Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frost”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

New search for mirror neutron regeneration

The possibility of relatively fast neutron oscillations into a mirror neutron state is not excluded experimentally when a mirror magnetic field is considered. Direct searches for the disappearance of neutrons into mirror neutrons in a controlled magnetic field have previously been performed using ultracold neutrons, with some anomalous results reported. We describe a technique using cold neutrons to perform a disappearance and regeneration search, which would allow us to unambiguously identify a possible oscillation signal. An experiment using the existing General Purpose-Small Angle Neutron Scattering instrument at the High Flux Isotope Reactor at Oak Ridge National Laboratory will have the sensitivity to fully explore the parameter space of prior ultracold neutron searches and confirm or refute previous claims of observation. This instrument can also conclusively test the validity of recently suggested oscillation-based explanations for the neutron lifetime anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental studies of low density and temperature ion and electron sheaths

Full characterization of nighttime ionospheric plasma requires access to both the ion and electron thermal core populations. Efforts to measure particle distributions with rocket and satellite detectors designed to study low energy particles are hindered because the magnitude of spacecraft charging is on the order of or greater than the energy of the bulk of ionospheric particles. This paper presents initial laboratory investigations exploring the formation of plasma sheaths with ionospheric electron energies, densities, and Debye lengths. The goal is to identify the difficulties and solutions to obtaining both thermal electron and ion velocity distributions on one payload. Sheaths around a long cylinder biased with respect to the vacuum vessel wall are studied to verify measurement procedures. An experimental setup in which two conducting spheres, with area ratios in excess of 100, are biased with respect to one another and not referenced to the wall simulates a payload-detector system. Data are compared with simple planar, cylindrical, and spherical sheath models. Ion-rich sheaths conformed with expectations. The criterion for the formation of electron-rich sheaths was found not only to depend on the ratio of ion collector area to electron collector area but also the ratio of the collector area to sheath area. Nonmonotonic electron sheaths obtained by embedding a positively biased electrode within the sheath of a more negative conductor are also explored. It was found that the superposition of two different potential geometries led to the formation of the nonmonotonic potential structures. These initial plasma ion and electron sheath investigations both clarify the behavior of a thermal electron detector previously flown in the ionosphere and explore a low energy parameter regime that is understudied in the laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ripple rotation, pattern transitions, and long range ordered dots on silicon by ion beam erosion

The importance of the ion incidence angle in self-organized pattern formation during low energy Xe{sup +} ion beam erosion of silicon is elaborated. By a small step variation of the ion incidence angle, a variety of nanostructured patterns can develop. In this context, the angular distribution of ions within the ion beam is explored as an additional parameter controlling the evolution of the surface topography. Due to a controlled variation of these two parameters, hitherto unknown phenomena are found: (i) formation of rotated ripples, (ii) continuous transitions between patterns, and (iii) long range square ordered dot patter000.

36 MATERIALS SCIENCE↗

Facility for fast neutron irradiation tests of electronics at the ISIS spallation neutron source

The VESUVIO beam line at the ISIS spallation neutron source was set up for neutron irradiation tests in the neutron energy range above 10 MeV. The neutron flux and energy spectrum were shown, in benchmark activation measurements, to provide a neutron spectrum similar to the ambient one at sea level, but with an enhancement in intensity of a factor of 10{sup 7}. Such conditions are suitable for accelerated testing of electronic components, as was demonstrated here by measurements of soft error rates in recent technology field programable gate arrays.

43 PARTICLE ACCELERATORS↗

Searching for Black Holes with the ATLAS Detector

Models with extra spacial dimensions offer a new way to address problems in the Standard Model. The most spectacular manifestation of these would be the production and decay of microscopic black holes. The outlook and potential of the ATLAS detector at the LHC to discover and measure black holes in models with large extra dimensions is presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Phenomenology of Rotating Extra-Dimensional Black Holes at Hadron Colliders

Results are presented from CHARYBDIS2, a new Monte Carlo simulation of black hole production and decay at hadron colliders. The main new features of CHARYBDIS2 are a full treatment of the spin-down phase of the decay process using the angular and energy distributions of the associated Hawking radiation, improved modelling of the loss of angular momentum and energy in the production process as well as a wider range of options for the Planck-scale termination of the decay. The new features allow the study of the effects of black hole rotation and the feasibility of its observation. We present results, with emphasis on the consequences and experimental signatures of black hole rotation at the LHC. The effects of rotation are found to be large, with substantial changes to particle energies and distributions. Rotation persists throughout evaporation, invalidating the approximation of a rapid spin-down followed by isotropic emission in a non-rotating Schwarzschild phase. A selection of results are presented from the original article, arXiv:0904:0979.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diamond detector for high rate monitors of fast neutrons beams

