evolution of the cell performance, the ALD coating layer chemistry and ALD coating layer thickness has been optimized to maximize the overall Cr tolerance, cell power density and cell longevity. Different ALD coating has been applied onto the internal surface of LSM/YSZ and LSCF/SDC backbone respectively. The architecture/scaffold structures on the internal surface of different cathode, designed by this project, was catalogued and analyzed using High Resolution Transmission Electron Microscopy (HRTEM), and cell power/durability performance are assured via comprehensive electrochemical performance testing in the industry operation relevant conditions. The impact of the electrochemical operation current density, the water humidity, the cell operation temperature, and cell operation duration on the Cr tolerance of ALD coated cells has been systematically investigated. There is completely different nanostructure degradation mechanisms between LSM and LSCF cells induced by Cr contamination. For the LSCF/SDC baseline cell, With the Cr source, there is no apparent Sr surface segregation phase even for the baseline cell operated for 3000 h at 750 °C. With the Cr source, there is significant amorphous (SrCr)Ox phase accumulated in the original pore region. For the commercial baseline cells, Cr contaminants on the LSM electrode severely impacted the entire cell's electrochemical performance and nanostructure degradation. Those degradations include (1). Peak power density loss of 64 % after 109 h of operation. The dramatic increase in Rp (2). They are cracking at LSM/SSZ interface, LSM grains. SSZ remains intact but with (CrMn)Ox. By contrast, ALD coating (MnCo)Ox/Pt dramatically improves the Cr resistance, as follows (1). ALD-coated cell with a power density is 280-380 % of the baseline cell, depending on the ALD layer thickness. (2). For a cell with a 20 nm thick ALD layer, there is a large performance enhancement (> 200 % power density) induced by ALD coating of Cr-tolerant Mn 0.8 Co 0.2 Ox. (3). For a cell with a 20 nm thick ALD layer, after 168 h at 750 °C power density of the ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination for 109 h. The ALD coating on the internal surface of cathode developed by this project integrated multi-functions. Those multi-functions include (1). Dramatically improving the cell power density for the commercial cells; (2). Dramatically improving contamination resistance of the cathode, for being an excellent protection coating layer sealing off Cr contamination. (3). Dramatically increasing the cell longevity by potentially preventing the microstructure evolution and grain coarsening of the cathode. Overall, this project will provide a simple solution to simultaneously enhance power density and increase the reliability, robustness, and endurance of commercial SOFCs, over the entire operating temperature range of 650-800 °C. For the inherently functional SOFC, the ALD coating of LSM based cathode mitigate the Cr-contamination. Power density of ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination. In addition to SOFCs, the novel on-demand design approach and creation of multifunctional heterogeneous architecture on the electrode surface presented in this work opens further research for their application in other types of fuel cells, batteries, and sensors for which electrochemical reactions on the surface are similarly critical.

36 MATERIALS SCIENCE↗