A fast neutron detection system suitable for high rate measurements is presented. The detector is based on a commercial high purity single crystal diamond (SDD) coupled to a fast digital data acquisition system. The detector was tested at the ISIS pulsed spallation neutron source. The SDD event signal was digitized at 1 GHz to reconstruct the deposited energy (pulse amplitude) and neutron arrival time; the event time of flight (ToF) was obtained relative to the recorded proton beam signal t{sub 0}. Fast acquisition is needed since the peak count rate is very high ({approx}800 kHz) due to the pulsed structure of the neutron beam. Measurements at ISIS indicate that three characteristics regions exist in the biparametric spectrum: i) background gamma events of low pulse amplitudes; ii) low pulse amplitude neutron events in the energy range E{sub dep}= 1.5-7 MeV ascribed to neutron elastic scattering on {sup 12}C; iii) large pulse amplitude neutron events with E{sub n} < 7 MeV ascribed to {sup 12}C(n,{alpha}){sup 9}Be and 12C(n,n')3{alpha}.

43 PARTICLE ACCELERATORS↗

Small-signal modulation and differential gain of red-emitting (λ = 630 nm) InGaN/GaN quantum dot lasers

We report small-signal modulation bandwidth and differential gain measurements of a ridge waveguide In{sub 0.4}Ga{sub 0.6}N/GaN quantum dot laser grown by molecular beam epitaxy. The laser peak emission is at λ = 630 nm. The −3 dB bandwidth of an 800 μm long device was measured to be 2.4 GHz at 250 mA under pulsed biasing, demonstrating the possibility of high-speed operation of these devices. The differential gain was measured to be 5.3 × 10{sup −17} cm{sup 2}, and a gain compression factor of 2.87 × 10{sup −17} cm{sup 3} is also derived from the small-signal modulation response.

36 MATERIALS SCIENCE↗

Temperature-dependent measurement of Auger recombination in In{sub 0.40}Ga{sub 0.60}N/GaN red-emitting (λ = 630 nm) quantum dots

We have derived the Auger recombination coefficients, as a function of temperature, for In{sub 0.4}Ga{sub 0.6}N/GaN self-organized quantum dots from large-signal modulation measurements made on lasers in which the quantum dots form the gain media. The value of C{sub a} = 1.3 ±0.2 × 10{sup −31} cm{sup 6} s{sup −1} at room temperature and the coefficient decreases with increase of temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GaAs-based high temperature electrically pumped polariton laser

Strong coupling effects and polariton lasing are observed at 155 K with an edge-emitting GaAs-based microcavity diode with a single Al{sub 0.31}Ga{sub 0.69}As/Al{sub 0.41}Ga{sub 0.59}As quantum well as the emitter. The threshold for polariton lasing is observed at 90 A/cm{sup 2}, accompanied by a reduction of the emission linewidth to 0.85 meV and a blueshift of the emission wavelength by 0.89 meV. Polariton lasing is confirmed by the observation of a polariton population redistribution in momentum space and spatial coherence. Conventional photon lasing is recorded in the same device at higher pump powers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molecular ferroelectric contributions to anomalous hysteresis in hybrid perovskite solar cells

We report a model describing the molecular orientation disorder in CH{sub 3}NH{sub 3}PbI{sub 3}, solving a classical Hamiltonian parametrised with electronic structure calculations, with the nature of the motions informed by ab initio molecular dynamics. We investigate the temperature and static electric field dependence of the equilibrium ferroelectric (molecular) domain structure and resulting polarisability. A rich domain structure of twinned molecular dipoles is observed, strongly varying as a function of temperature and applied electric field. We propose that the internal electrical fields associated with microscopic polarisation domains contribute to hysteretic anomalies in the current-voltage response of hybrid organic-inorganic perovskite solar cells due to variations in electron-hole recombination in the bulk.

36 MATERIALS SCIENCE↗

Electrically pumped single-photon emission at room temperature from a single InGaN/GaN quantum dot

We demonstrate a semiconductor quantum dot based electrically pumped single-photon source operating at room temperature. Single photons emitted in the red spectral range from single In{sub 0.4}Ga{sub 0.6}N/GaN quantum dots exhibit a second-order correlation value g{sup (2)}(0) of 0.29, and fast recombination lifetime ∼1.3 ±0.3 ns at room temperature. The single-photon source can be driven at an excitation repetition rate of 200 MHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PIND: High spatial resolution by pinhole neutron diffraction

Here, a pinhole neutron diffraction (PIND) technique was developed to enable improving the spatial resolution down to 250 μm. Instead of the conventional engineering diffraction method which integrates all the diffraction signals on the detector plane, the PIND setup utilizes the diffraction pattern of each pixel on 2D detectors. The proposed PIND arrangement enables improving the spatial resolution of time-of-flight instruments and allows solving problems involving steep gradients of strain or texture. The phase content and preferential orientation of grains inside samples can be spatially resolved in 2D/3D. Further, PIND retains the capability of in-situ non-destructive neutron diffraction mapping of lattice strain and grain orientation under external stimuli such as temperature and force.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simultaneous 8.2 keV phase-contrast imaging and 24.6 keV X-ray diffraction from shock-compressed matter at the LCLS

In this paper, we demonstrate simultaneous phase-contrast imaging (PCI) and X-ray diffraction from shock compressed matter at the Matter in Extreme Conditions endstation, at the Linac Coherent Light Source (LCLS). We utilize the chromaticity from compound refractive X-ray lenses to focus the 24.6 keV 3rd order undulator harmonic of the LCLS to a spot size of 5 μm on target to perform X-ray diffraction. Simultaneous PCI from the 8.2 keV fundamental X-ray beam is used to visualize and measure the transient properties of the shock wave over a 500 μm field of view. Furthermore, we demonstrate the ability to extend the reciprocal space measurements by 5 Å –1 , relative to the fundamental X-ray energy, by utilizing X-ray diffraction from the 3rd harmonic of the LCLS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Isotope effects on the high pressure viscosity of liquid water measured by differential dynamic microscopy

In this paper, differential dynamic microscopy is performed in diamond anvil cells to measure the viscosity of water along the 24 °C isotherm to high-pressure by determination of the tracer diffusion coefficient of monodisperse silica spheres of known diameter and application of the Stokes-Einstein-Sutherland equation. This technique allows liquid samples to be compressed to greater pressure prior to freezing than with other viscometry methods. The highest-pressure measurement was made at 1.67 GPa, considerably deeper into the supercompressed regime than previously reported. The effect of isotopic composition is investigated with samples of normal water, heavy water, and partially deuterated water. When data below 0.25 GPa are excluded a free volume model fits the observed viscosities well yielding a theoretical glass transition density close to that observed in very-high-density amorphous ice. The improved fit above 0.25 GPa coincides with the loss of other anomalous behaviors in liquid water caused by hydrogen bonding and represents a transition to properties closer to those of a simple liquid.

74 ATOMIC AND MOLECULAR PHYSICS↗

A high-pressure flow through test vessel for neutron imaging and neutron diffraction-based strain measurement of geological materials

Neutron scattering and neutron imaging have emerged as powerful methods for experimentally investigating material deformation and fluid flow in the interior of otherwise inaccessible or opaque structures. This paper describes the design and provides example uses of a pressure cell developed for investigating such behaviors within geological materials. The cell can accommodate cylindrical samples with diameters up to 38.1 mm and lengths up to 154 mm. Additionally, ports in the cell and a pressure isolating sleeve around the sample allow the independent application of confining pressure up to 69 MPa and axial pressure up to 34.5 MPa. Furthermore, two material versions of the cell have been manufactured and used to date. An aluminum version is typically used for temperatures below 40 °C, because of its relative transparency to neutrons, while a titanium version, which is comparatively more neutron attenuating, is used for experiments requiring triaxial pressurization under conditions up to 350 °C. The pressure cells were commissioned at the VULCAN engineering diffractometer at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source, and have since been used at the ORNL high flux isotope reactor CG1-D imaging beamline, National Institute of Standard and Technology (NIST) BT-2, and NIST NG6 imaging beamlines.

47 OTHER INSTRUMENTATION↗

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.

47 OTHER INSTRUMENTATION↗

PIONEER, a high-resolution single-crystal polarized neutron diffractometer

PIONEER is a high Q-resolution, single-crystal, polarized neutron diffractometer at the Second Target Station (STS), Oak Ridge National Laboratory. It will provide the unprecedented capability of measuring tiny crystals (0.001 mm 3 , i.e., x-ray diffraction size), ultra-thin films (10 nm thickness), and weak structural and magnetic transitions. PIONEER benefits from the increased peak brightness of STS cold-neutron sources and uses advanced Montel mirrors that are able to deliver a focused beam with a high brilliance transfer, a homogeneous profile, and a low background. Monte Carlo simulations suggest that the optimized instrument has a high theoretical peak brilliance of 2.9 × 10 12 n cm -2 sr -1 Å -1 s -1 at 2.5 Å at the sample position, within a 5 × 5 mm 2 region and a ±0.3° divergence range. The moderator-to-sample distance is 60 m, providing a nominal wavelength band of 4.3 Å with a wavelength resolution better than 0.2% in the wavelength range of 1.0–6.0 Å. PIONEER is capable of characterizing large-scale periodic structures up to 200 Å. With a sample-to-detector distance of 0.8 m, PIONEER accommodates various sample environments, including low/high temperature, high pressure, and high magnetic/electric field. Additionally, a large cylindrical detector array (4.0 sr) with a radial collimator is planned to suppress the background scattering from sample environments. Bottom detector banks provide an additional 0.4 sr coverage or can be removed if needed to accommodate special sample environments. We present virtual experimental results to demonstrate the scientific performance of PIONEER in measuring tiny samples.

47 OTHER INSTRUMENTATION↗